• 제목/요약/키워드: Plant design

검색결과 3,878건 처리시간 0.035초

$H_{\infty}$ 기법을 이용한 2자유도 PI 제어기 성능개선에 관한 연구 (A Study on the Performance Improvement of Two-degree of Freedom PI Controller using $H_{\infty}$ Technique)

  • 조용석;박기헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.199-202
    • /
    • 1995
  • In the conventional $H_2$ design of PI controllers, the quadratic cost function includes only the plant output term and hence, the optimal controller often results in a very large plant input. In this paper, $H_{\infty}$ design methodology is combined with the conventional $H_2$ design to make a trade-off between the regulation of the plant input and the plant output in a systematic way.

  • PDF

소수력발전소의 성능예측기법에 관한 연구 (A Study on the Performance Prediction Methodology of Small Hydropower Plant)

  • 이철형;박완순
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.742-747
    • /
    • 2005
  • A model, which can analyze the hydrological performance for small hydropower(SHP) plants having no flow duration characteristics has been studied and developed. System performance of existing SHP plant under operating was analyzed by using the developed model. The annual operational rate of SHP plant showed that the data were in good agreement with predicted results from the model. Based on these results, several SHP sites to be exploited were selected and the performance characteristics were analyzed by using the developed model. Also, primary design values such as design flow rate, plant capacity, and operational rate were suggested. As a result, it was found that the methodology used in this study is useful tool to predict the hydrological system performances of SHP sites.

  • PDF

에너지공급시설 및 환경기초시설의 복합화 방안 및 적용효과 분석 (A Study on the Design Method and the Effect Analysis for the Introduction of the Integrated System Model of Individual Urban Utility Plants)

  • 이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.235-240
    • /
    • 2005
  • Recently urban utility plants in urban areas of Korea, such as energy supply systems, municipal waste incineration systems, sewage treatment systems and so on, have caused some critical troubles, for instance the insensitive response to the seasonal or daily variation of loads, the low system efficiency and inefficient use of energy because of the large-scale system located a great distance. Therefor the design method of optimal integrated system model of various urban utility plants proposed in this study suitably to the present situation of Korea. Also, the effect analysis for the introduction of compound utility plants was studied for a new town model on a 60,000 persons scale. As the results we found that the complex plant was superior to individual urban utility plant in side of the initial investment expenses, the operating cost and other reasons.

  • PDF

플랜트 프로젝트용 3차원 디자인 시스템에서 라이브러리 개발을 통한 설계시간 감축 (Man-hour Reduction by Development of Library in a 3-D Design System for Plant Projects)

  • 이정현;문승재;유호선
    • 플랜트 저널
    • /
    • 제5권4호
    • /
    • pp.68-72
    • /
    • 2009
  • This study discussed for library development of the 3 dimensional design system for the progressive developmental world wide plant industry. Its previous background had spatial limitation by utilizing 2 dimensional CAD. This work presented an effective mode for improving man-hour by applying with 3 dimensioal design system through theoretical definition, category, and means of basic man-hour. We researched an effective method for reducing man-hour through applied example on the actual project by comprehending affection of extra development for library on man-hour.

  • PDF

원자력 발전소 AOV 구동기 설계 정립화 (A Thesis of Design Air Operated Valve Actuator in Nuclear Power Plant)

  • 최종귀;황지혁;김영범;손기철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2616-2620
    • /
    • 2008
  • AOV used fluid capacity and fluid pressure control in nuclear power plant with heating power plant. AOV structures safely must be secured the reliability and a safety of the atomic power plant. but, AOV where is used from domestic is using the product of the overseas enterprise. The AOV design and maintenance technique is insufficient. Therefore According to ASME designed AOV, The performance test resultant fluid leakage did not occur and AOV design was satisfactory.

  • PDF

DSP를 이용한 고장허용을 갖는 신뢰 적응 필터 설계 (Design of Reliable Adaptive Fitter with Fault Tolerance Using DSP)

  • 유동완;이전우;서보혁
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권1호
    • /
    • pp.8-13
    • /
    • 2001
  • LMS algorithm has been used for plant identifier and noise cancellation. This algorithm has been researched for performance enhancement of filtering. The design and development of a reliable system has been becoming a key issue in industry field because the reliability of a system is considered as an important factor to perform the system's function successfully. And the computing with reliability and fault tolerance is a important factor in the case of aviation, system communication, and nuclear plant. This paper presents design of reliable adaptive filter with fault tolerance. Generally, redundancy is used for reliability. In this case it needs computing or circuit for voting mechanism, or fault detection. Therefore it has simple computing, and practicality for application. And in this paper, reliability of adaptive filter is analyzed. The effectiveness of the proposed adaptive filter is demonstrated to the case studies of plant identifier and noise cancellation by using DSP.

  • PDF

원전 생애주기간 설계기준 정보관리를 위한 요건 분류체계 개발 (Development of Requirement Taxonomy for Design Bases Management during NPP lifecycle)

  • 김종명
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.134-135
    • /
    • 2018
  • Nuclear Power Plant consists of about 1.4 million facilities. and the design standards and design requirements for the continuos utilization and safety of facilities are complexly connected with the facilities. When a design change for facilities or design requirements is occurred at the time of construction or operation, there are a lot of facilities, design requirements, and design bases that are affected by the facilities or design bases being changed. The above design changes are so complex that the existing document-bases design change process is time-consuming and may also cause human error. In this study, we developed a design requirement taxonomy that can be applied to the data-centric design bases document that can improve it. To do this, we analyze the design elements from the highest level to the lowest level applied to the nuclear power plant, and classify the design elements according to the characteristics of the design elements.

  • PDF

The Effects of the Scope of Plant Layout Conversion on Manufacturing Cell Design Processes and Outcomes

  • Choi, Moon-Jin
    • 한국경영과학회지
    • /
    • 제18권3호
    • /
    • pp.159-177
    • /
    • 1993
  • One of major research issues in cellular manufacturing is studing factors that are fovorable or detrimental to the conversion of traditional functional layouts to GT cellular layouts. Among many factors, this paper explored plausible relationships between the scope of plant conversion and the manufacturing cell design processes and outcomes. The cell design practices of 28 U. S. plants were surveyed through a mail questionaire. While most relationships were not statistically significant, some interesting findings and insights could be drawn. With this researhc, we can better understand a part of relationships between the company's conversion strategy and the cell design strategies and outcomes.

  • PDF

A Brief Review on the Design Factors of Steam Generator U-Tube Assembly for CANDU Type Nuclear Power Plant

  • Park, Nam-Il;Park, June-Soo
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(4)
    • /
    • pp.321-326
    • /
    • 1996
  • During the plant operation, steam generator U-tube assembly will potentially be subject to adverse environmental conditions which can cause damages to them. This report addresses the major design factors of CANDU type steam generator which are intended to minimize the potential tube damages. Such factors include U-tube material, high circulation ratio, tube-to-tubesheet joint, tube support design. Also a few suggestions are presented for the design and performance improvement of CANDU type steam generators.

  • PDF

APR+ 표준설계에 대한 경제성 분석 (A Economic Evaluation for APR+ Standard Design)

  • 하각현;이재호
    • 에너지공학
    • /
    • 제25권1호
    • /
    • pp.43-47
    • /
    • 2016
  • 한수원 중앙연구원은 2007년부터 정부과제의 하나로 전기출력이 1500MWe급인 GEN III+ 원전 APR+를 개발해 왔다. APR1400 보다 안전성이 진전된 노형을 개발하기 위해 국내외에서 건설되거나 설계중인 ALWR의 개선된 설계특성을 조사하였다. 국내외의 원전건설 사업에 적합한 APR+ 표준설계를 개발하기 위해 신개념설계특성과 후쿠시마 원전사고 경험을 설계에 반영하였다. APR+의 안전성향상 표준설계 단계(2013.1 ~ 2015.12)에서 한 번의 경제성평가를 수행하였다. 설계 안전성향상 기술개발 단계에의 경제성 평가 결과 APR+ N-th호기는 국내석 탄화력 1000MWe급 대비 39.2% 경쟁력 우위인 것으로 평가되었다. 또한 APR+원전은 해외 원전 선진국 ALWR에 비해 동등 이상 수준의 경쟁력을 확보하는 것으로 평가되었다.