• 제목/요약/키워드: Placement head

검색결과 58건 처리시간 0.024초

Fast Component Placement with Optimized Long-Stroke Passive Gravity Compensation Integrated in a Cylindrical/Tubular PM Actuator

  • Paulides, J.J.H.;Encica, L.;Meessen, K.J.;Lomonova, E.A.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.275-282
    • /
    • 2013
  • Applications such as vibration isolation, gravity compensation, pick-and-place machines, etc., would benefit from (long-stroke) cylindrical/tubular permanent magnet (PM) actuators with integrated passive gravity compensation to minimize the power consumption. As an example, in component placing (pick-and-place) machines on printed circuit boards, passive devices allow the powerless counteraction of translator including nozzles or tooling bits. In these applications, an increasing demand is arising for high-speed actuation with high precision and bandwidth capability mainly due to the placement head being at the foundation of the motion chain, hence, a large mass of this device will result in high force/power requirements for the driving mechanism (i.e. an H-bridge with three linear permanent magnet motors placed in an H-configuration). This paper investigates a tubular actuator topology combined with passive gravity compensation. These two functionalities are separately introduced, where the combination is verified using comprehensive three dimensional (3D) finite element analyses.

인쇄회로기판 조립공정에 있어서 여러 개의 헤드를 가진 부품자동삽입기의 효율적 운용 (Efficient Operation of a Component Placement Machine with a Multi - head in a PCB Assembly Process)

  • 박성수;손진현
    • 대한산업공학회지
    • /
    • 제20권4호
    • /
    • pp.23-35
    • /
    • 1994
  • Efficient operation of a component placement machine with a multi-head in a PCB assembly process is considered. The problem consists of two subproblems, which are the optimal allocation of the component tape reels in the rack and the optimal mounting sequence of the components on a printed circuit board. We analyze the problem and propose a heuristic algorithm to solve it. The heuristic can be used for the one head case too. Computational experiences on some real world problems show the effectiveness of the heuristic in terms of speed and solution quality.

  • PDF

Measurement of Skull Size on Computed Tomography Images for Developing a Bone Conduction Headset Suitable for the Korean Standard Head Size

  • Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
    • Journal of Audiology & Otology
    • /
    • 제24권1호
    • /
    • pp.17-23
    • /
    • 2020
  • Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.

Measurement of Skull Size on Computed Tomography Images for Developing a Bone Conduction Headset Suitable for the Korean Standard Head Size

  • Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
    • 대한청각학회지
    • /
    • 제24권1호
    • /
    • pp.17-23
    • /
    • 2020
  • Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.

FPS 공정에 의한 열경화성 복합재 유효성 검증 연구 (A Study on Property of Thermoset Composite in FPS Process)

  • 김진현;엄문광;변준형;이상관;전영준
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.241-245
    • /
    • 2004
  • Among the various manufacturing processes of composites, the tape lay-up process of thermoset prepreg has many advantages compared to autoclave or hot press forming. It has a high potential to process automation and continuous fabrication .. Fiber placement developed as a logical combination of filament winding and automated tape placement to overcome some of the limitations of each manufacturing method. Fiber placement uses a compaction device to apply direct contact between the incoming materials in the fiber placement head and Heat is added to the materials at the nip point of the compaction roller. This paper will discuss property of thermoset composite as compaction and heat effect in Automated fiber placement

  • PDF

머리 움직임 인식을 위한 근전도 신호의 패턴 인식 기법에 관한 연구 (A Study on the Pattern Recognition of EMG Signals for Head Motion Recognition)

  • 이태우;전창익;이영석;유세근;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권2호
    • /
    • pp.103-110
    • /
    • 2004
  • This paper proposes a new method on the EMG AR(autoregressive) modeling in pattern recognition for various head motions. The proper electrode placement in applying AR or cepstral coefficients for EMG signature discrimination is investigated. EMG signals are measured for different 10 motions with two electrode arrangements simultaneously. Electrode pairs are located separately on dominant muscles(S-type arrangement), because the bandwidth of signals obtained from S-type placement is wider than that from C-type(closely in the region between muscles). From the result of EMG pattern recognition test, the proposed mIAR(modified integrated mean autoregressive model) technique improves the recognitions rate around 17-21% compared with other the AR and cepstral methods.

Can Right-Handed Surgeons Insert Upper Thoracic Pedicle Screws in much Comfortable Position? Right-Handedness Problem on the Left Side

  • Akyoldas, Goktug;Senturk, Salim;Yaman, Onur;Ozdemir, Nail;Acaroglu, Emre
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권5호
    • /
    • pp.568-573
    • /
    • 2018
  • Objective : Thoracic pedicles have special and specific properties. In particular, upper thoracic pedicles are positioned in craniocaudal plane. Therefore, manipulation of thoracic pedicle screws on the left side is difficult for right-handed surgeons. We recommend a new position to insert thoracic pedicle screw that will be much comfortable for spine surgeons. Methods : We retrospectively reviewed 33 patients who underwent upper thoracic pedicle screw instrumentation. In 15 patients, a total of 110 thoracic pedicle screws were inserted to the upper thoracic spine (T1-6) with classical position (anesthesiologist and monitor were placed near to patient's head. Surgeons were standing classically near to patient's body while patients were lying in prone position). In 18 patients, a total of 88 thoracic pedicle screws were inserted to the upper thoracic spine with the new standing position-surgeons stand by the head of the patient and the anesthesia monitor laterally and under patient's belt level. All the operations performed by the same senior spine surgeons with the help of C-arm. Postoperative computed tomography scans were obtained to assess the screw placement. The screw malposition and pedicle wall violations were divided and evaluated separately. Cortical penetration were measured and graded at either : 1-2 mm penetration, 2-4 mm penetration and >4 mm penetration. Results : Total 198 screws were inserted with two different standing positions. Of 198 screws 110 were in the classical positioning group and 88 were in the new positioning group. Incorrect screw placement was found in 33 screws (16.6%). The difference between total screw malposition by both standing positions were found to be statistically significant (p=0.011). The difference between total pedicle wall violations by both standing positions were found to be statistically significant (p=0.003). Conclusion : Right-handedness is a problem during the upper thoracic pedicle screw placement on the left side. Changing the surgeon's position standing near to patient's head could provide a much comfortable position to orient the craniocaudal plane of the thoracic pedicles.

MZR 디스크를 채택한 VOD 저장서버의 효율적인 비디오 블록 배치방법 (An Effective Video Block Placement Strategy on VOD Storage Server with MZR Disks)

  • 임형룡;김정원;김영주;정기동
    • 한국정보처리학회논문지
    • /
    • 제4권12호
    • /
    • pp.2971-2984
    • /
    • 1997
  • 본 논문에서는 MZR 디스크의 특성과 VOD에서 사용자들의 접근 편기성을 고려한 비디오 블록의 효율적 배치방법을 제안한다. 또 제안된 방법에 대하여 VOD 서버의 모델링과 모의실험을 통하여 성능을 평가하였다. 기본적인 방법은 인기도에 따라 Zipf 분포를 고려하여 MZR 디스크상에 선형배치나 편기된 휴리스틱(SH) 방법으로 배치시키는 것이다. 제안된 방법의 타당성을 검증하기 위해서, 2 대의 디스크를 설치한 워크스테이션에서 다양한 편기요인 하에서의 성능을 실험하였다. 실험결과 여기에서 제시한 방법이 임의배치 방법보다 좋은 성능을 보여주고 있음을 알 수 있다. 디스크 그룹으로 배치방법을 확장하기 위하여 동시에 지원 가능한 최대 사용자 수와 사용자당 필요한 버퍼의 크기를 분석하였다. 제안된 방법의 수행력에 관련한 변수로는 디스크헤드 스케쥴링 방법, 배치방법, 스트라이핑 단위 등을 고려하였으며 실험결과 본 논문에서 제시한 방법이 효율적임을 알 수 있다.

  • PDF

Autograft Surgery Using the Condylar Fragment for Implant Placement

  • Kim, Yeo-Gab;Kwon, Yong-Dae;Yoon, Byung-Wook;Choi, Byung-Joon;Yu, Yong-Jae;Lee, Baek-Soo
    • Journal of Korean Dental Science
    • /
    • 제1권1호
    • /
    • pp.10-14
    • /
    • 2008
  • The fracture of facial bone usually accompanies alveolar bone fracture and dislocation or fracture of teeth. Thus, aside from the reduction of fracture, the reconstruction of occlusion through the rehabilitation of lost teeth should be considered. The dislocation of tooth after trauma accompanying alveolar bone fracture needs bone grafting in case of implant treatment. Although autogenous bone graft shows good prognosis, it has the disadvantage of requiring a secondary surgery. This is a case of a mandibular condyle head fracture accompanied by alveolar bone fracture. The condylar head fragment removed during open reduction was grafted to the alveolar bone fracture site, thereby foregoing the need for secondary surgery.

  • PDF

한국 자치경찰의 인력충원 방안 (Policy of Personnel Recruiting in the Korean Municipal Police System)

  • 김종수;신승균
    • 한국콘텐츠학회논문지
    • /
    • 제8권7호
    • /
    • pp.182-194
    • /
    • 2008
  • 본 연구는 자치경찰제 시행이념을 구현하고 주민친화적인 치안서비스를 제공하는데 적합한 인력을 충원하기 위한 현실적인 대안을 제시하는데 목적을 두고 있다. 자치경찰제의 실시가 가시화되고 있는 만큼 자치경찰의 인력충원을 위한 실증적 연구는 의미가 있을 것이다. 이에 따라 이에 대한 연구가 향후 자치경찰법안의 입법과정과 자치경찰제의 안정된 정착에 기여할 수 있을 것으로 보고, 이에 대한 세부적 방안을 모집 및 채용, 교육훈련, 신규배치로 구분하여 제시하였다. 먼저 모집 및 채용영역에서는 지역실정에 부합한 자치경찰 모집의 필요성과 지방행정의 집행력을 강화하기 위한 특사경 전문가의 확보방안을 제시하였으며, 주민친화적 경찰행정을 구현하기 위한 여성인력 확보방안을 제시하였다. 그리고 채용시험의 직무적 합성 확보방안과 자치경찰사무 관련 자격증에 대한 가산점 부여방안, 개방형공모 제도를 통한 자치경찰대장 임용방안을 제시하였다. 교육훈련 영역에서는 지역 내 자치경찰 교육훈련 기관의 확보방안과 지역대학과의 연계교육을 통한 자치경찰 교육훈련의 실효성 확보방안을 제시하였으며, 자치경찰 전문직무교육 과정을 제시하였다. 끝으로 신규배치 영역에서는 지역출신자들에 대한 우선배치의 필요성과 자치경찰의 전문성 확보를 위한 제한적 배치방안을 제시하였으며, 국가경찰과의 정기적 인사교류의 필요성을 강조하였다.