• Title/Summary/Keyword: Pipeline system

Search Result 786, Processing Time 0.026 seconds

Cathodic Protection of Buried Gas Pipelines Using Common Anode Beds (공용양극을 이용한 가스배관의 전기방식)

  • Ha, Y.C.;Kim, D.K.;Bae, J.H.;Ha, T.H.;Lee, H.G.
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.19-24
    • /
    • 2008
  • Due to industrialization and urbanization, underground metallic utilities with different owners have been rapidly increased and cathodic protection (CP) methods, especially impressed current CP systems, have been widely adopted to protect their utilities from corrosion with expanded recognition of this method. The stray current interference problem as well as the difficulty in spatial security for system installation, however, came to a ramification of which each owner couldn't resolve for himself. In this respect, this paper illustrates a field-diagnosed example for mutual interference due to separately operated CP systems and suggests an alternative method to overcome the interference situation by design and field-assessment of a common anode bed cathodic protection system.

  • PDF

Implementation of Channel Coding System using Viterbi Decoder of Pipeline-based Multi-Window (파이프라인 기반 다중윈도방식의 비터비 디코더를 이용한 채널 코딩 시스템의 구현)

  • Seo Young-Ho;Kim Dong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.587-594
    • /
    • 2005
  • In the paper, after we propose a viterbi decoder which has multiple buffering and parallel processing decoding scheme through expanding time-divided imput signal, and map a FPGA, we implement a channel coding system together with PC-based software. Continuous input signal is buffered as order of decoding length and is parallel decoded using a high speed cell for viterbi decoding. Output data rate increases linearly with the cell formed the viterbi decoder, and flexible operation can be satisfied by programming controller and modifying input buffer. The tell for viterbi decoder consists of HD block for calculating hamming distance, CM block for calculating value in each state, TB block for trace-back operation, and LIFO. The implemented cell of viterbi decoder used 351 LAB(Logic Arrary Block) and stably operated in maximum 139MHz in APEX20KC EP20K600CB652-7 FPGA of ALTERA. The whole viterbi decoder including viterbi decoding cells, input/output buffers, and a controller occupied the hardware resource of $23\%$ and has the output data rate of 1Gbps.

Efficient pipelined FFT processor for the MIMO-OFDM systems (MIMO-OFDM 시스템을 위한 효율적인 파이프라인 FFT 프로세서의 설계)

  • Lee, Sang-Min;Jung, Yun-Ho;Kim, Jae-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10C
    • /
    • pp.1025-1031
    • /
    • 2007
  • This paper proposes an area-efficient pipeline FFT processor for MIMO-OFDM systems with four transmitting and four receiving antennas. Since the MIMO-OFDM system transmits multiple data streams, the complexity for the MIMO-OFDM system with a single-channel FFT processor increases linearly with the increase of the number of transmit channels. The proposed FFT processor is based on multi-channel structure, and therefore it can efficiently support multiple data streams. With the mixed radix algorithm, the number of non-trivial multiplications of the proposed FFT processor is decreased. The proposed FFT processor is synthesized with CMOS $0.18{\mu}m$ process and reduces the logic gates by 25% over a 4-channel Radix-4 multi-path delay commutator (R4MDC) FFT processor. Since the MIMO-OFDM FFT processor is one of the largest modules in the systems, the proposed FFT processor will be a vast contribution improvement to the low complexity design of MIMO-OFDM systems.

Improved Estimation of Leak Location of Pipelines Using Frequency Band Variation (주파수 대역 변화를 이용한 배관의 누수지점 추정 개선 연구)

  • Lee, Young-Sup;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.44-52
    • /
    • 2014
  • Leakage is an important factor to be considered for the management of underground water supply pipelines in a smart water grid system, especially if the pipelines are aged and buried under the pavement or various structures of a highly populated city. Because the exact detection of the location of such leaks in pipelines is essential for their efficient operation, a new methodology for leak location detection based on frequency band variation, windowing filters, and probability is proposed in this paper. Because the exact detection of the leak location depends on the precision of estimation of time delay between sensor signals due to leak noise, some window functions that offer weightings at significant frequencies are applied for calculating the improved cross-correlation function. Experimental results obtained by applying this methodology to an actual buried water supply pipeline, ~ 253.9 m long and made of cast iron, revealed that the approach of frequency band variation with those windows and probability offers better performance for leak location detection.

The Study on a Reservoir Environment Development Method of Coast Small Islands using 0-1 Integer Programming (0-1 정수 계획법을 이용한 해양 도서지역 상수원 환경 개발 방법에 관한 연구)

  • Joo, K.S.;Park, S.H.
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.2 s.29
    • /
    • pp.127-132
    • /
    • 2007
  • This study is to determine an optimal reservoir among many alternative proposals in order to obtain the maximized efficiency under the limited budget. There are many alternative proposals which deal with problems to assign reservoir such as water conversion establishment construction, subterranean water, reservoir, submarine pipeline, water boat, and marine water saving base construction. In this paper, the new model to assign the most reasonable alternative is introduced using 0-1 integer programming. This proposed model has not been applied in the optimal reservoir selection problem yet. This paper will contribute to determine the most reasonable alternative to minimize budget under constraints. Also, this proposal model can be applied to other reservoir selection problem in other regions.

  • PDF

FPGA Implementation of Levenverg-Marquardt Algorithm (LM(Levenberg-Marquardt) 알고리즘의 FPGA 구현)

  • Lee, Myung-Jin;Jung, Yong-Jin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.73-82
    • /
    • 2014
  • The LM algorithm is used in solving the least square problem in a non linear system, and is used in various fields. However, in cases the applied field's target functionis complicated and high-dimensional, it takes a lot of time solving the inner matrix and vector operations. In such cases, the LM algorithm is unsuitable in embedded environment and requires a hardware accelerator. In this paper, we implemented the LM algorithm in hardware. In the implementation, we used pipeline stages to divide the target function operation, and reduced the period of data input of the matrix and vector operations in order to accelerate the speed. To measure the performance of the implemented hardware, we applied the refining fundamental matrix(RFM), which is a part of 3D reconstruction application. As a result, the implemented system showed similar performance compared to software, and the execution speed increased in a product of 74.3.

Research on MFL PIG Design for caustic and defect the Inspection of Underground Gas Pipeline (지하매설 가스관의 부식 및 결함 탐지를 위한 비파괴 누설 탐상시스템 개발에 관한 연구)

  • Park, Sang-Ho;Park, Gwan-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.11-20
    • /
    • 2002
  • This paper describes the magnetic flux leakage(MFL) type non-destructive testing(NDT) system to detect the 3D defects on underground gas pipe. Magnetic systems with permanent magnets and yokes are analyzed by 3D non-lineal finite element method(FEM) with optimum design. In case of under-saturation of gas pipe, sensing signals are too weak to detect. In case of over-saturation, the changes of the sensing signals are too low to detect the defects sensitively. So, the operating points of the magnetic system are optimized to increase the changes of the MFL signals. The effects of the depth and size of the defects on the sensing signals are analyzed to define the range and resolution of the MFL sensors. To increase the sensor's sensitivity, the back-yoke sensors are introduced and tested.

  • PDF

Analysis of Steady Flow by Main Pipe Arrangement in the Water Distributing Pipe Network (배수관망(配水管網)의 간선배치(幹線配置)에 따른 정류(定流)흐름 해석(解析))

  • Lee, Jeung Seok;Park, Ro Sam;Kim, Jee Hak;Choi, Yun Young;Ahn, Seung Seop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.73-82
    • /
    • 1999
  • In this study, the optimal analysis for pipe network is performed for the combined ideal pipe network system(CASE 1, CASE 2 and CASE 3) which is composed of 25 nodes, 41 elements, and 1 fixed nodal head with evaluating pressure variation distribution of main and branch in grid composed drainage pipe network. The linear analysis technique used as the analysis method in this study, the KYPIPE being used extensively as the linear technique to design and analysis of pipe network is applied. Firstly, in the analysis of pipe network, the CASE 2 and CASE 3 supply same thing(value) in the result of considering the total flow provided each pipeline, but in the general intension in the case of CASE 2, relative width of supply is more large than CASE 1 and CASE 3. Secondly, in the analysis technique of pipe network, CASE 3 is analysed largest as a result of comparing with same heads, and in the order of their size CASE 2 and CASE 1 were determined but the difference doesn't appear to be obvious. Thirdly, as the result of determining main factor, pressure in the design and analysis of net work. CASE 3 is from Node 3 to 25 than CASE 1 and CASE 2 and it is determined in the order of their size, CASE 2 and CASE 1. Finally, in this study, discharge flow distribution is evaluated in the same condition with 3-type CASE in the case of branch position for designing optimal composed drainage pipe network. As the result of that, branch pipe perform. Therefore, it is thought that the efficient and reasonable management of water supply and sewerage design will be possible if it give all our energies to study at the pipe system design in and out of country in the future.

  • PDF

Design of Image Extraction Hardware for Hand Gesture Vision Recognition

  • Lee, Chang-Yong;Kwon, So-Young;Kim, Young-Hyung;Lee, Yong-Hwan
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.1
    • /
    • pp.71-83
    • /
    • 2020
  • In this paper, we propose a system that can detect the shape of a hand at high speed using an FPGA. The hand-shape detection system is designed using Verilog HDL, a hardware language that can process in parallel instead of sequentially running C++ because real-time processing is important. There are several methods for hand gesture recognition, but the image processing method is used. Since the human eye is sensitive to brightness, the YCbCr color model was selected among various color expression methods to obtain a result that is less affected by lighting. For the CbCr elements, only the components corresponding to the skin color are filtered out from the input image by utilizing the restriction conditions. In order to increase the speed of object recognition, a median filter that removes noise present in the input image is used, and this filter is designed to allow comparison of values and extraction of intermediate values at the same time to reduce the amount of computation. For parallel processing, it is designed to locate the centerline of the hand during scanning and sorting the stored data. The line with the highest count is selected as the center line of the hand, and the size of the hand is determined based on the count, and the hand and arm parts are separated. The designed hardware circuit satisfied the target operating frequency and the number of gates.

An Evaluation of Heating Performance of the Heat Pump System Using Wasted Heat from Thermal Effluent for Greenhouse Facilities in Jeju (발전소 온배수 폐열을 이용한 제주 시설온실 냉난방용 열펌프 시스템의 난방성능 평가)

  • Moon, Sungbu;Hyun, Myung-Taek;Heo, Jaehyeok;Lee, Dong-Won;Lee, Yeon-Gun
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • A heat pump system using wasted heat from thermal effluent to supply the heating energy can reduce energy consumption and emissions of greenhouse gases by greenhouse facilities nearby. The Jeju National University consortium constructed a heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO to provide with cool or hot water to greenhouse facilities located 3 km from the power station. In this paper, the system configuration of the heat pump system was summarized, and the results of operations for demonstration of a heating performance carried out during the winter season in 2018 were investigated. The preoperational tests proved that the water temperature drop through the pipeline transporting extracted heat was less than $2^{\circ}C$. The COP (coefficient of performance) of the heat pump was higher than 4.0, and hot water with the maximum temperature of $50^{\circ}C$ could be supplied to greenhouse facilities by utilizing wasted heat from thermal effluent.