• 제목/요약/키워드: Pitch ratio

검색결과 527건 처리시간 0.023초

Investigation of Seakeeping Performance of Trawler by the Influence of the Principal Particulars of Ships in the Bering Sea

  • Thi Thanh Diep Nguyen;Hoang Thien Vu;Aeri Cho;Hyeon Kyu Yoon
    • 한국해양공학회지
    • /
    • 제38권2호
    • /
    • pp.43-52
    • /
    • 2024
  • Investigating ship motion under real conditions is vital for evaluating the seakeeping performance, particularly in the design process stage. This study examined the influence of the principal particulars of a trawler on its seakeeping performance. The wave conditions in the Bering Sea are investigated using available data. The length-to-beam (L/B) and beam-to-draft (B/T) ratios of the ship are changed by 10% for the numerical simulation. The response amplitude operator (RAO) motion, root mean square (RMS) value and sensitivity analysis are calculated to evaluate the influence of the trawler dimensions on ship motions. The peak RAO motion affected the ship motions noticeably because of the resonance at the natural frequency. The L/B and B/T ratios are important geometric parameters of a ship that significantly influence its RMS motion, particularly in the case of roll and pitch. The change in the B/T ratio has a good seakeeping performance based on a comparison of the roll and pitch with the seakeeping criteria. The present results provide insights into the seakeeping performance of ships due to the influence of the principal dimensions in the design stage.

머신러닝을 활용한 코다이 학습장치의 인식률 변화 (Changes in the Recognition Rate of Kodály Learning Devices using Machine Learning)

  • YunJeong LEE;Min-Soo KANG;Dong Kun CHUNG
    • Journal of Korea Artificial Intelligence Association
    • /
    • 제2권1호
    • /
    • pp.25-30
    • /
    • 2024
  • Kodály hand signs are symbols that intuitively represent pitch and note names based on the shape and height of the hand. They are an excellent tool that can be easily expressed using the human body, making them highly engaging for children who are new to music. Traditional hand signs help beginners easily understand pitch and significantly aid in music learning and performance. However, Kodály hand signs have distinctive features, such as the ability to indicate key changes or chords using both hands and to clearly represent accidentals. These features enable the effective use of Kodály hand signs. In this paper, we aim to investigate the changes in recognition rates according to the complexity of scales by creating a device for learning Kodály hand signs, teaching simple Do-Re-Mi scales, and then gradually increasing the complexity of the scales and teaching complex scales and children's songs (such as "May Had A Little Lamb"). The learning device utilizes accelerometer and bending sensors. The accelerometer detects the tilt of the hand, while the bending sensor detects the degree of bending in the fingers. The utilized accelerometer is a 6-axis accelerometer that can also measure angular velocity, ensuring accurate data collection. The learning and performance evaluation of the Kodály learning device were conducted using Python.

초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 요철이 설치된 유출면에서의 열/물질전달 특성 (Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow)

  • 이동호;남용우;조형희
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.338-348
    • /
    • 2004
  • The present study is conducted to investigate the effect of rib arrangements on an impingement/effusion cooling system with initial crossflow. To simulate the impingement/effusion cooling system, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of tile hole diameter. Initial crossflow passes between the injection and effusion plates, and the square ribs (3mm) are installed on the effusion plate. Both the injection and effusion hole diameters are 10mmand Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effects of rib arrangements, various rib arrangements, such as 90$^{\circ}$transverse and 45$^{\circ}$angled rib arrangements, are used. Also, the effects of flow rate ratio of crossflow to impinging jets are investigated. With the initial crossflow, locally low transfer regions are formed because the wall jets are swept away, and level of heat transfer rate get decreased with increasing flow rate of crossflow. When the ribs are installed on the effusion plate, the local distributions of heat/mass transfer coefficients around the effusion holes are changed. The local heat/mass transfer around the stagnation regions and the effusion holes are affected by the rib positions, angle of attack and rib spacing. For low blowing ratio, the ribs have adverse effects on heat/mass transfer, but for higher blowing ratios, higher and more uniform heat transfer coefficient distributions are obtained than the case without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. Average heat transfer coefficients with rib turbulators are approximately 10% higher than that without ribs, and the higher values are obtained with small pitch of ribs. However, the attack angle of the rib has little influence on the average heat/mass transfer.

무지 외반증에 동반된 중족 설상 관절염의 방사선학적 특징과 수술적 치료 결과 (Radiographic Characteristics and the Clinical Results of the Operative Treatment of the Tarsometatarsal Osteoarthritis with Hallux Valgus Deformity)

  • 최홍준
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.121-129
    • /
    • 2013
  • Purpose: To evaluate the radiographic characteristics of the tarsometatarsal osteoarthritis with hallux valgus deformity and report the clinical results of the operative treatment. Materials and Methods: This is a retrospective study of 20 patients, 22 feet who had been operated for non-traumatic tarsometatarsal osteoarthritis with hallux valgus (TMT group) and control group of hallux valgus patients without tarsometatarsal osteoarthritis (26 patients, 28 feet) from April 2004 to July 2011. Radiographic characteristics were compared between the groups, using hallux valgus angle, $1^{st}-2^{nd}$ intermetatarsal angle, metatarsal length ratio, metatarsus adductus angle, talonavicular coverage angle, talus-$1^{st}$ metatarsal angle, calcaneal pitch angle and medial cuneiform height. Pre- and postoperative difference of $1^{st}-2^{nd}$ metatarsal declination angle and distance between the $1^{st}-2^{nd}$ metatarsal head were evaluated. The clinical results were evaluated by American Orthopaedics Foot and Ankle Society (AOFAS) midfoot scale and visual analogue scale (VAS). Results: Metatarsal length ratio was significantly larger in TMT group (p<0.001). Metatarsus adductus angle, talonavicular coverage angle, talus-$1^{st}$ metatarsal angle on lateral radiograph, calcaneal pitch angle and medial cuneiform height were different from control group (p<0.001, p<0.001, p=0.001, p=0.010, p=0.006). Postoperative declination of the $2^{nd}$ metatarsal and distance between the $1^{st}-2^{nd}$ metatarsal head were increased (p=0.009, p=0.001). The AOFAS and VAS score were improved (p<0.001, p<0.001). Conclusion: Non-traumatic osteoarthritis of the tarsometatarsal joints seems to be associated with long 2nd metatarsal length, metatarsus adductus and flatfoot deformity. Spur excision may be successful to relieve symptoms when the arthritis was diagnosed in early stage.

추력과 효율 향상을 위한 AUV Double Hydrofoil의 모션 최적설계 (MOTION DESIGN OPTIMIZATION OF AUV DOUBLE HYDROFOIL FOR IMPROVEMENT OF THRUST AND EFFICIENCY)

  • 소현규;조태현;이용한;김진산;한준희;구본찬;이도형
    • 한국전산유체공학회지
    • /
    • 제21권1호
    • /
    • pp.78-85
    • /
    • 2016
  • While most AUV researches have concerned about single hydrofoil, practical AUV's are generally operated with multiple hydrofoils. Double hydrofoil study attempts to evaluate thrust and efficiency with various flapping motions, and carries out design optimization using parametric analysis. Flow patterns such as vortex shedding and wake-body interaction are carefully investigated during design variable sensitivity analysis. The purpose of this design optimization is to find out the optimal motion that yields maximum thrust and efficiency. The design optimization employes several techniques such as table of orthogonal arrays, Kriging method, ANOVA analysis and MGA. Throughout this research, it is possible to find the optimal values of heaving ratio, heaving shift and pitch shift: Heaving ratio 0.950, heaving shift $23.120^{\circ}$ and pitch shift $89.991^{\circ}$ are found to be optimal values in double hydrofoil motions. Thrust and efficiency are 16.7% and 35.1% higher than existing AUV that did not consider nonlinear dependency of motion parameters. This results may offer an effective framework that is applicable to various AUV motion analyses and designs.

레이저 스펙클과 1차원 CCD소자를 이용한 물체의 미소변위측정에 관한 연구 (Measurement of Micro-displacement of an Object by Laser Speckle using Linear Array CCD Detection System)

  • 우창헌;민동현;김수용
    • 한국광학회지
    • /
    • 제5권1호
    • /
    • pp.138-143
    • /
    • 1994
  • 거친 표면을 가진 물체의 미소변위를 1차원 CCD소자와 레이저 스펙클(laser speckle) 방법을 이용하여 측정하였다. 거친 표면에서 산란된 레이저 광이 이루는 스펙클 무늬를 물체의 이동 전후에 얻고, 그것의 상호상관함수(cross-correlation)를 계산하여 스펙클 변위를 계산한다. 1차원 CCD소자를 이용하여 물체이동 전후의 스펙클 무늬를 측정하고, 레이저 스펙클 변위값을 386 PC로 인터페이스하여 PC에서 계산한다. 사용한 CCD 소자의 화소 간격은 $15\mu\textrm{m}$이고, 화소의 개수는 1728개이다. 스펙클 변위와 물체의 이동거리와는 비는 레이저 빔의 파면의 곡률에따라 1.03으로부터 5.20까지 변화한다. CCD 픽셀의 간격이 $15\mu\textrm{m}$이므로 물체의 $3\mu\textrm{m}$ 이동을 감지해 낼 수 있다.

  • PDF

멀티 펄스에 의한 선형 예측 필터링과 적응 임계값을 갖는 LRT의 연구 (A Study on A Multi-Pulse Linear Predictive Filtering And Likelihood Ratio Test with Adaptive Threshold)

  • 이기용;이주헌;송익호;안수길
    • 한국음향학회지
    • /
    • 제10권1호
    • /
    • pp.20-29
    • /
    • 1991
  • 기존의 선형 예측법에 의한 음성 분석의 기본적인 가정은 전극점 성도 필터의 입력은 백색 신호라는 것이다. 그러나, 주기성 입력 신호의 경우 피치 바이오스 오차가 기존 선형 예측 계수에 개입된다. 만일 여기 신호의 추정값을 이용할 수 있다면 멀티 펄스에 의한 선형 예측 분석으로 이러한 바이어스를 제거할 수 있다. 기존의 선형 예측 분석에서의 예측 오차는 멀티 펄스 여기 신호열과 불규칙 잡음 신호열의합으로 나타내어질 수 있으므로 선형 예측 오차로부터 멀티 펄스 신호열을 찾아내는 것은 고전적인 검출 및 추정의 문제로 생각될 수 있다. 본 논문에서는 먼저 LRT 를 이용하여 예측오차로부터 멀티 펄스 신호의 위치와 크기를 찾아낸 다음 이 신호열로부터 피치 바이어스가 제거된 선형 예측 계수를 구하는 알고리즘을 제안한다. 매번 적응된 임계값을 적용하여 반복 수행을 함으로써 성능향상을 입증하였다.

  • PDF

족부측방촬영을 통한 정상 아동의 족근골 및 중족골간 각도 계측 결과 (Measurements on Radiographs of the Foot in Normal Children)

  • 고철언;조현오;곽경덕;김병용;손수민;문진경;오필환
    • 대한족부족관절학회지
    • /
    • 제1권2호
    • /
    • pp.75-80
    • /
    • 1997
  • 정상 아동 124명에서 족부 단순방사선촬영 소견에서 편평족과 관련하여 방사선학적 계측치를 나이에 따라 비교한 결과 나이가 어릴수록 대부분이 편평족 소견을 보였고 나이가 많아짐에 따가 차츰 발아치가 형성되어 13세 이후에는 대부분의 예에서 성인과 비슷한 소견을 보였다. 따라서 아동에서는 방사선학적 계측에서 편평족 소견을 보이더라도 이를 치료할 필요가 있을지 결정하는데는 임상 소견이 더 중요할 것으로 사료된다. 본 연구는 정상아동에 대한 횡적 조사연구이므로 향후 종적 조사를 시행하면 나이에 따른 발아치의 변화를 좀 더 정확하게 파악할 수 있을 것으로 사료된다.

  • PDF

족근동 증후군으로 오인된 Accessory Anterolateral Talar Facet에 의한 거종관절 충돌 (Accessory Talar Facet Impingement due to Accessory Anterolateral Talar Facet Misdiagnosed as Sinus Tarsi Syndrome)

  • 박재우;박철현
    • 대한족부족관절학회지
    • /
    • 제22권1호
    • /
    • pp.16-20
    • /
    • 2018
  • Purpose: To evaluate the clinical and radiographic results of surgical treatment for patients with sinus tarsi pain due to accessory talar facet impingement. Materials and Methods: Between July 2013 and July 2015, nine patients who underwent surgery for the accessory talar facet impingement were reviewed. The mean follow-up period was 18.6 months (12~36 months), and the mean age was 33.1 years (19~60 years). Previous trauma history, duration of symptom, and types of surgery were analyzed. The clinical results were evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score and visual analogue scale (VAS). Radiographic results were assessed using Meary's angle, calcaneal pitch angle, heel alignment angle, and heel alignment ratio. Results: All patients had evident trauma history prior to the initial symptom. The mean duration of symptoms was 25.6 months (6~120 months). Four patients received only accessory anterolateral talar facet (AALTF) excision, and four patients received medial sliding calcaneal osteotomy (MSCO). One patient underwent both AALTF excision and MSCO. The AOFAS ankle-hindfoot score was significantly improved from 73 (62~77) preoperatively to 93 (67~100) postoperatively. The VAS score was decreased from 6 (5~7) preoperatively to 1 (0~5) postoperatively. The Meary's angle and calcaneal pitch angle showed no significant difference after surgery. The heel alignment angle and ratio increased from $-3.6^{\circ}$ ($-10^{\circ}{\sim}5^{\circ}$) and 0.22 (-0.15~0.6) preoperatively to $2.8^{\circ}$ ($1^{\circ}{\sim}5^{\circ}$) and 0.42 (0.3~0.6) postoperatively, respectively. Conclusion: If there is persistent sinus tarsi pain in patients with hindfoot valgus, accessory talar facet impingement caused by AALTF could be considered as a cause of chronic sinus tarsi pain.

Heat Transfer and Frictions in the Rectangular Divergent Channel with Ribs on One Wall

  • Lee, MyungSung;Ahn, SooWhan
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권3호
    • /
    • pp.352-357
    • /
    • 2016
  • An investigation of ribbed divergent channel was undertaken to determine the effect of rib pitch to height ratio on total friction factor and heat transfer results in the fully developed regime. The ribbed divergent rectangular channel with the channel exit hydraulic diameter ($D_{ho}$) to inlet channel hydraulic diameter ($D_{hi}$) ratio of 1.16 with wall inclination angle of 0.72 deg, at which the ratios (p/e) of 6,10, and 14 are considered. The ribbed straight channel of $D_{ho}/D_{hi}=1.0$ were also used. The ribbed divergent wall is manufactured with a fixed rib height (e) of 10 mm and the ratio of rib spacing (p) to height 6, 10, and 14. The measurement was run with range of Reynolds numbers from 24,000 to 84,000. The comparison shows that the ratio of p/e=6 has the greatest thermal performance in the divergent channel under two constraints; identical mass flow rate and identical pressure drop.