• Title/Summary/Keyword: Pitot Pressure

Search Result 70, Processing Time 0.025 seconds

Study on Flight Test Practice of the Small Civil Airplane Development for Pitot-Static System's Error Identification (소형 항공기 개발 동정압계통 오차 확인 비행시험 사례)

  • Kim, Chanjo;Seo, Jihan;Lee, Wonjoong
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.3
    • /
    • pp.33-38
    • /
    • 2013
  • The air data measured from the static pressure, the dynamic pressure and etc. of an airplane is used for calculation of many flight parameters(altitude and airspeed and so on) and these values applied to flight safety and navigation flight. The pitot-static system of the development airplane is calibrated by finding of pitot-static system's error using tower fly-by, trailing cone method and etc. This paper is describing for the introduction of the trailing cone method and major items for test planning, preparation, operation and results for air data calibration flight test performed, considering efficiency and safety during KC-100 development project.

Design of Pitot-Tube Configuration Using CFD Analysis and Optimization Techniques (CFD 해석 및 최적화 기법을 이용한 피토관 형상설계)

  • Kim, Do-Jun;Cheon, Young-Seong;Myong, Rho-Shin;Park, Chan-Woo;Cho, Tae-Hwan;Park, Young-Min;Choi, In-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.5
    • /
    • pp.392-399
    • /
    • 2008
  • Accurate measurement of speed and altitude of flying vehicles in air data system remains a critical technical issue. A highly reliable Pitot-static probe is required to obtain air data such as total pressure and static pressure. In this study, an analysis of the characteristics of flowfield around the Pitot-static probe was performed by using a Navier-Stokes CFD code. In addition, for the purpose of finding an optimal configuration, a technique based on the response surface method is applied to the problem with design parameters including shape of the nose section and cone angle. It is shown that the optimal configuration fulfills the MIL specification in wider range of high angles of attack.

Comparison of Thrust Measurement of a Supersonic Wind Tunnel (초음속 풍동의 추력 측정 방법 비교)

  • Heo, Hwan Il;Kim, Hyeong Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.93-99
    • /
    • 2003
  • The determination of thrust is essential in design and evaluation of a hypersonic airbreathing propulsion device. Conventional methods to determine the thrust is using thrust stand or force measurement system. However, these conventional methos are not applicable to the case where thrusts stands are impractical, such as free jet testing of engines, and model combustor. For this reason, the thrust determination method from measured pitot pressure is considered and validated. Validation of thrust determination from pitot pressures can be achieved by comparing the actual thrust from thrust stand. For validation purpose, a small-scale supersonic wind tunnel is installed on the thrust stand. Thrusts are measured while pressures are measured simulaneously. Then, the thrust from pitot pressure measurements are compared with the measured thrust and theoretical thrusts.

Study on Static Pressure Error Model for Pressure Altitude Correction (기압 고도의 정밀도 향상을 위한 정압 오차 모델에 관한 연구)

  • Jung, Suk-Young;Ahn, Chang-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.47-56
    • /
    • 2005
  • In GPS/INS/barometer navigation system for UAV, vertical channel damping loop was introduced to suppress divergence of the vertical axis error of INS, which could be reduced to the level of accuracy of pressure altitude measured by a pitot-static tube. Because static pressure measured by the pitot-static tube depends on the speed and attitude of the vehicle, static pressure error models, based on aerodynamic data from wind tunnel test, CFD analysis, and flight test, were applied to reduce the error of pressure altitude. Through flight tests and sensitivity analyses, the error model using the ratio of differential pressure and static pressure turned out to be superior to the model using only differential pressure, especially in case of high altitude flight. Both models were proposed to compensate the effect of vehicle speed change and used differential and static pressure which could be obtained directly from the output of pressure transducer.

Effects of Slot Configurations on the Passive Control of Oblique-Shock-Interaction Flows (슬롯 형상이 경사충격파 간섭유동의 피동제어에 미치는 영향에 관한 연구)

  • Jang, Seong-Ha;Lee, Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.12
    • /
    • pp.18-24
    • /
    • 2006
  • Passive control of the shock wave/turbulent boundary-layer interaction utilizing slotted plates and a porous plate over a cavity has been carried out. Effect of various slot configurations on the characteristics of the interaction has been observed. Pitot/wall surface pressure distributions and flow visualizations including Schlieren images, kerosene-lampblack tracings and interference fringe patterns over a thin oil-film have been obtained at the downstream of the shock interactions. For the streamwise-slot configuration, a local higher pitot pressure was noticed at the downstream of the interaction as compared with the case of no control, however, not much improvement in pitot pressure was observed for the spanwise-slot configuration.

An Experimental Study on Energy Losses in Steam Turbine Cascade Flow (증기터빈 익렬유동의 에너지손실에 관한 실험적 연구)

  • ;;Ahn, Hyung-Joon;Lee, Kwon-Hee
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.3022-3030
    • /
    • 1995
  • The irreversibility of condensation process in the supersonic flow of steam turbine cascade causes the entropy to increase and the total pressure loss to be generated. In the present study, in order to investigate the moist air flow in two dimensional steam turbine cascade made as the configuration of the last stage tip section of the actual steam turbine moving blade, the static and total pressures along suction side of the blade are measured by pressure taps and Pitot tube. The flow field is visualized by a Schlieren system. The effects of stagnation temperature and the degree of supersaturation on energy loss and entropy change in the flow are clearly identified.

A CFD ANALYSIS OF THE FLOWFIELD OF A HELICOPTER IN FORWARD MOTION FOR THE STUDY OF PITOT-TUBE FOR INSTALLATION LOCATION (피토튜브 장착위치 선정을 위한 전진 비행하는 헬리콥터 유동장의 CFD 분석)

  • Cho, H.G.;Kang, Y.J.;Kim, S.H.;Myong, R.S.;Cho, T.H.;Park, Y.M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.256-261
    • /
    • 2008
  • A CFD analysis of helicopter flowfield in forward flight is considered as non-trivial issue because of the complexity of vorticity-dominated flowfield. In this work, a study on the selection of the proper location for the installation of the Pitot probe is conducted using a CFD code which can deal with the interaction of rotor blade vortex and body. To describe the flow patterns for rotating rotor blades and body, the sliding mesh scheme is utilized. Pressure distributions and flow patterns are also analyzed to identify regions free from the interaction of body and wake induced from rotor blades.

  • PDF

A CFD ANALYSIS OF THE FLOWFIELD OF A HELICOPTER IN FORWARD MOTION FOR THE STUDY OF PITOT-TUBE FOR INSTALLATION LOCATION (피토튜브 장착위치 선정을 위한 전진 비행하는 헬리콥터 유동장의 CFD 분석)

  • Cho, H.G.;Kang, Y.J.;Kim, S.H.;Myong, R.S.;Cho, T.H.;Park, Y.M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.256-261
    • /
    • 2008
  • A CFD analysis of helicopter flowfield in forward flight is considered as non-trivial issue because of the complexity of vorticity-dominated flowfield. In this work, a study on the selection of the proper location for the installation of the Pitot probe is conducted using a CFD code which can deal with the interaction of rotor blade vortex and body. To describe the flow patterns for rotating rotor blades and body, the sliding mesh scheme is utilized. Pressure distributions and flow patterns are also analyzed to identify regions free from the interaction of body and wake induced from rotor blades.

  • PDF

A Study on the Characteristics of Multi-point Pilot Tube Flow-meter (다점 피토관 유량계의 특성에 관한 연구)

  • 임재명;윤복현;박경암
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.2 s.11
    • /
    • pp.35-43
    • /
    • 2001
  • The flow characteristics passing a multi-point Pitot tube flow-meter of diamond shape and the characteristics of flow coefficients of the flow-meter are experimentally studied by varying combination of upstream rectangular dual elbows. The results provide the flow coefficients, which show good stability and reliability within the Reynolds number range coveted here in this study, and which can be used to measure flow-rates in practice. The variation of dual elbows upstream can change the velocity field so much that the flow pattern might thwart the precise flow measurement using the multi-point Pitot tube. The strongest swirl is detected in the case of $90^{\circ}$ dual elbow combination of all. In addition, it is observed that flow separation remains unchanged and occurs at the same point irrespective of various upstream dual elbow combinations.

  • PDF

Uncertainty Assessment of Gas Flow Measurement Using Multi-Point Pitot Tubes (다점 피토관을 이용한 기체 유량 측정의 불확도 평가)

  • Yang, Inyoung;Lee, Bo-Hwa
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.5-10
    • /
    • 2016
  • Gas flow measurement in a closed duct was performed using multi-point Pitot tubes. Measurement uncertainty was assessed for this measurement method. The method was applied for the measurement of air flow into a gas turbine engine in an altitude engine test facility. 46 Pitot tubes, 15 total temperature Kiel probes and 9 static pressure tabs were installed in the engine inlet duct of inner diameter of 264 mm. Five tests were done in an airflow range of 2~10 kg/s. The flow was compressible and the Reynolds numbers were between 450,000 and 2,220,000. The measurement uncertainty was the highest as 6.1% for the lowest flow rate, and lowest as 0.8% for the highest flow rate. This is because the difference between the total and static pressures, which is also related to the flow velocity, becomes almost zero for low flow rate cases. It was found that this measurement method can be used only when the flow velocity is relatively high, e.g., 50 m/s. Static pressure was the most influencing parameter on the flow rate measurement uncertainty. Temperature measurement uncertainty was not very important. Measurement of boundary layer was found to be important for this type of flow rate measurement method. But measurement of flow non-uniformity was not very important provided that the non-uniformity has random behavior in the duct.