Journal of the Korean Institute of Gas (한국가스학회지)
- Volume 12 Issue 1
- /
- Pages.19-24
- /
- 2008
- /
- 1226-8402(pISSN)
- /
- 2713-6922(eISSN)
Cathodic Protection of Buried Gas Pipelines Using Common Anode Beds
공용양극을 이용한 가스배관의 전기방식
- Ha, Y.C. (Electric Power Research Division, KERI) ;
- Kim, D.K. (Electric Power Research Division, KERI) ;
- Bae, J.H. (Electric Power Research Division, KERI) ;
- Ha, T.H. (Electric Power Research Division, KERI) ;
- Lee, H.G. (Electric Power Research Division, KERI)
- 하윤철 (한국전기연구원 전력연구단) ;
- 김대경 (한국전기연구원 전력연구단) ;
- 배정효 (한국전기연구원 전력연구단) ;
- 하태현 (한국전기연구원 전력연구단) ;
- 이현구 (한국전기연구원 전력연구단)
- Published : 2008.03.30
Abstract
Due to industrialization and urbanization, underground metallic utilities with different owners have been rapidly increased and cathodic protection (CP) methods, especially impressed current CP systems, have been widely adopted to protect their utilities from corrosion with expanded recognition of this method. The stray current interference problem as well as the difficulty in spatial security for system installation, however, came to a ramification of which each owner couldn't resolve for himself. In this respect, this paper illustrates a field-diagnosed example for mutual interference due to separately operated CP systems and suggests an alternative method to overcome the interference situation by design and field-assessment of a common anode bed cathodic protection system.
산업화, 도시화에 따라 관리 주체가 다른 지중 금속시설물들이 크게 늘고 있으며 이러한 시설물의 보호를 위한 전기방식법, 특히 외부전원법의 적용이 전기방식에 대한 인식의 확산과 더불어 크게 증가하고 있다. 그러나 시스템의 설치를 위한 공간 확보의 어려움과 더불어 시설물 상호간의 표류전류 간섭 문제가 개별 관리주체로서는 해결할 수 없는 현안이 되고 있다. 이에 본 논문에서는 개별적으로 적용되던 전기방식 시스템 상호간의 간섭 사례를 현장 진단을 통하여 예시하고 이에 대한 대책으로 공용양극 외부전원 시스템을 설계, 현장 실증을 통하여 하나의 대안으로 제시하였다.
Keywords