• 제목/요약/키워드: Pilot drill

검색결과 17건 처리시간 0.023초

내부냉각(內部冷却) 골천공시(骨穿孔時) 냉각수(冷却水)의 온도(溫度)에 따른 골조직(骨組織)의 병리조직학적(病理組織學的) 변화(變化) (HISTOPATHOLOGIG CHANGES OF THE BONE ON DRILLING WITH DIFFERENT TEMPERATURE SALINE USING INTERNAL IRRIGATION)

  • 박상준;김태규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권3호
    • /
    • pp.8-22
    • /
    • 1990
  • This study was performed to evaluate the histopathologic changes of the rabbit tibial compact bone using internal irrigation with both cold and room - temperature saline on drilling. The medial surface of the rabbit tibia was drilled with specially designed pilot drill (2.0mm in diameter) at 300 rpm. When drilling, two different temperature salines were injected (experimental group I : $4^{\circ}C$ saline, experimental goup Ⅱ : room - temperature saline). And the control group was drilled without cooling agent. The three rabbits in each two experimental and control groups were sacrificed 1, 2, 4, and 8 weeks after. The bone tissues including the bony defects were fixed with 10% neurtal buffered formalin, decalcified with formic acid, embedded in paraplast, and sterile sectioned at 5-6${\mu}m$. And then tissue specimens were stained with H - E and observed under light microscope. The results were as follow : The experimental groups showed early bone repair than the control group at all intervals. They underwent the same course of bone repair until 4 weeks. But the experimental group I showed slightly better bone maturation than the experimental group Ⅱ at 8 weeks.

  • PDF

TBM 터널을 이용한 이방향 천공 발파공법의 3차원 동적해석 (Three Dimensional Dynamic Analysis of Newly Developed Drill and Blast Method with Bi-directions using TBM Pilot Tunnels)

  • 이찬우
    • 전산구조공학
    • /
    • 제8권1호
    • /
    • pp.30-38
    • /
    • 1995
  • 이방향 천공 발파공법의 실용성을 입증하여 실시공에 착수하기 위해서는 수치해석을 통하여 사전에 종방향 및 방사방향 천공발파에 따른 지표면에서의 지반진동의 영향을 알아보는 것이 필요하였다. 정확한 현장조건과 발파하중이 주어진 상태에서의 정밀해를 구하기 위해서는 시공상의 발파패턴대로 전체 발파공을 모형화하는 것이 필요하나 앞서 언급한 바와 같이 해석목적상 기존공법과 신공법의 지반응답의 차이를 비교하는 것이 주목적이였기 때문에 해석조건을 동일하게 가정하고 발파공도 대표적인 방향성을 가지는 1개공만을 선택하여 해석을 수행하였다. 기존 종방향 천공 발파공법과 신공법인 이방향 천공 발파공법의 상대적 비교를 위한 3차원 동적 해석결과, 관심의 대상이 되는 터널 직상부의 경우 기존의 종방향 천공 발파에 비해 이방향 천공발파는 진동이 두드러지게 감소함을 알 수 있었으며 이는 발파공의 방향성에 따라 지반응답이 크게 영향을 받는다는 것을 의미한다. 따라서 터널굴착시 문제시 되는 지상구조물의 위치에 따라 발파공의 위치를 적절히 조절함으로써 문제발생 예상지역의 진동치를 감소시킬 수 있을 것이라 판단된다. 그러나 이러한 잇점은 확대발파전 파이롯트 터널이라는 자유공간이 존재할 때만 가능하므로 이방향 천공 발파공법은 TBM의 효용성을 극대화시킨 것이라 할 수 있다.

  • PDF

치과 임플랜트 식립시 관주에 따른 골 천공 기구의 열 발생에 관한 연구 (A STUDY ON THE HEAT GENERATION OF BONE DRILLING BURS ACCORDING TO IRRIGATION DURING IMPLANTATION OF DENIAL IMPLANT)

  • 문은수;임헌송;조인호
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.433-453
    • /
    • 1999
  • There are a lot of elements affecting the success of implant prosthesis. The quality of surgical procedure is considered as one of the key factors. To avoid the excess heat generation is an important element of successful osseointegration and it can be achieved by using a gentle surgical technique with a sharp instrument in bone drilling. This study was performed to measure and analyze comparatively the heat transmitted to sur-rounding bone at a distance of 0.5mm from the periphery of the drill hole in each drilling stage. The results were as follows. In standard system, the temperature of surrounding bone tissue ranged from $29.2^{\circ}C\;to\;48.3^{\circ}C$ with irrigation and from $34.6^{\circ}C\;to\;84.3^{\circ}C$ without irrigation. And in wide system, the temperature of surrounding bone tissue ranged from $29.5^{\circ}C\;to\;52.5^{\circ}C$ with irrigation and from $34.8^{\circ}C\;to\;87.8^{\circ}C$ without irrigation. And the temperature ranges exceeded the threshold without irrigation, while showing less than the threshold by the cooling effect of irrigation. In comparing standard system with wide system, although there was no significant difference, ${\phi}4.3mm$ pilot and ${\phi}4.3mm$ twist drill of wide system showed high value and wide system showed slightly high elevation of temperature in all depth in fixture installation. In the finite element analysis, the calculated value by the Fourier's cooling law were applied to the bone drilling surface. And through analysis using different irrigation temperatures at $28^{\circ}C,\;15^{\circ}C\;and\;5^{\circ}C$, and according to the time. The result was that the cooling water at least below $15^{\circ}C$ was required to maintain the temperature of surrounding bone less than threshold in bone drilling, the cooling water below $5^{\circ}C$ was required to gain more sufficient cooling effect, and cooling over 5 seconds was needed after bone drilling for sufficient effect.

  • PDF

CAD-CAM assisted flapless 수술법으로 식립된 임플란트의 안정성 : 기초연구 (Implant stability installed with CAD-CAM assisted flapless surgery : A pilot study)

  • 박찬진;김대곤;조리라
    • 구강회복응용과학지
    • /
    • 제27권4호
    • /
    • pp.405-413
    • /
    • 2011
  • CAD-CAM기법과 CT의 도움으로 무판막임플란트 치료술식이 가능하게 되었다. 본 연구의 목적은 1년간 전향적 연구를 통해 이러한 술식의 신뢰성을 검토하고자 하였다. 하악무치악상태의 연속적인 환자 12명이 포함되었다. 71개의 임플란트가 이공사이에 $NobelGuide^{TM}$법을 이용하여 식립되었고 환자는 정해진 주기에 따라 검사되었다. 한 개의 임플란트가 조기실패하였으며 나머지는 만족할 만한 기능을 보였다. 연구기간 중 평균적인 변연골흡수량은 중앙부($0.3{\pm}0.1$ mm), 견치부($0.5{\pm}0.1$ mm), 원심부($0.7{\pm}0.2$ mm)였으며 임플란트 안정성 수치의 변화량은 중앙부($-1.05{\pm}2.76$ mm), 견치부($-0.85{\pm}2.59$ mm), 원심부($-1.27{\pm}2.18$ mm)를 나타내었고 위치간 통계학적인 차이는 없었다(P>.05). 본 전향적인 기초조사연구에서 CAD-CAM기반의 무판막임플란트 치료술식은 하악무치악환자에게 신뢰성 있는 술식이 될 수 있을 것으로 사료되었다.

지반절삭 전기에너지를 활용한 회전굴착토크 예측에 관한 연구 (A Study for Predicting Rotational Cutting Torque from Electrical Energy Required for Ground Drilling)

  • 최창호;조진우;이용수;정하익;박용부
    • 한국지반공학회논문집
    • /
    • 제23권7호
    • /
    • pp.57-64
    • /
    • 2007
  • 본 연구는 지반의 회전굴착에 필요한 굴착 토크(torque)를 회전 오거 구동에 소요되는 전기에너지를 활용하여 예측할 수 있는 방법을 제시한다. 지반회전굴착은 선굴착 말뚝 시공, 연약지반 개량을 위한 소일-시멘트 그라우팅(soil-cement grouting), 사전 지반조사 등 지반공학 분야에 흔히 사용되고 있다. 오거를 통한 회전굴착에 소요되는 전기에너지와 회전 토크의 상호 관계를 이해하기 위하여 소형 실내 실험기기를 제작하고 파일럿(pilot)실험을 수행하였다. 실험기기는 직경 $D=5{\sim}10mm$의 일반 드릴 비트를 회전하여 CBR몰드에 다짐 제작된 토사공시체를 굴착할 수 있도록 설계되었다. 드릴 비트는 감속기어를 통하여 19RPM의 정격 속도로 회전하며, 구동 모터는 25Watt 용량의 교류 유도 전동기이다. 드릴 비트로 공시체를 회전 절삭하며 구동 모터에 소요되는 전류의 증가량과 실제 비트에 작용하는 토크(torque)를 측정하였고, 선형 회귀분석을 통하여 전류 증가량과 토르크 증가량의 상호관계를 파악하였다. 구하여진 회귀분석 결과를 활용하여 굴착시 소요되는 전류 증가량으로부터 굴착토크를 예측하여 계측된 토크값과 비교하였다. 비교로부터 굴착에 소요되는 전기력을 활용하여 굴착토크를 예측할 수 있다는 결론을 얻었으며, 이로부터는 굴착 전기력의 분석을 통해 지반의 전단강도 특성을 예측할 수 있음을 증명하고자 하였다.

건공화 공법의 발파 성능 평가를 위한 현장 시험에 관한 연구 (A Study of a Pilot Test for a Blasting Performance Evaluation Using a Dry Hole Charged with ANFO)

  • 이승훈;정성훈;최형빈
    • 대한토목학회논문집
    • /
    • 제42권2호
    • /
    • pp.197-208
    • /
    • 2022
  • 암반층이 얕은 깊이에서 출현하는 국내 지층 조건과 지하 공간의 활용도 증가로 인해서, 발파에 의한 굴착은 여전히 이용되고 있다. 발파 천공 이후에 존재하는 물이 있는 조건에서 실시되는 표준 발파는 폭굉압력 감소, 일정 장약량 사용, 디커플링과 같은 기술적인 어려움이 있다. 하지만, 기존의 표준 발파 공법을 대체할 만한 공법이 없는 실정이다. 본 논문에서는 건공화 펌프 시스템을 이용하여, 천공 내부에 존재하는 물을 제거하는 건공화 ANFO (Ammonium Nitrate Fuel Oil) 발파와 발파 성능의 비교를 위해서 추가적으로 표준 발파를 수행하였다. 각각의 발파 공법에서 계측된 진동 속도 데이터들과 환산거리의 함수로 이루어진 경험적인 발파진동 추정식을 이용하여, 최소제곱법에 의한 선형회귀분석을 실시하고, 궁극적으로 발파 성능을 정량적으로 분석하였다. 그 결과, 건공화 ANFO 발파에서 진동 감쇠가 더 크게 발생하고, 암반 파쇄에 더 많은 에너지를 소비하여, 더 가까운 거리에서 진동 허용 기준을 만족하는 진동 속도를 보였다. 또한, 표준 발파의 발파 진동 영향권이 건공화 ANFO 발파보다 더 멀리 있고, 발파 패턴의 범위가 더 넓은 것으로 나타났다. 본 연구에서 수행된 현장 발파 실험 결과로부터, 건공화 ANFO 발파 공법의 발파 성능이 효율적임을 확인하였다.

Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교 (Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants)

  • 박효상;슈엔;정성화
    • 대한치과교정학회지
    • /
    • 제36권4호
    • /
    • pp.295-307
    • /
    • 2006
  • 이 연구의 목적은 교정용 고정원으로 사용된 self-drilling과 self-tapping microscrew implants를 조직학적 및 생역적으로 비교하는 것이다. 28 마리의 가토에 112개의 microscrew implants (56개의 self-drilling microscrew implants 와 56개의 self-tapping microscrew implants)를 식립하였다. Self-tapping microscrew implants는 0.9 mm 드릴로서 홈을 형성한 후 식립하였고 self-drilling microscrew implants는 홈을 형성하지 않고 바로 식립하였다. 교정력은 식립 직후 바로 NiTi coil spring을 연결하여 가하였으며 일부는 교정력을 가하지 않았고 일부는 100 gm정도의 약한 교정력을 일부는 200 gm정도의 강한 교정력을 가하였다. 실험동물은 3주 혹은 5주에 희생하였으며 72개의 비탈회 표본을 만들어 전반적인 조직학적 관찰과 조직 계측을 시행하였다. 토크 게이지로 최대 식립 토크와 최대 제거 토크를 측정하였다. 모든 microscrew implants는 실험기간 동안 안정되게 유지되었고 최대 제거 토크의 측정에는 self-drilling과 self-tapping microscrew implants 사이에 통계학적으로 유이한 차이가 없었다. 조직 관찰에서 self-tapping microscrew implants에서 골 임프란트 계면에 골결손이 더 많았고 5주에서는 새로이 형성된 미성숙 골이 더 많았다. Self-drilling microscrew implants에서 골표면 혹은 골내막으로의 골 형성이 많이 관찰되었으나 5주에서는 흡수되는 양상을 보였다. 3주에서는 self-drilling microscrew implants가 더 많은 골접촉을 보였으나 5주에서는 두 군사이에 차이가 관찰되지 않았다. 이 결과는 두 방법이 모두 microscrew implant의 식립에 사용될 수 있음을 시사하나 self-tapping microscrew implants의 경우 초기에는 약한 힘을 가하는 것이 좋을 것으로 생각된다.