• Title/Summary/Keyword: Pipe-line

Search Result 499, Processing Time 0.03 seconds

A Development of Pipe Safety Management System by GIS (GIS를 이용한 상수도관의 안전도 관리시스템 개발)

  • 최병길;조영호;전왕규
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.2
    • /
    • pp.311-317
    • /
    • 1998
  • GIS is the system that has ability of integrating, managing, and analyzing the voluminous graphic and text data, which is adequate system to manage complex network of the underground utilities of urban area. A development of pipe safety management system is accomplished to construct efficiently a database of pipe line network and topographic data, create safety managing model, and estimate openly its safety by GIS. This system is constructed to evaluate easily pipe deterioration by the establishment of the geographic output system on it, search damaged objectives near surrounding area in a situation of destruction, and offer the information by which one can take quickly emergency. And also, it is constructed to prevent from accident occurring under work by presenting underground utilities and states of work.

  • PDF

Effect of cake resistance by first-aggregation of in-line injection system (인라인 주입방식의 최초응집이 케이크 저항에 미치는 영향)

  • KIM, Taeyoung;PARK, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.281-288
    • /
    • 2008
  • Cake resistance is influenced by floc size deposited on membrane surface. Enlarging floc size can reduce cake resistance. The small particles are enlarged by coagulation and flocculation process in conventional mixing tank at membrane filtration system. Fully-grown flocs for reducing the cake resistance, however, are ruptured while passing through a pump. In light of this fact, this study aims to experimentally look at the reaggregation phenomenon of mixing system. In addition, reaggregation phenomenon of mixing system is compared with first-aggregation of in-line injection system in which coagulant is injected just before a pump. These results suggest that first-aggregation of in-line injection system is better than reaggregation of mixing system for G-value above $3100sec^{-1}$. Since G-value in pipe of actual membrane filtration system are usually larger than $3100sec^{-1}$. The performance of in-line injection system is expected to be better than the conventional mixing tank system.

Conceptual Design of Penumatic System Routing for Liquid Rocket Engine (액체로켓엔진의 공압류 라우팅 개념 설계)

  • Kim, Okkoo;Park, Soonyoung;Jung, Eunhwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1112-1114
    • /
    • 2017
  • The liquid rocket engine determines the routing of the component placement and layout by adapted the cycle method, the hardware configuration, the gimbal type on the functional implementation, and so on. In this paper, the conceptual routing of major pneumatic lines such as helium (He) supply pneumatic line for driving, many purge pneumatic line and main ignition line based on the main components installed in the liquid rocket engine was performed.

  • PDF

DATA LOGGER APPARATUS FOR MEASUREMENT STRAY CURRENT OF SUBWAY AND POWER LINE (지하철과 전력선의 누설전류 측정을 위한 저장형 데이터 계측장치)

  • Bae, Jeong-Hyo;Ha, Yun-Cheol;Ha, Tae-Hyeon;Lee, Hyeon-Gu;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.731-734
    • /
    • 2003
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.

  • PDF

Performance Comparison Study on LFLP and DBLP Daylighting System (LFLP와 DBLP 자연채광시스템의 성능평가 비교 연구)

  • Choi, Jeon-Yong;Kang, Eun-Chul;Lee, Euy-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.799-804
    • /
    • 2011
  • The LFLP (Linear Fresnel Light Pipe) system uses a linear Fresnel lens to follow the sun and concentrates the parallel sunlight into a line. A LFLP daylighting system has been developed and updated to a DBLP (Double Blind Light Pipe) daylighting system to improve the overall system efficiency in the morning and afternoon. The new design consists of a double-blind style with a cone-shaped light transformer. The blinds are used to collect the sun's altitude and azimuth movements through the day. Behind the two sets of blinds is the light transformer, which is based on a parabolic-shaped light concentrator. The light transformer is designed to efficiently deliver light within a thirty-degree radial spread so that the light pipe can internally reflect the light. The results of scale-model tests are encouraging, and the efficiency is three times higher than that of the previous LFLP system.

Corrosion Failure Analysis of a Biogas Pipe (바이오가스 배관의 부식 파손 원인 분석)

  • Min Ji Song;Woo Cheol Kim;Heesan Kim;Jung-Gu Kim;Soo Yeol Lee
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.3
    • /
    • pp.153-160
    • /
    • 2023
  • The use of biogas is an industrially necessary means to achieve resource circulation. However, since biogas obtained from waste frequently causes corrosion in pipes, it is important to elucidate corrosion mechanisms of the pipes used for biogas transportation. Recently, corrosion failure occurred in a pipe which supplied for the biogas at the speed of 12.5 m/s. Pinholes and pits were found in a straight line along the seamline of the pipe. By using corrosion-damaged samples, residual thickness, microstructure, and composition of oxide film and inclusion were examined to analyze the cause of the failure. It was revealed that the thickness reduction of biogas pipe was ~0.11 mm per year. A thin sulfuric acid film was formed on the surface of the interior of a pipe due to moisture and hydrogen sulfide contained in a biogas. Near the seamline, microstructure was heterogeneous and manganese sulfide (MnS) was found. Pits were generated by micro-galvanic corrosion between the manganese sulfide and the matrix in the interior of the pipe along the seamline. In addition, microcracks formed along the grain boundaries beneath the pits revealed that hydrogen-induced cracking (HIC) also contributed to accelerating the pitting corrosion.

Empirical study on inhibition effect of scale and rust in tap-water line by zinc ionization device (아연 이온화 장치에 의한 상수배관 내 스케일 및 녹 생성 억제효과 실증 연구)

  • Yum, Kyung-Taek;Choi, Jung-Wook;Yang, Sung-Bong;Shim, Hak-Sup;Yu, Mee-Seon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.465-476
    • /
    • 2021
  • Scale and rust generation in water pipes is a common phenomenon when cast iron water pipes have been used for a long time. A physical water treatment device is known among various means for suppressing rust in a water pipe, and a zinc ionization device for putting zinc metal into a pipe and emitting the zinc cation into water is one of such devices. This research measured the amount of zinc ion generated, which is known to exhibit an effect of inhibiting rust and scale generation in a pipe, and examined the scale and rust inhibition effect of the ionization device installed for ground or building water supply. In the case of distilled water, the concentration of zinc ion increased by circulating water in the ionization device several times, and it was verified to be hundreds of ㎍/L, and in the case of discharging ground or tap water, it was verified to be tens of ㎍/L. In addition, a verification pipe was installed to confirm the change inside the pipe before and after installation of the zinc ionization device, and the internal condition of the pipe was observed 3 months to several years after installation. It was confirmed that the corrosion area of the surface of the pipe was no longer increased by installing a corrosion inhibitor, and if the pipe was already filled with corrosion products, the amount of corrosion products gradually decreased every year after installation. The phenomenon of fewer corrosion products could be interpreted as expanding the space in the pipe due to the corrosion product as Fe2O3 adhered to the inner surface of the pipe and turned into a smaller black Fe3O4. In addition, we found that scale such as CaCO3 together in the corrosion by-products gradually decreased with the attachment of the ionization device.