• 제목/요약/키워드: Pipe Flow Analysis

검색결과 638건 처리시간 0.028초

크랙을 가진 유체유동 회전 외팔 파이프의 안정성 해석 (Stability Analysis of Rotating Cantilever Pipe Conveying Fluid with Crack)

  • 손인수;윤한익;김동진
    • 한국소음진동공학회논문집
    • /
    • 제17권12호
    • /
    • pp.1161-1169
    • /
    • 2007
  • In this paper, the dynamic stability of a rotating cantilever pipe conveying fluid with a crack is investigated by the numerical method. That is, the influence of the rotating angular velocity, mass ratio and crack severity on the critical flow velocity for flutter instability of system are studied. The equations of motion of rotating cantilever pipe are derived by using extended Hamilton's principle. The crack section of pipe is represented by a local flexibility matrix connecting two undamaged pipe segments. The crack is assumed to be in the first mode of fracture and always opened during the vibrations. Generally, the critical flow velocity for flutter is proportional to the rotating angular velocity of a pipe. Also, the critical flow velocity and stability maps of the rotating pipe system for the variation each parameter are obtained.

개방형 구조의 진동형 히트파이프의 응축부 길이에 따른 추력 및 유동 가시화 (Thrust and Flow Visualization according to Length of Condenser Section of Open Pulsating Heat Pipe)

  • 손민재;최종욱
    • 한국가시화정보학회지
    • /
    • 제21권3호
    • /
    • pp.57-64
    • /
    • 2023
  • An open pulsating heat pipe operates continuously by inflow and outflow fluids through an open-type condenser. The open pulsating heat pipe is a device capable of obtaining the thrust due to the variation of internal pressure during phase change. Therefore, the open pulsating heat pipe is a suitable device to move fluids if the heat source such as waste heat exists. Many numerical studies have not been sufficiently conducted on the open pulsating heat pipe. In this study, the numerical analysis of the open pulsating heat pipe is performed according to the length of the condenser section. The OpenFOAM software is used to obtain the thrust and the flow visualization for the open pulsating heat pipe.

이젝터 구동관로의 직경비와 끝단의 위치 변화에 따른 유동특성 (Flow Characteristics of Ejector Driven Pipe According to the Changes of Diameter Ratio and End Position)

  • 김노형
    • 한국유체기계학회 논문집
    • /
    • 제19권1호
    • /
    • pp.45-51
    • /
    • 2016
  • This study conducted CFD analysis on the mean velocity vector of distribution of the ejector driven pipe while changing the inlet velocity to 1 m/s at the diameter ratio of diffuser of 1:3, 1:2.25, 1:1.8 with the end position of driven pipe at 1, 1.253, 1.333, 1.467 respectively, which used $k-{\varepsilon}$/High Reynolds Number for the turbulence model, SIMPLE method for the analysis algorithm, and PIV experiment to verify the CFD analysis. As a result of the CFD analysis the optimum diameter ratio of ejector driven pipe was 1:3, the optimum end position of driven pipe was 1.333 for the diameter ratio of 1:3, 1:2.25, 1:1.8 and the PIV experiment obtained the same result as the CFD analysis. Therefore, the numerical analysis of the flow characteristics of ejector can be used for the optimum design implementation on ejector system.

파이프유동장에 분사되는 제트의 유동특성 연구 (Flow characteristics of a cross jet issued in the fully developed pipe flow)

  • 김경천;신대식
    • 대한기계학회논문집B
    • /
    • 제22권7호
    • /
    • pp.927-936
    • /
    • 1998
  • In the fully developed pipe flow, when jet is injected in cross to the flow there are complex transition flows caused by interaction of the cross flow and jet. These interactions are studied by means of the flow visualization methods and frequency analysis using a hot-wire anemometer. The velocity range of cross flow of the pipe is 0.3 m/s ~ 1.2 m/s and the corresponding Reynolds number, R$\sub$p/, based on the pipe diameter is 2.25 * 10$\^$3/ ~ 9.02 * 10$\^$3/. The velocity ratio (R), jet velocity/cross flow velocity, is chosen from 2 to 10. A circular cylinder is placed in the pipe instead of jet to observe the vortex shedding from the solid body. To compare the jet and circular cylinder flow, the vortical structure is analyzed in both cases and the structure of vortices and the origin of its formation are investigated, especially. The vortex shedding of the dominant coherent structure is compared between the jet flow and the circular cylinder flow. In the case of the jet flow, the Strouhal numbers are different depending on the existence of the upright vortex as well as the velocity ratio (R).

Vortex-induced vibration characteristics of multi-mode and spanwise waveform about flexible pipe subject to shear flow

  • Bao, Jian;Chen, Zheng-Shou
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.163-177
    • /
    • 2021
  • Numerical simulations of the Vortex-Induced Vibration (VIV) about a large-scale flexible pipe subject to shear flow were carried out in this paper. Efficiency verification was performed firstly, validating that the proposed fluid-structure interaction solution strategy is competent in predicting the VIV response. Then, the VIV characteristics related to multi-mode and spanwise hybrid waveform about the flexible pipe attributed to shear flow were investigated. When inflow velocity rises, higher vibration modes are apt to be excited, and the spanwise waveform easily convertes from a standing-wave-dominated status to a hybrid standing-traveling wave status. The multi-mode or even multiple-dominant-mode is prone to occur, that is, the dominant mode is often followed by several apparent subordinate modes with considerable vibration energy. Hence, the shedding frequencies no longer obey Strouhal law, and vibration trajectories become intricate. According to the motion analysis concerning the coupled cross-flow and in-line vibrations, as well as the corresponding wake patterns, a tight coupling interaction exists between the structural deformation and the wake flow behind the flexible pipe. In addition, the evolution of the vortex tube along the pipe span and a strong 3D effect are observed due to the slenderness of the flexible pipe and the variability of the vortex shedding attributed to the shear flow.

나선형 파형강관에서의 유동특성 및 압력강하 예측 (Prediction of Flow Behavior and Pressure Drop of Spirally Corrugated Steel Pipe)

  • 박종학
    • 한국전산유체공학회지
    • /
    • 제9권2호
    • /
    • pp.18-22
    • /
    • 2004
  • Numerical investigation has been conducted to figure out flow behavior and pressure drop characteristics of spirally corrugated steel pipe which is widely used in civil, industrial and agricultural field owing to many advantages such as good corrosion resistance and durability, strength, easy and quick installation. Also the poly-ethylene coating spirally corrugated steel pipe has the long life under condition of sea water immerged. In the present study, flow behavior in the spirally corrugated pipe and influence of P/d/sub h/(ratio of wave pitch to hydraulic diameter) to pressure drop are investigated by CFD with various Reynolds number. And also friction factor is estimated by pressure drop obtained by flow analysis. According to computation results, the flow runs spirally up and down along the spiral corrugation in the vicinity of wall, but the effect of spiral corrugation disappears in core region of pipe. As P/d/sub h/ becomes small, more pressure drop occurs in spirally corrugated Pipe. Besides, friction factor augmentation becomes much larger as Re increases. In case of p/d/sub h/=0.38, Pressure drop and friction factor of spirally corrugated pipe are about four times larger than smooth pipe at Re: 1.46×10/sup 6/.

상수도 관망 유량관측 자료의 주성분 분석을 위한 분석기간의 설정 (Identifying an Appropriate Analysis Duration for the Principal Component Analysis of Water Pipe Flow Data)

  • 박수완;전대훈;정소연;김주환;이두진
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.351-361
    • /
    • 2013
  • In this study the Principal Component Analysis (PCA) was applied to flow data in a water distribution pipe system to analyze the relevance between the flow observation dates, which have the outliers of observed night flows, and the maintenance records. The data was obtained from four small size water distribution blocks to which 13 maintenance records such as pipe leak and water meter leak belong. The flow data during four months were used for the analysis. The analysis was carried out to identify an appropriate analysis period for a PCA model for a water distribution block. To facilitate the analyses a computational algorithm was developed. MATLAB was utilized to realize the algorithm as a computer program. As a result, an appropriate PCA period for each of the case study small size water distribution blocks was identified.

상수관망의 누수감지를 위한 주성분 분석의 적용 가능성에 대한 연구 (Study on the applicability of the principal component analysis for detecting leaks in water pipe networks)

  • 김기민;박수완
    • 상하수도학회지
    • /
    • 제33권2호
    • /
    • pp.159-167
    • /
    • 2019
  • In this paper the potential of the principal component analysis(PCA) technique for the application of detecting leaks in water pipe networks was evaluated. For this purpose the PCA was conducted to evaluate the relevance of the calculated outliers of a PCA model utilizing the recorded pipe flows and the recorded pipe leak incidents of a case study water distribution system. The PCA technique was enhanced by applying the computational algorithms developed in this study which were designed to extract a partial set of flow data from the original 24 hour flow data so that the effective outlier detection rate was maximized. The relevance of the calculated outliers of a PCA model and the recorded pipe leak incidents was analyzed. The developed algorithm may be applied in determining further leak detection field work for water distribution blocks that have more than 70% of the effective outlier detection rate. However, the analysis suggested that further development on the algorithm is needed to enhance the applicability of the PCA in detecting leaks by considering series of leak reports happening in a relatively short period.

LDV Measurement, Flow Visualization and Numerical Analysis of Flow Distribution in a Close-Coupled Catalytic Converter

  • Kim, Duk-Sang;Cho, Yong-Seok
    • Journal of Mechanical Science and Technology
    • /
    • 제18권11호
    • /
    • pp.2032-2041
    • /
    • 2004
  • Results from an experimental study of flow distribution in a close-coupled catalytic converter(CCC) are presented. The experiments were carried out with a flow measurement system specially designed for this study under steady and transient flow conditions. A pitot tube was a tool for measuring flow distribution at the exit of the first monolith. The flow distribution of the CCC was also measured by LDV system and flow visualization. Results from numerical analysis are also presented. Experimental results showed that the flow uniformity index decreases as flow Reynolds number increases. In steady flow conditions, the flow through each exhaust pipe made some flow concentrations on a specific region of the CCC inlet. The transient test results showed that the flow through each exhaust pipe in the engine firing order, interacted with each other to ensure that the flow distribution was uniform. The results of numerical analysis were qualitatively accepted with experimental results. They supported and helped explain the flow in the entry region of CCC.

배관망 내의 정상상태 유동 해석 (Steady-state flow analysis of pipe network)

  • 채은미;사종엽
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.281-291
    • /
    • 1999
  • A computer code based on a node equation method has been developed for the analysis of pipe network. Both data structure and object-oriented programming technique are used for pipe and node modelling, in which simplification process is applied to complicated and large pipe network. The semi-direct solver, ILU-CGS, improves greatly both the accuracy and the rate of convergence. The computational result of high-pressure pipe network of city gas in Taegu shows the good agreement with the real data.

  • PDF