• Title/Summary/Keyword: Plastic Stability

Search Result 604, Processing Time 0.026 seconds

The effect of biphasic calcium phosphate and demineralized bone matrix on tooth eruption in mongrel dogs

  • Lee, Si Woo;Kim, Ji-Young;Hong, Ki Yong;Choi, Tae Hyun;Kim, Byung Jun;Kim, Sukwha
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.5
    • /
    • pp.239-246
    • /
    • 2021
  • Background: Bone grafts can provide an optimal environment for permanent tooth to erupt and enhance the stability of the alveolar maxilla. Although autologous bone is an optimal source for osteogenesis, its inevitable donor site morbidity has led to active research on bone substitutes. This study was designed to evaluate the safety and feasibility of using biphasic calcium phosphate (BCP; Osteon) as a bone substitute in dogs. Methods: Bilateral third and fourth premolars of four 15-week-old mongrel dogs were used. All teeth were extracted except the third premolar of the right mandible, which was used as a control. After extraction of the premolars, each dog was administered BCP (Osteon), demineralized bone matrix (DBM; DBX), and no graft in the hollow sockets of the right fourth premolar, left fourth premolar, and left third premolar, respectively. Radiographs were taken at 2-week intervals to check for tooth eruption. After 8 weeks, each dog was sacrificed, and tooth and bone biopsies were performed to check for the presence of tooth and bone substitute particle remnants. Results: Four weeks after the operation, permanent tooth eruptions had started at all the extraction sites in each dog. Eight weeks after the operation, all teeth had normally erupted, and histological examination revealed BCP particles at the right fourth premolar. Conclusion: In all four dogs, no delay in the eruption of the teeth or shape disfigurement of permanent teeth was observed on gross inspection and radiologic evaluation. On histological examination, most of the BCP and DBM were replaced by new bone. Bone substitutes can be used as graft materials in patients with alveolar clefts.

COMPARATIVE STUDY OF STABILITY AND RELAPSE ACCORDING TO FIXATION METHOD AFTER BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMIES IN MANDIBULAR PROGNATHIC PATIENTS (하악전돌증 환자의 하악지시상분할골절단술 후 고정방법에 따른 안정성과 회귀율에 대한 분석)

  • Choi, Hee-Won;Kim, Kyoung-Won;Lee, Eun-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.4
    • /
    • pp.334-345
    • /
    • 2005
  • The purpose of this study was to compare the postoperative stability and relapse according to 2 different fixation methods after bilateral sagittal split ramus osteotomies in mandibular prognathic patients. Tweenty one patients with Class III dental and skeletal malocclusion who were treated with bilateral sagittal split ramus osteotomy were selected for this retrospective study. We classfied the patients into two groups according to the fixation methods of bony segments after osteotomies. Group W (n = 10) had the bone segments fixed with nonrigid wire and Group S (n = 11) had bicortical screws inserted in the gonial area through a transcutaneous approach. Cephalometric radiographs were taken preoperatively, immediate postoperatively and more than six months postoperatively in each patient. After tracing the cephalometric radiographs, various parameters were measured. Before surgery, both groups were balanced with respect to linear and angular measurements of craniofacial morphology. Mean posterior sagittal setback amounts of the mandibular symphysis was 8.6 mm in the wire group and 6.79 mm in the rigid group, Six months postoperatively, the wire group had 33.1% relapse of the mandibular symphysis and 22.8% in the rigid group relapse. Both groups experienced changes in the orientation and configuration of the mandible. It is thought that Rigid screw fixation is a more stable method than nonrigid wire fixation for maintaining mandibular setback after sagittal split ramus osteotomy.

THE CORRECTION OF CLASS III MANDIBULAR ASYMMETRY USING BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY AND LATERAL ANGLE REDUCTION (외측 하악각 골절제술을 동반한 시상분할골절단술을 통한 골격성 3급 하악골 비대칭 환자의 치료)

  • Kang, Hee-Jea;Song, In-Woo;Kang, Yung-Ki;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.2
    • /
    • pp.132-140
    • /
    • 2010
  • Purpose: The aim of this study is to identify the usefulness of unilateral mandibular angle ostectomy, so-called "Lateral Angle Reduction", in asymmetric prognathism patients by the assessment of postoperative stability and esthetic results Patients and methods: For the retrospective study, 10 skeletal class III mandibular asymmetry patients who were performed SSRO and unilateral mandibular angle ostectomy, Lateral Angle Reduction, was selected. Lateral and posterioanterior cephalogram was taken before surgery (T0), 1day after surgery (T1) and 6month after surgery (T2). To know the esthetic results the facial width and lateral facial contour were examined on posterioanterior cephalogram and to know the postoperative stability B point and Incisor inferius was examined on lateral cephalogram. Statistical analysis was performed. Results: From T0 to T1, Intergonial width was significantly decreased, dominantly at shortened side but no significant changes at lengthened side. Those were well-maintained during 6 months. Lateral facial angle and Ramus angle was significantly decreased on only shortened side from T0 to T1. As a result, after surgery, there were no significant differences in all measurements between shortened side and lengthened side. Ramus deviation angle in shortened side and ramus angle in lengthened side which reflect the angulation of ramus on frontal plane didn't show significant changes after surgery and during postsurgical periods. Lower dental midline showed no statistical changes during postsurgical period. The relapse rate on B-point was 11.92%. Conclusion: Unilateral "Lateral angle reduction" in the asymmetric mandible is valuable to obtain the narrow lower face and symmetric facial contour with a good stability.

STABILITY OF SIMULTANEOUS MAXILLARY AND MANDIBULAR SURGERY;[Ⅰ]Wire osteosynthesis (상하악 동시 악교정술시 안정성에 관한 연구;[Ⅰ] 강선 고정에 의한 방법)

  • Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.2
    • /
    • pp.9-20
    • /
    • 1990
  • A series of 19 cases with maxillary hyperplasia and mandibular retrognathia were operated on by simultaneous superior repositioning of the maxilla after Le Fort I osteotomy and anterior repositioning of the mandible after bilateral sagittal split ramus osteotomies with or without osteotomy of the inferior border of the mandible. These were evaluated by retrospective cephalometric and computer analysis for the longitudinal skeletal and dental changes for an average of 17.1 months after surgery. For stabilization of the osteotomized segments, the authors used wire osteosynthesis by means of bilateral infraorbital and zygomatic buttress suspension wire at the maxilla, and direct interosseous wire at the split segments of the mandibular rami. Results show generally good stability after simultaneous maxillary and mandibular surgery with wire osteosynthesis, and a minimal to moderate tendency toward skeletal and dental relapse. This article is a preliminary study to defy the efficiency of the wire osteosynthesis (wo)compared with rigid internal fixation (RIF) for simultaneous maxillary and mandibular surgery. 1. The vertical relapse rate of the A point after superior repositioning of the maxilla is 2.2%. 2. The horizontal relapse rate of the B point after advancement of the mandible is 18.3%. 3. The condyle is distracted inferiorly and slightly posteriorly at the immediate postoperative period. 4. At the long term follow up examination, the condyle presents tendency of return to the preoperative position. 5. Condylar segment angle is decreased at the immediate postoperative period, and at the long term follow up evaluation, the angle is increased. 6. Gonial angle is increased at the immediate postoperative period, and then is decreased at the long term follow up evaluation. 7. The dentition is satisfactory with acceptable movement at the long term follow up evaluation. 8. At the mandibular free body analysis, genioplasty shows good stability. 9. Wire osteosynthesis provides excellent stabilization for the simultaneous maxillary and mandibular surgery.

  • PDF

Post-operative Stability of Counter Clockwise Rotation of the Mandibular Plane in Skeletal CIII with Anterior Openbite Patients (전치부 개교합을 가진 골격성 3급 부정교합 환자에서 하악의 반시계 방향 회전 시 술 후 안정성)

  • Ryu, Jeong-Min;Ryu, Kyung-Sun;Lee, Baek-Soo;Kwon, Yong-Dae;Choi, Byung-Joon;Kim, Yeo-Gab;Ohe, Joo-Young;Park, Seong-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.4
    • /
    • pp.252-259
    • /
    • 2012
  • Purpose: This study evaluated the postoperative stability of counter clockwise rotation of the mandibular plane in anterior openbite patients, who have had one jaw surgery performed. Methods: This study includes patients with skeletal class III malocclusion accompanied by anterior openbite among the patients who have had BSSRO performed, resulting in counter clockwise rotation of the mandibule. We excluded the patients with genioplasty and segmental surgery, and included 23 patients who underwent BSSRO. Results: We found no statistical significance between the amount of counter clockwise rotation in the mandible in the Pearson correlation test. Also, there was no significant difference between Group 1 (< $3^{\circ}$) and Group 2 (> $3^{\circ}$). Conclusion: This study evaluated the amount of horizontal relapse, and the degree of relapse. Stable results were obtained. Although there was no statistical significance between the degree of openbite and the amount of horizontal relapse, the group with a greater amount of openbite had a greater amount of relapse.

Study on performance verification of dual-purpose rockbolt for reinforcement and drainage (지반 보강과 배수를 위한 이중기능 록볼트 성능 검증에 관한 연구)

  • Jung, Young-Hoon;Kim, Doo-Rae;Kim, Kyeong-Cheol;Shin, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.5
    • /
    • pp.869-886
    • /
    • 2018
  • Rockbolt is one of the most common supports used to reinforce discontinuous rock during underground excavation. Extra drain pipes are installed to improve excavation workability and the anchorage of rockbolts in water bearing ground. The drain pipe is effective in improving the workability by providing drainage path, but it is difficult to expect the reinforcement effect, increasing disturbance of the discontinuous rock mass and the construction cost. To solve this problem, dual purpose rockbolt (DPR) has been developed for the reinforcement of rock and the drainage of ground water. DPR was able to improve the mechanical and hydraulic stability of the rocks quickly and economically. Two kinds of DPRs using FRP (Fiber Reinforced Plastic) and steel were investigated for the mechanical and hydraulic performance. Also, the workability and stability of DPR were analyzed.

Stability and Adhesion of Diamond-like Carbon Film under Micro-tensile Test Condition (미소 인장시험을 통한 다이아몬드상 카본 박막의 안정성 및 접합력 평가)

  • Choi Heon Woong;Lee Kwang-Ryeol;Wang Rizhi;Oh Kyu Hwan
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.4
    • /
    • pp.175-181
    • /
    • 2004
  • We investigated the stability of the DLC film coated on 304 stainless steel substrate by Radio frequency assisted chemical vapor deposition method. Fracture and spallation behaviour of the coating was observed during micro-tensile test of the fil $m_strate composite. As the tensile deformation progressed, the cracks of the film were observed in the perpendicular direction to the tensile axis. Further deformation resulted in the plastic deformation with $45^{\circ}$ slip bands on the substrate surface. Spallation of the film occurred with the plastic deformation, which was initiated at the cracks of the film and was aligned along the slip directions. We found that both the cracking and the spallation behaviors are strongly dependent on the pre-treatment condition, such as Ar plasma pre-treatment. The spallation of the film was considerably suppressed in an optimized condition of the substrate cleaning by Ar glow discharge. We observed the improved stability with increasing duration of Ar plasma pre-treatment.nt.

Bony Stability and Soft Tissue Changes after Orthognathic Surgery on Patients with Cleft (구순구개열 환자의 악교정 수술 후의 골조직 안정도와 연조직 변화율)

  • Shin, Heakyeong;Hsieh, Yuh-Jia;Liao, Yu-Fang;Lo, Lun-Jou;Jo, Myoung-Soo
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.4-10
    • /
    • 2012
  • Purpose: The objective of this retrospective study was to assess the skeletal stability after orthognathic surgery for patients with cleft lip and palate. The soft tissue changes in relation to the skeletal movement were also evaluated. Methods: Thirty one patients with cleft received orthognathic surgery by one surgeon at the Craniofacial Center, Chang Gung Memorial Hospital, Taoyuan, Taiwan. Osseous and soft tissue landmarks were localized on lateral cephalograms taken at preoperative (T0), postoperative (T1), and after completion of orthodontic treatment (T2) stages. Surgical movement (T0.T1) and relapse (T1.T2) were measured and compared. Results: Mean anteroposterior horizontal advancement of maxilla at point A was 5.5 mm, and the mean horizontal relapse was 0.5 mm (9.1%). The degree of horizontal relapse was found to be correlated to the extent of maxillary advancement. Mean vertical lengthening of maxilla at point A was 3.2 mm, and the mean vertical relapse was 0.6 mm (18.8%). All cases had maxillary clockwise rotation with a mean of 4.4 degrees. The ratio for horizontal advancement of nasal tip/anterior nasal spine was 0.54/1, and the ratio of A' point/A point was 0.68/1 and 0.69/1 for the upper vermilion/upper incisor tip. Conclusion: Satisfactory skeletal stability with an acceptable relapse rate was obtained from this study. High soft tissue to skeletal tissue ratios were obtained. Two-jaw surgery, clockwise rotation, rigid fixation, and alar cinch suture appeared to be the contributing factors for favorable results.

Clinical reliability of zirconium abutment in implant restorations in the English and Korean literature

  • Yu, Su-Been;Song, Bong-Gyu;Cheon, Kyeong-Jun;Kim, Ju-Won;Kim, Young-Hee;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.26.1-26.10
    • /
    • 2018
  • Background: This study aimed to evaluate the mechanical, biological, and esthetic stability of a zirconium abutment according to evidence-based dentistry. Main text: An electronic search was performed. Domestic studies were found using the keywords "zirconia abutments" and "zirconium abutment" in KMbase, KoreaMed, and the National Assembly Library, and international studies were found using the same keywords in PubMed. All identified studies were divided by evidence level from the viewpoint of the research type utilizing the evidence-based review manual. A total of 102 domestic studies (with Korean language) were found, and 9 of these studies were selected. In these nine studies, 3 had evidence level 3 and 6 had evidence level 4. A total of 97 international studies (with English language) were found, and 19 were selected. Among these 19 studies, 5 had evidence level 2 and 7 had evidence level 3, whereas the remainder had evidence level 4. According to the studies, zirconium abutments are mechanically, biologically, and esthetically stable, but the evidence level of these studies is low, and the follow-up duration is no longer than 5 years. Conclusions: All examined studies verified the mechanical stability of zirconium abutments for a period no longer than 5 years. Therefore, a long-term clinical observation is needed. Zirconium abutments are thought to be biologically stable, but they are not superior to titanium abutments. As the esthetic stability of such abutments had a low evidence level in the studies that examined here, a much higher evidence level is needed.

Orthognathic surgery for patients with fibrous dysplasia involved with dentition

  • Udayakumar, Santhiya Iswarya Vinothini;Paeng, Jun-Young;Choi, So-Young;Shin, Hong-In;Lee, Sung-Tak;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.37.1-37.7
    • /
    • 2018
  • Background: Fibrous dysplasia (FD) is characterized by the replacement of normal bone by abnormal fibro-osseous connective tissue and typically treated with surgical contouring of the dysplastic bone. When dysplastic lesions involve occlusion, not only is surgical debulking needed, orthognathic surgery for correction of dentofacial deformity is mandatory. However, the long-term stability of osteotomized, dysplastic bone segments is a major concern because of insufficient screw-to-bone engagement during surgery and the risk of FD lesion re-growth. Case presentation: This case report reviewed two patients with non-syndromic FD that presented with maxillary occlusal canting and facial asymmetry. Le Fort I osteotomy with recontouring of the dysplastic zygomaticomaxillary region had been performed. The stability of osseous segments were favorable. However, dysplastic, newly formed bone covered the previous plate fixation site and mild bony expansion was observed, which did not influence the facial profile. Including the current cases, 15 cases of orthognathic surgery for FD with dentition have been reported in the literature. Conclusion: The results showed that osteotomy did not appear to significantly reduce the long-term stability of the initial fixation insufficiency of the screw to the dysplastic bone. However, based on our results and those of the others, long-term follow-up and monitoring are needed, even in cases where the osteotomized segment shows stable results.