• 제목/요약/키워드: Pipes

검색결과 2,286건 처리시간 0.027초

감육배관의 굽힘하중에 의한 손상모드와 파괴거동 평가 (Failure Mode and Fracture Behavior Evaluation of Pipes with Local Wall Thinning Subjected to Bending Load)

  • 안석환;남기우;김선진;김진환;김현수;도재윤
    • 대한기계학회논문집A
    • /
    • 제27권1호
    • /
    • pp.8-17
    • /
    • 2003
  • Fracture behaviors of pipes with local wall thinning are very important for the integrity of nuclear Power Plant. In Pipes of energy Plants, sometimes, the local wall thinning may result from severe erosion-corrosion (E/C) damage. However, the effects of local wall thinning on strength and fracture behaviors of piping system were not well studied. In this paper, the monotonic bending tests were performed of full-scale carbon steel pipes with local wall thinning. A monotonic bending load was applied to straight pipe specimens by four-point loading at ambient temperature without internal pressure. From the tests, fracture behaviors and fracture strength of locally thinned pipe were manifested systematically. The observed failure modes were divided into four types; ovalization. crack initiation/growth after ovalization, local buckling and crack initiation/growth after local buckling. Also, the strength and the allowable limit of piping system with local wall thinning were evaluated.

현장 열응답 시험을 통한 에너지파일의 열교환파이프 배열 방식에 따른 성능 비교 (Performance-based comparison of energy pile of various heat exchange pipe arrangement by in-situ thermal response test)

  • 민선홍;고형선;유재현;정경식;이영진;최항석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.196.1-196.1
    • /
    • 2011
  • In this study, a test bed was constructed in order to evaluate thermal efficiency of the energy pile which carries out combined roles of a structural foundation and of a heat exchanger. The energy pile in this study is designed as a large-diameter drilled shaft equipped with the heat exchange pipes which configures a W-shape and an S-shape. The drilled shaft reached to the depth of 60 m whilst the heat exchange pipes were installed to about 30 m deep from the ground surface. The W-shaped and S-shaped heat exchange pipes were installed in the opposite sections of the same drilled shaft. In-situ thermal response tests were performed for both the shapes of heat exchange pipes. To avoid underestimating the thermal performance due to hydration heat of concrete inside the drilled shaft, the in-situ thermal response tests for the energy pile were performed after four weeks since the installation of the energy pile.

  • PDF

Applicability of Existing Fracture Initiation Models to Modern Line Pipe Steels

  • Shim, Do Jun
    • 한국압력기기공학회 논문집
    • /
    • 제12권2호
    • /
    • pp.1-24
    • /
    • 2016
  • The original fracture criteria developed by Maxey/Kiefner for axial through-wall and surface-cracked pipes have worked well for many industries for a large variety of relatively low strength and toughness materials. However, newer line pipe steels have some unusual characteristics that differ from these older materials. One example is a test data that has demonstrated that X80 line-pipe with an axial through-wall-crack can fail at pressures about 30 percent lower than predicted with commonly used analysis methods for older steels. Thus, it is essential to review the currently available models and investigate the applicability of these models to newer high-strength line pipe materials. In this paper, the available models for predicting the failure behavior of axial-cracked pipes (through-wall-cracked and external surface-cracked pipes) were reviewed. Furthermore, the applicability of these models to high-strength steel pipes was investigated by analyzing limited full-scale pipe fracture initiation test results. Based on the analyzed results, the shortcomings of the available models were identified. For both through-wall and surface cracks, the major shortcomings were related to the characterization of the material toughness, which generally leads to non-conservative predictions in the J-T analyses. The findings in this paper may be limited to the test data that were consider for this study. The requisite characteristics of a potential model were also identified in the present paper.

지중 매설 GFRP 관로 및 플랜지의 거동 분석 (Behavior Analysis of Buried GFRP Pipes and Flanges)

  • 한택희;김효산;장영두;박윤호;강영종
    • 복합신소재구조학회 논문집
    • /
    • 제1권1호
    • /
    • pp.27-33
    • /
    • 2010
  • Static analyses and buckling analyses were carried out for buried GFRP pipes by using finite element method. Vehicle loads, vertical and lateral soil pressures were considered as external loads, and supplying water pressure was considered as an internal load. Nine types of the factory-manufactured GFRP pipes were analyzed. Their maximum stresses and displacements were compared with the limit displacements and ultimate stress. Additionally, stress analysis on an enhanced flange, which was designed to reduce stress concentration, was performed. A cantilever analysis was carried out to know the maximum stress on the neck of the flange, which is the critical part. And a static analysis was carried for the buried flange. The test results showed that GFRP pipes were safe and stable against the external loads. And they showed that the enhanced flange decreased about 35% of the stress concentration.

  • PDF

지보공법에 따른 토사터널의 거동에 관한 수치해석 (Numerical Analysis on the Behavior of the Earth Tunnel due to Supporting Methods)

  • 김진태;박병수;정길수;유남재
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.239-250
    • /
    • 2004
  • Numerical analysis were performed to investigate the stability and internal movement of tunnel located beneath the base of abutment of bridge according to the method of supporting tunnel. Two supporting methods of the multi-staged grouting method with steel pipes and the large diameter of pipe supporting method were used in the centrifuge model tests. The slip form of model lining, specially built to simulate the process of tunnel excavating under the condition of accelerated g-level, was used in the centrifuge model tests. Four centrifuge model tests were performed, changing the supporting methods of the multi-staged grouting method with steel pipes and the large diameter of pipe supporting method and the location of model abutment base of bridge. For internal displacement of tunnel, movements of the crown. The left and the right sides of spring line were measured during the proceeds of excavating tunnel in centrifuge model tests. Test results were compared with numerically estimated values of internal displacement of tunnel by using the commercially available FEM software of PENTAGON-3D. It was found that they were in good agreements and the large diameter of pipe supporting method was more stable than the multi-staged grouting method with steel pipes with respect to the internal movement of tunnel.

  • PDF

참조응력 개념을 이용한 원주방향 관통균열 배관의 파괴역학 해석;실배관 실험 데이터와의 비교 (Reference Stress Based Fracture Mechanics Analysis for Circumferential Through-Wall Cracked Pipes;Comparison with Pipe Test Data)

  • 허남수;심도준;김윤재;김영진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.389-396
    • /
    • 2003
  • This paper presents experimental validation of the enhanced reference stress based J estimates for circumferential through-wall cracked pipes, recently proposed by authors. Using the pipe test data for circumferential through-wall cracked pipes, the predicted fracture initiation and maximum moments according to the proposed enhanced reference stress method are compared with experimental ones as well as predictions from the R6 method. The results show that both the R6 method and the proposed method give conservative estimates of initiation and maximum moments for circumferential through-wall cracked pipes, compared to experimental data. For longer cracks, the proposed method reduces conservatism embedded in estimated J according to the R6 method, and the resulting predictions are less conservative, compared to those from the R6 method. For shorter cracks, on the other hand, the proposed method reduces possible non-conservatism embedded in estimated J according to the R6 method, and the resulting predictions are slightly more conservative.

  • PDF

원전 배관의 파손확률에 대한 검사의 영향 (Effect of Inspection on Failure Probability of Pipes in Nuclear Power Plants)

  • 박재학;최영환
    • 대한기계학회논문집A
    • /
    • 제36권10호
    • /
    • pp.1249-1254
    • /
    • 2012
  • 원자력발전소의 배관에 대하여 행하는 검사는 배관의 구조건전성에 큰 영향을 미친다. 그러나 검사에는 많은 인력과 비용이 소요되므로 검사의 영향을 평가하여 최적의 검사주기와 검사품질을 결정하는 것이 중요하다. 본 논문에서는 원자력발전소 배관의 파손확률을 평가할 수 있도록 개발된 P-PIE 프로그램을 사용하여 검사의 유무, 검사주기 및 검사품질 등이 배관의 파손확률에 미치는 영향을 살펴보았다. 국내 원전의 배관 데이터를 사용하여 해석하였으며, 피로 및 부식에 의한 균열성장을 고려하였다.

수도관의 부기거동에 관한 연구 (Corrosion Behaviour of Water Pipes)

  • 김원만;박영식
    • 환경위생공학
    • /
    • 제7권1호
    • /
    • pp.1-16
    • /
    • 1992
  • Corrosion of pipes Is one of the most serious problems in the maintenance of water worlds. Corrosion is promoted not only by physical factors such as temperature, but also by electrochemical factors including concentration of soluble metal ions, chlorine ion, pH, DO and microorganisms. Corrosion products also affect corrosion rate. In this research, study results are summarized as follows ; 1) Corrosion test was performed for 4 weeks at $70^{\circ}C$, pH 7.0 with specimens of 4 types of metal materials used as service pipes. Corrosion rate and S.E.M were analyzed. The results were showed that corrosion 1.ate of carbon steel pipe was 4.10~5.22 $mg/\textrm{cm}^2$ . week, galvanized steel pipe 0.98~1.34$mg/\textrm{cm}^2$. week, Copper pipe 0.02~0.04$mg/\textrm{cm}^2$. week, stainless steel pipe 0.05~ 0.10$mg/\textrm{cm}^2$ . week. 2) When corrosion rate was tested for tile types of pipes at pH 7 and both $25^{\circ}C$ and $75^{\circ}C$, avaerage corrosion rate for 6 weeks at $25^{\circ}C$ Ivas 2.26$mg/\textrm{cm}^2$ . week in carbon steel pipe, 1.99$mg/\textrm{cm}^2$. week in galvanized steel pipe, 0.26 $mg/\textrm{cm}^2$. week in stainless steel pipe. At $87^{\circ}C$, average corrosion rate for 4 weeks u.3s 4.56 $mg/\textrm{cm}^2$. week in carbon steel pipe,

  • PDF

Turbulent Flow Field Structure of Initially Asymmetric Jets

  • Kim, Kyung-Hoon;Kim, Bong-Whan;Kim, Suk-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제14권12호
    • /
    • pp.1386-1395
    • /
    • 2000
  • The mear field structure of round turbulent jets with initially asymmetric velocity distributions is investigated experimentally. Experiments are carried out using a constant temperature hot-wire anemometry system to measure streamwise velocity in the jets. The measurements are undertaken across the jet at various streamwise stations in a range starting from the jet exit plane and up to a downstream location of twelve diameters. The experimental results include the distributions of mean and instantaneous velocities, vorticity field, turbulence intensity, and the Reynolds shear stresses. The asymmetry of the jet exit plane was obtained by using circular cross-section pipes with a bend upstream of the exit. There pipes used here include a straight pipe, and 90 and 160 degree-bend pipes. Therefore, at the upstream of the upstream of the pipe exit, secondary flow through the bend mean streamwise velocity distribution could be controlled by changing the curvature of pipes. The jets into the atmosphere have two levels of initial velocity skewness in addition to an axisymmetric jet from a straight pipe. In case of the curved pipe, a six diameter-long straight pipe section follows the bend upstream of the exit. The Reynolds number based on the exit bulk velocity is 13,400. The results indicate that the near field structure is considerably modified by the skewness of an initial mean velocity distribution. As the skewness increases, the decay rate of mean velocity at the centerline also increases.

  • PDF

고속도로 하부 횡단 배수시설로 사용되는 파형 플래스틱 관의 덮개 요건 (Cover Requirements for Corrugated HDPE and PVC Pipes Used for Cross-drains in Highway Construction)

  • 강준석;;임정현;강영종
    • 복합신소재구조학회 논문집
    • /
    • 제4권1호
    • /
    • pp.15-24
    • /
    • 2013
  • This project investigated the use of two types of thermoplastic pipes, High-Density Polyethylene (HDPE) and Poly-vinyl Chloride (PVC), as cross-drains under highways. Pipes ranging from 0.3 m (12 in.) to 1.5 m (60 in.) in diameter were evaluated under deep fills, minimum cover, and construction loads. In addition to a comprehensive literature review, an analytical study into the allowable fill heights for thermoplastic pipes and a field study to observe the installation and performance of the pipe in service conditions were conducted. Based on the study findings, recommendations regarding how and when thermoplastic pipe should be installed are provided.