• Title/Summary/Keyword: Plane of motion

Search Result 790, Processing Time 0.028 seconds

Gesture Interface for Controlling Intelligent Humanoid Robot (지능형 로봇 제어를 위한 제스처 인터페이스)

  • Bae Ki Tae;Kim Man Jin;Lee Chil Woo;Oh Jae Yong
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.10
    • /
    • pp.1337-1346
    • /
    • 2005
  • In this paper, we describe an algorithm which can automatically recognize human gesture for Human-Robot interaction. In early works, many systems for recognizing human gestures work under many restricted conditions. To eliminate these restrictions, we have proposed the method that can represent 3D and 2D gesture information simultaneously, APM. This method is less sensitive to noise or appearance characteristic. First, the feature vectors are extracted using APM. The next step is constructing a gesture space by analyzing the statistical information of training images with PCA. And then, input images are compared to the model and individually symbolized to one portion of the model space. In the last step, the symbolized images are recognized with HMM as one of model gestures. The experimental results indicate that the proposed algorithm is efficient on gesture recognition, and it is very convenient to apply to humanoid robot or intelligent interface systems.

  • PDF

Realistic Contents and Interaction Based Realistic Contents Service (상호작용 기반의 홀로그램 실감 콘텐츠 서비스연구)

  • Lee, Wan Jung;Shin, Eun Ji;Yoon, Hyun Sun;Choi, Hee Min;Cho, Dong Sik;Kang, Hoon Jong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.10 no.10
    • /
    • pp.429-438
    • /
    • 2021
  • In recent, realistic content has been applied in various ways due to the development of display technology and hologram, the final realistic content technology, have been used limitedly in accordance with the growing public demand. However, most realistic content requires additional devices of HMD (head mounted device) or glasses type, and other realistic content display technologies deliver a single image plane in the experience space to the user, providing a monotonous content experience. Various realistic contents with hologram technology are introduced in this work. In addition, we propose an interaction based realistic hologram service based that combines projection mapping and floating holograms. Projection-mapped screens and multi-floating hologram device provide a three-dimensional volumetric space with extended depth orientation from the user's point of view, while allowing users' entire and partial motions to be recognizable through multiple sensors.

The intrinsic instabilities of fluid flow occured in the melt of Czochralski crystal growth system

  • Yi, Kyung-Woo;Koichi Kakimoto;Minoru Eguchi;Taketoshi Hibiya
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.179-200
    • /
    • 1996
  • The intrinsic instabilities of fluid flow occurred in the melt of the Czochralski crystal growth system Czochralski method, asymmetric flow patterns and temperature profiles in the melt have been studied by many researchers. The idea that the non-symmetric structure of the growing equipment is responsible for the asymmetric profiles is usually accepted at the first time. However further researches revealed that some intrinsic instabilities not related to the non-symmetric equipment structure in the melt could also appear. Ristorcelli had pointed out that there are many possible causes of instabilities in the melt. The instabilities appears because of the coupling effects of fluid flow and temperature profiles in the melt. Among the instabilities, the B nard type instabilities with no or low crucible rotation rates are analyzed by the visualizing experiments using X-ray radiography and the 3-D numerical simulation in this study. The velocity profiles in the Silicon melt at different crucible rotation rates were measured using X-ray radiography method using tungsten tracers in the melt. The results showed that there exits two types of fluid flow mode. One is axisymmetric flow, the other is asymmetric flow. In the axisymmetric flow, the trajectory of the tracers show torus pattern. However, more exact measurement of the axisymmetrc case shows that this flow field has small non-axisymmetric components of the velocity. When fluid flow is asymmetric, the tracers show random motion from the fixed view point. On the other hand, when the observer rotates to the same velocity of the crucible, the trajectory of the tracer show a rotating motion, the center of the motion is not same the center of the melt. The temperature of a point in the melt were measured using thermocouples with different rotating rates. Measured temperatures oscillated. Such kind of oscillations are also measured by the other researchers. The behavior of temperature oscillations were quite different between at low rotations and at high rotations. Above experimental results means that the fluid flow and temperature profiles in the melt is not symmetric, and then the mode of the asymmetric is changed when rotation rates are changed. To compare with these experimental results, the fluid flow and temperature profiles at no rotation and 8 rpm of crucible rotation rates on the same size of crucible is calculated using a 3-dimensional numerical simulation. A finite different method is adopted for this simulation. 50×30×30 grids are used. The numerical simulation also showed that the velocity and flow profiles are changed when rotation rates change. Futhermore, the flow patterns and temperature profiles of both cases are not axisymmetric even though axisymmetric boundary conditions are used. Several cells appear at no rotation. The cells are formed by the unstable vertical temperature profiles (upper region is colder than lower part) beneath the free surface of the melt. When the temperature profile is combined with density difference (Rayleigh-B nard instability) or surface tension difference (Marangoni-B nard instability) on temperature, cell structures are naturally formed. Both sources of instabilities are coupled to the cell structures in the melt of the Czochralski process. With high rotation rates, the shape of the fluid field is changed to another type of asymmetric profile. Because of the velocity profile, isothermal lines on the plane vertical to the centerline change to elliptic. When the velocity profiles are plotted at the rotating view point, two vortices appear at the both sides of centerline. These vortices seem to be the main reason of the tracer behavior shown in the asymmetric velocity experiment. This profile is quite similar to the profiles created by the baroclinic instability on the rotating annulus. The temperature profiles obtained from the numerical calculations and Fourier transforms of it are quite similar to the results of the experiment. bove esults intend that at least two types of intrinsic instabilities can occur in the melt of Czochralski growing systems. Because the instabilities cause temperature fluctuations in the melt and near the crystal-melt interface, some defects may be generated by them. When the crucible size becomes large, the intensity of the instabilities should increase. Therefore, to produce large single crystals with good quality, the behavior of the intrinsic instabilities in the melt as well as the effects of the instabilities on the defects in the ingot should be studied. As one of the cause of the defects in the large diameter Silicon single crystal grown by the

  • PDF

Current Treatment of Tibial Pilon Fractures (경골 천정(pilon) 골절의 최신 치료)

  • Lee, Jun-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.51-57
    • /
    • 2011
  • Pilon fractures involving distal tibia remain one of the most difficult therapeutic challenges that confront the orthopedic surgeons because of associated soft tissue injury is common. To introduce and describe the diagnosis, current treatment, results and complications of the pilon fractures. In initial assessment, the correct evaluation of the fracture type through radiographic checkup and examination of the soft tissue envelope is needed to decide appropriate treatment planning of pilon fractures. Even though Ruedi and Allgower reported 74% good and excellent results with primary open reduction and internal fixation, recently the second staged treatment of pilon fractures is preferred to orthopedic traumatologist because of the soft tissue problem is common after primary open reduction and internal fixation. The components of the first stage are focused primarily on stabilization of the soft tissue envelope. If fibula is fractured, fibular open reduction and internal fixation is integral part of initial management for reducing the majority of tibial deformities. Ankle-spanning temporary external fixator is used to restore limb alignment and displaced intraarticular fragments through ligamentotaxis and distraction. And the second stage, definitive open reduction and internal fixation of the tibial component, is undertaken when the soft tissue injury has resolved and no infection sign is seen on pin site of external fixator. The goals of definitive internal fixation should include absolute stability and interfragmentary compression of reduced articular segments, stable fixation of the articular segment to the tibial diaphysis, and restoration of coronal, transverse, and sagittal plane alignments. The location, rigidity, and kinds of the implants are based on each individual fractures. The conventional plate fixation has more advantages in anatomical reduction of intraarticular fractures than locking compression plate. But it has more complications as infection, delayed union and nonunion. The locking compression plate fixation provides greater stability and lesser wound problem than conventional implants. But the locking compression plate remains poorly defined for intraarticular fractures of the distal tibia. Active, active assisted, passive range of motion of the ankle is recommended when postoperative rehabilitation is started. Splinting with the foot in neutral is continued until suture is removed at the 2~3 weeks and weight bearing is delayed for approximately 12 weeks. The recognition of the soft tissue injury has evolved as a critical component of the management of pilon fractures. At this point, the second staged treatment of pilon fractures is good treatment option because of it is designed to promote recovery of the soft tissue envelope in first stage operation and get a good result in definitive reduction and stabilization of the articular surface and axial alignment in second stage operation.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE BONE ANCHORED FIXED PROSTHESIS ACCORDING TO THE LOAD CONDITION (골유착 고정성 보철물 하에서 하중조건에 따른 삼차원 유한요소법적 분석)

  • Yang, Soon-Ik;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.780-806
    • /
    • 1995
  • The purpose of this study was to describe the application of 3D finite element analysis to determine resultant stresses on the bone anchored fixed prosthesis, implants and supporting bone of the mandible according to fixture numbers and load conditions. 4 or 6 fixtures and the bone anchored fixed prosthesis were placed in 3D finite element mandibular arch model which represents an actual mandibular skull. A $45^{\circ}$ diagonal load of 10㎏ was labiolingually applied in the center of the prosthesis(P1). A $45^{\circ}$ diagonal load of 20㎏ was buccolingually applied at the location of the 10mm or 20mm cantilever posterior to the most distal implant(P2 or P3). The vertical distribution loads were applied to the superior surfaces of both the right and the left 20mm cantilevers(P4). In order that the boundary conditions of the structure were located to the mandibular ramus and angle, the distal bone plane was to totally fixed to prevent rigid body motion of the entire model. 3D finite element analysis was perfomed for stress distribution and deflection on implants and supporting bone using commercial software(ABAQUS program. for Sun-SPARC Workstation. The results were as follows : 1. In all conditions of load, the hightest tensile stresses were observed at the metal lates of prostheses. 2. The higher tensile stresses were observed at the diagonal loads rather than the vertical loads 3. 6-implants cases were more stable than 4-implants cases for decreasing bending and torque under diagonal load on the anterior of prosthesis. 4. From a biomechanical perspective, high stress developed at the metal plate of cantilever-to-the most distal implant junctions as a consequence of loads applied to the cantilever extension. 5. Under diagonal load on cantilever extension, the 6-implants cases had a tendency to reduce displacement and to increase the reaction force of supporting point due to increasing the bendign stiffness of the prosthesis than 4-implants cases. 6. Under diagonal load on cantilever extension, the case of 10mm long cantilever was more stable than that of 20mm long cnatilever in respect of stress distribution and displacement. 7. When the ends of 10mm or 20mm long cantilever were loaded, the higher tensile stress was observed at the second most distal implant rather than the first most distal implant. 8. The 6-implants cases were more favorable about prevention of screw loosening under repeated loadings because 6-implants cases had smaller deformation and 4-implants cases had larger deformation.

  • PDF

Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT' (고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가)

  • Kim, Jaeil;Lim, Jeongjin;Cho, Seongwook;Noh, Kyeongwoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.54-58
    • /
    • 2019
  • Purpose At now, there are many kind of dedicated heart SPECT machine in clinical nuclear medicine. Among those, the fixed focusing type SPECT can make a good quality, quantity image because a detectors of this SPECT arranged forward a special ROI and didn't rotate around of body. So, in this paper, we will evaluate a spatial uniformity about resolution and sensitivity at a same plane of a fixed focusing type SPECT. Materials and Methods We used D-SPECT as a fixed focusing type SPECT and Cario MD as a rotated parallel type SPECT to comparing each other. We injected $^{99m}Tc(14.8MBq/1cc)$ to 10 capillary tube (diameter=1mm), and we set those line sources a tfield of view of each SPECT. And then we acquired SPECT date, we applied are construction by recommended methods. By using two tomography images, we calculated a full width of half maximum as a resolution and total counts as a sensitivity, and we compared a CV (coefficientofvariation) values between two images as a spatial uniformity. Results In case of D-SPECT, a CV of resolution and sensitivity are 7.45%, 12.34%. In case of Cario MD, an CV of resolution and sensitivity are 12.49%, 21.84% Conclusion As a results, CV of resolution and sensitivity of a fixed focusing type SPECT is 67.75%, 77.00% higher than ones of a rotated parallel type SPECT. It means that a fixed focusing type SPECT is more uniformed, because this new SPECT can reduce a motion blur artifact by rotating detector around body, also all of detector that made by semiconductor arrange forward a special FOV like heart.

Finite Element Modeling and Nonlinear Analysis of Lumbosacrum Including Partial Ilium and Iliolumbar Ligaments (부분 장골과 장요추 인대를 포함한 요추 천추골의 유한 요소 모델링 및 비선형 해석)

  • Ha, S.K.;Lim, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.397-409
    • /
    • 2007
  • Owing to needs of biomechanical comprehension and analysis to obtain various medical treatment designs which are related with the spine in order to cure and diagnose LBP patients, the FE modeling and nonlinear analysis of lumbosacrum including a partial ilium and iliolumbar ligaments, were carried out. First, we investigated whether the geometrical configuration of vertebrae displayed by DICOM slice files is regular and normal condition. After constructing spinal vertebrae including a partial ilium, a sacrum and five lumbars (from L1 to L5)with anatomical shape reconstructed using softwares such as image modeler and CAD modeler, we added iliolumbar ligaments, lumbar ligaments, discs and facet joints, etc.. And also, we assigned material property and discretized the model using proper finite element types, thus it was completely modeled through the above procedure. For the verification of each segment, average sagittal ROM, average coronal ROM and average transversal ROM under various loading conditions(${\pm}10Nm$), average vertical displacement under compression(400N), ALL(Anterior Longitudinal Ligament) and PLL(Posterior Longitudinal Ligament) force at L12 level, strains of seven ligaments on sagittal plane at L45 level and maximal strain of disc fibers according to various loading conditions at L45 level, etc., they were compared with experimental results. For the verification of multilevel-lumbosacrum spine including partial ilium and iliolumbar ligaments, the cases with and without iliolumbar ligaments were compared with ROM of experiment. The results were obtained from analysis of the verified FE model as follows: I) Iliolumbar ligaments played a stabilizing role as mainly posterior iliolumbar ligaments under flexion and as both posterior and anterior iliolumbar ligaments of one side under lateral bending. 2) The iliolumbar ligaments decreased total ROM of 1-8% in total model according to various motion conditions, which changed facet contact forces of L5S level by approximately 0.8-1.4 times and disc forces of L5S level by approximately 0.8-1.5 times more than casewithout ilioligaments, under various loading conditions. 3) The force of lower discs such as L45 and L5S was bigger than upper discs under flexion, left and right bending and left and right twisting, except extension. 4) It was predicted that strains of posterior ligaments among iliolumbar ligaments would produce the maximum 16% under flexion and the maximum 10% under twisting. 5) It's expected that this present model applies to the development and design of artificial disc, since it was comparatively in agreement with the experimental datum.

Changes of Head Posture in Standing and Sitting Posture (서 있는 자세와 앉은 자세에서 두부자세의 변화)

  • Sang-Chan Lee;Kyung-Soo Han;Myung-Seok Seo
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.305-315
    • /
    • 1996
  • This study was performed to investigate the changes of head posture according to natural standing or sitting posture. Twenty seven healthy dental students without any signs and symptoms of temporomandibular disorders participated in this study. Cervical resting posture (CRP) of the head in sagittal plane was measured by Cervical-Range-of-Motion $^\textregistered$(CROM, U.S.A.) and lateral cephalograph was taken in natural posture. The items related to angle in cephalograph were the angles of cranial and cervical inclination to true vertical line(VER/NSL, VER/AML), the angles of cervical inclination to nasion-sella line(CVT/NSL, OPT/NSL), the angles of comical inclination to horizontal line(CVT/HOR, OPT/HOR), the angle of cervical lordosis(CVT/OPT). The items related to line measurement were the distance from subocciput to Cl(Dl), Cl to C2(D2), C2 to C3(D3), C3 to C4(D4), the upper(PNS to posterior pharyngeal wall) and the lower(tongue base to posterior pharyngeal wall) pharyngeal space, the distance from nation to mention(Na-Me), and the radius of comical curvature from the first comical vertebra(Cl ) to the fifth cervical vertebra(C5). The data were analyzed with SAS/STAT program. The obtained results were as follows : 1. Most items related to angular measurement showed significant difference between in standing and sitting posture. The angles of CRP, CVT/NSL, OPT/NSL, CVT/HOR, OPT/HOR, and CVT/OPT were high in sitting posture, but the angles of VER/NSL, VER/NSL were low in sitting posture. 2. In vertebral distance, only the distance between C3 and C4 was differed by the posture, which decreased in sitting posture. In sitting posture, the distance from nasion to menton(Na-Me) was longer, but the radius was shorter than in standing posture. 3. Correlationship in angular measurements was almost same in both postures. Ceervical resting posture(CRP) was correlated with VER/NSL, VER\ulcornerNSL was correlated with CRP, CVT/NSL, and OPT/NSL, VER/AML was correlated with CVT/HOR, OPT/HOR, CVT/OPT, and the angle of cervical lordosis(CVT/OPT) was correlated with the radius. 4. Correlationship in linear measurement was observed only in among D3, D4, and radius. And the Na-Me was not correlated with any other items. From this results, The author concluded that the head posture in sitting was mote backward extended than in standing.

  • PDF

A Study on the Head and Neck Posture Related to Cervical Curvature in Patients with Craniomandibular Disorders (경추만곡도를 이용한 두개하악장애에 환자의 두경부자세에 관한 연구)

  • Min-Shin;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.361-376
    • /
    • 1995
  • The purpose of this study was to investigate the relationship between the head and neck postre and the cervical curvature, especially in forward head postrue(FHP). Sixty patients with craniomandibular disorders and thirty dental students without any signs and symptoms of craniomandibular disordres participated in this study as patient groups and sa control group, respectively. The author evaluated the head and neck posture of all subjects by plumb line and CROM( Cervical Ragne of Motion), and had taken cephaograph in natural head position. On the cephalograph the angle of cervical inclination formed by true horizntal plane and 4th cervical vertebra(C4) and the radius of cervical curvature from C1 to C5 were measured. A specially designed ruler was used for measuring cervical curvature. Occlusal contac number and force with T-scan system, electromygraphic activity of cervical muscles with Bio-EMG, and distance of freeway space with Bio-ECN were recorded, respectively. The collected data were processed by SAS/STAT progrm. The obtained results were as follows : 1. In subjects with longer radius which was less cervical curvature, head positioned more anteriorly than subjects with smaller radius, and they showed slightly straight cervical vertebra. 2. Between the patients and the control group, there were no differences in cervical curvature, in forward head position by plumb line and in CROM. But the patient group had a greater cervical inclination than the control group had. 3. There were positive correlation between cervical curvature and forward head position by plumbline,between forward head position y plumb line and that by CROM in patient group. The cervical inclination, however, had negative correlation with cervical curvature, and with forward head postion by plumb line, respectively. 4. In case of showing more cervical curvature and more forward head position by plumb line the head position was defined as forward head posture. In patient group, subjects without forward head posture showed greater posterior teeth contact force than subjects with forward head posture, but in control group, there were no difference between the two subjects. 5. There were higher electromyographic activity in almost all muscles and smaller freeway space in induced forward head posture than those in natural head position in subjects without forward head posture. In conclusion, head position of patients with craniomandibular disorders were not more anterior than that of normal control person, but they had tendency to head extension. From the result of this study, forward head posture could be defined as posterior rotation of upper cervical segment with a straight lower cercial segment due to loss of normal lordosis.

  • PDF

Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography (복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향)

  • Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF