• Title/Summary/Keyword: Pin joint

Search Result 172, Processing Time 0.023 seconds

Arthroscopic Reduction and Fixation of an Anterior Cruciate Ligament Avulsion Fracture From the Tibial Eminence Using Bioabsorbable Pins - Technical Note - (생흡수성 핀을 이용한 소아 경골 과간부 견열 골절의 관절경적 정복 및 고정 방법 - 수술 술기 -)

  • Lee, Su-Chan;Yang, Il-Soon;Seo, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.183-187
    • /
    • 2009
  • Purpose: We describe a new and simple technique for arthroscopic fixation of tibial intercondylar eminence avulsion fracture using bioabsorbable pins in skeletally immature patients. Operative Technique: Diagnostic knee arthroscopy is performed using anterolateral and anteromedial portals. Fracture debris and blood clot are debrided to expose the injured site well. The fragment is reduced with the probe and fixed temporarily with a 1.1-mm diameter K-wire that is inserted percutaneously from the anterosuperior aspect of the knee joint. The drill guide is introduced into the joint and the fragment is secured by bioabsorbable, poly-p-dioxanone 1.3-mm pins inserted from different angles. The pins are 40 mm in length. The knee is placed in a long leg cast in extension for 4 weeks to assure that full extension is obtained. Conclusion: Arthroscopic fixation of an tibial intercondylar eminence avulsion fracture using bioabsorbable pins is not a technically demanding, suitable method that ensures fracture healing and restores the stability of the joint.

  • PDF

Wear Resistance of Crosslinked Ultra-high Molecular Weight Polyethylene (가교된 초고분자량 폴리에틸렌의 내마모성)

  • Im, Chae-Ik;Lee, Gwi-Jong;Jo, Jae-Yeong;Choe, Jae-Bong;Choe, Gwi-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.99-106
    • /
    • 1999
  • Ultra-high molecular weight polyethylene (UHMWPE) was crosslinked in the melt state to enhance wear resistance, Dicumyl peroxide (DCP) and triallyl cyanurate (TAC) was used as a crosslinking agent and a promoter, respectively. With increasing amount of DCP and TAC used, gel content of crosslinked UHMWPE (XUMPE) increased, while the melting temperature, crystallizaiton temperature, crystallinity, and tensile properties decreased. The results of pin-on-disk wear test and ball-on-disk test with small applied load showed reduced wear volumes of XUMPE from that of the unmodified UHMWPE. As the wear mechanism effected in the experimental condition of this study was thought to be deformation rather than adhesion or fatigue, a new parameter, the ratio of maximum contact stress to yield stress, was proposed to correlate well with observed wear resistance. In ball-on-disk wear test with larger applied load, XUMPE showed higher wear volumes than that of the unmodified UHMWPE which were accompanied with increased friction coefficients and surface roughness of the wear tracks. When contact stress was well above yield stress, the failure of XUMPE, as well as deformation, was thought to be much accelerated.

  • PDF

ILIZAROV FIXATION FOR THE TYPE C TIBIAL PLAFOND FRACTURES (C형 경골천정 골절에 대한 일리자로브 외고정술)

  • Cho, Hyoun-Oh;Kwak, Kyoung-Duck;Cho, Sung-Do;Kim, Byung-Yong;Oh, Jang-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.1
    • /
    • pp.51-58
    • /
    • 1997
  • The purpose of this study is to evalute the efficacy af the Ilizarov external fixation for the surgical treatment. of the tibial plafond fractures. We reviewed retrospectively fourteen cases of tibial plafond fractures with moderate to severe soft. tissue damage, which were fixed with Ilizarov external fixator. Using the AO Muler classification, there were four Type C1 fractures, six Type C2 and four Type C3. In most, of the cases, the ankles were operated on with other associated fractures within a few days after injury. We reduced the fracture indirectly by soft issue taxis and fixed externally across the ankle joint. using the circular external fixator with tensioned wires and ankle hinge. In cases of inadequate closed reduction, we applied limited open reduction and internal fixation. Range of motion exercise began immediately. Postoperative follow-up averaged fourteen months (ranges, 8-30 months). Overall clinical results rated good or excellent in 7 cases, fair in 4 and poor in 3. There were three cases of pin tract infection which were resolved with short-term antibiotics and local care; one delayed wound closure in a patient. whose fracture was associated with Type III open wound; one wound slough in a patient associated with Type II open wound, which was closed later by skin graft; and one osteoarthritis. From this review, we concluded that cross-ankle circular external fixation with tensioned wires with or without. limited open reduction is a reasonable alternative for the treatment of the tibial plafond fractures with severe soft tissue damage.

  • PDF

Evaluation of The Moment Resistance of Reinforced Wooden Gusset to Glulam Joint (보강목질적층판이 사용된 집성재 접합부의 모멘트 저항성능 평가)

  • Lee, In-Hwan;Song, Yo-Jin;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.53-61
    • /
    • 2017
  • In this study, specimens were produced with a column member and a wooden gusset only by inserting an wooden gusset which is a substitute for steel plate into the center of a slit-processed column member. The moment resistance performance of the specimens was compared with that of control specimens that used a steel plate. The measured maximum moments of the specimens produced with GFRP-reinforced wooden laminated gussets and pins were lower by 24% on average compared to the steel plate-inserted specimens, but they showed good toughness. The fracture shape suggests that it was fractured along the annual rings between the pin and the end of the column member. The rigid specimen that integrated a laminated wood and a wooden laminated gusset with adhesive showed 2.8 times greater initial rigidity and 40% greater maximum moment on average compared to the control specimen. The rigid specimens mainly fractured on a glulam around glue line.

An experimental study of the behaviour of double sided welded plate connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • v.29 no.1
    • /
    • pp.1-22
    • /
    • 2018
  • Multi-storey precast concrete skeletal structures are assembled from individual prefabricated components which are erected on-site using various types of connections. In the current design of these structures, beam-to-column connections are assumed to be pin jointed. Welded plate beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under bending and shear loadings. The experimental work has involved the determination of moment-rotation relationships for semi-rigid precast concrete connections in full scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and weld arrangements conformed with successful commercial practice. Proprietary hollow core slabs were tied to the beams by tensile reinforcing bars, which also provide the in-plane continuity across the connections. The strength of the connections in the double sided tests was at least 0.84 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.7 to 3.9 times the flexural stiffness of the attached beam. When the connections were tested without the floor slabs and tie steel, the reduced strength and stiffness were approximately a third and half respectively. This remarkable contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. In general, the double sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided welded plate connection test results are presented in this paper. The behaviour of single sided welded plate connection test results is the subject of another paper.

Structural performance by strengthening types of wood frames using H shaped steel joints (H형강 접합부를 갖는 목조 골조의 보강형식에 따른 구조성능)

  • Kim, Soon-Chul;Moon, Youn-Joon;Yang, Il-Seung;Park, Geun-Hong
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.77-83
    • /
    • 2008
  • The effective mixture of structural laminated timber and other materials is expected to extend the potentials of building structures because of the potentials to realize high performance in structural safety. The classical joint types using drift pin and bolts are occurred local failures due to the small bearing area. In result, new joints using H shaped steel were suggested in this research. The objective of this study is to evaluate elasto-plastic behaviors by strengthening types of wood frames with new joints connecting structural laminated timber with H shaped steel. A total of five specimens of about one-second scale were tested. Specimens had columns with 1,050 height and $84mm{\times}100mm$ section, and a beams with 1,950mm length and $130mm{\times}100mm$ section. Also, the specimens were stiffened by brace, hwang-toh brick, and autoclaved lightweight concrete. The results of the test showed that the specimen stiffened with autoclaved lightweight concrete was characterized by fairly good strength and stiffness than those of the other specimens. Initial stiffness of H-2.0D-NS specimen with 2 times inserting length of beam height showed 1.33 times than that of H-1.5D-NS specimen. However, the strength of H-2.0D-NS specimen has not improved too much than H-1.5D-NS specimen.

Treatment of Infected Tibial Nonunion Combined with Soft Tissue Defect (Effectiveness of Simultaneous Free-tissue Transfer and Ilizarov Distraction Osteogenesis) (연부조직 결손을 동반한 감염성 경골 불유합 및 골결손의 치료(유리피판술과 동시에 시행한 Ilizarov기구를 이용한 골연장술의 유용성))

  • Song, June-Young;Jung, Heun-Guyn;Seo, Seung-Yong;Jang, Hyun-Ho
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.37-41
    • /
    • 2005
  • Purpose: The purpose of this study was to evaluate the effectiveness of internal transport using Ilizarov apparatus with free flap surgery for infected tibial nonunion. Materials and Methods: We reviewed 8 patients of infected tibial nonunion treated with internal transport using Ilizarov apparatus and free flap surgery. Seven of eight patients were available for at least 1 year follow-up. All patients were male. The mean age at the time of the surgery was All fractures were Gustilo's type III B open fracture. The mean length of the bone defect was 8.5 cm. All used flaps for covering the soft tissue defect were free rectus abdominis muscle flap. We evaluated bone and functional results with use of the Paley and Catagni's classification. And we classified the complication with use of the Paley's classification. Results: Acceptable length and solid union of bone was achieved in all cases. The mean size of the bone length was 7.2 cm. The mean healing index was 69.5 days/cm. All but one case needed bone graft at docking site. All flaps were survived. There was no recurrence of infection. According to Paley and Catagni's classification, all cases showed excellent or good results. Complications were pin tract infection in 3 cases, persistent pain in 2 cases and limitation of joint motion in 2 cases. Conclusion: Simultaneous free-tissue transfer and Ilizarov distraction osteogenesis was thought to be an attractive treatment modality for infected nonunion of the tibia.

  • PDF

PIII&D(Plasma Immersion Ion Implantation & Deposition) 공정으로 제조된 인공 관절용 NbN 박막코팅층의 특성 평가

  • Park, Won-Ung;Choe, Jin-Yeong;Jeon, Jun-Hong;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.349-349
    • /
    • 2011
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등으로 인하여 발생하는 관절의 손상 부위를 대체하기 위해 고안된 관절의 인공 대용물이다. 인공 관절 중 인공 고관절의 경우 관절 운동을 하는 라이너(Liner)와 헤드(Head) 부분이 인공관절의 수명을 결정하게 되는데, 헤드 부분에 메탈소재와 라이너 부분에 고분자 소재를 사용하는 MOP(metal on polymer) 구조의 인공관절은 충격흡수의 장점이 있는 반면 wear debris에 의한 골용해로 인하여 관절이 느슨해지는 문제점이 발생하여 재 시술의 주요 원인이 되고 있다. 현재 인공관절의 수명을 늘리기 위해 DLC, ZrO, TiN 등의 높은 경도 값을 갖는 박막을 금속헤드 위에 증착하여 상대재인 인공관절용 고분자 소재의 마모량을 줄이고자 하는 연구가 활발하게 진행되고 있다. 따라서 본 연구에서는 PIII&D(Plasma Immersion Ion Implantation & Deposition)공정을 이용하여 Co-Cr-Mo 합금 소재에 질소 이온을 주입 한 후 NbN 박막을 증착하여 상대재인 초고분자량 폴리에틸렌(UHMWPE)의 마모량을 줄이고자 하였다. NbN 박막의 특성을 평가하기 위해 XRD, XPS, AFM 등의 분석을 수행하였으며, 상대재인 초고분자량 폴리에틸렌의 마모량을 측정하기 위해 Pin-on-disk tribometer를 이용하여 마모 실험을 진행하였다. 마모 실험 결과, NbN 박막을 단순 증착한 경우, 현재 인공관절용 헤드(Head) 소재로 가장 널리 사용되고 있는 Co-Cr-Mo 합금에 비하여, 상대재인 초고분자량 폴리에틸렌의 마모량을 약 20% 감소시키는 것을 알 수 있었다. 또한, Co-Cr-Mo 합금 소재에 질소 이온주입을 하여 표면을 개질한 후, NbN 박막을 증착한 경우, 마모량이 최대 50%까지 감소하는 것을 확인할 수 있었다.

  • PDF

Surgical Correction of an Antebrachial Deformity with Severe External Rotation in Two Dogs (심각한 외측 회전을 동반한 전완 기형의 외과적 교정 치료 2 증례)

  • Yoon, Hun-Young;Roh, Mi-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.328-331
    • /
    • 2011
  • Two dogs presented to the Dueckso Animal Hospital with a history of intermittent lameness of the left forelimb. On physical examination, a visible antebrachial deformity that resulted in gross external rotation of approximately $90^{\circ}$ was observed in two dogs. Medial-lateral radiographic views revealed distal ulnar subluxation, cranial bowing of the radius, radial and ulnar shortening, and external rotation of the paw. A distal ulnar ostectomy and distal radial closing wedge osteotomy were performed in two dogs. A proximal ulnar osteotomy was performed, adjacent to the elbow joint in case 1. Then, the osteotomized site was supported with an intramedullary pin. A T-plate and cortical screws were applied to the proximal and distal radial segments after derotating the distal segment internally. Postoperative radiographic view verified the correction of the angular deformity in two dogs. The follow-up was completed by physical examination 6 and 10 months after surgery respectively. There was no evidence of lameness of the left forelimb in two dogs. Gross observation of the limb revealed an apparent appropriate correction of the rotational and angular deformity in two dogs.

Fault Detection through the LASAR Component modeling of PLD Devices (PLD 소자의 LASAR 부품 모델링을 통한 고장 검출)

  • Pyo, Dae-in;Hong, Seung-beom
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.314-321
    • /
    • 2020
  • Logic automated stimulus and response (LASAR) software is an automatic test program development tool for logic function test and fault detection of avionics components digital circuit cards. LASAR software needs to the information for the logic circuit function and input and output of the device. If there is no component information, normal component modeling is impossible. In this paper, component modeling is carried out through reverse design of programmable logic device (PLD) device without element information. The developed LASAR program identified failure detection rates through fault simulation results and single-seated fault insertion methods. Fault detection rates have risen by 3% to 91% for existing limited modeling and 94% for modeling through the reverse design. Also, the 22 case of stuck fault with the I/O pin of EP310 PLD were detected 100% to confirm the good performance.