• 제목/요약/키워드: Plaster Technique

검색결과 41건 처리시간 0.03초

산릉.영건의궤 분석을 통한 조선시대 건축에서 회벽의 존재 여부 고찰 -조선 후기 관영건축을 중심으로- (A Study on the Existence of Lime Plaster Wall in the Joseon Dynasty, Based on the Analysis of Construction Reports of 'Sanleong-Uigwe' & 'Yeonggeon-Uigwe' - Emphasized on the Government Building Constructions -)

  • 이권영
    • 건축역사연구
    • /
    • 제19권3호
    • /
    • pp.89-106
    • /
    • 2010
  • Since the 1970's, UNESCO and ICOMOS have adopted or emphasized on the principles of historic preservation. One of them is what to require a repair should not be repaired beyond the limits of the features and techniques which had been adopted in those days of establishment. On the premise, this paper is to examine the materials and technique of wall plaster work in the government building constructions in the Joseon dynasty. The result of this examination shall come up with a basic conformity in the case of repairing the building established in the late of Joseon dynasty. This paper is carried out for the proper repair and restoration of architectural cultural properties. Construction reports and other documents in those days are examined for the study. Following conclusions have been reached through the study. The materials and technique which applied to wall plaster work in those days were quite different from the present. The technique that was used to wall plaster of government buildings in those days was not a lime wall plaster, but sand coat one. The kinds of material for setting of the sand coat wall plaster had been revised with the change of the times or constructions. The main kinds of material were composed of sand, white clay, paper fiber, and cereal starch. However, the present materials were composed of sand, white clay. Therefore, the present materials and technique which applied to wall plaster work for the repair and restoration of architectural cultural properties have to be revised and corrected.

조선후기 관영건축공사의 회(灰)미장재와 공법에 관한 연구 - 영건의궤(營建儀軌)의 유회(油灰), 수회(水灰), 양상도회(樑上塗灰)를 중심으로 (A Study on the Materials and Technique of Lime Plaster Work in Government Constructions in the Late of Joseon Dynasty(17~19c) - Focused on the Lime Plaster Materials in 'Yeonggeon-Uigwe'(Construction Reports) -)

  • 이권영
    • 건축역사연구
    • /
    • 제18권4호
    • /
    • pp.63-79
    • /
    • 2009
  • Since the 1970's, UNESCO and ICOMOS have adopted or emphasized on the principles of historic preservation. One of them is what to require a repair have not to be repaired beyond the limits of the features and techniques to have been born in those days of establishment. On the premise, this paper is to examine the materials and technique of lime plaster work in order for roof ridge, and for bond paste of stones and bricks in government constructions in the late of Joseon dynasty(17~19c). The result of this examination will come up with a basic conformity in the case of repairing the building established in the late of Joseon dynasty. This paper is carried out for the proper repair and restoration of architectural cultural properties. Construction reports and other documents in those days are examined for the study. Following conclusions have been reached through the study. The components of old plaster mixtures which agglutinate stones each other were quicklime, perilla oil, and paper fiber. The components of old plaster mixtures which point joint of black bricks consisted of slaked lime, perilla oil, paper fiber, and cereal starch. These components were the same as coat surface of roof ridges. In the case of times, one of the following sand, white clay, sap of boiled elm bark was added to these components for the purpose of high efficiency. These materials and techniques which applied to plaster work of those buildings had developed in the process of making royal tombs. But these materials and techniques were quite different from the present.

  • PDF

나뭇잎을 모티브로 한 색유리 플래스터 방염기법 실험과 도자화병 융합에 관한 연구 (A Study on the Colored Glass Plaster Resist Printing Technique Experiment and the Porcelain Vase Fusion with the Motif of Leaf)

  • 김승만;이정석
    • 한국콘텐츠학회논문지
    • /
    • 제19권4호
    • /
    • pp.663-674
    • /
    • 2019
  • 자연의 소재인 나뭇잎을 모티브로 하여 새롭게 개발한 색유리 플래스터 기법과 방염기법을 실험하고 도자화병과 융합하여 새롭고 독특한 데코레이션이 가미된 인테리어 화병을 만드는 것이 이번 연구의 배경이다. 이를 위한 연구 개발 방법은 첫 번째 색유리 플래스터 기법을 설명한다. 두 번째 방염기법을 설명하고 데코레이션 방법을 연구한다. 세 번째 화병의 역사와 종류를 알아보고 네 번째 16개의 화병을 현대적으로 디자인 하고 나뭇잎을 활용하여 백자토와 청자토로 산화와 환원으로 실험하여 결과를 설명한다. 이 실험결과를 통해 요변에 의한 특이한 색감 표출의 결과를 얻었고 나뭇잎 주변에 부드럽고 따뜻한 갈색 계열의 방염 그라데이션이 형성 되었다. 이러한 독특한 실험 효과를 이용하여 생활 인테리어 자기와 조형자기, 산업자기에 확장하고 응용하면 좋은 효과와 결과를 얻을 것을 기대한다.

Proximal ligation after the side-to-end anastomosis recovery technique for lymphaticovenous anastomosis

  • Suzuki, Yushi;Sakuma, Hisashi;Ihara, Jun;Shimizu, Yusuke
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.344-349
    • /
    • 2019
  • Background Lymphaticovenous anastomosis is an important surgical treatment for lymphedema, with lymphaticovenous side-to-end anastomosis (LVSEA) and lymphaticovenous end-to-end anastomosis being the most frequently performed procedures. However, LVSEA can cause lymphatic flow obstruction because of regurgitation and tension in the anastomosis. In this study, we introduce a novel and simple procedure to overcome this problem. Methods Thirty-five female patients with lower extremity lymphedema who underwent lymphaticovenous anastomosis at our hospital were included in this study. Eighty-five LVSEA procedures were performed, of which 12 resulted in insufficient venous blood flow. For these 12 anastomoses, the proximal lymphatic vessel underwent clipping after the anastomotic procedure and the venous inflow was monitored. Subsequently, the proximal ligation after side-to-end anastomosis recovery (PLASTER) technique, which involves ligating the proximal side of the lymphatic vessel, was applied. A postoperative evaluation was performed using indocyanine green 6 months after surgery. Results Despite the clipping procedure, three of the 12 anastomoses still showed poor venous inflow. Therefore, it was not possible to apply the PLASTER technique in those cases. Among the nine remaining anastomoses in which the PLASTER technique was applied, three (33%) were patent. Conclusions Our findings show that achieving patent anastomosis is challenging when postoperative venous inflow is poor. We achieved good results by performing proximal ligation after LVSEA. Thus, the PLASTER technique is a particularly useful recovery technique when LVSEA does not result in good run-off.

Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Ji-Hwan;Kim, Hae-Young
    • 대한치과교정학회지
    • /
    • 제44권2호
    • /
    • pp.69-76
    • /
    • 2014
  • Objective: This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods: Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of interexaminer and inter-method variability. Results: The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions: The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.

Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts

  • Yousefi, Faezeh;Shokri, Abbas;Zahedi, Foozie;Farhadian, Maryam
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.429-438
    • /
    • 2021
  • Purpose: This study investigated the accuracy of laser-scanned models and 3-dimensional(3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. Materials and Methods: CBCT scans and plaster models from 30 patients were retrieved. Plaster models were scanned by an Emerald laser scanner (Planmeca, Helsinki, Finland). Sixteen different measurements, encompassing the mesiodistal width of teeth and both arches' length and width, were calculated using various landmarks. Linear measurements were made on laser-scanned models using Autodesk Meshmixer software v. 3.0 (Autodesk, Mill Valley, CA, USA), on 3D-rendered CBCT models using OnDemand 3D v. 1.0 (Cybermed, Seoul, Korea) and on plaster casts by a digital caliper. Descriptive statistics, the paired t-test, and intra- and inter-class correlation coefficients were used to analyze the data. Results: There were statistically significant differences between some measurements on plaster casts and laser-scanned or 3D-rendered CBCT models (P<0.05). Molar mesiodistal width and mandibular anterior arch width deviated significantly different from the gold standard in both methods. The largest mean differences of laser-scanned and 3D-rendered CBCT models compared to the gold standard were 0.12±0.23 mm and 0.42±0.53 mm, respectively. Most of the mean differences were not clinically significant. The intra- and inter-class correlation results were acceptable for all measurements(>0.830) and between observers(>0.801). Conclusion: The 3D-rendered CBCT images and laser-scanned models were useful and accurate alternatives to conventional plaster models. They could be used for clinical purposes in orthodontics and prostheses.

친환경 미장재료로서 사벽재료를 혼입한 모르타르 및 벽체의 기초적 물성 (Fundamental Properties of Mortar and Wall Sand Coat Wall Materials Mixed with Eco-Friendly Plaster Material)

  • 료효개;김동훈;임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.133-134
    • /
    • 2017
  • The In the experiment on flow using sand walls, when white clay+sand was mixed with glutinous rice, traditional paper and seaweed as adherents and preventive measures for cracks, the flow was higher than other sand wall mortars. This indicates that it is effective in improving flow. Moreover, in terms of strength, a mix of white clay+sand, traditional paper and flour had a greater strength than a mix of white clay+sand, straws and flour. In the experiment to test for cracks and shrinking during drying, a composition of white clay+sand+traditional paper showed fewer cracks and less shrinking than the walls where straws were mixed in.

  • PDF

두개골 성형술에서 석고와 신속조형모델을 이용한 간단한 Methylmethacrylate 삽입물 제작법 (Easy Molding Technique of Methylmethacrylate Implant Using Plaster and Rapid Prototyping Model in Cranioplasty)

  • 박기린;김용하;김태곤;이준호;하주호
    • 대한두개안면성형외과학회지
    • /
    • 제13권2호
    • /
    • pp.125-129
    • /
    • 2012
  • Purpose: Methylmethacrylate is the most commonly used alloplastic material in cranioplasty. However during the polymerization of methylmethacrylate, a significant exothermic reaction takes place. This reaction may result in thermal injury to the brain tissue and other soft tissues. Also it is difficult to make three-dimensional methylmethacrylate implant that is perfectly matched to the defect during the operation time. We report on the molding technique of methylmethacrylate implant using plaster mold and the rapid prototyping model in cranioplasty. Methods: A 44-year-old male was referred to the department for severe frontal hollowness. He was involved in an automobile accident resulting in large frontal bone defect with irregular margin. The preformed patient-specific methylmethacrylate implant was made using plaster mold and the rapid prototyping model before the operative day. The methylmethacrylate implant was placed in the frontal defect and rigidly fixed with miniplates and screws on the operative day. Results: The operation was performed in an hour. In the 6 months follow-up period, there were no complications. Patient was satisfied with the results of cranioplasty. Conclusion: Safe cranioplasty was performed with the preformed patient-specific methylmethacrylate implant using plaster mold and the rapid prototyping model. The result of this method was satisfactory, aesthetically and functionally.

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Lee, Sang-Jik;Cho, Sung-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.177-185
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

Seismic improvement of infilled nonductile RC frames with external mesh reinforcement and plaster composite

  • Kamanli, Mehmet;Korkmaz, Hasan H.;Unal, Alptug;Balik, Fatih S.;Bahadir, Fatih;Cogurcu, Mustafa T.
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.761-778
    • /
    • 2015
  • The objective of this paper is to report the result of an experimental program conducted on the strengthening of nonductile RC frames by using external mesh reinforcement and plaster application. The main objective was to test an alternative strengthening technique for reinforced concrete buildings, which could be applied with minimum disturbance to the occupants. Generic specimen is two floors and one bay RC frame in 1/2 scales. The basic aim of tested strengthening techniques is to upgrade strength, ductility and stiffness of the member and/or the structural system. Six specimens, two of which were reference specimens and the remaining four of which had deficient steel detailing and poor concrete quality were strengthened and tested in an experimental program under cyclic loading. The parameters of the experimental study are mesh reinforcement ratio and plaster thickness of the infilled wall. The effects of the mesh reinforced plaster application for strengthening on behavior, strength, stiffness, failure mode and ductility of the specimens were investigated. Premature and unexpected failure mode has been observed at first and second specimens failed due to inadequate plaster thickness. Also third strengthened specimen failed due to inadequate lap splice of the external mesh reinforcement. The last modified specimen behaved satisfactorily with higher ultimate load carrying capacity. Externally reinforced infill wall composites improve seismic behavior by increasing lateral strength, lateral stiffness, and energy dissipation capacity of reinforced concrete buildings, and limit both structural and nonstructural damages caused by earthquakes.