• Title/Summary/Keyword: Plaster Technique

Search Result 42, Processing Time 0.026 seconds

Fixed prosthodontic rehabilitation of maxillary posterior teeth using functionally generated path technique and intraoral digital scan: Case report (Functionally generated path technique 및 구내 디지털 스캔을 이용한 상악 구치부의 고정성 보철 수복 증례)

  • Kim, Sung-Ho;Lee, Jonghyuk;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.228-238
    • /
    • 2020
  • In order to deliver fixed partial denture to a patient successfully, dentist must take into many considerations beforehand. Patient's occlusal pattern should be fully understood before delivering any type of prosthesis, whether it's canine guidance or group function occlusion. In order to do so, movement of mandible should be recorded precisely. Introduced by Meyers in 1933, functionally generated path technique (FGP) has been successfully used to record mandibular movement with various materials, such as wax, and utilize it in fabricating precise prosthesis. In the following cases, patients showed secondary caries or endodontic-periodontic lesion on maxillary molars. Root canal treatment and subgingival curettage were done for each patient. Since the long term prognosis of each tooth was questionable, lateral force should be minimized. In order to do so, FGP technique was used to record mandibular movements precisely. Instead of using conventional plaster impression, intra-oral scanning of wax tracing was done to fabricate prosthesis efficiently. After delivery of fixed partial denture, favorable outcome was obtained.

Accident research II for the college students happened during Dental Laboratory Technology-major classes (치기공과 실습 중 안전사고 실태조사 II)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.131-153
    • /
    • 2005
  • The purpose of this study was to identify the accidents happened in the college dental laboratory technique classes and to realize the level of safety education for the dental laboratory technique major students. The research data were collected from a self-administered survey distributed to the conveniently selected college students whose majors were dental laboratory technology in Suwon, Daejeon, Daegu, Kimcheon, and Icsan. The study participants were 422 freshmen, sophomore and junior students in the selected cities. All collected survey responses were encoded and analyzed in SPSS 12.0. The findings were as follows. 1. The students who had any accidents in their laboratory classes were 36% and the other 64% answered 'no.' 2. Most injuries which the participants had were not significant. 3. The medical treatment periods of most injury cases were less than one week; however, approximately 20% of the self-reported injury cases reported that their treatment periods were longer than one week. 4. The body parts frequently injured from accidents were hands with 84.7% and arms, eyes, face, head, and legs in order. 5. Concerning the materials involved in the laboratory classes, most accidents happened when working with wax in 59.9%, with plaster in 52.3%, with wire in 39.8%, with alcohol in 34.6%, and casting iron in 22.2% in order. 6. The accident-prone laboratory methods were polishing with 53.5%, pickling or sanding with 17.4%, and casting or burning with 5.8% in order. 7. Most students wore their laboratory gowns well; however, few students wore mask before dust-involved jobs. Furthermore, only 57.1% students answered their laboratory fans worked during the polishing job. 8. Approximately 54% participant students answered that they took laboratory safety education when necessary only from the class instructors. 9. The 76.1% students responded that they needed laboratory safety education at least 1-2 times every semester. 10. The survey participants answered that the primary factors for injury prevention in their laboratory were taking safety education, wearing safety equipments, and providing safety-focused facilities. Concludingly, comprehensive evaluation and monitoring for potential risk factors from both the human side and the environment side should be continually provided to minimize the college laboratory accidents.

  • PDF

A Study on the Shape-Decision Technique of Membrane Structures According to the Design Process and Shape Analysis (건축 설계프로세스와 형상해석을 통한 막 구조물의 형상결정 방안에 관한 연구)

  • Park, Sun-Woo;Kim, Seung-Deog;Shon, Su-Deok;Jeong, Eul-Seok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.2 s.24
    • /
    • pp.115-124
    • /
    • 2007
  • The initial shape is arrived at by a self-formation process, which accomplishes a form in the natural world, or is determined analytically by considering the equilibrium of initial stress only. Therefore, the self-formation process, which accomplishes a form in the natural world is grasped and the types of modeling techniques available to find the shapes of soft structures are well investigated and classified. To establish a form-finding modeling techniques, the models of string, soap film, fabric, rubber, plaster, and etc. are used. These modeling techniques can be used as a method of understanding the characteristics of structures when the material of model shows similar characteristics. Generally, the model test confirms the structure based on numerical analysis, at the same time it is important preceding process to develop such a program. With the above process, the relationship between model test and numerical analysis becomes a feedback process. Therefore, in this study, two examples which have been accomplished from such a technique are investigated and considered according to modeling process.

  • PDF

Treatment of Carpal Scaphoid Fracture (주상골 골절의 수술적 치험례)

  • Beck, Won-Jin;Seo, Jae-Sung;Ahn, Jong-Chul;Ihn, Joo-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.361-366
    • /
    • 1986
  • Fracture of the carpal scaphoid bone is the most common fracture of the carpus. Unfortunately. nonunion are common since the symptoms do not alert patients to seek early medical treatment and the diagnosis is easily missed. Fracture of the scaphoid is a common condition whose management remains controversial. The conservative treatment has many complications, these include inability to work while in plaster, stiffness of the wrist afterwards, muscle wasting, weakness and malunion. So various operative treatments of scaphoid fracture have been developed. Open reduction by use of screws suggested by Maclaughlin first in 1954. In 1984 a new and simple operative technique has been developed to provide rigid internal fixation for all types of fractures of the scaphoid by T.J. Herbert. This involves the use of a double-treaded bone screw which provides good fixation that, after operation, a plaster cast is rarely required and most patients are able to return to work within a few weeks. Authors have experienced 10 cases of scaphoid fracture and accomplished good result in all cases by internal fixation using Herbert screw. The results are as follows : Of these 10 fractures, 2 were fresh fractures and 8 were non unions of scaphoid fracture. In nonunion cases, the time interval between fracture and operation was from 5 months to 5 years. The postoperative immobilization period was average of 4 weeks. Short period of immobilization achieved early functional recovery of the wrist. The bony unions in roentgenogram were seen from 3 months to 9 months after operation. In 2 cases the fracture gap was seen after 9 months. But in these cases the symptoms such as pain and range of motion of wrist were improved.

  • PDF

Study on the Manufacturing Technology of Mural Tomb in Goa-dong of Daegaya Period (대가야 고아동 고분벽화 제작기술에 관한 연구)

  • Lee, Hwa Soo;Lee, Han Hyeong;Lee, Kyeong Min;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.457-466
    • /
    • 2014
  • Rigorous analysis was performed to identify the structure and materials of the murals to study techniques used on mural tombs of ancient Daegaya era(6th century). The murals were painted by applying mortar on the walls and the ceiling after building a stone chamber and creating ground layers on mortar layers. Mud was applied on most of the mortar layers on four sides of the walls except the ceiling. Sand was not used in mortar but was made of materials with pure calcium substances. In addition, shells in irregular sizes with incomplete calcination were mixed; and the mortar's white powder was inferred as lime obtained by calcination of oyster shells. Kaolinite($Al_2Si_2O_5(OH)_4$) was used in the ground layer, Cinnabar(HgS) was used for red pigment, Malachite($Cu_2CO_3(OH)_2$) for green and Lead white($PbCO_3{\cdot}Pb(OH)_2$) for white. Mud plaster was applied on the mortar and was composed thinly and densely using clayey of particle size smaller than that of medium sand. It was assumed that the finishing was for repair after long time had passed since the mortar layer came off. Using lime made with oyster shells as mortar is unprecedented in ancient Korean mural tombs and its durability was very poor, suggesting that Gaya's mortar production technique was relatively behind compared to that of Koguryo's in the same era.

MARGINAL FIT RELATED TO MARGIN TYPES OF GLASS INFILTRATED ALUMINA CORE FABRICATED FROM AQUEOUS-BASED ALUMINA TAPE

  • Oh, Nam-Sik;Yu, Byeung-Su;Kim, Il-Kyu;Choi, Jin-Ho;Kim, Dae-Joon;Park, Il-Seok;Lee, Myung-Hyun;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.262-268
    • /
    • 2002
  • Statement of problem. In-Ceram system is one of the all-ceramic crowns that can be used in anterior 3 unit fixed partial dentures and posterior single crowns. The alumina core used in In-Ceram system is manufactured using slip-casting technique. The slip-casting technique is difficult and technique sensitive. To improve this problem, tape-casting method was introduced into dentistry. There were no studies to examine the effect of margin design on the margin fitness of all-ceramic crowns fabricated from alumina tape. Purpose. The purpose of this study was to compare the marginal fitness of glass infiltrated alumina core fabricated from aqueous-based alumina tape according to different margin types ($90^{\circ},\;110^{\circ},\;135^{\circ}$ shoulder margin). Material and method. Three upper central resin incisors were prepared with $90^{\circ},\;110^{\circ}$, and $135^{\circ}$ shoulder margins for all-ceramic crowns, respectively. The resin teeth were duplicated and master die and special plaster die were made as usual. After alumina cores were fabricated from aqueous-based alumina tape, cores were cemented to each 15 epoxy dies replicated from three resin teeth with resin cement. These cemented cores were embedded in epoxy resin. Specimens were cut mesiodistally and buccolingually. Marginal gap and discrepancy were measured under microscope. Results. The marginal gap and discrepancy of $90^{\circ}$ marginal angle was $75.1{\mu}m,\;86.6{\mu}m,\;110^{\circ}$ marginal angle was $41.5{\mu}m,\;50.7{\mu}m$ and $135^{\circ}$ marginal angle was $51.7{\mu}m,\;54.2{\mu}m$, respectively. The smallest value was seen in 110 (angle, which was statistically significant compared to that of $90^{\circ}$ angle (p<0.05). Conclusion. Marginal fitness of alumina cores made of alumina tape with $110^{\circ}$ shoulder margin was best and others were clinically acceptable.

3D Simulation of Dental Implant Surgery Using Surgical Guide Stents (식립 보조도구를 이용한 3D 치아 임플란트 시술 시뮬레이션)

  • Park, Hyung-Wook;Kim, Myong-Soo;Park, Hyung-Jun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.3
    • /
    • pp.216-226
    • /
    • 2011
  • Surgeon dentists usually rely on their experiential judgments from patients' oral plaster casts and medical images to determine the positional and directional information of implant fixtures and to perform drilling tasks during dental implant surgical operations. This approach, however, may cause some errors and deteriorate the quality of dental implants. Computer-aided methods have been introduced as supportive tools to alleviate the shortcomings of the conventional approach. In this paper, we present an approach of 3D dental implant simulation which can provide the realistic and immersive experience of dental implant information. The dental implant information is primarily composed of several kinds of 3D mesh models obtained as follows. Firstly, we construct 3D mesh models of jawbones, teeth and nerve curves from the patient's dental images using software $Mimics^{TM}$. Secondly, we construct 3D mesh models of gingival regions from the patient's oral impression using a reverse engineering technique. Thirdly, we select suitable types of implant fixtures from fixture database and determine the positions and directions of the fixtures by using the 3D mesh models and the dental images with software $Simplant^{TM}$. Fourthly, from the geometric and/or directional information of the jawbones, the gingival regions, the teeth and the fixtures, we construct the 3D models of surgical guide stents which are crucial to perform the drilling operations with ease and accuracy. In the application phase, the dental implant information is combined with the tangible interface device to accomplish 3D dental implant simulation. The user can see and touch the 3D models related with dental implant surgery. Furthermore, the user can experience drilling paths to make holes where fixtures are implanted. A preliminary user study shows that the presented approach can be used to provide dental students with good educational contents. With future work, we expect that it can be utilized for clinical studies of dental implant surgery.

An Indoor Propagation Modeling that can Analyze a Fading Characteristic (페이딩 분석이 가능한 실내 전파 모델링)

  • Seok, Woo-Chan;Kim, Jin-Woong;Yoon, Young-Joong;Seok, Jae-Ho;Lim, Jae-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1B
    • /
    • pp.114-124
    • /
    • 2002
  • In this paper, we proposed the image-based 3D ray tracing indoor propagation model using a patch scattering model for fading analysis of indoor propagation environments. An image-based 3D ray tracing technique is mainly used, which allows the rapid generation of the complex channel impulse response for any given location and polarization of transmitter and receiver. Due to the site specific nature of indoor environment, we took into account the location and the electrical properties of individual walls and objects such as windows, doors and plaster board in our propagation model. Besides, the 3D radiation beam-patterns and polarizations of arbitrary antennas were considered, and using patch scattering model we can consider the change of the polarization due to the scattering from the various indoor objects, like desks, chairs and etc. the are almost impossible to be modeled with the basic image-based ray tracing method. The model will predict the impulse response, the rms delay spread, the fading characteristics of the channel and performances of the polarization diversity schemes.

Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans

  • Kontis, Panagiotis;Guth, Jan-Frederik;Schubert, Oliver;Keul, Christine
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.316-326
    • /
    • 2021
  • PURPOSE. Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla. MATERIALS AND METHODS. A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference dataset (REF). Intraoral scans using Cerec Primescan AC (PRI) and Cerec AC Omnicam (OMN), as well as conventional impressions (scannable polyvinyl siloxane) were carried out (n = 25). Conventional impressions (E5I) and referring plaster casts were scanned with the inEOS X5 (E5M). All datasets were exported in STL and analyzed (Geomagic Qualify). Linear and angular differences were evaluated by virtually constructed measurement points in the centers of the hemispheres (P13, P17, P23, P27) and lines between the points (P17-P13, P17-P23, P17-P27). Kolmogorov-Smirnov test and Shapiro-Wilk test were performed to test for normal distribution, Kruskal-Wallis-H test, and Mann-Whitney-U test to detect significant differences in trueness, followed by 2-sample Kolmogorov-Smirnov test to detect significant differences in precision (P < .008). RESULTS. Group PRI showed the highest trueness in linear and angular parameters (P < .001), while group E5I showed the highest precision (P < .001). CONCLUSION. Intraoral scan data obtained using Primescan showed the highest trueness while the indirect digitization of impressions showed the highest precision. To enhance the workflow, indirect digitization of the impression itself appears to be a reasonable technique, as it combines fast access to the digital workflow with the possibility of functional impression of mucosal areas.

Ultrasonic Reflection Imaging for Discontinuity Detection of Rock Mass - Laboratory Study (암반 불연속면 탐측을 위한 초음파 반사 이미지 - 실내실험)

  • Lee, Jong-Sub;Kim, Seung-Sun;Kim, Dong-Hyun;Kim, Uk-Young;Lee, In-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.1
    • /
    • pp.51-65
    • /
    • 2007
  • The purpose of this study is the development and application of a high resolution ultrasonic wave imaging system to detect discontinuity plane in lab-scale rock models. This technique is based on received time series which capture the multiple reflections at interface. This study includes the fundamental aspects of ultrasonic wave propagation in rock mass, the selection of the optimal ultrasonic wave transducer, data gathering, a signal processing, imaging methods, and experiments. Experiments are carried out by the horizontal movement and rotation devices. Experimental studies show the discontinuity is well detected by the horizontal movement and rotation devices under water. Furthermore, the discontinuity and the cavity on the plaster block are identified by the rotation device. This study suggests that the new method may be an economical and effective tool for the detection of the discontinuity on rock mass.