• Title/Summary/Keyword: Plan Variation

Search Result 323, Processing Time 0.025 seconds

The Developing Plan for Agricultural Cooperatives' Mutual Credits (농협(農協)의 상호금융(相互金融) 현황(現況)과 발전방안(發展方案))

  • Shin, Yong In;Cho, Won Sang
    • Korean Journal of Agricultural Science
    • /
    • v.25 no.2
    • /
    • pp.329-342
    • /
    • 1998
  • As we have said major contents in the background of inducing Mutual Credits, Agricultural Cooperatives' Mutual Credits are absolutely necessary to the development of rural community. In real aspects, since it has been introduced, Mutual Credits have contributed greatly to the rural prosperity, as we have studied in the actual state of Mutual Credits. But with the advent of WTO system, both the international situation of open-trade policy and the domestic one of free banking and deregulation were rapidly going on at the same time, there by Mutual Credits' business has been threated by them. So Mutual Credits had to seek some programs for development in order to solve the hard situation. Several points on development programs of Mutual Credits are as follows: (1) Realization of scale of economy by the way of M&A among small primary cooperatives (2) Development of new financial products for raising funds safely (3) Management-rationalization by automatic systems like cash dispenser and telebanking (4) Variation of business area (5) Enforcing economy-business part besides Mutual Credits' one among cooperative businesses (6) Government's successive support.

  • PDF

Lower Incisor Extraction for Dental Camouflage (하악전치발치를 통한 교정)

  • Lee, Won-You;Lee, Young-Taek
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.661-668
    • /
    • 1997
  • There is a variation in the range of normal occlusion, and we must fit our treatment to the needs of each patient. If the upper or lower incisors are congenital)y missing, malformed, or crowded, the extraction of the incisor has some advantages over the extraction of premolars and nonextractions. The advantages are 1)simple mechanics, 2)reduced treatment time, 3)less relapse tendency, and 4)fewer facial profile changes. In order to decide which incisor should be extracted, we must consider certain factors 1)discrepancies in anterior arch length, 2)anterior tooth ratio, 3)periodontal and tooth health condition, and 4)the relationship between the upper and lower midline. Diagnostic set-up can be helpful to plan the treatment and show us the post treatment result.

  • PDF

Job Analysis of Medical Care Client Managers based on DACUM (데이컴 (DACUM)기법을 이용한 의료급여관리사의 직무분석)

  • Choi, Jeong-Myung
    • Korean Journal of Occupational Health Nursing
    • /
    • v.20 no.3
    • /
    • pp.299-307
    • /
    • 2011
  • Purpose: The purpose of this study is to establish the standards for duty of Medical Care Client Managers and analyze the extent of accomplishment, importance, and difficulty according to the standards. Methods: The draft for duty of Medical Care Client Managers was formed by the method of developing a curriculum (DACUM) and data were collected from 185 Medical Aid Client Managers in 234 areas to evaluate the actual frequency of accomplishment, importance and difficulty in comparison with the standards for duties. Results: The standard duty draft for Medical Care Client Manager is composed of five separate groups of duties and thirty five tasks. The five duties are Case Management, Extension Approval, External Cause of Injury, Duplicate Claims and Other Administrations. Seven Tasks are allocated to each duty such as Case Management, Extension Approval and External Cause of Injury. Five tasks are allocated to 'Duplicate Claims' duty and nine tasks are allocated to 'Other Administrations' duty. Conclusion: From the results of analysis for duties, it was apprehensive about overburdened responsibilities and carelessness in professional duties. It was necessary to establish specific guidelines for duties because of redundent application or regional variation in frequency of accomplishing other administrative duties. It was necessary to relieve a regional disparity of business charge and also was necessary to propose an alternative plan to relieve the overburdened responsibilities.

Comparison between a 13-session and One-time Program on Korean Elementary, Middle and High School Students' Understanding of Nuclear Power

  • Han, Eun Ok;Choi, YoonSeok;Lim, YoungKhi
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.56-62
    • /
    • 2017
  • Background: To help future generations make accurate value judgments about nuclear power generation and radiation, this study will provide an effective education plan suitable for South Korea by applying and analyzing programs for the understanding of nuclear power within the diversely operated programs in the current Korean education system. Materials and Methods: This study analyzed the difference in educational effects by operating a 13-session regular curriculum for one semester and a one-session short-term curriculum from March to July 2016. Results and Discussion: As a result of operating a 13-session model school and a one-time educational program to analyze behavior changes against the traditional learning model, it was found that all elementary, middle and high school students showed higher acceptability of nuclear power in South Korea. The variation was greater for the model school than the short-term program. Conclusion: To prevent future generations from making biased policy decisions stemming from fear regarding nuclear power, it is necessary to bolster their value judgments in policy decisions by acquiring sufficient information about nuclear power generation and radiation through educational programs.

Evaluation of Lighting Environment of Residential Space for Senior People by each Life Behavior with Mock-up Model (실물대 모형을 이용한 고령자 주거공간의 생활행위별 조명환경 평가에 관한 연구)

  • Kim, Byoung Soo;Yim, Oh Yon
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.35-40
    • /
    • 2007
  • The purpose of this study is to execute evaluation experiment to know the evaluation property of lighting environment of residential space for senior people, considering visual characteristics along aging, and finally provide basic data for the lighting plan to ensure the visual amenity. Processes of this study are as follows;1) Analyzed the variation property of visual sensibility and visual ability of senior people along aging. 2) Selected 3 types of life behavior(rest, conversation and reading) after checking life behavior in residential space for senior people based on advanced study. 3) Made the Mock-up Model that Dimming is possible, actual furnace to model. 4) Executed sensitivity evaluation experiment about lighting environment. 5) Analyzed evaluation property of lighting environment of residential space for senior people. Results of this study are as follows, 1) With lens-filter, we got comfort and amenity in bulb-color lamp which has similar color temperature with red of lens filter. 2) Lighting environment tests during conversation : With lens filters, they felt comfort on bulb color in case of higher illuminance than 850lux and daylight color in 500lux. 3) Lighting environment tests at reading : With lens filter, bulb color got better score in brightness and appropriateness than daylight color.

Propagation Characteristics and Effects of Road Traffic Noise (도로교통소음의 전파특성 및 영향)

  • Park, Joon-Cheol;Kim, Yoon-Shin;Kang, Dae-Joon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.4
    • /
    • pp.311-315
    • /
    • 2008
  • This study was performed to investigate propagation characteristics and effects of road traffic noise generated from vehicles. Noise levels of expressway and general road were measured at four points in a straight line based on distance from the road, and analyzed. The average noise level of expressway was 78.9 dBA at 5 m, 76.4 dBA at 10 m, 72.0 dBA at 20 m, 69.0 dBA at 30 m. That of general road was lower about $3.1{\sim}3.5\;dBA$ than that of expressway. There was no significant difference in distance attenuation between expressway noise and general road noise. The farer the distance from source is, the more the attenuation is. The influence range of noise is assessed by noise environmental standards or road noise limits. Noise levels of the time zone were measured at a boundary line of apartment to grasp noise variation by time. The time zone of lowest noises was $3{\sim}4$ a.m. and that of highest noise was $8{\sim}10$ a.m. Data recorded on tapes were analyzed to understand the characteristics of frequency because these characteristics are important factors to plan the noise reduction measures, namely path measures.

Economics of Self-Generation by Natural Gas Industry Using the Mixed Integer Program (혼합정수계획법을 이용한 천연가스(LNG) 산업의 자가발전소 건설에 대한 경제성 분석)

  • Lee, Jeong-Dong;Byun, Sang-Kyu;Kim, Tai-Yoo
    • IE interfaces
    • /
    • v.13 no.4
    • /
    • pp.658-667
    • /
    • 2000
  • Seasonal variation of natural gas demand coupled with rigid and stable import pattern of gas represents the characteristic feature of the Korean Liquified Natural Gas(LNG) industry. This attribute has required a huge amount of investment for the construction of storage facility. Thus, to minimize the supply cost, it is legitimate to reduce storage requirement itself. In this study, we combine three alternative methods to deal with the storage requirement to minimize the supply cost. Those are (1) adding additional storage tanks, (2) inducing large firm customers, and (3) constructing gas-turbine self generation facilities. Methodologically, we employ the mixed integer program (MIP) to optimize the system. The model also consider demand and price-setting scheme in separate modules. From the results, it is shown that if alternatives are combined optimally, a number of storage tanks can be reduced substantially compared with the original capacity plan set by the industry authorities. We perform various sensitivity analyses to check the robustness of the results. The methodology presented in this study can be applied to the other physical network industry, such as hydraulics. The empirical results will shed some light on the rationalization of capacity planning of the Korean natural gas industry.

  • PDF

A Study on the Development of Simulation Model for Inchon Port (인천내항을 위한 시뮬레이션 모델 개발 +)

  • 김동희;김봉선;이창호
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.73-81
    • /
    • 1999
  • Inchon Port is the second largest import-export port of Korea, and has the point ant issue such as the excessive logistics cost because of the limits of handing capacity and the chronic demurrage. There is few research activities on the analysis and improvement of the whole port operation, because Inchon Port not only has the dual dock system and various facilities but also handles a various kind of cargo. The purpose of this paper is to develop the simulation program as a long-term strategic support tool, considering the dual dock system and the TOC(terminal operation company) system executed from March, 1997 in Inchon Port. The basic input parameters such as arrival intervals, cargo tons, service rates are analyzed and the probability density function for this parameters are estimated. The main mechanism of simulation model is the discrete event-driven simulation and the next-event time advancing. The program is executed based on the knowledge base and database, and is constructed using VISUAL BASIC and ACCESS database. From the simulation model, it is possible to estimate the demurrage status through analyzing scenarios such as the variation of cargo ton and cargo handing level, the increase of service rate, and so on, and to establish the long-term port strategic plan.

Minimum stiffness of bracing for multi-column framed structures

  • Aristizabal-Ochoa, J. Dario
    • Structural Engineering and Mechanics
    • /
    • v.6 no.3
    • /
    • pp.305-325
    • /
    • 1998
  • A method that determines the minimum stiffness of baracing to achieve non-sway buckling conditions at a given story level of a multi-column elastic frame is proposed. Condensed equations that evaluate the required minimum stiffness of the lateral and torsional bracing are derived using the classical stability functions. The proposed method is applicable to elastic framed structures with rigid, semirigid, and simple connections. It is shown that the minimum stiffness of the bracing required by a multi-column system depends on: 1) the plan layout of the columns; 2) the variation in height and cross sectional properties among the columns; 3) the applied axial load pattern on the columns; 4) the lack of symmetry in the loading pattern, column layout, column sizes and heights that cause torsion-sway and its effects on the flexural bucking capacity; and 5) the flexural and torsional end restrains of the columns. The proposed method is limited to elastic framed structures with columns of doubly symmetrical cross section with their principal axes parallel to the global axes. However, it can be applied to inelastic structures when the nonlinear behavior is concentrated at the end connections. The effects of axial deformations in beams and columns are neglected. Three examples are presented in detail to show the effectiveness of the proposed method.

System Performance with Variation of Outdoor Unit Layouts at Building Re-entrants

  • Koh, Jae-Yoon;Lee, Hyun-Gu;Zhai, John
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • Air-cooled split-type air conditioners (AC) are very popular in high-rise residential and commercial buildings in Korea. The performance of such AC systems varies significantly with system characteristics and environmental conditions. Particularly, the outdoor condensing unit of the system, if poorly cooled due to high density of AC distribution and restricted outdoor space, will result in large decrease of cooling efficiency and increase of electrical energy consumption and may further jeopardize the system reliability. This paper presents a numerical analysis on the thermal and energy performance of a group of air-cooled air conditioners installed at a courtyard of a high-rise building. The study introduces a series of new energy performance indices to assess the group performance of the AC condensers with different outdoor unit layouts. The results not only indicate the COP of the systems, but also quantify the system capacity and energy consumption. The evaluation method and indices developed are useful for guiding the design of the distribution plan of the AC units at building re-entrants.