• 제목/요약/키워드: Plasma arc curing units

검색결과 15건 처리시간 0.028초

Comparison of light transmittance in different thicknesses of zirconia under various light curing units

  • Cekic-Nagas, Isil;Egilmez, Ferhan;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권2호
    • /
    • pp.93-96
    • /
    • 2012
  • PURPOSE. The objective of this study was to compare the light transmittance of zirconia in different thicknesses using various light curing units. MATERIALS AND METHODS. A total of 21 disc-shaped zirconia specimens (5 mm in diameter) in different thicknesses (0.3, 0.5 and 0.8 mm) were prepared. The light transmittance of the specimens under three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) was compared by using a hand-held radiometer. Statistical significance was determined using two-way ANOVA (${\alpha}$=.05). RESULTS. ANOVA revealed that thickness of zirconia and light curing unit had significant effects on light transmittance ($P$ <.001). CONCLUSION. Greater thickness of zirconia results in lower light transmittance. Light-emitting diodes light-curing units might be considered as effective as Plasma arc light-curing units or more effective than Quartz-tungsten-halogen light-curing units for polymerization of the resin-based materials.

가시광선과 플라스마 광선에 의한 복합레진 중합시 미세누출과 미세경도에 관한 연구 (THE COMPARATIVE STUDY OF THE MICROHARDNESS AND MICROLEAKAGE IN POLYMERIZATION OF COMPOSITE RESIN CURED WITH VISIBLE LIGHT AND PLASMA ARC CURING UNITS)

  • 김상배;이광수
    • 대한소아치과학회지
    • /
    • 제29권2호
    • /
    • pp.180-188
    • /
    • 2002
  • 최근에 소개된 plasma arc curing units는 비교적 높은 광 강도를 가지고 짧은 시간내에 복합레진을 적절히 중합시킨다고 한다. 이 연구는 plasma arc curing units의 강한 광도와 짧은 시간에 의한 중합이 복합레진에 미치는 영향을 평가하기 위해 기존의 가시광선 중합기를 대조군으로 하여 표면 미세경도와 5급 수복물의 변연에 나타나는 미세누출을 색소침투방법으로 측정, 분석하여 다음과 같은 결론을 얻었다. 1. 각 깊이에서의 미세경도는 AHL군이 AP3, AP6군보다 모든 깊이에서 높았고, ZHL군보다 ZP6군이 표면에서 더 높았으며(P<0.05), 1mm와 2mm에서는 차이가 없었다(P>0.05). 그 외 모든 깊이에서 ZHL군이 ZP3, ZP6군보다 높았다(P<0.05). 2. 각 중합방법내 깊이에 따른 미세경도는 AHL군의 표면-1mm와 ZHL군의 1mm-2mm를 제외하고는 모든 군에서 깊이에 따라 감소되었다(P<0.05). 3. 교합면측과 치경부측 미세누출은 모든 중합군에서 교합면측이 낮게 나타났지만 유의한 차이는 없었다(P>0.05). 4. 중합방법간 미세누출은 모든 군에서 차이가 없었다(P>0.05). 5. 각 중합방법에 따른 재료간의 미세누출은 차이가 없었다(P>0.05).

  • PDF

상아질을 통한 플라즈마 아크 광중합기의 온도 전달 (TEMPERATURE TRANSMISSION OF PAC UNIT THROUGH DENTIN)

  • 박호원;김지훈
    • 대한소아치과학회지
    • /
    • 제30권4호
    • /
    • pp.707-714
    • /
    • 2003
  • 플라즈마 아크 광중합기 (Plasma Arc Curing units)는 상대적으로 높은 광강도를 발생시켜 짧은 중합시간으로 복합레진이 충분한 중합강도에 도달할 수 있게 해준다. 시술시간의 단축이라는 점에서 소아치과에서는 최근에 플라즈마 아크 광중합기를 많이 사용하고 있으나, 플라즈마 아크 광중합기는 광조사 동안 많은 열을 발생시킬 수 있다. 본 연구에서는 2종류의 플라즈마 아크 광중합기(Flipo, Q-Lux plasma 100)를 이용하여 여러 두께의 상아질 시편과 중합된 복합레진 시편을 통해 전달되는 온도를 측정하고 비교하였다. 본 연구의 결과는 다음과 같다. 1. 플라즈마 아크 광중합기를 연속적으로 조사하였을 때, 중합기의 조사단에서 측정된 온도는 조사시간이 증가함에 따라 증가하였고, Q-lux에서 Flipo보다 더 큰 온도 증가를 보였다(p<.0.001). 2. 상아질 시편의 두께에 따른 온도 변화에서, 상아질 시편의 두께가 증가함에 따라 온도 증가량은 감소되었다(p<0.05). 3. 복합레진 시편의 두께에 따른 온도 변화에서, 복합레진 시편의 두께가 증가함에 따라 온도 증가량은 감소되었다(p<0.05).

  • PDF

광원에 따른 조사거리의 증가가 복합레진의 중합도에 미치는 영향 (INFLUENCE OF TIP DISTANCE ON DEGREE OF CONVERSION OF COMPOSITE RESIN IN CURING WITH VARIOUS LIGHT SOURCES)

  • 김상배;박호원
    • 대한소아치과학회지
    • /
    • 제31권2호
    • /
    • pp.273-279
    • /
    • 2004
  • 최근에 소개된 single high-intensity LED 중합기는 이전의 LED 중합기에 비해 높은 광도를 가지며 짧은 중합시간에 적절한 물성을 가질 수 있다고 한다. 본 연구는 single high-intensity LED 중합기의 중합성능을 평가하기 위하여 거리에 따른 중합도를 조사하였다. Mylar strip사이에 복합레진(Filtek Z250)을 넣고 압접시켜 만든 얇은 필름형 시편을 LED 중합기(Elipar Freelight 2, 10초), 플라스마 중합기(Flipo, 6초)와 할로겐 중합기 (XL3000, 20초)를 사용해 0mm, 2mm, 4mm, 6mm에서 광도를 측정하고 중합시켰다. 중합된 시편을 Fourier Transform Infrared Spectrometer(FTIR)를 이용해 중합도를 측정한 후 다음과 같은 결론을 얻었다. 1. 모든 중합기에서 거리가 증가할수록 유의하게 광도가 감소하였으며 LED중합기의 경우 6mm에서 다른 중합기에 비해 가장 많은 광도 감소율을 보였다(p<0.05). 2. 모든 중합기에서 거리가 증가함에 따라 4mm까지는 중합도가 감소하였지만 유의한 차이는 보이지 않았다(p>0.05). 하지만 4mm와 6mm사이에서는 모든 중합기에서 유의하게 감소하였다(p<0.05). 3. 각 거리에 따른 중합기간의 중합도 차이는 0mm, 2mm, 4 mm에서 LED중합기가 다른 중합기보다 유의하게 높은 중합도를 보였으며 (p<0.05) 플라스마 중합기와 할로겐 중합기 사이에서는 유의한 차이가 없었다. 하지만 6 mm에서는 모든 중합기 사이에 유의한 차이를 보이지 않았다(p>0.05).

  • PDF

Plasma arc light를 이용한 금속 브라켓의 부착시 광조사 방향과 중합시간이 전단결합강도에 미치는 영향 (Effects of light direction and exposure times of plasma arc light on shear bond strength of metal brackets)

  • 노상정;이현정;전영미;김정기
    • 대한치과교정학회지
    • /
    • 제34권5호
    • /
    • pp.429-438
    • /
    • 2004
  • 본 연구는 Plasma arc light를 이용하여 금속 브라켓의 부착시 광조사 방향, 중합시간 그리고 경화시간이 전단결합강도에 미치는 영향을 평가하기 위해서 시행되었다. 240개의 발거된 소구츠를 16군으로 나눈 후. 광중합기(Plasma arc light와 Halogen light), 중합시간(Plasma arc light 2. 4. 6초와 Halogen light 20초). 그리고 광조사 방향(Vertical 방향과 Oblique 방향)을 다르게 하여 브라켓을 부착하였다. 광증합 접착제는 Transbond XT를 이용하였으며 브라켓 부착 후 5분과 24시간 후에 만능물성시험기를 이용하여 전단결합강도를 측정하였다. 결과는 다음과 같다. 광중합기의 종류와 중합시간에 관계없이 Vertical군과 Oblique군간의 전단결합강도는 유의한 차이가 없었다.(p>0.05) Plasma arc light를 이용하여 2초 동안 광중합한 군들의 전단결합강도는 다른 중합시간의 군들보다 현저히 낮았다(P<0.05). 부착 5분 후의 전단결합강도는 24시간 후보다 현저히 낮았다(P<005), ARI 점수는 군들 간에 통계적으로 유의한 차이가 없었다. 이상의 결과는 plasma arc light를 사용한 금속 브라켓의 부착시 광조사 방향은 전단결합강도에 영향을 끼치지 않으며. Halogen light와 유사한 결합강도를 얻기 위해서는 4초 이상의 중합시간이 필요함을 시사한다.

Effect of light source on depth of cure and polymerization shrinkage of composites

  • Na, Joon-Sok;Oh, Won-Mann;Hwang, In-Nam
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.578.1-578
    • /
    • 2001
  • The aim of this study was to evaluate the efficiency of the recently introduced light curing units to polymerize a light curing resin composite. Four light curing units XL 3000, Optilux 500 for halogen light source, Apollo 95E for plasma arc and Easy cure for LED (blue-light Emitting Diode) were evaluated. Radiometer was used for measure the light intensity.(omitted)

  • PDF

각각의 광조사기가 복합레진의 미세경도와 미세누출에 미치는 영향 (EFFECT OF EACH LIGHT CURING UNITS ON THE MICROHARDNESS AND MICROLEAKAGE OF COMPOSITE RESIN)

  • 정유진;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권1호
    • /
    • pp.58-67
    • /
    • 2004
  • The objectives of this study was to evaluate current visible light curing units regarding microhardness and microleakage. Fourty samples of composite resin(Z-250, 3M) were cured by different light curing units (Flipo, LOKKI; Credi II, 3M; XL 3000, 3M: Optilux 500, Demetron) in acrylic blocks. Microhardness was measured using a calibrated Vickers indenter on both top and bottom surfaces after 24 hours of storage in air at room temperature. Class V cavities were prepared on buccal and lingual surfaces of fourty extracted human molars. Each margin was on enamel and dentin/cementum. Composite resin(Z-250, 3M) was filled in cavities and cured by four different light curing units (Flipo, LOKKl; Credi II, 3M; XL 3000, 3M: Optilux 500, Demetron). The results of this syudy were as follows: Microhardness 1. Flipo showed low microhardness compared to Optilux 500, Credi II significantly in upper surface. Flipo didn't show a significant difference compared to XL 3000. 2. The microhardness resulting from curing with Flipo was lower than that of others on lower surfaces. Microleakage 1. Dentin margin showed significantly high dye penetration rate than enamel margin in all groups(p<0.05). 2. No significant differences were found on both enamel and dentin margin regarding curing units.

플라즈마 광중합기가 복합레진 중합에 미치는 영향 (Effects of plasma arc curing lights on the surface hardness of the composite resins)

  • 이수원;양규호;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.624-632
    • /
    • 2006
  • 기존에 사용하고 있는 할로겐 광중합기는 여러 가지 장점에도 불구하고 중합시간이 오래 걸린다는 문제 때문에 시술시간이 길어지는 단점이 있는데, 최근에 개발된 플라즈마 광중합기는 매우 짧은 시간에 중합시킬 수 있다고 제조회사는 주장하고 있다. 본 연구에서는 임상에서 흔히 상용하고 있는 복합 레진을 광중합 할 때, 할로겐 광중합으로 얻을 수 있는 플라즈마 광중합기의 적절한 중합시간을 알아보고자 한다. 2mm 두께의 레진 샘플을 만들어 광중합 하고 24 시간 후 상, 하면의 미세경도를 측정하였다. point $4^{(R)}$에서는 플라즈마 광중합기로 6초간 중합했을 때 할로겐과 유사한 경도를 얻었지만, $Z250^{(R)}$에서는 $Flipo^{(R)}$만 9초간 중합시 할로겐과 유사한 광중합을 나타냈다. 이번 연구에서 사용한 플라즈마 광중합기는 적어도 6초 혹은 9초정도 광중합 했을 때 할로겐과 유사한 중합을 얻을 수 있다는 것을 알 수 있었다.

  • PDF

수종의 광중합기를 이용한 교정용 광중합형 글라스 아이오노머 시멘트의 전단 결합 강도에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTHS OF VISIBLE LIGHT-CURED GLASS IONOMER CEMENT WITH SEVERAL LIGHT-CURING UNITS)

  • 김민수;유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.81-90
    • /
    • 2007
  • 본 연구에서는 세 가지 서로 다른 광원(할로겐 램프 :. Elipar Trilight ; 3M ESPE, Seefeld, Germany, Light Emitting Diode (LED) ; Elipar Freelight2 ; 3M ESPE, Seefeld, Germany, 플라즈마 광 : Flipo ; LOKKI, France)을 사용하여 브라켓과 광원사이의 거리에 따른 광중합형 글라스 아이오노머 시멘트(Fuji ORTHO LC : GC, Japan)의 전단 결합 강도를 알아보고자 하였다. 1. 광중합기에 따른 전단 결합 강도는 광중합기로부터 브라켓까지의 거리가 0mm일 때 3가지 광원에 유의할 만한 차이는 보이지 않았고 광중합기로부터 브라켓까지의 거리가 3mm, 6mm일 때, 할로겐 광과 플라즈마 광 사이에는 유의할 만한 차이가 없었으나 LED 광은 유의성 있게 낮은 전단 결합 강도를 나타냈다. 2. 할로겐 광과 플라즈마 광으로 광중합시 거리에 따른 전단 결합 강도에 유의한 차 없었고 LED광을 사용하여 광중합시에는 거리가 증가할수록 전단 결합 강도가 감소하였다. 특히 0mm에서 3mm로 거리가 증가시 유의할 만한 감소를 나타내었다.

  • PDF

FTIR을 이용한 복합레진의 중합도 비교 (THE COMPARISON OF LIGHT-CURED COMPOSITE RESIN POLYMERIZATION BY FTIR)

  • 이주현;박호원
    • 대한소아치과학회지
    • /
    • 제30권2호
    • /
    • pp.245-253
    • /
    • 2003
  • 치과용 복합레진의 중합률은 레진 기질내의 이중결합의 전환도를 나타내는 것으로 이는 재료의 물리적 성질과 기계적 성질 및 생체 친화성에 영향을 미친다. 레진의 중합도가 증가하면 취성과 수축이 증가하고 중합도가 낮으면 기계적 물리적 성질이 감소한다. 따라서 본 연구에서는 광중합형 복합레진을 사용하여 플라즈마 아크 중합기 2종, 할로겐 중합기 2종, LED 중합기 2종, pulse-delay curing의 서로 다른 중합방법의 경우를 FTIR 분석법으로 복합레진의 물리적 기계적 성질 및 생체친화성에 영향을 미치는 중합률을 분석하여 다음과 같은 결과를 얻었다. 1. 광중합 복합레진의 중합률은 FTIR로 측정하였을 때 34.52-49.31%사이로 나타났으며 플라즈마 아크 중합의 경우 Flipo는 $39.96{\pm}1.22%$, CrediII는 $45.64{\pm}1.34%$로, 할로겐 중합시 XL3000은 $43.48{\pm}1.34%$, VIP의 mode 4 사용시는 $44.31{\pm}0.72%$, LED의 LUXOMAX는 $49.31{\pm}2.37%$, Elipar Freelight는 $44.51{\pm}0.62%$, pulse-delay curing시에는 $34.52{\pm}0.85%$로 나타났다. 2. 각 중합 방법별로 중합률은 LED 중합 방법을 이용한 LUXOMAX가 다른 실험군에 비하여 가장 높은 중합률을 나타냈으며 pulse-delay curing 방법이 가장 낮은 중합률을 보였다. 3. Flipo 중합기, LUXOMAX 중합기, pulse-delay curing 방법이 다른 중합기와 비교하여 통계적으로 유의한 차이를 보였다(p<0.05). 4. 각 중합방법이 동일한 군 내의 중합기기별 차이에서는 할로겐에서는 광중합기 사이에 중합률의 차이를 보이지 않았으나 플라즈마 아크에서는 CrediII가, LED에서는 LUXOMAX가 중합률이 높았다(p<0.05).

  • PDF