• Title/Summary/Keyword: Plane of motion

Search Result 785, Processing Time 0.032 seconds

Some Limit Theorems for Fractional Levy Brownian Motions on Rectangles in the Plane

  • Hwang, Kyo-Shin;Kang, Soon-Bok;Park, Yong-Kab;Jeon, Tae-Il;Oh, Ho-Seh
    • Journal of the Korean Statistical Society
    • /
    • v.28 no.1
    • /
    • pp.1-19
    • /
    • 1999
  • In this paper we establish some limit theorems for a two-parameter fractional Levy Brownian motion on rectangles in the Euclidean plane via estimating upper bounds of large deviation probabilities on suprema of the two-parameter fractional Levy Brownian motion.

  • PDF

A Study on Motion Estimator Design Using Bit Plane (비트 플레인을 이용한 움직임 추정기 설계의 관한 연구)

  • 김병철;조원경
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.403-406
    • /
    • 1999
  • Among the compression methods of moving picture information, a motion estimation method is used to remove time-repeating. The Block Matching Algorithm in motion estimation methods is the commonest one. In recent days, it is required the more advanced high quality in many image processing fields, for example HDTV, etc. Therefore, we have to accomplish not by means of Partial Search Algorithm, but by means of Full Search Algorithm in Block Matching Algorithm. In this paper, it is suggested a structure that reduce total calculation quantity and size, because the structure using Bit Plane select and use only 3bit of 8bit luminance signal.

  • PDF

A review on measuring cervical range of motion using an inertial measurement unit (관성측정장치를 이용한 경추 가동범위 측정에 대한 고찰)

  • Yim, Juhyuk;Kim, Hyunho;Park, Young-Jae;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.56-71
    • /
    • 2017
  • Objectives: The purpose of this study was to review the article using an IMU(Inertial Measurement Unit) for measuring the cervical range of motion and to evaluate the feasibility of using an IMU for measuring the cervical range of motion. Method: Scopus was used to search for the articles relating to the inclusion criteria. Which is measuring the cervical range of motion using an IMU. A total of 15 articles were selected through discussion. Degree and the reliability of the cervical range of motion and the validity of the data within the articles were extracted. Results: The measurement of the cervical range of motion using an IMU were $92.25^{\circ}$ to $138.2^{\circ}$, $122.4^{\circ}$ to $154.9^{\circ}$, $73.75^{\circ}$ to $93.1^{\circ}$ on the sagittal plane, transverse plane, and coronal plane respectively. 38 of the 43 values showed good reliability. They were larger than 0.75. 5 of the 43 values showed reliability less than 0.75. They were measured by smart phone. 16 of the 21 values showed good validity. The remaining 5 were measured by smart phone. The lower reliability and validity of smart phone were related to the protocol. The IMU can measure the coupling motion and may be used in various situations. Conclusion: The IMU may become a gold standard for measuring the cervical range of motion. The IMU measured not only the cervical range of motion but also the coupling motion. Furthermore, IMU may be used in various situations. Therefore, IMU must be considered a valuable measurement device.

A Finite Thin Circular Beam Element for In-Plane Vibration Analysis of Curved Beams

  • Kim Chang-Boo;Park Jung-Woo;Kim Sehee;Cho Chongdu
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2187-2196
    • /
    • 2005
  • In this paper, the stiffness and the mass matrices for the in-plane motion of a thin circular beam element are derived respectively from the strain energy and the kinetic energy by using the natural shape functions of the exact in-plane displacements which are obtained from an integration of the differential equations of a thin circular beam element in static equilibrium. The matrices are formulated in the local polar coordinate system and in the global Cartesian coordinate system with the effects of shear deformation and rotary inertia. Some numerical examples are performed to verify the element formulation and its analysis capability. The comparison of the FEM results with the theoretical ones shows that the element can describe quite efficiently and accurately the in-plane motion of thin circular beams. The stiffness and the mass matrices with respect to the coefficient vector of shape functions are presented in appendix to be utilized directly in applications without any numerical integration for their formulation.

Digital image stabilization based on bit-plane matching (비트 플레인 정합에 의한 디지털 영상 안정화)

  • 이성희;전승원;고성제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1471-1481
    • /
    • 1998
  • In this paper, we propose a new digital image stabilization scheme based on the bit-plane matching. In the proposed algorithm, the conventional motion estimation algorithms are applied to the binary images extracted from the bit-plane images. It is shown that the computational complexity of the proposed algorithm can be significantly reduced by replacing the arithmetic calculations with the binary Boolean functions, while the accuracy of motion estimation is maintained. Furthermore, an adaptive algorithm for selecting a bit-plane in consideration of changes in external illumination can provide the robustness of the proposed algorithm. We compared the proposed algorithm with existing algorithms using root mean square error (RMSE) on the basis of the brute-force method, and proved experimentally that the proposed method detects the camera motion more accurately than existing algorithms. In addition, the proposed algorithm performs digital image stabilization with less computation.

  • PDF

Cancellation of MRI Motion Artifact in Image Plane (촬영단면내의 MRI 체동 아티팩트의 제거)

  • Kim, Eung-Kyeu
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.309-312
    • /
    • 2000
  • In this work, a new algorithm for canceling MRI artifact due to translational motion in image plane is described. In the previous approach, the motions in the x direction and the y direction are estimated simultaneously. By analyzing their features, each x and y directional motion is canceled by different algorithms in two steps. First, it is noticed that the x directional motion corresponds to a shift of the x directional spectrum of the MRI signal. Next, the y directional motion is canceled by using a new constraint condition. This algorithm is shown to be effective by using a phantom image with simulated motion.

  • PDF

Tool Path Analysis and Motion Control of 3D Engraving Machine

  • Smerpitak, Krit;Pongswatd, Sawai;Ukakimapurn, Prapart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1245-1248
    • /
    • 2004
  • This paper presents a new technique to analyze data on the coordinate x, y, z and apply these data to design the motion control to improve the efficiency of the engraving machine so that it can engrave accordingly in 3 dimensions. First, the tool path on the x-y plane is analyzed to be synchronized with the z-axis. The digital data is then sent to the motion control to guide the movement of the engrave point on the x-y plane. Tool path moves along the x-axis with zero degree and different values of the y-axis according to the coordinate of the digital data and the analysis along z-axis to determine the depth for engraving. The depth can be specified from the gray level with the 256 levels of resolution. The data obtained includes the distances on x-axis, y-axis, and z-axis, the acceleration of the engrave point's movement, and the speed of the engrave point's movement. These data is then transfered to the motion control to guide the movement of the engrave point along the z-axis associated with the x-y plane. The results indicate that engraving using this technique is fast and continuous. The specimen obtained looks perfect in 3D view.

  • PDF

Cancellation of MRI Motion Artifact in Image Plane

  • Kim Eung-Kyeu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2000
  • In this study, a new algorithm for canceling a MRI artifact due to the translational motion In the image plane is described. Unlike the conventional iterative phase retrieval algorithm, in which there is no guarantee for the convergence, a direct method for estimating the motion is presented. In previous approaches, the motions in the x(read out) direction and the y(phase encoding) direction were estimated simultaneously. However, the feature of x and y directional motions are different from each other. By analyzing their features, each x and y directional motion is canceled by the different algorithms in two steps. First, it is noticed that the x directional motion corresponds to a shift of the x directional spectrum of the MRI signal, and the non-zero area of the spectrum just corresponds to the projected area of the density function on the x axis. So the motion is estimated by tracing the edges between non-zero area and zero area of the spectrum, and the x directional motion is canceled by shifting the spectrum in an reverse direction. Next, the y directional motion is canceled by using a new constraint condition, with which the motion component and the true image component can be separated. This algorithm is shown to be effective by using a phantom image with simulated motion.

  • PDF

Elastic Wave Propagation in Monoclinic System Due to Harmonic Line Load

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.2E
    • /
    • pp.47-52
    • /
    • 1998
  • An analysis of dynamic responses is carried out on monoclinic anisotropic system due to a buried harmonic line source. The load is in the form of a normal stress acting along an arbitrary axis on the plane of symmetry within the orthotropic materials: In case that the line load is acting along the symmetry axis normal to the plane of symmetry, plane wave equation is coupled with verital shear wave and longitudinal wave. However, if the line load is acting along an arbitrary axis normal to the plane of symmetry, plane wave equation is coupled with vertical shear wave, longitudinal wave and horizontal shear wave. We first considered the equation of motion in a reference coordinate system, where the line load is coincident with a symmetry axis of the orthotropic material. Then the equation of motion is transformed into one with respect to general coordinate system with azimuthal angle by using transformation tensor. Plane wave solutions of monoclinic systems are derived for infinite media. Finally complete solutions for the plane harmonic wave are obtained by calculating the inverse of the integral transforms, in which bulk wave poles are avoided by deforming the contour of the integration to the complex plane. Numerical results for examples of orthotropic material belonging to monoclinic symmetry are demonstrated.

  • PDF

Motion Analysis at Proprioceptive Neuromuscular Facilitation Patterns (고유수용성 신경근 촉진법 패턴의 운동 분석)

  • Bae Sung-Soo;Chung Hyung-Kuk;Kim Ho-Bong
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.213-221
    • /
    • 1998
  • The purpose of this study was a motion analysis of proprioceptive neuromuscular facilitation patterns which is scapular and pelvis patterns, upper extremity patterns, lower extremity patterns, trunk patterns. The patterns combine motion in sagittal plane for flextion and extension, coronal or frontal plane for abduction and adduction, transverse plane for rotation. The patterns composed of mass movement pattern of the limbs and trunk muscles. Every pattern can change by changing the activity of the middle joint in the extremity patterns and changing the patient's positions.

  • PDF