• Title/Summary/Keyword: Plastic Stability

Search Result 601, Processing Time 0.026 seconds

Large-scale cyclic test on frame-supported-transfer-slab reinforced concrete structure retrofitted by sector lead rubber dampers

  • Xin Xu;Yun Zhou;Zhang Yan Chen;Da yang Wang;Ke Jiang;Song Wang
    • Earthquakes and Structures
    • /
    • v.26 no.5
    • /
    • pp.383-400
    • /
    • 2024
  • For a conventionally repaired frame-supported-transfer-slab (FSTS) reinforced concrete (RC) structure, both the transfer slab and the beam-to-column and transfer slab-to-column joints remain vulnerable to secondary earthquakes. Aimed at improving the seismic performance of a damaged FSTS RC structure, an innovative retrofitting scheme is proposed, which adopts the sector lead rubber dampers (SLRDs) at joints after the damaged FSTS RC structure is repaired by conventional approaches. In this paper, a series of quasi-static cyclic tests was conducted on a large-scale retrofitted FSTS RC structure. The seismic performance was evaluated and the key test results, including deformation characteristics, damage pattern, hysteretic behaviour, bearing capacity and strains on key components, were reported in detail. The test results indicated that the SLRDs started to dissipate energy under the service level earthquake, and thus prevented damages on the beam-to-column and transfer slab-to-column joints during the secondary earthquakes and shifted the plastic hinges away from the beam ends. The retrofitting scheme of using SLRDs also achieved the seismic design concept of 'strong joint, weak component'. The FSTS RC structure retrofitted by the SLRDs could recover more than 85% bearing capacity of its undamaged counterpart. The hysteresis curves were featured by the inverse "S" shape, indicating good bearing capacity and hysteresis performance. The deformation capacity of the damaged FSTS RC structure retrofitted by the SLRDs met the corresponding codified requirements for the case of the maximum considered earthquake, as set out in the Chinese seismic design code. The stability of the FSTS RC structure retrofitted by the SLRDs, which was revealed by the developed stains of the RC frame and transfer slab, was improved compared with the undamaged FSTS RC structure.

Mechanical and Electrical Properties of Self-sensing Grout Material with a High-Volume Ultrafine Fly Ash Replacement (초고분말 플라이 애시를 다량 치환한 자기감지형 그라우트재의 역학적 및 전기적 특성)

  • Lee, Gun-Cheol;Kim, Young-Min;Im, Geon-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.2
    • /
    • pp.215-226
    • /
    • 2024
  • This study presents an experimental investigation into the performance of self-sensing grout formulated with a high volume of ultra-fine fly ash(UHFA). To explore the potential benefits of alternative cementitious materials, the research examined the effect of substituting UHFA with equal parts of blast furnace slag(BFS) fine powder. Both UHFA and BFS are byproducts generated in significant quantities by industrial processes. The evaluation focused on the fresh properties of the grout, including its flow characteristics, as well as the hardened properties such as compressive strength, dimensional stability(length change rate), and electrical properties. The experimental results demonstrated that incorporating UHFA resulted in a substantial reduction in the plastic viscosity of the grout, translating to improved flowability. Additionally, the compressive strength of the UHFA-modified grout surpassed that of the reference grout(without UHFA substitution) at all curing ages investigated. Interestingly, the electrical characteristics, as indicated by the relationships between FCR-stress and FCR-strain, exhibited similar trends for both grout mixtures.

Influence of Tightening Torque on Implant-Abutment Screw Joint Stability (조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향)

  • Shin, Hyon-Mo;Jeong, Chang-Mo;Jeon, Yonung-Chan;Yun, Mi-Jeong;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.396-408
    • /
    • 2008
  • Statement of problem: Within the elastic limit of the screw, the greater the preload, the tighter and more secure the screw joint. However, additional tensile forces can incur plastic deformation of the abutment screw when functional loads are superimposed on preload stresses, and they can elicit the loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum preload that will maximize fatigue life and simultaneously offer a reasonable degree of protection against loosening. Another critical factor in addition to the applied torque which can affect the amount of preload is the joint connection type between implant and abutment. Purpose: The purpose of this study was to evaluate the influence of tightening torque on the implant-abutment screw joint stability. Material and methods: Respectively, three different amount of tightening torque (20, 30, and 40 Ncm) were applied to implant systems with three different joint connections, one external butt joint and two internal cones. The initial removal torque value and the postload (cyclic loading up to 100,000 cycles) removal torque value of the abutment screw were measured with digital torque gauge. Then rate of the initial and the postload removal torque loss were calculated for the comparison of the effect of tightening torques and joint connection types between implant and abutment on the joint stability. Results and conclusion: 1. Increase in tightening torque value resulted in significant increase in initial and postload removal torque value in all implant systems (P < .05). 2. Initial removal torque loss rates in SS II system were not significantly different when three different tightening torque values were applied (P > .05), however GS II and US II systems exhibited significantly lower loss rates with 40 Ncm torque value than with 20 Ncm (P < .05). 3. In all implant systems, postload removal torque loss rates were lowest when the torque value of 30 Ncm was applied (P < .05). 4. Postload removal torque loss rates tended to increase in order of SS II, GS II and US II system. 5. There was no correlation between initial removal torque value and postload removal torque loss rate (P > .05).

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

A Rheological Study on Creep Behavior of Clays (점토(粘土)의 Creep 거동(擧動)에 관한 유변학적(流變學的) 연구(研究))

  • Lee, Chong Kue;Chung, In Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.53-68
    • /
    • 1981
  • Most clays under sustained load exhibit time-dependent deformation because of creep movement of soil particles and many investigators have attempted to relate their findings to the creep behavior of natural ground and to the long-term stability of slopes. Since the creep behavior of clays may assume a variety of forms depending on such factors as soil plasticity, activity and water content, it is difficult and complicated to analyse the creep behavior of clays. Rheological models composed of linear springs in combination with linear or nonlinear dashpots and sliders, are generally used for the mathematical description of the time-dependent behavior of soils. Most rheological models, however, have been proposed to simulate the behavior of secondary compression for saturated clays and few definitive data exist that can evaluate the behavior of non-saturated clays under the action of sustained stress. The clays change gradually from a solid state through plastic state to a liquid state with increasing water content, therefore, the rheological models also change. On the other hand, creep is time-dependent, and also the effect of thixotropy is time-function. Consequently, there may be certain correlations between creep behavior and the effects of thixotropy in compacted clays. In addition, the states of clay depend on water content and hence the height of the specimen under drained conditions. Futhermore, based on present and past studies, because immediate elastic deformation occurs instantly after the pressure increment without time-delayed behavior, the factor representing immediate elastic deformations in the rheological model is necessary. The investigation described in this paper, based on rheological model, is designed to identify the immediate elastic deformations and the effects of thixotropy and height of clay specimens with varing water content and stress level on creep deformations. For these purposes, the uniaxial drain-type creep tests were performed. Test results and data for three compacted clays have shown that a linear top spring is needed to account for immediate elastic deformations in the rheological model, and at lower water content below the visco-plastic limit, the effects of thixotropy and height of clay specimens can be represented by the proposed rheological model not considering the effects. Therefore, the rheological model does not necessitate the other factors representing these effects. On the other hand, at water content higher than the visco-plastic limit, although the state behavior of clays is visco-plastic or viscous flow at the beginning of the test, the state behavior, in the case of the lower height sample, does not represent the same behavior during the process of the test, because of rapid drainage. In these cases, the rheological model does not coincide with the model in the case of the higher specimens.

  • PDF

Quality and Storage Characteristics of Low Salted Onion and Five Cereals-Doenjang (저염 양파 오곡된장의 품질 및 저장 특성)

  • Shin, A-Ga;Lee, Ye-Kyung;Jung, Yoo-Kyung;Kim, Soon-Dong
    • Food Science and Preservation
    • /
    • v.15 no.2
    • /
    • pp.174-184
    • /
    • 2008
  • The quality and storage characteristics of low salted onion and five cereals-doenjang (DFO) were investigated. At the DFO, soybean koji ($57{\sim}62%$), onion (3%) and salt (8%) were mixed with equal amount of rice, barley, glutinous millet and glutinous indian millet ($10{\sim}30%$), and water ($7{\sim}12%$). The storage of DFO was done by vacuum packing in polypropylene tube, and sterilized at $121^{\circ}C$. The fermentation and storage was conducted for 60 days at $25^{\circ}C$ at each condition. Control doenjang (GD) was the salinity of 16% soybean doenjang that was not sterilized and packed in plastic containers for storage. During the fermentation, pH of DFO was lower than GD. The pH maintained stability during the storage, and revealed to be lowered, as the proportion of mixed cereals was higher. During the fermentation of DFO, the brix degree revealed to be higher than GD and maintained s1ability during the storage. During the fermentation and storage, the amino nitrogen content of DFO was ranged $400{\sim}470mg%$ by showing higher content than GD and maintained stable content during the storage. During the fermentation, the activities of protease and ${\beta}$-amylase were maintained to be high at DFO, but the activities during the storage were high at GD. The color $L^*$ value of DFO during fermentation and storage maintained higher values than GD, but $a^*$ value revealed lower pattern. Total free amino acids of DFO was ranged $1,918{\sim}2,290mg%$ which was higher than GD that recorded 1,291 mg%. When the sensory evaluation was conducted for DFO that was fermented and stored for 60 days, the DFO mixed with $20{\sim}30%$ of cereals resulted to have more savory taste, flavor, and sweeter than GD, and overall acceptability for color and overall taste was high.

Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse (플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략)

  • Lee, JungKyu;Kang, DongHyun;Oh, SangHoon;Lee, DongHoon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • There is systematic spatial variations in environmental properties due to sensitive reaction to external conditions at plastic greenhouse occupied 99.2% of domestic agricultural facilities. In order to construct 3 dimensional distribution of temperature, relative humidity, CO2 and illuminance, measurement matrix as 3 by 3 by 5 in direction of width, height and length, respectively, dividing indoor space of greenhouse was designed and tested at experimental site. Linear regression analysis was conducted to evaluate optimal estimation method in terms with horizontal and vertical variations. Even though sole measurement point for temperature and relative humidity could be feasible to assess indoor condition, multiple measurement matrix is inevitably required to improve spatial precision at certain time domain such as period of sunrise and sunset. In case with CO2, multiple measurement matrix could not successfully improve the spatial predictability during a whole experimental period. In case with illuminance, prediction performance was getting smaller after a time period of sunrise due to systematic interference such as indoor structure. Thus, multiple sensing methodology was proposed in direction of length at higher height than growing bed, which could compensate estimation error in spatial domain. Appropriate measurement matrix could be constructed considering the transition of stability in indoor environmental properties due to external variations. As a result, optimal measurement matrix should be carefully designed considering flexibility of construction relevant with the type of property, indoor structure, the purpose of crop and the period of growth. For an instance, partial cooling and heating system to save a consumption of energy supplement could be successfully accomplished by the deployment of multiple measurement matrix.

THE EFFECT OF RESORBABLE MEMBRANE ON BONE REGENERATION IN CALVARIAL DEFECTS OF RATS (백서의 두개골 결손부에서 탈단백우골 이식 시 흡수성악의 효과)

  • Park, Young-Jun;Choi, Guen-Ho;Jang, Jung-Rok;Jung, Seung-Gon;Kim, Young-Joon;Yu, Min-Gi;Kook, Min-Suk;Oh, Hee-Kyun;Ryu, Sun-Youl;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.5
    • /
    • pp.365-374
    • /
    • 2009
  • Purpose : This research evaluates the effect of the use of absorbable membrane barrier with deproteinized bovine bone (Bio-$Oss^{(R)}$, Switzerland) on bone healing in surgically created critical-sized defects in rat calvaria. Materials and Methods : Two standardized transosseous circular calvarial defects (5 mm in diameter) are made in each calvarium of 30 rats. These rats are divided into negative control group(n=15), positive control group(n=15) and two experimental groups(n=15). In the negative control group, defects are only filled with blood clots. In the positive control group, defects are filled with autogenous bone obtained from calvarium; in the experimental group 1, defects are filled with deproteinized bovine bone; and in the experimental group 2, defects are filled with deproteinized bovine bone with absorbable membrane. At the postoperative 1 week, 3 weeks. and 6 weeks, clinical. histologic and histomorphometric evaluations of the defects are performed. Results : 1. The grafted bone without membrane in the calvarial bone defect was scattered but, the grafted bone with membrane was stable. 2. $BioMesh^{(R)}$ membrane was absorbed beginning at 3 weeks, and was absorbed considerably at 6 weeks while maintaining the structural form of the membrane. 3. The use of membrane blocked soft tissue invasion. 4. In histomorphometric analysis. it showed the greatest amount of new bone formation in the positive control group. The amount of new bone formation was greater in the experimental group 2 than experimental group 1. At 6 weeks. the amount of new bone formation was greater in the positive control group than experimental group l(p<0.005). Conclusion : These results suggest that membrane increase the stability of grafted bone and protects from soft tissue invasion, and the use of the membrane may promote new bone formation in deproteinized bovine bone graft area.

Simulation of Solitary Wave-Induced Dynamic Responses of Soil Foundation Around Vertical Revetment (고립파 작용하 직립호안 주변에서 지반의 동적응답에 관한 수치시뮬레이션)

  • Lee, Kwang-Ho;Yuk, Seung-Min;Kim, Do-Sam;Kim, Tae-Hyeong;Lee, Yoon-Doo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.6
    • /
    • pp.367-380
    • /
    • 2014
  • Tsunami take away life, wash houses away and bring devastation to social infrastructures such as breakwaters, bridges and ports. The targeted coastal structure object in this study can be damaged mainly by the tsunami force together with foundation ground failure due to scouring and liquefaction. The increase of excess pore water pressure composed of oscillatory and residual components may reduce effective stress and, consequently, the seabed may liquefy. If liquefaction occurs in the seabed, the structure may sink, overturn, and eventually increase the failure potential. In this study, the solitary wave was generated using 2D-NIT(Two-Dimensional Numerical Irregular wave Tank) model, and the dynamic wave pressure acting on the seabed and the estimated surface boundary of the vertical revetment. Simulation results were used as an input data in a finite element computer program(FLIP) for elasto-plastic seabed response. The time and spatial variations in excess pore water pressure, effective stress, seabed deformation, structure displacement and liquefaction potential in the seabed were estimated. From the results of the analysis, the stability of the vertical revetment was evaluated.