• Title/Summary/Keyword: Pim-3

Search Result 84, Processing Time 0.023 seconds

Performance effectiveness of pediatric index of mortality 2 (PIM2) and pediatricrisk of mortality III (PRISM III) in pediatric patients with intensive care in single institution: Retrospective study (단일 병원에서 소아 중환자의 예후인자 예측을 위한 PIM2 (pediatric index of mortality 2)와 PRIMS III (pediatric risk of mortality)의 유효성 평가 - 후향적 조사 -)

  • Hwang, Hui Seung;Lee, Na Young;Han, Seung Beom;Kwak, Ga Young;Lee, Soo Young;Chung, Seung Yun;Kang, Jin Han;Jeong, Dae Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1158-1164
    • /
    • 2008
  • Purpose : To investigate the discriminative ability of pediatric index of mortality 2 (PIM2) and pediatric risk of mortality III (PRISM III) in predicting mortality in children admitted into the intensive care unit (ICU). Methods : We retrospectively analyzed variables of PIM2 and PRISM III based on medical records with children cared for in a single hospital ICU from January 2003 to December 2007. Exclusions were children who died within 2 h of admission into ICU or hopeless discharge. We used Students t test and ANOVA for general characteristics and for correlation between survivors and non-survivors for variables of PIM2 and PRISM III. In addition, we performed multiple logistic regression analysis for Hosmer-Lemeshow goodness-of-fit, receiver operating characteristic curve (ROC) for discrimination, and calculated standardized mortality ratio (SMR) for estimation of prediction. Results : We collected 193 medical records but analyzed 190 events because three children died within 2 h of ICU admission. The variables of PIM2 correlated with survival, except for the presence of post-procedure and low risk. In PRISM III, there was a significant correlation for cardiovascular/neurologic signs, arterial blood gas analysis but not for biochemical and hematologic data. Discriminatory performance by ROC showed an area under the curve 0.858 (95% confidence interval; 0.779-0.938) for PIM2, 0.798 (95% CI; 0.686-0.891) for PRISM III, respectively. Further, SMR was calculated approximately as 1 for the 2 systems, and multiple logistic regression analysis showed ${\chi}^2(13)=14.986$, P=0.308 for PIM2, ${\chi}^2(13)=12.899$, P=0.456 for PRISM III in Hosmer-Lemeshow goodness-of-fit. However, PIM2 was significant for PRISM III in the likelihood ratio test (${\chi}^2(4)=55.3$, P<0.01). Conclusion : We identified two acceptable scoring systems (PRISM III, PIM2) for the prediction of mortality in children admitted into the ICU. PIM2 was more accurate and had a better fit than PRISM III on the model tested.

The IM Model of 3 Port RF Passive Component (3 포트 RF 수동부품의 IM 모델)

  • 차영찬;이진택;양기덕;조영송;김상태;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.7
    • /
    • pp.692-698
    • /
    • 2003
  • This paper presents IM model which is produced in 3 port RF passive component. We calculated forward and reflect PIM of 3 port component by using the model. And they are reasonable agreement with measurement result like below. In the case of forward IM, calculated result is -122 dBc(at 43 dBm), which differ 2.5 dB with measurement result. And reflected IM, the average calculated result is -130 dBc(at 43 dBm), which differ 3 dB with measurement result. The results which are calculated and measured under various condition(IM source level, frequency sweep, contour length, etc.) show that forward method gets more fixed result than that of reflect. Consequently, PIM of 3 port component is predicted and analyzed for desensitizing by the proposed model.

A PIM/PSM Component Modeling Technique Based on 2+1 View Integrated Metamodel (2+1 View 통합 메타모델 기반 PIM/PSM 컴포넌트 모델링 기법)

  • Song, Chee-Yang;Cho, Eun-Sook
    • The KIPS Transactions:PartD
    • /
    • v.16D no.3
    • /
    • pp.381-394
    • /
    • 2009
  • As a technique to enhance reusability for the created artifacts in software modeling process, the model driven method such like MDA has been applied. Unfortunately, the hierarchical and systematic MDA based development technique using UML is poor yet. This causes the problem that the MDA modeling with high consistency and reusability based on MDA metamodel is not being realized. To solve this problem, this paper proposes a MDA (PIM/PSM) component modeling technique using 2+1 view integrated metamodel. At first, the meta-architecture view model which can represents development process view and MVC view is defined. Then, the hierarchical integrated metamodels per view are addressed separately for modeling process and MVC at metamodel level on the hierarchy of the defined meta-architecture view model. These metamodels are defined hierarchically by layering the modeling elements in PIM and PSM pattern for UML models and GUI models. Appling the proposed metamodel to an ISMS application system, it is shown as a component modeling case study based on MDA. Through this approach, we are able to perform a component model with consistency and hierarchy corresponding to development process and MVC way. Accordingly, this may improve more independence and reusability of model.

Oxidation of Fe-(5.3-29.8)%Mn-(1.1-1.9)%Al-0.45%C Alloys at 550-650 ℃

  • Park, Soon Yong;Xiao, Xiao;Kim, Min Ji;Lee, Geun Taek;Hwang, Dae Ho;Woo, Young Ho;Lee, Dong Bok
    • Corrosion Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.53-61
    • /
    • 2022
  • Alloys of Fe-(5.3-29.8)%Mn-(1.1-1.9)%Al-(0.4-0.5)%C were oxidized at 550 ℃ to 650 ℃ for 20 h to understand effects of alloying elements on oxidation. Their oxidation resistance increased with increasing Mn level to a small extent. Their oxidation kinetics changed from parabolic to linear when Mn content was decreased and temperature was increasing. Oxide scales primarily consisted of Fe2O3, Mn2O3, and MnFe2O4 without any protective Al-bearing oxides. During oxidation, Fe, Mn, and a lesser amount of Al diffused outward, while oxygen diffused inward to form internal oxides. Both oxide scales and internal oxides consisted of Fe, Mn, and a small amount of Al. The oxidation of Mn and carbon transformed γ-matrix to α-matrix in the subscale. The oxidation led to the formation of relatively thick oxide scales due to inherently inferior oxidation resistance of alloys and the formation of voids and cracks due to evaporation of manganese, decarburization, and outward diffusion of cations across oxides.

Development of Dental Scaler Tip Mold with Powder Injection Molding Process

  • Hwang, C.J.;Ko, Y.B.;Park, H.P.;Chung, S.T.;Rhee, B.O.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.499-500
    • /
    • 2006
  • With the capability of net shaping for complex 3D geometry, powder injection molding (PIM) is widely used for automotive parts, electronics and medical industry. In this study, an ultrasonic dental scaler tip produced by machining process was redesigned for the PIM process. An injection mold was designed and machined to produce the dental scaler tip by the PIM process.

  • PDF

Risk Factors of Potentially Inappropriate Medications and Cost by Polypharmacy among Elderly Patients of a Community Pharmacy near a Top Tier General Hospital (상급종합병원 근처의 한 지역약국 처방전 분석에 의한 노인 환자의 다약제복용과 약제비용 및 잠재적으로 부적절한 약물사용 관련 위험인자)

  • Kim, Aram;Kim, Hong Ah;Rhie, Sandy Jeong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.25 no.3
    • /
    • pp.159-165
    • /
    • 2015
  • Objective: Polypharmacy is one of the main causes of inappropriate medication use, adverse drug-related events and cost. It aimed to investigate the status of polypharmacy and potentially inappropriate medication (PIM), the factors affecting polypharmacy and cost in elderly outpatients. Method: A pharmacy claim data were retrospectively analyzed with elderly patients prescriptions at a pharmacy located near a top tier general hospital. The numbers of medications per person, prevalence of polypharmacy and PIM according to the 2012 Beers criteria and Korea PIM list, medication cost and the factors affecting polypharmacy were investigated. Results: Forty-six percentages of the elderly outpatients received polypharmacy and over 21% of them had medications listed in Beers or Korean PIM. In multiregressional analysis, we found that age, gender and insurance types were affective factors of polypharmacy. (p < 0.001, 0.047, 0.009, respectively). The cost of polypharmacy with PIM in elderly outpatients was increased with age. Various approaches of interventions would be further required.

Determination of Loxoprofen Adsorption Isotherms by Frontal Analysis and Pulse Input Method (Frontal Analysis와 Pulse Input Method를 이용한 Loxoprofen의 등온흡착식 결정)

  • Lee, Eun;Park, Joon-Sub;Kim, In-Ho
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.371-375
    • /
    • 2006
  • Frontal analysis(FA) and Pulsed input method(PIM) have been frequently utilized to measure isotherm of single solute, as well as non-competitive isotherms of two solutes in chromatography(1). FA and PIM were used in this study as complementary methods to measure adsorption isotherms of loxoprofen racemate in HPLC. Prior to FA and PIM experiments, measurements of loxoprofen solubility were made at hexane/ethanol=50/50, 80/20, 95/5(v/v) with acetic acid(0.5%) for adjusting pH. The last composition(95/5) of hexane/ethanol allows us to separate loxoprofen racemate into two forms(retentate, extract). PIM and FA were used to determine the isotherms of re-and ex-loxoprofen.

Properties of TiN Thin Films Synthesized with HiPIMS and DC Sputtering (HiPIMS와 DC 스퍼터링으로 제조한 TiN 박막 특성)

  • Yang, Ji-Hun;Byeon, In-Seop;Kim, Seong-Hwan;Jeong, Jae-In
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.93-93
    • /
    • 2017
  • 고전력 펄스 전원공급장치를 이용한 마그네트론 스퍼터링(high-power impulse magnetron sputtering; HiPIMS)과 직류(direct current; DC) 전원공급장치를 이용한 마그네트론 스퍼터링(DC 스퍼터링)을 이용하여 제조한 티타늄 질화물(titanium nitride; TiN) 박막의 특성을 비교하였다. HiPIMS와 DC 스퍼터링 공정 중에 빗각증착을 적용하여 TiN 박막의 미세구조와 기계적 특성의 변화를 확인하였다. TiN 박막을 코팅하기 위한 기판으로 스테인리스 강판(SUS304)과 초경(cemented carbide; WC-10wt.%Co)을 사용하였다. 기판은 알코올과 아세톤으로 초음파 처리를 실시하여 기판 표면의 불순물을 제거하였다. 기판 청정 후 진공용기 내부의 기판홀더에 기판을 장착하고 $2.0{\times}10^{-5}torr$의 기본 압력까지 진공배기를 실시하였다. 진공 용기의 압력이 기본 압력에 도달하면 아르곤(Ar) 가스를 진공용기 내부로 ${\sim}10^{-2}torr$의 압력으로 주입하고 기판홀더에 라디오 주파수(radio frequency; rf) 전원공급장치를 이용하여 - 800 V의 전압을 인가하여 글로우 방전을 발생시켜 30 분간 기판 표면의 산화막을 제거하는 기판청정을 실시하였다. 기판청정이 완료되면 기본 압력까지 진공배기를 실시하고 Ar과 질소($N_2$)의 혼합 가스를 진공용기 내부로 ${\sim}10^{-3}torr$의 압력으로 주입하여 HiPIMS와 DC 스퍼터링으로 TiN 박막 제조를 실시하였다. 빗각의 크기는 $45^{\circ}$$-45^{\circ}$이었다. 제조된 TiN 박막은 주사전자 현미경, 비커스 경도 측정기 그리고 X-선 회절 분석기를 이용하여 특성을 분석하였다. HiPIMS로 제조한 TiN 박막은 기판 전압을 인가하지 않아도 색상이 노란색을 보이지만, DC 스퍼터링으로 제조한 TiN 박막은 기판 전압을 인가하지 않으면 노란색을 보이지 않고 어두운 갈색에 가까운 색을 보였다. TiN 박막의 경도는 HiPIMS로 제조한 TiN 박막이 DC 스퍼터링으로 제조한 TiN 박막보다 높았다. 이러한 TiN 박막의 특성 차이는 DC 스퍼터링과 비교하여 높은 HiPIMS의 이온화율에 의한 결과로 판단된다. 빗각을 적용한 TiN 박막은 미세구조 변화를 보였으며 이러한 미세구조 변화는 TiN 박막의 특성에 영향을 미치는 것을 확인하였다.

  • PDF

A UML Profile for Specifying Component Design as MDA/PIM (컴포넌트 설계를 MDA/PIM으로 명세하기 위한 UML프로파일)

  • Min Hyun Gi;Kim Soo Dong
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.3
    • /
    • pp.153-162
    • /
    • 2005
  • Component Based Development (CBD) is appealing as a technology to improve the productivity of software development through component reuse. Model Driven Architecture (MDA) is a new development paradigm which automatically generates application by transforming design models incrementally. Since both reusability of CBD and model transformation of MDA increase software productivity. integration of two technologies is desirable. To enable this technology integration, we need to devise a UML profile for specifying component design as a PIM. In this paper, we first define a meta-model for components, and propose a UML profile which is used to specify elements of component design as PIM. Since the proposed profile is based on Meta Object Facility (MOF) from which is MDA is derived, it is consistent and compatible with existing MDA methods and tools.

Genetic Algorithm Based Design Optimization of a Six Phase Induction Motor

  • Fazlipour, Z.;Kianinezhad, R.;Razaz, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1007-1014
    • /
    • 2015
  • An optimally designed six-phase induction motor (6PIM) is compared with an initial design induction motor having the same ratings. The Genetic Algorithm (GA) method is used for optimization and multi objective function is considered. Comparison of the optimum design with the initial design reveals that better performance can be obtained by a simple optimization method. Also in this paper each design of 6PIM, is simulated by MAXWELL_2D. The obtained simulation results are compared in order to find the most suitable solution for the specified application, considering the influence of each design upon the motor performance. Construction a 6PIM based on the information obtained from GA method has been done. Quality parameters of the designed motors, such as: efficiency, power losses and power factor measured and optimal design has been evaluated. Laboratory tests have proven the correctness of optimal design.