• Title/Summary/Keyword: Plant Evaluation

Search Result 2,883, Processing Time 0.032 seconds

Evaluation of Shrinkage of Heavyweight Magnetite Concrete with Fly Ash (플라이 애쉬 치환율에 따른 중량 자철석 콘크리트의 건조수축 평가)

  • Mun, Jae-Sung;Yang, Keun-Hyeok;Lee, Hyun-Ho;Kim, Sang-Chel
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.2
    • /
    • pp.152-157
    • /
    • 2014
  • The objective of this study is to examine the drying shinkage and autogenuous shrinkage strains of heavyweight magnetite concrete. As a main parameters, cement was partially replaced by fly ash (FA) from 5% to 35%. The measured shrinkage strains were compared with predictions obtained from CEB-FIP equations and Yang et al.'s model. Test results showed that the magnitite of the autogenous and total shrinkage strains of heavyweight concrete slightly increased as the amount of fly ash increases up to 15%, beyond which the strains tended to decrease. The CEB-FIP equations considerably underestimated the shrinkage behavior of heavyweight concrete, indicating that this trend was more notable with the age. On the other hand, Yang et al.'s model predicted accurately the shrinkage of heavyweight concrete.

The Optimal Mixing Design of the PHC Piles Utilizing the Air Cooled Blast Furnace Slag as Coarse Aggregate (서냉 고로슬래그 굵은골재를 활용한 PHC 파일의 최적배합 및 물리적 특성)

  • Park, Yong-Kyu;Kim, Hyun-Woo;Kim, Seung-Il;Hur, Kab-Soo;Yoon, Ki-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.2
    • /
    • pp.137-144
    • /
    • 2014
  • The PHC pile utilizing the air-cooled blast-furnace slag as coarse aggregate was studied. This research was progressed with the range from the indoor mixing design evaluation into the actual goods production. The physical properties of the PHC pile are determined to satisfy through the appropriate mixing design adjustments. However, it should eliminate the aggregates including CaO and MgO in SG when it utilize in an AC (autoclave) type manufacturing process. It satisfied the bending moment, shear strength, and compressive strength of KS F 4306 except the surface states of the pile.

Evaluation of Sequential Extraction Techniques for Selected Heavy Metal Speciation in Contaminated Soils

  • Lee, Jin-Ho;Doolittle, James J.;Oh, Byung-Taek
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.236-246
    • /
    • 2006
  • In this study, we give insight into questionable results that can be encountered in the conventional sequential extraction of heavy metals (Cd, Cu, and Zn) from soils. Objectives of this study were to determine the extraction variability of exchangeable (EXC)-metals as using six different EXC-extractants commonly accepted, and to investigate selectivity problems with carbonates bound (CAB)-metal fraction, a buffered acetate (1.0 M NaOAc; pH 5.0) extractable-metal fraction, leading to erratic results in especially non-calcareous soils. The contents of EXC-metals were markedly varied with the different extractability of various EXC-metal extractants used. The contents of EXC-Cd fraction were ranged from 2.0 to 74.3% of total Cd content in all of the metal spiked soils studied. The contents of EXC-Zn fraction extracted with the different EXC-extractants were varied with soil types, which were from 0.4 to 3.9% of total Zn in the calcareous soils, from 7.6 to 17.9% in the acidic soil, and from 13.6 to 56.8% in the peat soil. However, the contents of EXC-Cu fraction were relatively similar among the applications of different EXC-meal extractants, 0.2 to 2.1 % of total Cu, in all soils tested. Also, these varied amounts of EXC-metal fractions, especially Cd and Zn, seriously impacted the contents of subsequent metal fractions in the procedure. Furthermore, the CAB-Cd, -Cu, and -Zn fractions extracted by the buffered acetate solution were in critical problem. That is, the buffered acetate solution dissolved not only CAB-metals but also metals that bound or occupied to subsequent fractions, especially OXD-metal fraction, in both calcareous and non-calcareous soils. The erratic results of CAB-fraction also seriously impacted the amounts of subsequent metal fractions. Therefore, the conventional sequential extraction should be reconsidered theoretically and experimentally to quantify the target metal fractions or might be progressively discarded.

Prevalence of pale, soft, and exudative (PSE) condition in chicken meat used for commercial meat processing and its effect on roasted chicken breast

  • Karunanayaka, Deshani S.;Jayasena, Dinesh D.;Jo, Cheorun
    • Journal of Animal Science and Technology
    • /
    • v.58 no.7
    • /
    • pp.27.1-27.8
    • /
    • 2016
  • Background: Studies on prevalence of pale, soft, exudative (PSE) condition in Sri Lankan poultry industry is minimal. Hence, the objective of present study was to determine the incidence of PSE chicken meat in a commercial meat processing plant and to find out its consequences on meat quality traits of roasted chicken breast. Method: A total of 60 breast fillets were randomly selected, evaluated based on color L* value, and placed into 1 of 2 categories; PSE (L* > 58) or normal meat ($L*{\leq}58$). A total of 20 breast fillets (10 PSE and 10 normal) were then analyzed for color, pH, and water holding capacity (WHC). After processing those into roasted chicken breast, cooking loss, color, pH, WHC, and texture values were evaluated. A sensory evaluation was conducted using 30 untrained panelists. Results: The incidence of PSE meat was 70 % in the present experiment. PSE fillets were significantly lighter and had lower pH values compared with normal fillets. Correlation between the lightness and pH was negative (P < 0.05). Although there was no significant difference in color, texture, and WHC values between the 2 groups after processing into roasted chicken breast (P > 0.05), an approximately 3 % higher cooking loss was observed in PSE group compared to its counterpart (P < 0.05). Moreover, cooking loss and lightness values showed a significant positive correlation. Nevertheless, there were no significant differences in sensory parameters between the 2 products (P > 0.05). Conclusions: These results indicated that an economical loss can be expected due to the significantly higher cooking loss observed in roasted breast processed from PSE meat.

Evaluation of Air-side Friction Characteristics on Design Conditions of Slit Fin and Tube Heat Exchanger (슬릿휜-관 열교환기의 설계조건에서 공기측 압력강하 산출)

  • Cho, Sung-Chul;Kim, Chang-Duk;Kim, Chang-Eob;Kwon, Jeong-Tae;Lim, Hyo-Jae
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.149-154
    • /
    • 2007
  • An experimental study on the air-side pressure drop of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side pressure drop in the literature is not based on a consistent approach. This paper focuses on method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface pressure drop estimation in fin-tube heat exchanger. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the air-side pressure drop on design conditions of condenser and evaporator. Results are pre-sented as plots of friction f-factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of $150{\sim}250\;kg/m^2s$ with air flows at velocity ranges from 0.38 m/s to 1.6 m/s.

Evaluation of Water Quality Prediction Models at Intake Station by Data Mining Techniques (데이터마이닝 기법을 적용한 취수원 수질예측모형 평가)

  • Kim, Ju-Hwan;Chae, Soo-Kwon;Kim, Byung-Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.5
    • /
    • pp.705-716
    • /
    • 2011
  • For the efficient discovery of knowledge and information from the observed systems, data mining techniques can be an useful tool for the prediction of water quality at intake station in rivers. Deterioration of water quality can be caused at intake station in dry season due to insufficient flow. This demands additional outflow from dam since some extent of deterioration can be attenuated by dam reservoir operation to control outflow considering predicted water quality. A seasonal occurrence of high ammonia nitrogen ($NH_3$-N) concentrations has hampered chemical treatment processes of a water plant in Geum river. Monthly flow allocation from upstream dam is important for downstream $NH_3$-N control. In this study, prediction models of water quality based on multiple regression (MR), artificial neural network and data mining methods were developed to understand water quality variation and to support dam operations through providing predicted $NH_3$-N concentrations at intake station. The models were calibrated with eight years of monthly data and verified with another two years of independent data. In those models, the $NH_3$-N concentration for next time step is dependent on dam outflow, river water quality such as alkalinity, temperature, and $NH_3$-N of previous time step. The model performances are compared and evaluated by error analysis and statistical characteristics like correlation and determination coefficients between the observed and the predicted water quality. It is expected that these data mining techniques can present more efficient data-driven tools in modelling stage and it is found that those models can be applied well to predict water quality in stream river systems.

Ecotoxicological Evaluation of Sewage Sludge Using Bioluminescent Marine Bacteria and Rotifer

  • Park, Gyung-Soo;Chung, Chang-Soo;Lee, Sang-Hee;Hong, Gi-Hoon;Kirn, Suk-Hyun;Park, Soung-Yun;Yoon, Seong-Jin;Lee!, Seung-Min
    • Ocean Science Journal
    • /
    • v.40 no.2
    • /
    • pp.91-100
    • /
    • 2005
  • Bioassay using the marine bacteria, Vibrio fischeri and rotifer, Brachionus plicatilis, and chemical analyses were conducted to assess the toxicity of the various sewage sludges, one of the major ocean dumped materials in the Yellow Sea of Korea. Sludge elutriates extracted by filtered seawater were used to estimate the ecotoxicity of the sludge. Chemical characterization included the analyses of organic contents, heavy metals, and persistent organic pollutants in sludge. Bacterial bioluminescent inhibition (15 min), rotifer mortality (24 hr) and rotifer population growth inhibition (48 hr) assay were conducted to estimate the sludge toxicity. EC50 15 min (inhibition concentration of bioluminescence after 15 minutes exposed) values by Microtox(R) bioassay clearly revealed different toxicity levels depending on the sludge sources. Highest toxicity for the bacteria was found with the sludge extract from dyeing waste and followed by industrial waste, livestock waste, and leather processing waste. Clear toxic effects on the bacteria were not found in the sludge extract from filtration bed sludge and rural sewage sludge. Consistent with Microtox(R) results, rotifer neonate mortality and population growth inhibition test also showed highest toxicity in dyeing waste and low in filtration bed and rural sewage sludge. High concentrations of persistent organic pollutants (POPs) and heavy metals were measured in the samples from the industrial wastes, leather processing plant waste sludge, and urban sewage sludge. However, there was no significant correlation between pollutant concentration levels and the toxicity values of the sludge. This suggests that the ecotoxicity in addition to the chemical analyses of various sludge samples must be estimated before release of potential harmful waste in the natural environment as part of an ecological risk assessment.

Immunological Assessment of Respiratory Allergy Status for the Swine Farm Workers in Gyeonggi Province of Korea (경기 일부지역 양돈 축산인들의 호흡기 알레르기 관련 면역학적 지표 분석)

  • Kim, Ji Youn;Kim, Kwang Ho;Hwang, So Ryeon;Yeo, Kyeong Uk;Kim, Hyoung Ah;Heo, Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.309-315
    • /
    • 2012
  • Objectives: Animal husbandry workers could be exposed to various work hazards including toxic gases, chemicals such as pesticides or organic dust. Immunological evaluation focusing on respiratory allergic hypersensitivity occurrence was under-taken for swine farm workers as a part of the study on immunologic status of dairy barn, swine confinement, and poultry farm workers. Materials and Methods: Peripheral bloods were collected from 25 workers at the year of 2001 and 12 workers at the year of 2012 from swine farms located at Gyeonggi province, Korea. Seven adults not involved with animal husbandry were recruited at the year of 2001 from the same residential area as the swine farm workers'. Level of plasma IgE and 20 respiratory allergen-specific IgE were evaluated using commercially available ELISA kit. Results: Plasma IgE level was approximately five-fold higher in the swine farm workers regardless of the sampling year than the control subjects. Plant allergens from outdoor environments such as golden rod, pigweed, Russian thistle, or ragweed were the major allergens with positive reaction(allergen specific IgE${\geq}$0.7 IU/mL) for the swine farm workers at 2001 year. Meanwhile, house dust mite(Dermatophagoides farinae, D. pteronyssinus) and cockroach, typical indoor allergens in Korea, were the major respiratory allergens for the swine farm workers at 2012 year. Conclusions: Overall, even though our results are primitive, the results suggest that immunological function of swine farm workers could be modulated toward type-2 reactivity.

Comparative Analysis between Direct-reading Meter of PID and GC-FID using the Active Type Air Sampler for VOCs Measurement (직독식 측정기 PID와 능동식 시료채취기에 의한 GC-FID 정량분석법의 VOCs 농도 비교 연구)

  • Yeo, Jin-Hee;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.301-306
    • /
    • 2016
  • Objectives: Direct-reading instrument(Photoionization detectors, PID) and quantitative analysis using active type air sampling (Gas chromatography-flame ionization detector, GC-FID) were tested to evaluate their ability to detect volatile organic compounds(VOCs) in a semiconductor manufacturing plant. Methods: The organic compounds used were acetone and ethanol which are normally used as cleaning solutions in the semiconductor manufacturing. The evaluation was based on the preparation of test solutions of known acetone and ethanol concentration in a chamber($600{\times}600{\times}1150mm$). Samples were prepared that would be equivalent to 5~100 ppm for acetone and 10~ 200 ppm ethanol. GC-FID and PID were evaluated simultaneously. Quantitative analysis was performed after sampling and the direct-reading instrument was checked using real-time data logging. Results: Positive correlations between PID and GC-FID were found for acetone and ethanol at 0.04~2.4% for acetone(TLV: 500 ppm) and 0.1~8.3% for ethanol(TLV: 1000 ppm). When the sampling time was 15 min, concentration of test solution was the most similar between measurement methods. However, the longer the sampling time, the less similar the results. PID and GC-FID had similar exposure patterns. Conclusions: The results indicate that PID and GC-FID have similar exposure pattern and positive correlation for detection of acetone and ethanol. Therefore, PID can be used for exposure monitoring for VOCs in the semiconductor manufacturing industry. This study has significance in that it validates measuring occupational exposure using a portable device.

Evaluation of Water Quality Goal and Load Allocation Achievement Ratio in Guem River Total Maximum Daily Loads for the 1st Phase (금강수계 1단계 수질오염총량관리제의 목표수질 및 할당부하량 달성도 평가)

  • Park, Jae Hong;Oh, Seung Young;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.859-865
    • /
    • 2012
  • It is necessary to evaluate performances hitherto carried out in the management of Total Maximum Daily Loads (TMDLs) and to set up direction so that this system can be improved continuously in the future. This study was investigated load allocation achievement ratio, water quality goal achievement ratio and interrelation between water quality goal and load allocation for the first period (2004~2010). Load allocation achievement and BOD water quality goal achievement ratio were 50% and 73% in Guem River Basin, respectively. The main reason for excess of load allocation and shortfall of water quality goal were unfulfilled reduction plan and pollution sources increment. Therefore, it is necessary to develop enhanced pollution sources prediction method and make a list realizable reduction plan. 63% of the unit watershed was not interrelation between water quality goal and load allocation. The reason why water quality goal and load allocation had not correlation were water quality of upper unit watershed, increment of inflow quantity, effluent water quality of wastewater treatment plant affected the unit watershed, increment of inner productivity by algae, water quality deterioration during the specific period, river management flow, etc.