• 제목/요약/키워드: Planning target volume

검색결과 284건 처리시간 0.022초

Neck Node Bolus Technique in the Treatment of Nasopharyngeal Carcinoma with Intensity-modulated Radiotherapy

  • Phua, Chee Ee;Ung, Ngie Min;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권12호
    • /
    • pp.6133-6137
    • /
    • 2012
  • Purpose: To study the effect of bolus versus no bolus in the coverage of the nodal tumour volume with intensity-modulated radiotherapy (IMRT) for the treatment of nasopharyngeal carcinoma (NPC). Methods and Materials: This retrospective study used data from 5 consecutive patients with NPC who were treated with bolus for large neck nodes using IMRT from November 2011-January 2012 in our institute. All these patients were treated radically with IMRT according to our institution's protocol. Re-planning with IMRT without bolus for these patients with exactly the same target volumes were done for comparison. Comparison of the plans was done by comparing the V70 of PTV70-N, V66.5 of PTV70-N, V65.1 of PTV70-N and the surface dose of the PTV70-N. Results: The mean size of the largest diameter of the enlarged lymph nodes for the 5 patients was 3.9 cm. The mean distance of the GTV-N to the skin surface was 0.6 cm. The mean V70 of PTV70-N for the 5 patients showed an absolute advantage of 10.8% (92.4% vs. 81.6%) for the plan with bolus while the V66.5 of PTV70-N had an advantage of 8.1% (97.0% vs. 88.9%). The mean V65.1 also had an advantage of 7.1% (97.6% vs. 90.5%). The mean surface dose for the PTV70-N was also much higher at 61.1 Gy for the plans with bolus compared to only 23.5 Gy for the plans without bolus. Conclusion: Neck node bolus technique should be strongly considered in the treatment of NPC with enlarged lymph nodes treated with IMRT. It yields a superior dosimetry compared t o non-bolus plans with acceptable skin toxicity.

도심 임대아파트의 에너지 및 상수 소비 특성에 관한 연구 (An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment)

  • 서윤규;김주영;홍원화
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.39-46
    • /
    • 2009
  • It has been a serious problem to consume the energy of apartment while increasing to use of heating & cooling System because of residence environmental upgrades. Great attention has been shown to the problem of the rental apartment, so there are few reports of energy consumption about the rental apartment in korea. To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072\;m^2$ per year and typical energy consumption unit was $604.2\;MJ/m^2$ on $74.4\;m^2$ of area and $448.8\;MJ/m^2$ on $105.8\;M^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an typical energy consumption unit standard through this research, apartments should use energy more efficiently.

Dosimetric Evaluation of Plans Converted with the DVH-Based Plan Converter

  • Chun, Minsoo;Choi, Chang Heon;Kim, Jung-in;Yoo, Jeongmin;Lee, Sung Young;Kwon, Ohyun;Son, Jaeman;An, Hyun Joon;Kang, Seong-Hee;Park, Jong Min
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.157-163
    • /
    • 2018
  • Plans converted using dose-volume-histogram-based plan conversion (DPC) were evaluated by comparing them to the original plans. Changes in the dose volumetric (DV) parameters of five volumetric modulated arc therapy (VMAT) plans for head and neck (HN) cancer and five VMAT plans for prostate cancer were analyzed. For the HN plans, the homogeneity indices (HIs) of the three planning target volumes (PTV) increased by 0.03, 0.02, and 0.03, respectively, after DPC. The maximum doses to the PTVs increased by 1.20, 1.87, and 0.92 Gy, respectively, after DPC. The maximum doses to the optic chiasm, optic nerves, spinal cord, brain stem, lenses, and parotid glands increased after DPC by approximately 4.39, 3.62, 7.55, 7.96, 1.77, and 6.40 Gy, respectively. For the prostate plans after DPC, the HIs for the primary and boost PTVs increased by 0.05 and 0.03, respectively, and the maximum doses to each PTV increased by 1.84 and 0.19 Gy, respectively. After DPC, the mean doses to the rectum and femoral heads increased by approximately 6.19 and 2.79 Gy, respectively, and those to the bladder decreased by 0.20 Gy when summing the primary and boost plans. Because clinically unacceptable changes were sometimes observed after DPC, plans converted by DPC should be carefully reviewed before actual patient treatment.

Dosimetric Comparison of Noncoplanar and Coplanar Volumetric Modulated Arc Therapy Plans for Esophageal Cancer

  • Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.179-188
    • /
    • 2020
  • Purpose: We compared noncoplanar volumetric modulated arc therapy (ncVMAT) plans to coplanar VMAT (cVMAT) plans by evaluating the dosimetric quality of each for esophageal cancer. Methods: Twenty patients treated for esophageal cancer with the cVMAT technique were retrospectively selected. The cVMAT plans consisted of three coplanar full arc beams. The ncVMAT plans consisted of two coplanar full arc beams and one noncoplanar partial arc beam ranging from 45° to 315° with a couch rotation angle of 315°±5°. For dosimetric evaluation, the dose-volumetric (DV) parameters of the planning target volume (PTV) and organs at risk (OARs) were calculated for all VMAT plans. Results: No clinically noticeable differences between the cVMAT and ncVMAT plans were observed in the DV parameters of the PTV. For the lungs, the V13 Gy and mean dose for ncVMAT plans were smaller than those for cVMAT plans, showing statistically significant differences. For the heart, the values of the maximum dose for cVMAT and ncVMAT plans were 53.8±2.9 and 50.9±3.3 Gy, respectively (P=0.004). For the spinal cord, the values of the maximum dose for cVMAT and ncVMAT plans were 37.1±5.1 and 34.7±5.7 Gy, respectively (P<0.001). Conclusions: The use of ncVMAT plans provides better PTV coverage and sparing of OARs compared to that of cVMAT plans for long, tube-like esophageal cancer. For esophageal cancer, the ncVMAT plans showed a more favorable plan quality than the cVMAT plans.

토모테라피에서 쌀 볼루스 팬텀의 유용성 평가: 팬텀연구 (Evaluating the Usefulness of Rice Bolus Phantom in Tomotherapy: Phantom Study)

  • 김대건;정재홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.663-669
    • /
    • 2021
  • The purpose of this study was to evaluate the usefulness of the rice bolus for upper-lower extremity radiation therapy by Tomotherapy. The computed tomography images were obtained for air, water, and rice bolus. The average and standard deviation of the Hounsfield unit (HU) were measured for image evaluation. The conformity index (CI) and homogeneity index (HI) were calculated for dose distribution of the planning target volume (PTV) which was treated by direct mode with gantry angle (90 and 270 angle). The point dose of a total of ten axial planes was measured to confirm the different regions. The mean of HU was -999.72 ± 0.72 at the air. The water and rice bolus were -0.13 ± 1.65 and -170 ± 27.2, respectively. The CI (HI) of PTV was 0.96 (1.36) at the air. 0.95 (1.04) at the water bolus, and 0.95 (1.04) at the rice bolus. The maximum dose for air was 136 cGy which is about 32% higher than 103 cGy for water and 104 cGy for rice bolus. There was a statistical difference for point dose between air and water including rice bolus (p=0.04), however, no statistical difference between water and rice bolus (p=0.579).The rice bolus phantom for extremities radiation therapy could be not only the optimized dose distribution but also the convenience and equipment safety at Tomotherapy. However, additional research will be necessary to more accurately verify the clinical usefulness of rice bolus phantom due to not enough examination.

Development and Evaluation of the Utility of a Respiratory Monitoring and Visual Feedback System for Radiotherapy Using Machine Vision Technology

  • Kim, Chul Hang;Choi, Hoon Sik;Kang, Ki Mun;Jeong, Bae Kwon;Jeong, Hojin;Ha, In Bong;Song, Jin Ho
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.8-15
    • /
    • 2022
  • Background: We developed a machine vision technology program that tracks patients' real-time breathing and automatically analyzes their breathing patterns. Materials and Methods: To evaluate its potential for clinical application, the image tracking performance and accuracy of the program were analyzed using a respiratory motion phantom. Changes in the stability and regularity of breathing were observed in healthy adult volunteers according to whether the breathing pattern mirrored the breathing guidance. Results and Discussion: Displacement within a few millimeters was observed in real-time with a clear resolution, and the image tracking ability was excellent. This result was consistent even in the sections where breathing patterns changed rapidly. In addition, the respiratory gating method that reflected the individual breathing patterns improved breathing stability and regularity in all volunteers. Conclusion: The findings of this study suggest that this technology can be used to set the appropriate window and the range of internal target volume by reflecting the patient's breathing pattern during radiotherapy planning. However, further studies in clinical populations are required to validate this technology.

Assessment of Abdominal Organs Movement by Respiration Using Computed Tomography in Dogs: A Pitfall for Radiation Therapy

  • Ah Reum Kim;Soyon An;Gunha Hwang;Moonyeong Choi;Tae Sung Hwang;Hee Chun Lee
    • 한국임상수의학회지
    • /
    • 제40권2호
    • /
    • pp.104-112
    • /
    • 2023
  • The change in the position of the abdominal organs due to movement by respiration is one of the reasons behind inaccurate irradiation of organs during radiotherapy (RT). Although studies in human medicine have revealed on the respiratory movements of abdominal organs, there is little information and no reference data for dogs. The purpose of this study was to establish the reference values of abdominal organs movement in various postures using computed tomography (CT), and to compare the movements of organs between dorsal recumbency and ventral, right and left lateral recumbency during respiration. CT images for kidney, adrenal gland, medial iliac lymph node, urinary bladder, gallbladder, liver, stomach, and thoracic and lumbar vertebral body of five beagle dogs were acquired. The movements of organs were evaluated by comparing the end-expiratory and end-inspiratory images. Movements of the organs were evaluated by dividing it into right-to-left, dorsal-to-ventral, and cranial-to-caudal directions. The movements of abdominal organs according to the change in postures and respiration were establish. The movement of the bilateral organs was the least when the organs were in the downward position (p < 0.017). The movement of cranial-to-caudal direction was greater than the movement of the other directions in most of the organs. Data obtained in this study may be useful in selecting the appropriate posture that can reduce the movements of organs to be treated with RT, and the data could be useful for setting the planning target volume to consider the movements of the abdominal organs by respiration.

국소적으로 진행된, 절제 불가능한 췌장암에서 정위 방사선 치료 (Locally Advanced, Unresectable Pancreatic Cancer Treated by Stereotactic Radiation Therapy)

  • 최철원;김미숙;조철구;류성렬;양광모;유형준;이동한;지영훈;한철주;김진;김영한
    • Radiation Oncology Journal
    • /
    • 제24권1호
    • /
    • pp.11-20
    • /
    • 2006
  • 목적: 국소적으로 진행된, 절제 불가능한 췌장암 치료에 있어 고식적 방사선 치료와 비교하여 Cyberknife(CK)를 이용한 정위 방사선 치료의 생존율 및 급성 독성에 대해 분석하고자 하였다. 대상 및 방법: 2003년 4월부터 2004년 4월까지의, Eastern Cooperative Oncology Group (ECOG) 활동도 3 이하이며 CT 및 PET/CT로 평가하여 원격 전이 없는 국소 진행된 췌장암 환자 19명을 대상으로 하였다 대상 환자는 점차 방사선량을 증가시키는 방법으로 33 Gy, 36 Gy, 39 Gy를 3분할로 각각 6명, 4명, 9명에서 CK를 이용한 정위 방사선 치료를 시행하였으며, 생존율 및 Radiation Therapeutic Oncology Group (RTOG) acute radiation morbidity criteria에 의한 위장관 독성을 분석하였다 또한 나이, 성별, ECOG 수행 점수, 항암 치료, 우회로 조성술(bypass surgery) 여부, 방사선량, CAl9-9, 계획용 표적 체적(planning target volume, PTV), CT상 주위 장기 및 혈관 침범 여부 등을 Log Rank test를 이용하여 예후 인자를 평가하였다. 결과: 본 연구에서 중앙 생존 기간은 11개월, 1년 생존율은 36.8%였다. 추적 조사 기간 중(범위 $3{\sim}20$개월, 중앙값 10개월) 유의한 위장관 급성 독성은 관찰되지 않았다 단일 인자 분석에서 계획용 표적 체적만이 유의한 예후 인자로 80cc 이하인 경우가 80cc 이상인 경우보다 생존율이 높았으며(p-value < 0.05), 나이, 성별, ECOG 수행 점수, 항암 치료, 우회로 조성술, CAl9-9 수치, 주위 장기 및 혈관 침범 여부 등에서는 통계적으로 유의한 차이를 보이지 않았다. 다인자 분석에서는 65세 이하인 경우와 PTV 80 co 이하인 경우에서 생존율이 높았다. 결론: 고식적 방사선 치료, 고선량 입체조형 방사선 치료(high dose conformal radiation therapy), 수술 중 방사선 치료(intraoperative radiation therapy) 또는 세기 조절 방사선 치료(Intensity modulated radiation therapy, IMRT)를 이용한 최근의 결과와 비교하여 CK를 이용한 정위 방사선 치료는 생존율 측면에서 비슷하거나 나은 결과를 보였다. 또한 심각한 부작용은 관찰되지 않았으며 짧은 기간의 치료로 환자에게 편의를 제공할 수 있어 결과적으로 삶의 질을 향상시킬 수 있을 것이다. 따라서, 이 새로운 치료 방법은 국소 진행된, 절제 불가능한 췌장암 환자에서 심각한 부작용 없는 효과적인 치료가 될 것으로 생각된다. 또한 계획용 표적 체적은 CK 치료의 유용한 예후 인자로 사용될 것이다.

원발성 간암의 분할 정위방사선치료 효과 (Effects of Fractionated Stereotactic Radiotherapy for Primary Hepatocellular Carcinoma)

  • 최병옥;강기문;장홍석;이상욱;강영남;채규영;최일봉
    • Radiation Oncology Journal
    • /
    • 제23권2호
    • /
    • pp.92-97
    • /
    • 2005
  • 목적 : 원발성 간암에서 근치적 목적의 방사선치료 결과엔 대한 문헌상 보고는 드물다. 이에 저자들이 경험한 원발성 간암의 분할 정위방사선치료에 대한 결과를 보고하고자 하였다. 대상 및 방법 : 1999년 7월부터 2002년 3월까지 원발성 간암으로 조직학적 진단을 받은 후 분할 정위방사선치료를 시행한 20명을 대상으로 후향적 분석을 하였다. 종양의 장경은 $2~6.5\;cm$ (평균: 3.8 cm)였다. 분할 정위방사선치료는 1회 조사량으로 5와 10 Gy였고 선량은 계획용 표적체적(planning target volume)에 맞추어 처방하였으며 회전중심점 선량의 $85\~90\%$등선량 곡선에 치료를 하였다. 주 $3\~5$회 치료하여 2주 동안 총 50 Gy를 조사하였다(중앙선량: 50 Gy). 추적관찰기간은 $3\~55$개월(중간 추적관찰기간: 23개월)이었다. 결과 : 전체 치료 반응률은 $60\%$이었으며 완전 반응 4명($20\%$), 부분 반응 8명($40\%$), 안정성 병변이 8명($40\%$)이었다. 전체 환자의 1년 및 2년 생존율은 각각 $70\%$, $43.1\%$이었으며 중앙 생존기간은 20개월이었다. 1년 및 2년 무병 생존율은 각각 $65\%$, $32.5\%$이었으며 중앙 무병생존기간은 19개월이었다. 치료 부작용으로 소화장애가 16명($60\%$), 오심/구토가 8명($40\%$), 간 기능 저하가 6명($30\%$)에서 발생하였으나 부작용에 의한 사망은 없었다. 결론 : 원발성 간암의 분할 정위방사선치료는 비교적 안전하고 효과적인 방법이었다. 따라서 단일 병변이면서 비교적 종양의 크기가 작은 간암에서 내과적으로 수술이 불가능하거나 수술을 거부하는 환자에서 국소 치료방법으로 고려할 수 있을 것으로 사료된다.

Jaw tracking을 이용한 다발성 뇌 전이의 용적세기조절회전치료에 대한 유용성 평가 (Evaluation of the Usefulness for VMAT of multiple brain metastasis using jaw tracking)

  • 김태원;유순미;전수동;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.73-81
    • /
    • 2018
  • 목 적 : 다발성 뇌 전이의 방사선치료 시 jaw tracking(JT)과 fixed jawFJ)를 이용한 용적세기조절회전치료(Volumetric Modulated Arc Therapy, VMAT)를 비교하고 유용성을 평가하고자 한다. 대상 및 방법 : JT를 이용하여 치료받은 다발성 뇌 전이(Multiple Brain Metastasis) 환자 중 6개 이상의 종양이 있고 조사면 크기가 $14{\times}14cm^2$ 이상인 환자 10명을 대상으로 하였다. Eclipse(Ver 13.6 Varian, USA)로 JT와 FJ의 전산화치료계획을 각각 수립하였으며, 전자포털영상장치(Electronic Portal Imaging Device, EPID)를 이용하여 감마지수(Gamma Index, 3 mm, 3 %, 95 % 신뢰구간) 및 최대선량차이(Max. Dose Difference)를 측정하였다. 또한 손상위험장기(Organ At Risk, OAR)의 $D_{max}$$D_{mean}$을 산출하고 비교하였으며 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity Index, HI)를 평가하였다. 결 과 : JT와 FJ의 측정값을 평가한 감마지수는 모든 Case에서 허용 기준(3 mm, 3 %, 95 % 신뢰구간)에 충족하였으며, 최대선량차이값은 Leaf End Transmission이 발생하는 영역에서 시계방향(Clockwise, CW)은 최대 98.4 %, 평균 43.6 %, 반시계방향(Counter-Clockwise, CCW)은 최대 67.9 %, 평균 41.0 %로 측정되었다. 손상위험장기는 JT를 사용하였을 때 각 정상장기에 대한 $D_{max}$의 최대값은 15.36 %~74.59 %, 평균값은 2.84 %~39.80 % 감소, $D_{mean}$의 최대값은 27.90 %~65.23 %, 평균값은 7.70 %~41.71 %로 감소하였으며, 처방선량지수와 선량균질지수값은 차이가 없었다. 결 론 : 다발성 뇌 전이에서 VMAT으로 치료할 경우 JT를 이용하면 치료계획용적(Planning Target Volume, PTV)의 선량분포에 영향을 미치지 않으면서 불특정 영역에서 발생하는 방사선의 누설 및 투과로 인한 불필요한 피폭을 감소시키고 정상장기에 더 낮은 선량으로 방사선치료가 가능할 것으로 사료된다.

  • PDF