• Title/Summary/Keyword: Pitot Tube

Search Result 65, Processing Time 0.026 seconds

Effect of Circumferential Velocity from Guide Vane on the Nozzle Flow of a Jet Fan (제트팬 노즐내부 유동에 대한 고정익 출구 원주속도의 영향)

  • 최충현;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.209-216
    • /
    • 2001
  • A numerical study is peformed to investigate the effect of circumferential velocity generated by the guide vane on the nozzle flow of a jet fan, s a way of increasing the penetration force of jet fan with nozzle of 175mm diameter. For the validation of numerical results. the velocity is measured by a 5-hole pitot tube and flow visualization is conducted by the tuft method. Under the inlet condition that the maximum circumferential velocity in the stator outlet of the present jet fan is 1.8m/s, the axial velocity in the nozzle outlet has the feature that the velocity at the axis is low and the velocity near the wall high. Therefore, to increase the throw length of the jet fan, the configuration of the fairing and nozzle needs to be developed and the precise revise of the stator angle is required, In addition, the bigger the circumferential velocity, the smaller the axial velocity at the axis and the bigger non-uniformity of the flow distribution.

  • PDF

Experimental Study of the Non-Uniform Mean Flow at the Front of a Radiator in Engine Room (엔진룸내 방열기 전단면 유동 불균일도 측정에 관한 연구)

  • 류명석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.4
    • /
    • pp.72-79
    • /
    • 1996
  • The recent trend of higher output engines with more auxiliary parts is resulting in greater heat generation in the engine compartment. In order to maximize the heat dissipation and eliminate the inefficient flow in the engine compartment, it is necessary to understand the flow field under the hood. In this respect, experimental study as well as numerical analysis should be conducted. The automated measuring system was constructed to obtain three dimensional mean flow data with high accuracy. The measurements have been made on a vehicle with a steady incoming air flow. The result shows that there exists a high degree of non-uniformity in the mean flow velocity at the front of radiator.

  • PDF

A Study on The Velocity Distribution in Closed Conduit by Using The Entropy Concept (엔트로피 개념을 이용한 관수로내의 유속분포에 관한 연구)

  • Choo, Tai Ho;Ok, Chi Youl;Kim, Jin Won;Maeng, Seung Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4B
    • /
    • pp.357-363
    • /
    • 2009
  • When yields the mean velocity of the closed conduit which is used generally, it is available to use Darcy Weisbach Friction Loss Head equation. But, it is inconvenient very because Friction Loss coefficient f is the function of Reynolds Number and Relative roughness (${\varepsilon}$/d). So, it is demanded more convenient equation to estimate. In order to prove the reliability and an accuracy of Chiu's velocity equation from the research which sees hereupon, proved agreement very well about measured velocity measurement data by using Laser velocimeter which is a non-insertion velocity measuring equipment from the closed conduit (Laser Doppler Velocimeter: LDV) and an insertion velocity measuring equipment and the Pitot tube which is a supersonic flow meter (Transit-Time Flowmeters). By proving theoretical linear-relation between maximum velocity and mean velocity in laboratory flume without increase and decrease of discharge, the equilibrium state of velocity in the closed conduit which reachs to equilibrium state corresponding to entropy parameter M value has a trend maintaining consistently this state. If entropy M value which is representing one section is determinated, mean velocity can be gotten only by measuring the velocity in the point appearing the maximum velocity. So, it has been proved to estimate simply discharge and it indicates that this method can be a theoretical way, which is the most important in the future, when designing, managing and operating the closed conduit.

Experimental Study of Three-Dimensional Turbulent Flow in a $90^{\circ}C$ Rectanglar Cross Sectional Strongly Curved Duct (직사각형 단면을 갖는 $90^{\circ}C$ 급곡관 내의 3차원 난류유동에 관한 실험적 연구)

  • 맹주성;류명석;양시영;장용준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.262-273
    • /
    • 1991
  • In the present study, the steady, incompressible, isothermal, developing flow in a 90.deg. rectangular cross sectional strongly curved duct with aspect ratio 1:1.5 and Reynolds number of 9.4*10$^{4}$ has been investigated. Measurements of components of mean velocities, pressures, and corresponding components of the Reynolds stress tensor are obtained with a hot-wire anemometer and pitot tube. In general, flow in a curved duct is characterized by the secondary vortices which are driven mainly by centrifugal force-radial pressure gradient imbalance, and the stress field stabilizing effects near the convex wall and destablizing effects close to the concave wall. It was found that the secondary mean velocities attain values up to 39% of the bulk velocity and are largely responsible for the convections of Reynolds stress in the cross stream plane. Therefor upstream of the bend the Reynolds stress are low. Corresponding to the small boundary layer thickness. At successive planes, large values of Reynolds stress were observed near the concave surface and the side wall.

An Experimental Study on the Effects of Concentration Gradient and Mean Velocity on the Liftoff Characteristics of the Triple Flame (농도구배와 평균속도가 삼지화염의 부상 특성에 미치는 영향에 관한 실험적 연구)

  • Seo, Jeong-Il;Kim, Nam-Il;Oh, Kwang-Chul;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1061-1070
    • /
    • 2003
  • A triple flame in a mixing layer was studied experimentally with concentration gradient and mean velocity by using a multi-slot burner, which can stabilize the lift-off flame. Flame stabilization condition, lift-off heights, and some other characteristics were examined for methane and propane flame within a range of very low concentration gradient. Pitot-tube and LDV(Laser Doppler Velocimetry) were used for velocity. Mass spectroscopy and Rayleigh scattering signal were used for concentration gradients. Thermo-couples and SiC TFP(Thin Filament Pyrometer) were used for temperature. It was found that minimum values of the lift-off heights exist at a certain concentration gradient for constant mean velocity and this means that the propagation velocity has a maximum value. The scales of flame to the burner nozzle and intensity variation of the diffusion flame were suspected as the cause.

A study on flow around a passenger vehicle model (승용차 모형주위의 유동에 관한 연구)

  • 장성원;유정열;이택식
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.53-62
    • /
    • 1990
  • A wind tunnel experiment for the flow around a 1/5 scale passenger vehicle model has been carried out. A 5-hole Pitot tube is used for measuring velocity distributions around the model and a scanivalve with 48 ports is used for measuring surface pressure distribution at various Reynolds numbers. In order to observe the flow on the surface and in the wake region, a flow visualization experiment has been performed using wool tuft with and without paper cones. In addition, a 2-dimensional viscous calculation considering only the mid-plane section of the model has been performed. A complex wake structure in the immediate rear of the model has been confirmed. The distributions of the surface pressure coefficient are not sensitively dependent on the Reynolds Number. In the first half of the model, they do not seem to vary form section to section. However, in the second half, they do vary from section to section, especially at the bottom surface, which indicates that the cross flow vortex is more affected by the bottom surface than the top surface. The qualitative agreement of the measured and calculated velocity field also explains the usefulness of the 2-dimensional calculation in the limited sense.

  • PDF

A Study on The Measurement of Vibration Characteristics by Iteration of The Rotor Blade and The Front Vortex (로터 블레이드와 전방와류의 상호작용에 의한 진동특성 측정에 관한 연구)

  • Lee, Myoung-Ok;Choi, Jong-Soo;Rhee, Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.170-175
    • /
    • 2005
  • The focus of this paper is to observe the aerodynamic and vibration characteristics of the NACA0012 blade(AR=16.6) fixed on the lower surface of the wind tunnel, by changing air speed and the blade's angle of attack. After fixing a slit-typed vortex generator on the front of the blade, it could be observed that the vibrational characteristics caused by interactions between vortex and blade through the 5-hole pilot tubes. And, also, two different blades in stiffness had been prepared for observing those characteristics above in this experiment. The results were compared with the given stiffness of blade, as well. According to the results, it is clear to recognize that the vibration spectrum increases while air speed and angle of attack increase, and, also, less stiffness means bigger vibration spectrum.

  • PDF

Development and Validations of Air Data System using MEMS Sensor for High-Performance UAV (MEMS 압력센서를 이용한 고성능 무인항공기용 공력자료시스템의 개발과 검증)

  • Baek, Un-Ryul;Kim, Sung-Su;Kim, Sung-Hwan;Park, Choon-Bae;Choi, Kee-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.10
    • /
    • pp.1017-1025
    • /
    • 2008
  • The air data system(ADS) was developed for unmanned aerial vehicle(UAV) in this paper. Generally, the ADS helps flight control computer(FCC) to control the UAV above the stall speed and to hold the given altitude. The accurate measurement of airspeed and altitude of UAV is important because it indicates a flight performance and assures a safe flight. The ADS consists of MEMS pressure sensors, a lowpass filter, a micro controller unit and a pitot-tube. The ADS errors were reduced by pressure and temperature compensation of MEMS sensors. Finally, the altitude and airspeed data of the ADS was compared with GPS data in the flight test.

An Experimental Study on the Flow Characteristics of Axial Flow Fan with Centrifugal Sub-Blade (원심형 보조날개를 부착한 축류홴의 유동특성에 관한 실험적 연구)

  • Lee, Sukjong;Sung, Jaeyong;Lee, Myeong-Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.3
    • /
    • pp.19-25
    • /
    • 2013
  • A new type axial flow fan with centrifugal sub-blades has been designed and fabricated in the present study. We investigated velocity and pressure distributions in downstream flow fields of the fan experimentally to detect the detailed flow characteristics of new axial flow fan and an existing axial flow fan. Two-dimensional velocity components were probed by applying a particle image velocimetry system and pressure distributions were measured by Pitot tube and micro-manometer. Our results show that the velocity and pressure distributions at the flow fields of the new fan are quite different from the existing fan, and that the centrifugal sub-blades in the new fan can improve the performance characteristics in view of kinetic energy.

Investigation on the Effective Calibration of Annubar (다점식 피토관의 효율적인 교정에 대한 연구)

  • Choi Yong-Moon;Choi Hae-Man;Choi Ji-Chul;Hong Kyung-Ki;Han Sang-Woo;Kim Woong-Sun;Chun Se-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.373-380
    • /
    • 2006
  • Annubar is one of popular tools to measure the exhausted gas flow rate from the stacks. For the accurate monitoring of the amount of discharged pollutants, calibration of annubar is very important. Calibration of annubar has been carried out in a wind tunnel. When the length of annubar is longer than the test section size of wind tunnel, it is very difficult to find out typical value of annubar coefficients. So, a measurement technique to calibrate annubar longer than the size of the test section of wind tunnel must be developed. In the present study, an experiment is performed to measure the annubar coefficients in such a limited size of the wind tunnel. The experimental annubar coefficient by using a partial blocking technique is very close to the annubar coefficient of normal condition.