• 제목/요약/키워드: Piston cooling

검색결과 75건 처리시간 0.022초

Sensorless Control for a PM Synchronous Motor in a Single Piston Rotary Compressor

  • Cho Kwan-Yuhl
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.29-37
    • /
    • 2006
  • A sensorless control for an IPM (Interior Permanent Magnet) synchronous motor in a single piston rotary compressor is presented in this study. The rotor position is estimated from the d-axis and q-axis current errors between the real system and a motor model of the position estimator. The torque pulsation of the single piston rotary compressor is compensated to reduce speed ripples, as well as, mechanical noise and vibration. The proposed sensorless drive enables the compressor to operate at a lower speed which increases energy savings and reduces mechanical noise. It also gives high speed operations by a flux weakening control for rapid air-cooling and heating of the heat pump air-conditioners.

적외선 센서 냉각용 스터링 냉동기의 수명/신뢰성 시험 (Reliability Test of the Stirling Cryocooler for cooling infrared detector)

  • 박성제;홍용주;김효봉;유병건;이기백
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.156-159
    • /
    • 2003
  • A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stirling cryocooler is designed, manufactured and fabricated, and performance characteristics are investigated. This cooler delivers approximately 0.5W cooling at 77K for 30W ∼ 40W of input power from AC power supply. And, after the climate performance and reliability for the cryocooler is discussed, operating test without cooling load at the cold end is performed.

  • PDF

Split tube 길이변화에 따른 스터링 극저온 냉동기의 특성에 관한 연구 (Study of Stirling Cryocooler Performance with different length of split tube)

  • 홍용주;박성제;고득용;김효봉;오군섭;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.37-40
    • /
    • 2001
  • A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at Korea Institute of Machinery & Materials. In this study, performance tests of stirling cryocooler with different length of split tube were performed to get characteristics of cryocooler. The Experimental results show the Stirling cryocooler with small volume of split tube has higher cooling power and faster response time.

  • PDF

관성관 맥동관 극저온 냉동기의 유동 특성 모델링 (MODELING ON FLOW CHARACTERISTICS OF INERTANCE PULSE TUBE CRYOCOOLER)

  • 한성현;이경환;최종욱;김재수
    • 한국전산유체공학회지
    • /
    • 제19권3호
    • /
    • pp.14-19
    • /
    • 2014
  • The flow characteristics of inertance pulse tube cryocooler(IPTC) was investigated with a computational thermal fluid dynamics for the reciprocating flow in IPTC including the piston movement of linear compressor. Two dimensional axisymmetric modeling was applied for the flow in an IPTC with a clearance between the piston and cylinder wall of linear compressor. The pressure, velocity, and temperature distribution were examined for the steady state. These were compared with previous results to confirm the validity in the modeling and computational results. The leakage between piston and cylinder wall affect the cooling capacity seriously. The dependence on mesh numbers were also examined to obtain a proper mesh numbers to improve the accuracy of calculation, which showed significant effect on the results. The user-defined function was used for the process of compression and expansion of piston.

전류제어 루프를 갖는 선형 압축기 스트로크 제어기의 동적 성능 향상에 관한 연구 (A Study of the Dynamic Performance Improvement of a Linear Compressor Stroke Controller with a Current Control Loop)

  • 오준태;김규식
    • 전자공학회논문지
    • /
    • 제50권8호
    • /
    • pp.274-282
    • /
    • 2013
  • 본 논문에서는 위상지연필터를 이용한 전류제어 루프를 갖는 선형압축기의 스트로크 제어기를 구현하였다. 선형압축기가 적용된 냉장고나 에어컨의 냉각능력을 제어하기 위해서는 단위시간동안 피스톤의 움직인 거리, 즉 피스톤의 속도를 제어해야 하는데 이때 리니어 모터의 주파수나 스트로크를 조정함으로써 가능하다. 이때, 주파수를 고정하고 스트로크를 변화시키는 것이 일반적이다. 인가된 전류를 정밀하게 제어하는 것이 선형압축기의 동특성을 좌우하는데, 본 연구에서는 전류제어 루프를 갖는 피스톤 진폭 제어기를 제안하고 성능이 우수함을 모의실험을 통해 확인하였다.

열상장비용 스터링 극저온 냉동기 특성평가 (I) : 성능시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (II) : Performance test)

  • 박성제;홍용주;김효봉;김양훈;이성래;이기백;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.320-323
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the cooling capacity / applied input power and cool down time are investigated. This cooler delivers approximately 0.9W cooling at 80K for 30W ~ 40W of input power. And, It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$.

  • PDF

일체형 로타리 압축기-베인 팽창기 (A Combined Rotary Compressor-vane Expander)

  • 김현진;노영재;김용희
    • 한국유체기계학회 논문집
    • /
    • 제18권3호
    • /
    • pp.12-19
    • /
    • 2015
  • As a means of improving cycle performance of a R410A air-conditioning system, a combined structure of compressor and expander was introduced. A vane rotary type expander was designed to share a common shaft with twin type rolling piston rotary compressor in a housing. Numerical simulation on the performance of the combined compressor and expander was carried out. At ARI condition, the volumetric and total efficiencies of the designed vane expander were 69.37% and 30.23%, respectively. With the application of this expander, the compressor input was reduced by 3.91%, and the cooling capacity was increased by 3.98%. As a result, COP of the air-conditioning system was improved by 8.2%. As the pressure difference between the condenser and the evaporator becomes large, COP improvement increases unless the mass flow rate in the expander exceeds that in the compressor.

내연기관 실린더 헤드 조립체 내부의 냉각수 유동 및 열전달에 관한 연구 (NUMERICAL STUDY ON THE COOLANT FLOW AND HEAT TRANSFER IN THE CYLINDER HEAD ASSEMBLY OF AN INTERNAL COMBUSTION ENGINE)

  • 서용권;허성규;김병휘
    • 한국전산유체공학회지
    • /
    • 제14권1호
    • /
    • pp.9-17
    • /
    • 2009
  • In this study we investigated the characteristics of fluid flow and heat transfer within a coolant passage in the cylinder head assembly of an internal combustion engine by using a commercial CFD code, CFX The complex coolant passage of the cylinder head assembly was modelled by suitable choice of a grid system and careful attention was paid in the construction of meshes near the walls where significant cooling occurs. To treat the simultaneous heating and cooling of the combustion walls we invented a methodology allowing a heat source within the solid wall and the convective cooling at the interface between the solid and the fluid. We managed to reproduce the experimental results by adjusting parameters appropriately. We have found that high temperature was concentrated at the surface of the cylinder jacket. It turned out that the effect of oil cooling from the piston head was unexpectedly significant. On the other hand the effect of cooling from the ambient air is almost negligible. The CFD method proposed in this study is believed to be useful in the early stage of the design of the engine-cooling system.

양방향 스털링엔진의 선형발전기 설계에 관한 연구 (A Study on Design of the Linear Generator in the Double Acting Stirling Engine)

  • 박성제;고준석;홍용주;김효봉;염한길;인세환
    • 한국수소및신에너지학회논문집
    • /
    • 제26권6호
    • /
    • pp.638-644
    • /
    • 2015
  • This paper describes the continuing effort to analysis and design on dynamic and electrical behavior of gamma-type free piston Stirling engine/generator with dual-opposed linear generator for domestic micro-CHP (Combined Heat and Power) system. The double acting Stirling engine/generator has one displacer and two power piston which are supported by flexure springs. Two power pistons oscillate with symmetric sinusoidal displacement and are connected with moving magnet type linear generators for power generation. To operate Stirling engine/generator, combustion heat of natural gas is supplied to hot-end and heat is rejected from cold-end by cooling water. The temperature difference across the displacer induces the oscillating motion, and it can be explained with mass-spring vibration system. The purpose of this paper is to describe the design process of linear generator for the double acting free-piston Stirling engine.

자유 피스톤 스털링엔진/발전기의 설계 인자 연구 (A Study on the Design of the Free-Piston Stirling Engine/Alternator)

  • 박성제;홍용주;고준석;김효봉;염한길;인세환;강인수;이청수
    • 한국수소및신에너지학회논문집
    • /
    • 제25권6호
    • /
    • pp.648-655
    • /
    • 2014
  • This paper describes the continuing effort to develope a single acting free-piston Stirling engine/alternator combination for use of the household cogeneration. Free piston Stirling engines(FPSE) use variations of working gas pressure to drive mechanically unconstrained reciprocating elements. Stirling cycle free-piston engines are driven by the Stirling thermodynamic cycle which is characterized by an externally heated device containing working gas that is continuously re-used in a regenerative, reversible cycle. The ideal cycle is described by two isothermal process connected by two constant volume processes. Heat removed during the constant volume cooling process is internally transferred to the constant volume heating process by mutual use of a thermal storage medium called the regenerator. Since the ideal cycle is reversible, the ideal efficiency is that of Carnot. Free-piston Stirling engine is have no crank and rotating parts to generate lateral forces and require lubrication. The FPSE is typically comprised of two oscillating pistons contained in a common cylinder. The temperature difference across the displacer maintains the oscillations, and the FPSE operate at natural frequency of the mass-spring system. The power is generated from a linear alternator. The purpose of this paper is to describe the design process of the single acting free-piston Stirling engine/alternator. Electrical output of the single acting free-piston Stirling engine/alternator is about 0.95 kW.