• Title/Summary/Keyword: Plasma Sensor

Search Result 175, Processing Time 0.028 seconds

Fabrication of an Oxide-based Optical Sensor on a Stretchable Substrate (스트레처블 기판상에 산화물 기반의 광센서 제작)

  • Moojin Kim
    • Journal of Industrial Convergence
    • /
    • v.20 no.12
    • /
    • pp.79-85
    • /
    • 2022
  • Recently, a smartphone manufactured on a flexible substrate has been released as an electronic device, and research on a stretchable electronic device is in progress. In this paper, a silicon-based stretchable material is made and used as a substrate to implement and evaluate an optical sensor device using oxide semiconductor. To this end, a substrate that stretches well at room temperature was made using a silicone-based solution rubber, and the elongation of 350% of the material was confirmed, and optical properties such as reflectivity, transmittance, and absorbance were measured. Next, since the surface of these materials is hydrophobic, oxygen-based plasma surface treatment was performed to clean the surface and change the surface to hydrophilicity. After depositing an AZO-based oxide film with vacuum equipment, an Ag electrode was formed using a cotton swab or a metal mast to complete the photosensor. The optoelectronic device analyzed the change in current according to the voltage when light was irradiated and when it was not, and the photocurrent caused by light was observed. In addition, the effect of the optical sensor according to the folding was additionally tested using a bending machine. In the future, we plan to intensively study folding (bending) and stretching optical devices by forming stretchable semiconductor materials and electrodes on stretchable substrates.

Improving Hot Spot Problem in Layer of DL-LEACH

  • LEE, WooSuk;Jin, Seung Yeon;Jung, Kye-Dong;Lee, Jong-Yong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.2
    • /
    • pp.64-69
    • /
    • 2017
  • The abstract should summarize the contents of the paper and written below the author information. Use th In Wide-area Wireless Sensor Networks, network lifetime is short due to energy consumption due to transmission distance. To improve this, we divide the sensor field into layers and reduce transmission distance through multi-hop transmission. However, there is a problem in that the transmission rate drops because there is no Cluster Head in the layer, or the transmission distance increases due to the layer, and energy is wasted. There are DL-LEACH and EDL-LEACH as Protocols to improve this. DL-LEACH uses either single-hop transmission or multi-hop transmission depending on the situation. As a result, the transmission distance is optimized, thereby reducing energy consumption. In case of EDL-LEACH, it is proposed to improve the data rate in DL-LEACH. It is the same as DL-LEACH, but the Cluster Head is mandatory for all layers to improve the transmission rate. Although there is no Cluster Head for each layer, the transmission rate is improved, but the network life is shortened. In this paper, we try to improve the network lifetime while maintaining the EDL-LEACH transmission rate. The shortened network lifetime is due to Cluster Head overload near the base station. To improve this, the Cluster Head distribution method is improved and the network lifetime is improved.

Reliability Improvement of the Electro Optical Tracking System by using DLC Films (DLC 박막을 통한 전자광학추적장비 신뢰성 개선)

  • Shim, Bo-Hyun;Jo, Hee-Jin;Kim, Jang-Eun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.197-205
    • /
    • 2015
  • The Diamond Like Carbon(DLC) films for the Electro Optical Tracking System(EOTS) by using Plasma Enhanced Chemical Vapor Deposition(PECVD) method is presented. We achieve that the DLC films can reduce the surface delamination of thermal observation sensor front window due to the high hardness, low friction and chemical inertness which is comparable to a Si film. According to our experiment results, DLC films can be used for various electro optical systems to eliminate surface delamination.

The Gyro High Voltage Power Supply Design for Attitude Control in the Satellite (저궤도 위성 자세제어용 자이로 고전압 발생기 설계)

  • Kim, Eui-Chan;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.403-408
    • /
    • 2008
  • The gyroscope is the sensor for detecting the rotation in inertial reference frame and constitute the navigation system together an accelerometer. As the inertial reference equipment for attitude determination and control in the satellite, the mechanical gyroscope has been used but it bring the disturbance for mass unbalance so the disturbance give a bad influence to the observation satellite mission because the mechanical gyroscope has the rotation parts. During the launch. The mechanical gyroscope is weak in vibration, shock and has the defect of narrow operating temperature range so it need the special design in integration. Recently the low orbit observation satellite for seeking the high pointing accuracy of image camera payload accept the FOG(Fiber Optic Gyro) or RLG(Ring Laser Gyro) for the attitude determination and control. The Ring Laser Gyro makes use of the Sanac effect within a resonant ring cavity of a He-Ne laser and has more accuracy than the other gyros. It need the 1000V DC to create the He-Ne plasma in discharge tube. In this paper, the design process of the High Voltage Power Supply for RLG(Ring Laser Gyroscope) is described. The specification for High Voltage Power Supply (HVPS) is proposed. Also, The analysis of flyback converter topology is explained. The Design for the HVPS is composed of the inverter circuit, feedback control circuit, high frequency switching transformer design and voltage doubler circuit.

A Study of the Fabrication and Enhancement of Film Bulk Acoustic Wave Resonator using Two-Step Deposition Method of Piezoelectric Layer (압전층의 2단 증착법을 이용한 체적 음향파 박막형 공진기의 제작과 성능향상에 관한 연구)

  • Park Sung-Hyun;Chu Soon-Nam;Lee Neung-Heon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.7
    • /
    • pp.308-314
    • /
    • 2005
  • The 2 GHz film bulk acoustic wave resonator(FBAR), one of the most necessary device of the next generation mobile communication system, consisted of solidly mounted resonator(SMR) structure using Brags reflector, was researched in this paper The FBAR applied SiO$_{2}$ and W had large difference of the acoustic impedance to reflector Al to electrode and ZnO to piezoelectric layer. Specially, the FBAR applied the two-step deposition method to improve the c-axis orientation and increase reproducibility of the fabrication device had good performance. The electrical properties of plasma such as impedance, resistance, reactance, $V_{pp},\;I{pp}$, VSWR and phase difference of voltage and current, was analyzed and measured by RF sensor with the variable experiment process factors such as gas ratio, RF power and base vacuum level about concerning the thickness, c-axis orientation, adhesion and roughness. The FBAR device about the optimum condition resulted reflection loss(S$_{11}$) of -17 dB, resonance frequency of 1.93 GHz, electric-mechanical coefficient(k$_{eff}$) of 2.38 $\%$ and Qualify factor of 580. It was seen better qualify than the common dielectric filter at present and expected on business to the filter device of 2 GHz bandwidth with the MMIC technology.

Development of Scientific Payloads for Korea Sounding Rocket-III (3단형 과학로켓용 과학탑재체 개발)

  • Hwang, Seung Hyeon;Kim, Jun;Lee, Su Jin;Jeon, Yeong Du;Park, Jeong Ju
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.80-88
    • /
    • 2003
  • This paper describes the development of an ozone detector and an electron probe as parts of scientific payloads for sounding rockets such as the KSR-III. Each detector consists of sensor parts and electronic parts. We successfully carried out the calibration tests with developed ozone detector and the space plasma simulation chamber tests with electron detector. These payloads could be onboard the KSR-III and with measured data, it is expected and temperature profile over the Korean Peninsular.

A study on manufacturing of laser welded tube from 60kgf/$mm^2$Grade Steel Sheet for one-body forming (60kgf/$mm^2$급 일체화 성형용 레이저 용접 튜브 제조에 관한 연구)

  • Seo, Jung;Lee, Je-Hoon;Kim, Jung-Oh;Kang, Hee-Sin;Lee, Mun-Yong;Jung, Byung-Hoon
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.18-20
    • /
    • 2003
  • Optimal processing and system to produce the laser welded tube for one body formed bumper beam are studied. The calculated size of tube is a thickness of 1.4mm, diameter of 105.4mm and length of 2000mm. The tube is shaped from cool rolled high strength steel sheet(tensile strength: 60kgf/$\textrm{mm}^2$ grade). Two roll bending method is the optimal tube shaping process compared to UO-bending, bending on press brake, multi-step continuous roll forming and 3 roll bending methods. Weld quality monitoring and seam tracking along the butt-joint lengthwise to the tube axis are also studied. The longitudinal butt-joint is welded by the $CO_2$ laser welding system equipped with a seam tracker and plasma sensor. The constructed $CO_2$ laser tube welding system can be used for the precision seam tracking and the real-time monitoring of weld quality. Finally, the obtained laser welded tube can be used for one-body formed automobile bumper beam.

  • PDF

Characterization of Nafion Coated Non-enzymatic Glucose Sensor in Human Plasma and Whole Blood (나피온을 이용하여 패키징된 무효소 혈당센서의 혈장 및 전혈에서의 특성 평가)

  • Lee, Yi-Jae;Kim, Jung-Doo;Park, Jae-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1474-1475
    • /
    • 2008
  • 본 논문에서는 nanoporous Pt (Platinum) 전극을 이용한 무효소 혈당센서의 생체 적합성 및 전류응답 특성 향상을 위해 다양한 패키징 방법이 제안되었다. 생체적합성을 갖는 Nafion 멤브레인을 dipping, spin coating, chemical bonding 방법으로 패키징 한 후, 다양한 글루코오스 농도의 혈장, 전혈에서 특성을 분석, 비교하였다. 단백질 등이 포함되지 않은 환경에서 spin coating 방법으로 패키징한 센서의 전류응답 특성은 가장 좋았지만, 혈장 및 전혈에서는 dipping, chemical bonding 방법으로 패키징한 센서의 전류응답 특성에 미치지 못했다. Nafion film을 센서와 chemical bonding한 센서의 혈장에서 sensitivity 는 0.32 ${\mu}A/mM{\cdot}cm^2$ 이었다. 한편, 전혈에서 bare 센서가 급격한 bio-fouling 현상을 보이는 반면 패키징한 센서는 글루코오스 농도에 따라 일정한 전류변화를 보였다. 이는 Nafion을 이용하여 패키징한 무효소 혈당 센서가 생체환경에 적합할 뿐 아니라 생체이식형 및 연속 측정 가능한 시스템에 적용 가능함을 보여준다.

  • PDF

The RLG's Power Supply Design for Attitude Control in the Satellite (저궤도 위성 자세제어용 센서 RLG 전원 공급기 설계)

  • Kim, Eui-Chan;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1488-1490
    • /
    • 2008
  • The gyroscope is the sensor for detecting the rotation in inertial reference frame and constitute the navigation system together an accelerometer. As the inertial reference equipment for attitude determination and control in the satellite, the mechanical gyroscope has been used but it bring the disturbance for mass unbalance so the disturbance give a bad influence to the observation satellite mission because the mechanical gyroscope has the rotation parts. During the launch, The mechanical gyroscope is weak in vibration, shock and has the defect of narrow operating temperature range so it need the special design in integration. Recently the low orbit observation satellite for seeking the high pointing accuracy of image camera payload accept the FOG(Fiber Optic Gyro) or RLG(Ring Laser Gyro) for the attitude determination and control. The Ring Laser Gyro makes use of the Sanac effect within a resonant ring cavity of a He-Ne laser and has more accuracy than the other gyros. It need the 1000V DC to create the He-Ne plasma in discharge tube. In this paper, the design process of the High Voltage Power Supply for RLG(Ring Laser Gyroscope) is described. The specification for High Voltage Power Supply(HVPS) is proposed. Also, The analysis of flyback converter topology is explained. The Design for the HVPS is composed of the inverter circuit, feedback control circuit, high frequency switching transformer design and voltage doubler circuit.

  • PDF

OPTIMAL PROCESSING AND SYSTEM MANUFACTURING OF A LASER WELDED TUBE FOR AN AUTOMOBILE BUMPER BEAM

  • Suh, J.;Lee, J.H.;Kang, H.S.;Park, K.T.;Kim, J.S.;Lee, M.Y.;Jung, B.H.
    • International Journal of Automotive Technology
    • /
    • v.7 no.2
    • /
    • pp.209-216
    • /
    • 2006
  • A study has been conducted for an optimal processing and an apparatus for manufacturing a laser welded tube for one-body formed bumper beam. The tube dimensions used in calculation were the thickness of 1.4 mm, the diameter of 105.4 mm and the length of 2000 mm. The tube was formed of a cold rolled high strength steel plate(tensile strength of 600 MPa). The two-roll bending method was the optimal tube forming process in comparison with the UO-bending method, the bending method on the press brake, the multi-step continuous roll-forming method and the 3-roll bending method. Monitoring of the welding quality was conducted and the seam tracking along the butt-joint lengthwise to the tube axis was also examined. The longitudinal butt-joint was welded by using a $CO_2$ laser welding machine equipped with a seam tracker and a plasma sensor. The $CO_2$ laser tube welding machine could be used for precise seam tracking and real-time monitoring of the welding quality. As a result, the developed laser welded tube could be used for a one-body formed automobile bumper beam.