Weldability of Al 7075 Alloy according to different tools and welding conditions by F.S.W (Al 7075의 마찰교반 용접부 특성에 관한 연구)

  • Jang Seok-Ki;Jeon Jeong-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.30-41
    • /
    • 2006
  • This paper shows mechanical Properties and behaviors of macrostructures for specimens welded by F.S.W according to welding conditions and tool dimensions with $6.35mm_t$ aluminum 7075-T651 alloy plate. It apparently results in defect-free weld zone in case transition speed was changed to 15mm/min 61mm/min and 124mm/min under conditions of tool rotation speed such as 800rpm. 1250rpm and 1600rpm respectively with tool's Pin diameter 40mm and 60mm. The optimum mechanical property, ultimate stress,${\sigma}_Y=470Mpa$ is obtained at the condition of 124mm/min of travel speed with 800rpm of tool rotation speed using full screw type pin. shoulder dia. $20{\phi}mm$ pin dia. $6{\phi}mm$ and pin length 6mm. The full-screw type and the half-screw type pin shows the similar behaviors of weldability. It is found that the size of nugget is depended on tool transition speed and tool dimension by macrostructures of the cross section of weld zone.

Weldability of Al 7075 Alloy according to different tools and welding conditions by F.S.W (Al 7075의 마찰교반 용접부 특성에 관한 연구)

  • Jang, Seok-Ki;Jeon, Jeong-Il
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.348-358
    • /
    • 2005
  • This paper showed mechanical properties and behaviors of macrostructures for specimens welded by F.S.W according to welding conditions and tool with 6.35$mm_t$ aluminum 7075-T651alloy plate. It resulted in defect-free weld zone in case tool rotation speed was 800rpm, 1250rpm and 1600rpm respectively that transition speed was changed to 15mm/min, 61mm/min and 124mm/min with tool's pin diameter 4${\Phi}$mm and 6${\Phi}$mm. The optimum mechanical property, ultimate stress,${\sigma}_Y$=470Mpa was obtained at the condition of 124mm/min of travel speed with 800rpm of tool rotation speed using full screw type pin, shoulder dia. 20${\Phi}$mm, pin dia.6${\Phi}$mm and pin length 6mm. The full-screw type and the half-screw type pin showed the similar behaviors of weldability. It is found that the size of nugget was depended on tool transition speed and tool dimension by macrostructures of the cross section of weld zone.

  • PDF

The Development of Pin Screws into the Bone for External Fixator (체외 고정구용 골 삽입 금속 나사 개발)

  • Choi, Y.C.;Rhee, K.M.;Na, W.H.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.5-17
    • /
    • 2009
  • We developed bone-insertion pin screw that can be used for purposed treatment by combining with the external fixator which is the subsidiary tool for the healing of the fracture (open fracture of long bone, reconstruction of soft tissue and arthrodesis etc.) Furthermore, for the frist time, we succeeded in domestic-producing this screw, using specially-designed treating tool stuck on the lathe machine and abrasive blasting machine, and the post-dealing technique and process. In comparison with other foreign products, we could get more desirable results in various tests. This pin screw has 103% characteristics of the average of foreign products. Thus we'd like to introduce design techniques, post-dealing process and result of function tests.

  • PDF

Pedicle Screw Placement in the Thoracolumbar Spine Using a Novel, Simple, Safe, and Effective Guide-Pin : A Computerized Tomography Analysis

  • Hyun, Seung-Jae;Kim, Yongjung J.;Rhim, Seung-Chul;Cheh, Gene;Cho, Samuel K.
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.1
    • /
    • pp.9-13
    • /
    • 2015
  • Objective : To improve pedicle screw placement accuracy with minimal radiation and low cost, we developed specially designed K-wire with a marker. To evaluate the accuracy of thoracolumbar pedicle screws placed using the novel guide-pin and portable X-rays. Methods : Observational cohort study with computerized tomography (CT) analysis of in vivo and in vitro pedicle screw placement. Postoperative CT scans of 183 titanium pedicle screws (85 lumbar and 98 thoracic from T1 to L5) placed into 2 cadavers and 18 patients were assessed. A specially designed guide-pin with a marker was inserted into the pedicle to identify the correct starting point (2 mm lateral to the center of the pedicle) and aiming point (center of the pedicle isthmus) in posteroanterior and lateral X-rays. After radiographically confirming the exact starting and aiming points desired, a gearshift was inserted into the pedicle from the starting point into the vertebral body through the center of pedicle isthmus. Results : Ninety-nine percent (181/183) of screws were contained within the pedicle (total 183 pedicle screws : 98 thoracic pedicle screws and 85 lumbar screws). Only two of 183 (1.0%) thoracic pedicle screws demonstrated breach (1 lateral in a patient and 1 medial in a cadaver specimen). None of the pedicle breaches were associated with neurologic or other clinical sequelae. Conclusion : A simple, specially designed guide-pin with portable X-rays can provide correct starting and aiming points and allows for accurate pedicle screw placement without preoperative CT scan and intraoperative fluoroscopic assistance.

Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note- (슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기-)

  • In Yong;Bahk Won-Jong;Park Jong-Beom;Hong Seung-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.60-63
    • /
    • 2002
  • Purpose : The purpose of this study was to introduce new femoral fixation technique using a cross-pin and a bioabsorbable interference screw in hamstring ACL reconstruction. Method : Semitendinosus and gracilis were harvested for quadrapled graft. After tibial tunnel had been made, femoral tunnel was made 35 mm in depth. Then the graft passed through the tunnels. Cross-pin was fixed through the drill hole which had been made through upper sleeve of the Rigidfix system. While pulling the graft, bioabsorbable interference screw was fixed through the anteromedial portal. Conclusion : We introduced the new femoral fixation technique using a cross-pin and a bioabsorbable interference screw as a good method with high fixation strength and tight graft-bone contact.

  • PDF

Experimental Study on the Friction and Wear of the Tribotreated Screw (스크류 소재의 마찰.마멸특성에 관한 실험적 연구)

  • 김청균;최동열;김성원;이종홍
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.382-391
    • /
    • 2001
  • This paper presents tribological results of the screw materials, which include the conventional screw and newly developed one. The tribotreated screw is manufactured by applying the polymer power to the heat treated surface of the screw. The injection pressure which is developed between the screw and the cylinder has been applied to the rubbing surface of the specimen in a pin-on-disk wear tester. The measured results show that the friction coefficient and wear rate of a tribotreated screw are low compared to the conventional one.

  • PDF

A Study on the Modeling of Screw Thread Limit Gauge using Automatic Design Program (자동설계 프로그램을 이용한 나사용 한계게이지 모델링에 관한 연구)

  • 김태호;김민주;이승수;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.595-599
    • /
    • 2002
  • In this study, we try to develop the 3D automatic design program of screw thread limit gauge. When users, who have some mechanical information, input some date, they can do 3D-modeling easily like expert. This is one of the merit in automatic design program and the automatic design program can compare screw thread limit gauge made in this study with processed the bolt and nut model. This demonstrates the effective value of automatic design model. Screw thread limit gauge of sort divide into ring gauge of measuring bolt and pin gauge of measuring nut. The new created automatic design program follows the KS.

  • PDF

Usefulness of Treatment with 6.5 mm Cancellous Screw and Steinmann Pin Fixation for Calcaneal Joint Depression Fracture (종골의 관절 함몰 골절에서 6.5 mm 해면골 나사와 Steinmann 핀을 이용한 치료의 유용성)

  • Lee, Gi-Soo;Kang, Chan;Hwang, Deuk-Soo;Noh, Chang-Kyun;Lee, Gi-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • Purpose: To report the radiographic and clinical results of 6.5 mm cancellous full threaded buttress screw or Steinmann pin fixation to maintain a reduction of calcaneal posterior facet depression fracture. Materials and Methods: From June 2009 to June 2012, 50 consecutive cases with calcaneal joint depression fracture that underwent open reduction and screw or pin fixation were enrolled in this study. A 6.5 mm cancellous full threaded screw was inserted from the posteroinferior aspect of the calcaneal tuberosity to the posterior facet (group A) or Steinman pin was inserted from the posterosuperior aspect of the calcaneal tuberosity to the calcaneocuboidal joint (group B). Both preoperative and postoperative Bohler and Gissane angles were measured radiographically, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale on the final follow-up were assessed. Results: The mean age of patients was 44.1 years, and the mean follow-up period was 27.2 months. According to the Sanders classification, 28 cases were type II and 22 cases were type III. In Sanders type II, Bohler and Gissane angles improved significantly from $10.1^{\circ}$ and $126.2^{\circ}$ preoperatively to $27.2^{\circ}$ and $117.1^{\circ}$, respectively, in the immediate postoperative radiograph, and at the final follow-up, $26.6^{\circ}$ and $118.6^{\circ}$, respectively. In Sanders type III, Bohler and Gissane angles improved significantly from $5.0^{\circ}$ and $129.8^{\circ}$ to $29.9^{\circ}$ and $119.3^{\circ}$, respectively, in the immediate postoperative radiograph, and $26.9^{\circ}$ and $120.2^{\circ}$ at the final follow-up. All cases achieved bony union, and the average period until complete union was 13.3 weeks. AOFAS ankle-hindfoot scale was 82.6 in Sanders type II and 77.3 in Sanders type III at the final follow-up. Conclusion: A 6.5 mm cancellous full threaded buttress screw or Steinman pin fixation is a noninvasive treatment method with a merit of being able to maintain the bearing capacity of the posterior facet comparable to plate fixation.

The Posterior Cruciate Ligament (PCL) Reconstruction by the Transtibial Tunnel Method using Cadaveric Achilles Tendon Grafts - Evaluation of the Initial Lengthening and the Slippage Ratio due to the Interference Screw Fixation and Double Cross-Pin Fixation - (사체 아킬레스건을 이용한 경골관통터널방식의 후방십자인대 재건술 - 간섭나사 및 이중고정핀 방식에 따른 초기연신 및 활주율 평가 -)

  • Kim, Cheol-Woong;Bae, Ji-Hoon;Oh, Dong-Joon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.4
    • /
    • pp.430-439
    • /
    • 2009
  • Posterior Cruciate Ligament (PCL) plays an important role in knee extension. Rotational instability due to injured PCL can be restored by various PCL reconstruction methods. In this study, the initial lengthening affected by fixation device and location was demonstrated, and furthermore, the slippage and the relationship between lengthening ratio and slippage ratio in the calcaneus and soft tissue fixation methods was newly suggested. Eight specimens of proximal tibia and Achilles tendon grafts were harvested from four cadavers and divided into four groups in regard to the four different types of transtibial fixation techniques. The cyclic load ranged from 50 N to 250 N applied to each graft fixed to proximal tibia in 55 degrees. The initial lengthening ratio to the total elongation has been approximately constant regardless of the fixation methods. The soft tissue fixation method with an interference screw showed about 56.4% slippage ratio to the total elongation and the same method with a double cross-pin presented about 45.4% slippage ratio. The soft tissue fixation method with an interference screw demonstrated approximately 2 mm less total elongation and about 13% more slippage than lengthening because of poor fixation compared to the same method with a double cross-pin.

Experimental Study on the Friction and Wear of Tribotreated Screw (스크류 소재의 마찰ㆍ마멸특성에 관한 실험적 연구)

  • 김청균;김성원;박균명
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.24-30
    • /
    • 2002
  • The friction/wear testing has been carried out for investigating the tribological characteristics between a conventional screw and tribotreated one. The tribotreated screw is manufactured by blasting a fine polymer power to the heat-treated surface of the conventional screw. The injection molding pressure that is developed between the screw and the cylinder has been applied to the rubbing surface on the specimen in a pin-on-disk wear tester. The measured results show that the friction coefficient and wear rate of a tribotreated screw are relatively low compared with the conventional one. This means that the tribotreated screw may be recommended for using an injection mold machine.