• 제목/요약/키워드: Pipes

검색결과 2,267건 처리시간 0.027초

Attenuation of Fundamental Longitudinal Cylindrical Guided Wave Propagating in Liquid-Filled Steel Pipes

  • NA WON-BAE;RYU YEON-SUN;KIM JEONG-TAE
    • 한국해양공학회지
    • /
    • 제19권5호
    • /
    • pp.26-33
    • /
    • 2005
  • Attenuation of fundamental longitudinal guided wave propagating liquid-filled steel pipes is numerically investigated. Several liquids such as water, diesel oil, castor oil etc. are considered for the filing materials in the pipes. Sink is considered for numerical models for abandoning standing wave modes; hence the attenuation dispersion curves become much simpler. Those attenuation calculations can be utilized for guided-wave-based nondestructive testing of pipelines when one inspects pipelines, using monitoring sensors, which are installed outside pipes.

배수관 플러싱의 수리적 현상과 배출수의 수질 특성 (Hydraulics and water quality characteristics of flushing in distribution pipes)

  • 안재찬;이수원;백광인;최영준;최재호;정의선;박현;구자용
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.93-103
    • /
    • 2008
  • This study was conducted to optimize a unidirectional flushing program in distribution pipes by analysis of water pressure, velocity, quality, and other parameters during flushing. As a result, correlation coefficient between flushed pipe length and the flushing duration was obtained $R^2=0.83$ and the equation $Y_{Time}=0.0571{\cdot}X_{Pipe\;length}+4.7648$ for 10 pipes. The averaged flushing velocity in the pipes, 1.1 m/s, was enough to remove loose deposits on the inner wall of the pipes. 3 of 92 water samples taken during flushing met the National Drinking Water Quality Standard for Fe and Mn, but not for Al. Turbidity less than 1 NTU is suggested for the appropriate criteria to finish flushing in pipes. The coefficient of determination ($R^2$) between turbidity and TSS was 0.95 and the equation was induced as $Y_{TSS}=1.2068{\cdot}X_{Turbidity}$. The amount of removed deposits could be estimated from the turbidity data of discharged water in field because turbidity and TSS in the discharged water is highly correlated.

지하매설 배관의 보수를 위한 로봇시스템 개발 (Development of a Robot System for Repairing a Underground Pipe)

  • 여희주
    • 한국산학기술학회논문지
    • /
    • 제13권3호
    • /
    • pp.1270-1274
    • /
    • 2012
  • 국내의 배관시설은 약 30년이 지난 지금 배관의 노후화에 따른 부식 및 결함 등이 나타나기 시작하고 있다. 저비용 고효율의 노후관 갱생을 위한 배관 로봇시스템 개발에 대한 많은 연구가 진행되어 왔다. 배관의 탐사, 표면처리와 도장기술 및 열악한 작업환경에서의 고장에 강인한 로봇시스템 구성은 배관 로봇의 중요한 요인으로 알려져 있다. 지하매설 배관의 관리는 경제적 부담과 고도의 기술이 요구되는 실정에 업체에서 쉽게 대응하기 어려운 실정이다. 이러한 이유로 인하여 본 논문에서는 로봇의 노후관 탐사, 표면처리 및 도장이 가능한 로봇 시스템을 개발하였다. 개발된 로봇은 벽면 압착방식을 이용하여 구동력 및 작업을 위한 견인력을 확보하였다.

지반의 수분 상태에 따른 매립 배관에서의 유도초음파 모드 감쇠 변화 (Effect of Moisture Conditions in Soils on Mode Attenuation of Guided Waves in Buried Pipes)

  • 이주원;신성우;나원배;김영상
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.42-47
    • /
    • 2010
  • Recently, many techniques have been developed for the inspection of pipelines using guided waves. However, few researches have been made on the application of those techniques for buried underground pipes. Guided wave motions in the buried pipes are somewhat different from those of on-ground pipes which have traction-free (air) boundary condition on outer pipe walls and thus are strongly affected by the mechanical property of the surrounding soils. Therefore, it should be investigated the effect of soil properties on the guided wave behavior in buried pipe. On the other hand, the mechanical property of soil is largely depending on its moisture conditions nevertheless of other influential factors such as void ratio. In this study, the effect of moisture conditions in soils on mode attenuation of guided waves in the buried pipe is investigated. To this end, numerical study is performed to characterize mode attenuation behavior in buried pipes and the effective mode which is suitable for long range inspection is identified.

대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책 (The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas)

  • 이장훈;강선홍
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.631-639
    • /
    • 2007
  • This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

상수관로의 잔존수명 평가를 위한 통계적 방법론 (A Statistical Methodology for Evaluating the Residual Life of Water Mains)

  • 박수완;최창록;김정현;배철호
    • 상하수도학회지
    • /
    • 제23권3호
    • /
    • pp.305-313
    • /
    • 2009
  • This paper provides a method for evaluating a residual life of water mains using a proportional hazard model(PHM). The survival time of individual pipe is defined as the elapsed time since installation until a break rate of individual pipe exceeds the Threshold Break Rate. A break rate of an individual pipe is estimated by using the General Pipe Break Model(GPBM). In order to use the GPBM effectively, improvement of the GPBM is presented in this paper by utilizing additional break data that is the cumulative number of pipe break of 0 for the time of installation and adjusting a value of weighting factor(WF). The residual lives and hazard ratios of the case study pipes of which the cumulative number of pipe breaks is more than one is estimated by using the estimated survival function. It is found that the average residual lives of the steel and cast iron pipes are about 25.1 and 21 years, respectively. The hazard rate of the cast iron pipes is found to be higher than the steel pipes until 20 years since installation. However, the hazard rate of the cast iron pipes become lower than the hazard rates of the steel pipes after 20 years since installation.

Uncertainty effects of soil and structural properties on the buckling of flexible pipes shallowly buried in Winkler foundation

  • Khemis, Asma;Chaouche, Abdelmadjid Hacene;Athmani, Allaeddine;Tee, Kong Fah
    • Structural Engineering and Mechanics
    • /
    • 제59권4호
    • /
    • pp.739-759
    • /
    • 2016
  • The failure of civil engineering systems is a consequence of decision making under uncertain conditions. Generally, buried flexible pipes are designed for their transversal behavior to prevent from the important failure mode of buckling. However, the interaction effects between soil and pipe are neglected and the uncertainties in their properties are usually not considered in pipe design. In this regard, the present research paper evaluates the effects of these uncertainties on the uncertainty of the critical buckling hoop force of flexible pipes shallowly buried using the subgrade reaction theory (Winkler model) and First-Order Second-Moment (FOSM) method. The results show that the structural uncertainties of the studied pipes and those of the soil properties have a significant effect on the uncertainty of the critical buckling hoop force, and therefore taking into account these latter in the design of the shallowly flexible pipes for their buckling behavior is required.

유한요소 시뮬레이션을 통한 지역난방열배관 특성 평가 및 강화이형관의 제안 (Design Validation and Improvement of District Heating Pipe Using FE Simulation)

  • 김주용;김호범;고현일;안영모;조종두
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.337-345
    • /
    • 2009
  • This paper investigates the reliability of district heating pipes at thermo-elastic fatigue loading. District heating pipes, subjected to $120^{\circ}C$ and $16kg_f/cm^2$ due to water distributing service through inside the pipes, should endure long term cyclic thermal-mechanical loadings. The heating pipes are the co-centric tubes of steel pipe, poly urethane(PUR) insulator, and high density poly ethylene(HDPE) case. On installation, foam pad is externally wrapped for accommodating stress reduction near the bend sections of pipes. However, there have been frequent reports on the failures of bend sections in the middle of long term service. This study scrutinizes the observed failures near the bend sections through applying the finite element methods. Specially in this study, heating pipes are studied on the influence of foam padding on failures and proposed new designs for reinforced bend without foam pad.

토양매설 스테인리스강 상수도 배관의 부식원인 규명 (Elucidation of Corrosion and Failure of Stainless Steel Tubing buried in Soil for Potable Water)

  • 김영식;박수진;황보덕;신민철
    • Corrosion Science and Technology
    • /
    • 제11권1호
    • /
    • pp.20-28
    • /
    • 2012
  • Since buried pipes contact the soil directly, corrosion by the soil could be occurred. Recently, some stainless steel pipes after 8 years burial at G area were corroded and leaked. In order to elucidate highly corroded phenomena(its rate was about 0.175 mm/y) of these pipes, the investigation for corrosion environment, soil, stray current's effect, and chemical analysis on the pipes were performed. Most of investigated sites were close to traditional water-closet and showed high moisture and thus those areas could be highly corrosive. In the investigation by two kinds of soil evaluation methods, it was revealed that the soils at G areas were highly corrosive, and moreover the contents of sulfate reducing bacteria in the soils were high. Also, open circuit potentials of many pipes showed different values and its potentials were high positive. Therefore, it was considered that corrosion of buried pipes at G area could be affected by high corrosive soil's environment and stray current corrosion.

침식-부식에 의해 감육된 배관의 파손거동에 미치는 감육위치의 영향 (Effect of Local Wall Thinned Location due to Erosion-Corrosion on Fracture Behavior of Pipes)

  • 안석환;석금철;남기우
    • 한국해양공학회지
    • /
    • 제21권1호
    • /
    • pp.51-58
    • /
    • 2007
  • This study on the effects of local wall-thinned location on the fracture behavior of pipes was carried out, and the results were compared with the analytical results. Local wall-thinning for the bending test was machined with various sizes on the outside of pipes, in order to simulate the metal loss, due to erosion/corrosion. In addition, we had carried out FE analysis for the pipes with local wall thinning on the inside, and its results were comparatively studied with that of the outside. Three-dimensional elasto-plastic analyses were able to accurately simulate fracture behaviors of inner or outer wall thinning. Fracture types, obtained from the experiments and analyses, could be classified into ovalization, local buckling and crack initiation, depending on the thinned length and thinned ratio. Based on the results, the fracture behaviors of pipes with the outer wall thinning can be applied to estimate the fracture behaviors of pipes with the inner wall thinning.