• 제목/요약/키워드: Placement distance

검색결과 146건 처리시간 0.022초

임플란트 매식 시 수직골 높이에 따른 응력분석 (Stress analysis according to the vertical bone level in the implant placement)

  • 김민호;박영록;계기성
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.301-311
    • /
    • 2002
  • The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different vertical bone level of implant fixture. The two kinds of finite element models were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$). The cemented crowns for mandibular first and second molars were made. Three- dimensional finite element model was created with the components of the implant and surrounding bone. Vertical loads were applied with force of 200N distributed within 0.5mm radius circle from the center of central fossa and distance 2mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the supporting bone, fixtures, abutment screws, and crown. The results were as following : (1) In vertical loading at the center circle of central fossa on model 1 and 2, the difference from vertical bone in implant placement did not affect the stress pattern on all components of implant except for crown. (2) With offset distance incerasing and the bone level of implant decreasing, the concentration of stress occured in the buccal side of long crown, around the buccal crestal bone, and on the fixture- abutment interface. As a conclusion, the research showed a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the vertical level of bone around fixture was different. Since the same vertical bone bed has more benefits than the different bone bed around fixtures, it is important to prepare a same vertical level of bone bed for the success of implants under occlusal loads.

Design of Autonomous Cruise Controller with Linear Time Varying Model

  • Chang, Hyuk-Jun;Yoon, Tae Kyun;Lee, Hwi Chan;Yoon, Myung Joon;Moon, Chanwoo;Ahn, Hyun-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2162-2169
    • /
    • 2015
  • Cruise control is a technology for automatically maintaining a steady speed of vehicle as set by the driver via controlling throttle valve and brake of vehicle. In this paper we investigate cruise controller design method with consideration for distance to vehicle ahead. We employ linear time varying (LTV) model to describe longitudinal vehicle dynamic motion. With this LTV system we approximately model the nonlinear dynamics of vehicle speed by frequent update of the system parameters. In addition we reformulate the LTV system by transforming distance to leading vehicle into variation of system parameters of the model. Note that in conventional control problem formulation this distance is considered as disturbance which should be rejected. Consequently a controller can be designed by pole placement at each instance of parameter update, based on the linear model with the present system parameters. The validity of this design method is examined by simulation study.

전방 십자 인대 재건술시 대퇴 터널의 위치에 대한 방사선학적 평가 (Radiographic Evaluation of Femoral Tunnel Placement During ACL Reconstruction)

  • 정현기;최충혁;이중학
    • 대한관절경학회지
    • /
    • 제2권1호
    • /
    • pp.80-84
    • /
    • 1998
  • The isometric position for the graft is important in the anterior cruciate ligament reconstruction surgery. It is well known that the femoral position is more critical than tibial side. But, there is few deciding method of proper graft position after the anterior cruciate ligament reconstruction surgery. So we planned to evaluate the ideal femoral isometric position with 6 adult cadavaric femurs and exact radiographs. After the insertion of femoral interference screw on ideal isometric position, we obtained roentgenograms of true lateral view and 10, 20, 30, 45 degree internal and external rotation views. Then we measured the shortest distance from the posterior cortical margin of lateral femoral condyle to posterior border of interference screw on the radiographs. We also measured true distance between posterior cortical margin of lateral femoral condyle to the posterior margin of femoral tunnel after cutting of distal femur. Based on this study, we could not determine the permissible rotation degree of radiographs. But we concluded that if the distance between posterior cortical margin of lateral femoral condyle and posterior border of interference screw ranges 4.5-6.5mm on the lateral view, the femoral position is considered as a relatively ideal isometric good position.

  • PDF

A Novel Method for Virtual Machine Placement Based on Euclidean Distance

  • Liu, Shukun;Jia, Weijia
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권7호
    • /
    • pp.2914-2935
    • /
    • 2016
  • With the increasing popularization of cloud computing, how to reduce physical energy consumption and increase resource utilization while maintaining system performance has become a research hotspot of virtual machine deployment in cloud platform. Although some related researches have been reported to solve this problem, most of them used the traditional heuristic algorithm based on greedy algorithm and only considered effect of single-dimensional resource (CPU or Memory) on energy consumption. With considerations to multi-dimensional resource utilization, this paper analyzed impact of multi-dimensional resources on energy consumption of cloud computation. A multi-dimensional resource constraint that could maintain normal system operation was proposed. Later, a novel virtual machine deployment method (NVMDM) based on improved particle swarm optimization (IPSO) and Euclidean distance was put forward. It deals with problems like how to generate the initial particle swarm through the improved first-fit algorithm based on resource constraint (IFFABRC), how to define measure standard of credibility of individual and global optimal solutions of particles by combining with Bayesian transform, and how to define fitness function of particle swarm according to the multi-dimensional resource constraint relationship. The proposed NVMDM was proved superior to existing heuristic algorithm in developing performances of physical machines. It could improve utilization of CPU, memory, disk and bandwidth effectively and control task execution time of users within the range of resource constraint.

콘빔 CT를 이용한 한국인의 하악 절치관 평가 (Assessment of mandibular incisive canal using cone-beam computed tomography in Korean population)

  • 조봉혜;정연화
    • 대한치과의사협회지
    • /
    • 제53권12호
    • /
    • pp.967-974
    • /
    • 2015
  • Purpose: This study was performed to investigate the characteristics of mandibular incisive canal (MIC) in Korean population. Materials and methods: A total of 97 subjects (60 males and 37 females) who underwent cone-beam computed tomography were included in the study. The anatomic features of MIC was assessed according to gender. Length, diameter and distance to inferior, lingual and buccal border were measured at the origin and the terminal. Also the distribution of MIC at each tooth position was evaluated. Results: Of 97 patients included, 75(77.3%) presented bilateral MIC and 13(13.4%) presented unilateral MIC. Of 194 hamimandibles, MIC was detected in 102(85%) sites in male and 61(82.4%) sites in female. Gender and side showed no statistically significant differences in detectability. The length, diameter and distance to adjacent structures were bigger in male than in female except the distance to lingual border. MIC travelled anteriorly in a slightly downward and lingual direction and usually terminated between the first premolar and the canine. On cross-sectional view, MIC showed individually scattered distribution both buccolingually and superoinferiorly. Conclusion: MIC is well detected with cone-beam computed tomography. Considered that the length and the location of MIC has large variations between individuals, its localization using cone-beam CT is highly recommended before performing surgical procedures such as implant placement and bone harvesting.

일반인 및 의료종사자들의 자동제세동기를 이용한 제세동에서 전극부착 위치에 관한 연구: 마네킨을 이용한 연구 (Automated external defibrillator electrode pad placement by the general public and health-care providers : A manikin study)

  • 박시은
    • 한국응급구조학회지
    • /
    • 제20권1호
    • /
    • pp.83-94
    • /
    • 2016
  • Purpose: This study aimed to assess defibrillator pad positioning by the general public and healthcare providers during basic life support (BLS) renewal education (RE). Methods: A total 130 subjects performed defibrillation using an automated external defibrillator (AED) equipped with electrode pads developed by the researchers and male resuscitation manikins, in order to assess electrode pad placement (EPP) before BLS RE. Subjects included 54 Healthcare providers (HP) and 76 members of the general public (GP). Results: The apex EPP was positioned in the risk area (RA), more than 5 cm distant from the area recommended, by 63.2% of the GP (n = 48). The apex EPP was positioned in the RA by 44.4% of the HP (n = 23). The distance from the apex (GP $5.27{\pm}2.21cm$, HP $4.18{\pm}1.71cm$) was statistically significant, using Student's t-test. Conclusion: For both GP and HP, apex EPP was significantly in error. Thus, to prevent defibrillation failures, EPP education and practice for GP and HP in all BLS education programs should be improved, and incorrect Korean cardiopulmonary resuscitation guidelines and related literature should be revised and corrected.

Ultrasound-guided Evacuation of Spontaneous Intracerebral Hemorrhage in Basal Ganglia

  • Park, Seong-Keun;Lee, Jung-Kil;Shin, Seung-Ryeol;Lee, Je-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권3호
    • /
    • pp.197-200
    • /
    • 2005
  • Objective: Ultrasound can be used in the treatment of large intracerebral hematoma. The authors present our experiences with Ultrasound-guided catheter placement for lysis and drainage of ganglionic hematoma, with emphasis on technical aspects. Methods: The authors applied real-time ultrasonography for the aspiration of intracerebral hematoma in 6cases. Ultrasound-guided aspiration via a burrhole was performed under local anesthesia. We selected a temporal entry point instead of the frequently used precoronal approach in ganglionic hematoma. A burrhole was made 4 to 6cm posterior from posterior border of frontal process of the zygomatic bone at the level of 4 to 5cm above the external auditory meatus. Results: In all patients, the catheter was placed accurately into the hematoma target. All patients were irrigated with urokinase once to three times a day. The catheter could be removed within two or three days. The mean hematoma volume was reduced from initially 32mL to 5mL in an average of two days. There were no intraoperative complications related to the use of real-time ultrasonography and no postoperative infections were noted. Conclusion: Ultrasound allows an easy and precise localization of the hematoma and the distance from the surface to the target can be calculated. Ultrasound-guided catheter placement for fibrinolysis and hematoma drainage is a simple and safe procedure.

농어촌소규모학교 통폐합에 따른 충북지역 기숙형중학교 사용자 만족도 조사 연구 (A Survey Study on the User's Satisfaction at the Boarding Middle School following the Merger and Abolition of Small Schools)

  • 이화룡;조창희;김진구
    • 교육시설 논문지
    • /
    • 제20권6호
    • /
    • pp.11-20
    • /
    • 2013
  • According to the decrease in birth rate and reduction of population, many schools in rural area have brought about the r decrease of number of student, and environment of education have became deteriorated. Accordingly, small schools be required improvement, and it should be altered placement of schools because it change number of student, distance and time of attending school, and formation of school zone are changed by alternating of human and physical environment. Merger and abolition of small schools are inevitable for change of placement standard to school and qualitative improvement of environment of education in rural area. This study researches the user's satisfaction at the boarding middle school following the merge and abolition of small schools in rural area. Finally, it reports the results of satisfaction research: the users are generally satisfied with education and student school life in the unified dormitory school.

특수교육기관 선택 요인 분석을 통한 특수교육대상자 배치계획 (Planning Plan for Special Education Subjects by Analyzing the Factor of Selecting Special Education Institutions)

  • 김은규;이용환
    • 교육녹색환경연구
    • /
    • 제17권3호
    • /
    • pp.17-25
    • /
    • 2018
  • 본 연구는 특수교육대상자 학부모가 자녀의 특수교육기관 선택 시 고려하고 있는 요인 등을 분석하여 특수교육대상자 배치계획에 대한 개선방안을 제시하는 것이며 연구결과는 다음과 같다. 첫째, 특수교육대상자는 유치원 과정이 의무교육임에도 상당수가 초등학교 입학 시 특수교육대상자로 선정되고 있다. 둘째, 특수교육대상자 학부모의 특수교육기관 선택 요인은 교사의 전문성과 교육과정 운영, 자녀의 장애 유형 및 정도, 통학거리 및 통학방법, 교육시설(특별활동실, 치료실 등)로 나타났다. 셋째, 특수교육대상자의 특수교육기관 배치 방식은 통학권내 학교 중 학부모 선택이 가장 많은 것으로 나타났다. 적정한 배치계획 수립을 위해서는 특수교육대상자 수가 정확히 파악되어야 하므로 특수교육대상자 선정 시기는 늦어도 유치원 과정으로 하고, 특수교육기관의 불균형 및 교육시설의 격차를 해소하기 위하여 통학권도 설정해야 할 것이다.

Cortical Bone Thickness for Mini-implant Placement in Korean

  • Kim, Kyu-Tag;Yu, Sun-Kyoung;Lee, Myoung-Hwa;Lee, Yun-Ho;Kim, Hye-Ryun;Kim, Heung-Joong
    • International Journal of Oral Biology
    • /
    • 제36권2호
    • /
    • pp.65-70
    • /
    • 2011
  • Recently, mini-implant is popular in the orthodontic treatment due to its simplicity and convenient surgical procedure. The objective of this study is to provide the anatomical guideline for mini-implant placement by analysing the cortical bone thickness in Korean. Hemi-sections of sixteen maxillae and twenty-two mandibles with normal teeth were used. Interdental areas between the 1st premolar and the 2nd premolar (Group 1), the 2nd premolar and the 1st molar (Gruop 2), and the 1st molar and the 2nd molar (Group 3) were sectioned and then scanned. After setting the axis of teeth, the cortical bone thickness was measured at the distance of 2 mm, 4mm, 6 mm, and 8 mm from alveolar crest. The mean thickness of cortical bone in the maxilla according to distance from alveolar crest was $1.30\;{\pm}\;0.63\; mm$ (2 mm), $1.49\;{\pm}\;0.62\; mm$ (4mm), $1.72\;{\pm}\;0.64\; mm$ (6mm), and $1.90\;{\pm}\;0.90\; mm$ (8 mm) at the buccal side and $1.33\;{\pm}\;0.47 \;mm$, $1.31\;{\pm}\;0.45\; mm$, $1.37\;{\pm}\;0.55\; mm$, and $1.39\;{\pm}\;0.58 \;mm$ at the palatal side. In the mandible, that was $3.14\;{\pm}\;1.71 \;mm$, $4.31\;{\pm}\;2.22 \;mm$, $4.23\;{\pm}\;1.94 \;mm$, and $4.30\;{\pm}\;1.57\; mm$ at the buccal side and $1.98\;{\pm}\;0.88 \;mm$, $2.79\;{\pm}\;1.01\; mm$, $3.35\;{\pm}\;1.27$ mm, and $3.93\;{\pm}\;1.38\; mm$ at the lingual side. The buccal cortical bone thickness in the maxilla was decreased from Group 1 to Group 3, while the thickness of palatal side was no change. In the mandible, it did not show a tendency at the buccal side and it was decreased from Group 1 to Group 3 without significant difference at the lingual side. Therefore, the buccal side of the Group 1 and Group 2 in both the maxilla and mandible seems to be the most appropriate site for a mini-implant placement with taking the stability and retention.