발전소 복수 공급 배관계의 고진동과 분기 배기배관의 절손 규명 (Examination on High Vibration and Branch Vent Pipe's Failure of Complex Piping System Suppling Condensate-Water in Power Site)

  • 김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.380-384
    • /
    • 2010
  • A disturbance flow at piping bands and discontinuous regions such as a valve, a header has a intense broadband internal pressure field and a sound field which are propagated through the piping system The fields becomes the source of a vibration of this piping system. Intense broadband disturbance flow at a discontinuous region such as elbows, valves or headers generates an acoustical pulsation. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the high vibration and the branch vent pipe's failure of condensate-water supply piping system due to the effect of acoustical pulsations by flow turbulence from the flow control valves of globe type in a power site.

  • PDF

가변속 왕복동형 압축기 본체의 동적 거동 해석 (Dynamic Behavior Analysis of a Reciprocating Compressor Body with Variable Rotating Speed)

  • 김태종
    • 한국소음진동공학회논문집
    • /
    • 제11권8호
    • /
    • pp.374-383
    • /
    • 2001
  • A reciprocating compressor unit with variable rotating speed driven by BLDC motor is mounted Inside hermetic chamber on an internal suspension composed of 4 roil springs and a discharge pipe. A method for predicting the dynamic behavior of compressor body is required for a reduction of transmitted vibrations. The mechanical characteristics of spring and discharge pipe stiffness properties have been obtained from experimental tests and mass moment of inertia of the compressor body iron CAD. To confirm the vibration model for the compressor body, free vibration analyses are performed with theoretical and experimental methods. results for analytical investigations on the dynamic behavior of the compressor body and the transmitted forces to the hermetic chamber through the suspension elements are Presented.

  • PDF

유체가 흐르는 가스파이프의 진동 특성 (Vibrational Characteristics of the Gas Pipelines Conveying Flow)

  • 김경태;이성수;이성우
    • 한국생산제조학회지
    • /
    • 제21권2호
    • /
    • pp.337-343
    • /
    • 2012
  • This work investigates the vibrational characteristics of the underground gas pipelines. Experiments were conducted to analyze the effects of various parameters on the vibrational characteristics from the emergency detection point of view. Influences of the various types of impact exerted on the pipe, height of free fall and measuring locations were analyzed. Especially, the difference between the vibrational signal generated by the direct impact on the pipe and the ambient noise was successfully identified. To validate the experimental observation, computer simulation was also performed with constant properties(elasticity, fluid velocity and internal pressure) which are directly conjectured from the accompanying experiment with a real pipe system.

다중 다공판 시스템에서 직관요소에 대한 전기음향등가회로법의 오류 (The Error Involved in the Equivalent Electroacoustic Circuit Approach for the Element of Straight Pipe in Multiple Layer Perforated Plate Systems)

  • 이동훈;권영필
    • 한국소음진동공학회논문집
    • /
    • 제13권3호
    • /
    • pp.180-185
    • /
    • 2003
  • The equivalent electroacoustic circuit approach has been conventionally used for the analysis of the multiple layer perforated plate system. However, it is found that an analogy error has been involved in the equivalent electroacoustic approach proposed by previous researchers for the element of straight pipe. Although the pipe between the perforated layers is a distributed element in the analogy, it has been treated as a parallel element by previous investigators. The analogy error is demonstrated by comparing the calculated absorption coefficients based on the parallel circuit and the distributed circuit, respectively, with the measured values by the two-microphone impedance tube method.

자기 변형 패치를 이용한 비자성 배관의 비접촉 종진동 모달 테스팅 (Non-contact Longitudinal Modal Testing of a Non-ferromagnetic Pipe Using Magnetostrictive Patches)

  • 박찬일;한순우;김윤영
    • 한국소음진동공학회논문집
    • /
    • 제18권3호
    • /
    • pp.293-298
    • /
    • 2008
  • Non-contact modal testing for longitudinal modes of a pipe is discussed in this work. The suggested method can generate and measure longitudinal vibrations without mechanical contact by using the coupling phenomenon between deformation and magnetic field, known as the magnetostrictive effect. This effect has been used to generate and measure ultrasonic waves, but seldom used to deal with audible vibrations. In this investigation, the validity of the developed method in a typical vibration frequency range is checked with an Inconel pipe being used in nuclear power plants.

배관에 의한 구조진동 진단 및 해결 사례 (A diagnosis and solution case of structural vibration caused by pipe)

  • 이정환;구동식;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1371-1374
    • /
    • 2007
  • A few intake stations have vibration problems caused by pipes. The vibration transffered from pipes excites building severely. Therefore, the crack is generated on building wall and people who work at intake station are damaged. In this paper, the vibration is measured and analysis is carried out for pipes at intake station in order to identify the usefulness and effectiveness of the solution proposed for pipe resonance avoidance. According to the result of analysis, bellows is reduced the vibration of pipes.

  • PDF

SH파 분산특성 변화를 이용한 배관 점진감육 진단 기법 (Gradual pipe wall thinning diagnosis through the variation of dispersion characteristics of SH waves)

  • 조승현;권휴상;안봉영;이승석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.258-259
    • /
    • 2009
  • Pipe wall thinning is one of severe problems on structural safety in nuclear power plants. A guided wave can be a proper tool for the fast evaluation or monitoring. As for gradual wall thinnings, however, low sensitivity caused by the low reflection coefficient limits the use of the guided wave. In this work, instead of the guided wave reflection at the wall thinning, the variation of dispersion characteristics is concerned. SH waves were employed due to several advantages and the magnetostrictive patch transducers were used for the excitation and sensing of the SH waves. The proposed method were verified with some experiments and showed the feasibility as an effective tool for the inspection of gradual wall thinning.

  • PDF

배기 소음기내를 전파하는 비정상 충격파의 수치해석 (Study of the Weak Shock Wave Propagating through an Exhaust Pipe Silencer System)

  • 권용훈;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.462-467
    • /
    • 2001
  • The present study addresses a computational work of the weak shock wave propagatings inside a silencer system of automobile exhaust pipe. Four different types of the silencer systems and the initial shock wave Mach number $M_s$ of $1.01\sim1.30$ are applied to investigate their effects on the noise reduction and the flow field in a silencer system. The results obtained from the present computational work are compared with the experimental results. The second order total variation diminishing (TVD) scheme is employed to solve the two dimensional, compressible, unsteady, Euler equations. The present computational results predict the experimental results with a quite good accuracy. Of the four silencer systems applied, the most desirable silencer system to reduce the peak pressure at the exit of the exhaust pipe is discussed.

  • PDF

가변속 왕복동형 압축기 본체의 동적 거동 해석 (Dynamic Behavior Analysis of Reciprocating Compressor Frame with Variable Rotating Speed)

  • 김태종;이상민;박찬수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.362-367
    • /
    • 2001
  • A reciprocating compressor unit with variable rotating speed driven by BLDC motor is mounted inside hermetic chamber on an internal suspension composed of 4 coil springs and a discharge pipe. A method for predicting the dynamic behavior of compressor frame is required to reduce the transmitted vibration level. Mechanical characteristics such as mass, spring and discharge pipe stiffness properties are obtained with experimentation. To confirm the vibration model for compressor frame, free vibration analyses are performed with theoretical and experimental methods. Results for analytical and experimental investigations on dynamic behavior of the compressor frame are presented, and the agreement between measured and predicted results are satisfactory.

  • PDF

등간격으로 배열된 마이크로폰을 이용한 관내 유량측정 방법 (A Method for the Measurement of Flow Rate in Pipe using a Microphone Array)

  • 김용범;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1667-1674
    • /
    • 2000
  • A new method is proposed to measure the flow rate in a pipe by multiple measurements of acoustic pressure using a microphone array. It is based on the realization that variation in flow velocity affects the change in wave number. The method minimizes measurement random errors and sensor mismatch errors thereby providing practically realizable flow rate measurement. One of the advantages of the method is that it does not obstruct the flow field and can provide the time-spatial mean flow rate. Numerical simulations and experiments were conducted to verify the utility of this method.