• Title/Summary/Keyword: Plant Evaluation

Search Result 2,883, Processing Time 0.03 seconds

Evaluation of accumulated particulate matter on roadside tree leaves and its metal content (가로수 수종별 잎의 미세먼지 축적량 및 금속 원소 함량 평가)

  • Kwon, Seon-Ju;Cha, Seung-Ju;Lee, Joo-Kyung;Park, Jin Hee
    • Journal of Applied Biological Chemistry
    • /
    • v.63 no.2
    • /
    • pp.161-168
    • /
    • 2020
  • It is known that different plant species have ability to deposit different amounts of particulate matter (PM) on their leaves and plants can absorb heavy metals in PM through their leaves. Heavy metals in PM can have toxic effect on human body and plants. Therefore, PM on different roadside trees at Chungbuk national University including box tree (Buxus koreana), yew (Taxus cuspidate), royal azalea (Rhododendron yedoense), and retusa fringetree (Chionanthus retusa) was quantified based on particle size (PM>10 and PM2.5-10). The metal concentration in PM accumulated on leaves was analyzed using inductively coupled plasma-mass spectroscopy. In this study, the mass of PM>10 deposited on the surface of the tree leaves ranged from 6.11 to 32.7 ㎍/㎠, while the mass of PM2.5-10 ranged from 0 to 14.8 ㎍/㎠. The royal azaleas with grooves and hair on the leaf surface retained PM particles for longer time, while the yews and box trees with wax on leaf surfaces accumulated more PM. The PM contained elements in crustal material such as Al, Ca, Mg, and Fe and heavy metals including Cu, Pb and Zn. The concentration of elements in crustal material was higher in the coarser size, while heavy metal concentration was relatively higher in the finer size fraction. The Mn, Cd, Cu, Ni, Pb, and Zn concentrations of leaves and PM2.5-10 were significantly correlated indicating that PM was taken up through tree leaves.

Evaluation of Ambrosia artemisiifolia var. elatior, Ambrosia trifida, Rumex crispus for phytoremediation of Cu and Cd contaminated soil (돼지풀, 단풍잎돼지풀, 소리쟁이를 이용한 중금속오염토양의 식물복원법(phytoremediation)에 관한 연구)

  • Kang, Byeung-Hoa;Shim, Sang-In;Lee, Sang-Gak;Kim, Kwang-Ho;Chung, Ill-Min
    • Korean Journal of Weed Science
    • /
    • v.18 no.3
    • /
    • pp.262-267
    • /
    • 1998
  • We evaluated Ambrosia artemisiifolia var. elatior, Ambrosia trifida, Rumex crispus which were reported to have good phytoremediatibility in different concentrations of Cu and Cd. Different growth responses were found in different heavy metal concentrations. Good growth rate for A. trifida and A. artemisiifolia var. elatior in Cu and Cd treatments and poor growth for R. crispus in Cd treatment were found. Although growth was retared in all tested weeds up to 200ppm for Cu and 50ppm for Cd, the high amount of heavy metal uptake indicated that these weeds could be used as phytoremediation. The choice of proper plant for bioremediation in different sources of heavy metal pollution seems important. In this regard, A. trifida which showed little variation in Cu accumulation in shoot under different Cu concentrations could be used for phytoremediation and phytostabilization.

  • PDF

Weed Control and Safety of Transgenic Rice Event, CPPO06 in Direct-Seeding Flooded Rice Field (담수직파에서 형질전환 CPPO06이벤트 벼의 안전성 및 잡초방제효과)

  • Won, Ok Jae;Park, Su Hyuk;Eom, Min Yong;Kim, Chang-Gi;Lee, Bum Kyu;Kang, Hong-Gyu;Lee, Jeung Ju;Park, Kee Woong
    • Weed & Turfgrass Science
    • /
    • v.4 no.1
    • /
    • pp.44-48
    • /
    • 2015
  • This study was conducted to evaluate the efficacy of weed control and phytotoxicity of oxyfluorfen using a transgenic rice line (CPPO06 event) resistant to protoporphyrinogen oxidase (Protox) inhibiting herbicides in the direct-seeding flooded rice. Five annual weeds including Echinochloa oryzoides and two perennial weeds were occurred in the test field. Oxyfluorfen at 120 g a.i. $ha^{-1}$ in the application timing of two days before sowing and 0 and five days after sowing showed more than 90% weed control value except for Juglans mandshurica. Total weed control value was more than 95% in any application timing indicating a highly effective herbicide in the direct-seeding flooded rice. When compared with untreated control, no visual injuries were detected at single and double dosage of oxyfluorfen. The agronomic characteristics and yield components of CPPO06 event was reasonable in any time of application in this study. Based on these data, oxyfluorfen application before and after sowing can be applied to provide effective weed management in the direct-seeding flooded field.

Macroscopic High-Temperature Structural Analysis Model for a Small-Scale PCHE Prototype (I) (소형 PCHE 에 대한 거시적 고온 구조 해석 모델링 (I))

  • Song, Kee-Nam;Lee, Heong-Yeon;Kim, Chan-Soo;Hong, Sung-Duk;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1499-1506
    • /
    • 2011
  • The IHX (intermediate heat exchanger) is a key component of nuclear hydrogen systems for the production of massive amounts hydrogen. The IHX transfers the $950^{\circ}C$ heat generated by the VHTR (very high temperature reactor) to a hydrogen production plant. The Korea Atomic Energy Research Institute established a small-scale gas loop to test the performance of key VHTR components and manufactured a small-scale PCHE (printed circuit heat exchanger) prototype, which is being considered as a candidate for the IHX, for testing in the small-scale gas loop. In this study, as a part of the high-temperature structural integrity evaluation of the small-scale PCHE prototype, we carried out high-temperature structural analysis modeling and macroscopic thermal and structural analysis for the small-scale PCHE prototype under the small-scale gas loop test conditions. This analysis serves as a precedent study to scheduled PCHE performance test in the small-scale gas loop. The results obtained in this study will be compared with the test results for the small-scale PCHE and then used to design the medium-scale PCHE prototype.

Classification of Ultrasonic NDE Signals Using the Expectation Maximization (EM) and Least Mean Square (LMS) Algorithms (최대 추정 기법과 최소 평균 자승 알고리즘을 이용한 초음파 비파괴검사 신호 분류법)

  • Kim, Dae-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.27-35
    • /
    • 2005
  • Ultrasonic inspection methods are widely used for detecting flaws in materials. The signal analysis step plays a crucial part in the data interpretation process. A number of signal processing methods have been proposed to classify ultrasonic flaw signals. One of the more popular methods involves the extraction of an appropriate set of features followed by the use of a neural network for the classification of the signals in the feature spare. This paper describes an alternative approach which uses the least mean square (LMS) method and exportation maximization (EM) algorithm with the model based deconvolution which is employed for classifying nondestructive evaluation (NDE) signals from steam generator tubes in a nuclear power plant. The signals due to cracks and deposits are not significantly different. These signals must be discriminated to prevent from happening a huge disaster such as contamination of water or explosion. A model based deconvolution has been described to facilitate comparison of classification results. The method uses the space alternating generalized expectation maximiBation (SAGE) algorithm ill conjunction with the Newton-Raphson method which uses the Hessian parameter resulting in fast convergence to estimate the time of flight and the distance between the tube wall and the ultrasonic sensor. Results using these schemes for the classification of ultrasonic signals from cracks and deposits within steam generator tubes are presented and showed a reasonable performances.

Characteristics Testing of the ECT Bobbin Probe for Steam Generator Tube Inspection of Nuclear Power Plant (원전 증기발생기 전열관 와전류검사 보빈탐촉자의 특성 시험)

  • Nam, Min-Woo;Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.386-395
    • /
    • 2010
  • The steam generator management program(SGMP) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. The first way is to qualify the equipment or the probe by using the flaw mechanism and method of the pulled tubes from the heat exchangers or the artificial flawed tubes. The second way is to verify the equivalency with the characteristics of the qualified equipment or probe. In this case, the qualified equipment or probe may be modified to substitute or replace instruments or probes without re-qualification provided that the range of essential variables defined in the examination technique specification sheet are met. This study is to describe the result of the comparative performance evaluation of bobbin coil eddy current probes manufactured by KEPCO Research Institute and probes manufactured by a foreign manufacturer. As a result of this study, although there were minor differences between the two kinds of probes, it was evaluated that the two kinds of probes were almost identical in the significant performance characteristics described in the KEPCO Research Institute guideline.

A study on the evaluation of lower heating value using heat balance method in industrial waste incineration facilities (열정산방법을 이용한 사업장폐기물 소각시설의 저위발열량 분석·평가 연구)

  • Ko, Youngjae;Kang, Jun-Gu;Kwon, Young-Hyun;Yoo, Ha-Nyoung;Kwon, Jun-Hwa;Jang, Mi-Jeong;Jeon, Tae-Wan;Shin, Sun-Kyoung
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.31-38
    • /
    • 2018
  • The energy recovery rate estimation method proposed through the Waste Control Act does not take into account the energy used in practice. In addition, the method for measuring a lower heating value, which is the main factor of the energy recovery rate, was carried out through a small sampling amount, and thus the representative value of the waste was not reflected. With the revised estimation method (Notification No. 2015-215 of the Ministry of Environment), the energy recovery rate should be estimated based on the actual amount of energy used, and a heat balance method was proposed as a way to estimate the lower heating value. In this study, the lower heating value was estimated for seven industrial waste incineration facilities according to the revised estimation method. All data used in the estimations were achieved from measurement instruments applied to each of the incinerators and through direct measurements taken by the operators for the purposes of calculation. As a result, the lower heating value was estimated to be about 3,404.7 kcal/kg for the seven industrial waste incineration facilities.

Research on the Transfer Factor for $C^{14}$ Ingestion Dose Evaluation in PWR plant (PWR 발전소에서 $C^{14}$ 섭취선량 평가를 위한 전이계수 연구)

  • Kim Soong-Pyung;Han Young-Ok;Park Kyeong-Rok
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.476-484
    • /
    • 2005
  • This paper is to evaluate rather correctly $C^{14}$ ingestion dose that inhabitants around PWR plants can receive, and draw how to apply TF(Transfer Factor) to evaluate dose by the ingestion of animal products. For this, in this paper, dose assessment and analysis about existing materials related to TF were carried out, and the methodology to present TF was based on dose assessment and analysis result. The ingestion dose calculated using TFs presented by CSA and KEPRI was high or equal compared with SAM(Specific Activity Model) which is the most conservative, on the other hand, TFs given by NEC did not consider the effect according to volume change of animal at all, Therefore, it is judged that models used in the existing codes to asses the $C^{14}$ concentration into animal products must be improved to apply fundamentally hybrid model using transfer factors, that transfer factor on each animal products have to be developed through experiment for applying to our county.

  • PDF

Estimation of Oil Yield of Perilla by Seed Characteristics and Crude Fat Content

  • Oh, Eunyoung;Lee, Myoung Hee;Kim, Jung In;Kim, Sungup;Pae, Suk-Bok;Ha, Tae Joung
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.63 no.2
    • /
    • pp.158-163
    • /
    • 2018
  • Perilla (Perilla frutescens var.frutescens) is an annual plant of the Lamiaceae family, mainly grown for obtaining oil by press extraction after roasting the seeds. Oil yield is one of its important traits, but evaluating this yield is time-consuming, requires many seeds, and is hard to adjust to pedigrees in a breeding field. The objective of this study was to develop a method for selecting high-oil-yield lines in a breeding population without oil extraction. Twenty-three perilla cultivars were used for evaluating the oil yield and seed traits such as seed hardness, seed coat thickness, seed coat proportion and crude fat. After evaluation of the seed traits of 23 perilla cultivars, the ranges of oil yields, seed hardness, seed coat thickness, seed coat proportion, 100-seed weight, and crude fat were 24.68-38.75%, 157-1166 gf, $24-399{\mu}m$, 15.4-41.5%, 2.79-6.69 g, and 33.0-47.8%, respectively. In an analysis of correlation coefficients, the oil yield negatively correlated with seed length, seed width, the proportion of seed coat, seed hardness, and 1000-seed weight, but positively correlated with crude fat content. It was observed that as the seed coat proportion increased, the seed coat thickness, hardness, and 1000-seed weight also increased. Multiple linear regression (MLR) was employed to find major variables affecting the oil yield. Among the variables, traits crude fat content and seed coat proportion were assumed to be indirect parameters for estimating the potential oil yield, with respect to a significant positive correlation with the observed oil yield ($R^2=0.791$). Using these two parameters, an equation was derived to predict the oil yield. The results of this study show that various seed traits in 23 perilla cultivars positively or negatively correlated with the oil yield. In particular, crude fat and the seed coat proportion can be used for predicting the oil yield with the newly developed equation, and this approach will improve the efficiency of selecting prominent lines for the oil yield.

Evaluation of Phosphorus Release Potential in Arable land with Different Landuse by Phosphorus Threshold (변곡점을 이용한 영농형태별 토양 인산 유출 잠재력 평가)

  • Lee, Seul-Bi;Lee, Chang-Hoon;Hong, Chang-Oh;Lee, Yong-Bok;Kim, Pil-Joo
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.4
    • /
    • pp.343-347
    • /
    • 2010
  • Heavy application of fertilizer and manure in excess from the optimum requirement for crop growth can increase phosphorus (P) accumulation and P release potential in soils. In this study, the relationship between soil test P and 0.01M $CaCl_2$ extractable P was analysed to evaluate the P release potential of agricultural soils under different land-use. The paddy, upland, plastic film house(PFH) soils were sampled from Tongyoung and Changnyeong, and Daegok areas in Gyeongnam province, respectively. With respect to the P accumulation, available P contents in upland and PFH soils were 619 and 796 mg $P_2O_5$/kg, respectively indicating that different land-use types can greatly impact soil P accumulation. As soil available P was increased in the paddy soil, the content of 0.01M $CaCl_2$ extractable P also linearly increased without change point. Comparatively, P threshold were detected at 520 mg $P_2O_5$/kg in both upland and PFH soils, indicating that P release potential were higher in these land-use systems. For reducing P release from agricultural soils, management of optimum P content is needed in soils possessing high P release potential. Further, the change point value, if it is to be used as an environmental indicator, requires more detailed investigation to cover a wide range of soil characteristics.