• 제목/요약/키워드: Pilot drill

검색결과 17건 처리시간 0.025초

터널확공시 이방향 병용천공 발파공법의 개발 (Development of New Drill and Blast Method with Two Different Drilling Directions for Pilot Tunnel Enlargement)

  • 배규진;문홍득
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.199-208
    • /
    • 1994
  • This paper presents an evaluation of new drill and blast method with two different drilling directions for pilot tunnel enlargement using numerical experiment and field test. To evaluate the effieiency of new tunnel enlargement method, field tests were performed and compared with conventional drill and blast method. Also, three dimensional transient dynamic analysis was made to investigate the effect of the ground vibration when blasting was performed at same position using the equivalent single hole charge.

  • PDF

드릴가공에서 강재의 피삭성에 관한 연구 (A Study On the Machinability of Steels by Drilling)

  • 김남훈
    • 한국생산제조학회지
    • /
    • 제5권4호
    • /
    • pp.98-107
    • /
    • 1996
  • In order to predict analytically torque, thrust force, tool life and chip formation in drilling, cutting models for chisel edge with various tool-chip contact length were developed in this type. Also, the experimental tests are run with various pilot holes. The following conclusions were obtained from the analysis. \circled1 It's also found experimentally that thrust force(Fz) decreases as pilot hole diameter increases. \circled2 Surface roughness for material(G) is larger that for material(J). The difference over two materials in roughness value about 0.5$mu extrm{m}$. \circled3 Flank wear of the drill in cutting material of G less than any other kinds of materials(F, G, H, I, J). \circled4 In drilling a deep hole on a workpiece over SM45C either twist drill. The chip was conical helix type at the fist suspensely change the two segment type and than two a long pitch helix style.

  • PDF

사체의 장골에서 수용부 형성방법에 따른 임플란트 일차 안정성 (PRIMARY STABILITY OF IMPLANTS IN ILIUM OF CADAVER BY THE METHODS OF RECIPIENT SITE PREPARATION)

  • 심정우;조진용;국민석;박홍주;오희균
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권2호
    • /
    • pp.180-186
    • /
    • 2008
  • Purpose: This study was performed to evaluate the effect of the implant recipient site preparation methods on primary stability of implants with the instruments of $Osstell^{TM}$ and $Periotest^{(R)}$ in the iliac bone of cadaver. Methods and materials: The 8 iliac bones in 4 cadavers and implants treated with resorbable blasting media (RBM) were used. $Periotest^{(R)}$ (Simens AG, Germany) and $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used to measure primary stability of implants. Implants were inserted into the iliac crest of the cadaver. In control group, the recipient site was prepared according to the manufacturer's recommendation: 1.8 mm guide drill, 2.0 mm initial drill, 2.7 mm pilot drill, 2.7 mm twist drill, 3.0 mm twist drill, 3.3 mm pilot drill, 3.3 mm twist drill, and 3.3 mm countersink drill as well as tapping drill were used in order. In the group 1, implant recipient sites were prepared by sequentially drilling from 1.8 mm guide drill to 3.0 mm twist drill and then inserted implants without countersinking and tapping. In the group 2, implant recipient sites were prepared to 3.0 mm twist drill and countersink drill and then inserted implants without tapping. In the group 3, the sites were prepared to 3.0 mm twist drill and countersink drill as well as tapping drill. In the group 4, the sites were prepared to 3.3 mm twist drill. In the group 5, the sites were prepared to 3.3 mm twist drill and countersink drill. A total of 60 implants were placed (n=10). The stability was measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally and buccolingually. To compare the mean stability of each group statistically, One-way ANOVA was used and correlation of instrument were analyzed using SPSS 12.0. The results obtained were as follows; 1. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ buccolingually showed the highest, and there are significant difference statistically between control group and experimental group 1,2,4 in each instruments respectively (p<0.05). 2. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally showed the highest. There are significant difference statistically between control group and all experimental groups in $Osstell^{TM}$, and between control group and experimental group 1,2,3,4 (p<0.05). 3. There are high correlation between the measurements of $Osstell^{TM}$ and $Periotest^{(R)}$ (p<0.05). Conclusion: These results indicate that the primary stability of implant can be obtained by the recipient sites preparation with smaller diameter drill than that of implant or minimal drilling.

인홀 시험을 이용한 터널 막장의 암반강성 측정에 대한 적용성 연구 (A Pilot Study of Stiffness Mesurements for Tunnel-Face Materials Using In-hole Seismic Method)

  • 목영진;김영수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.445-456
    • /
    • 2005
  • The research concentrates on improving the in-hole seismic probe, which has been developed in past five years, to be used in stiffness measurements of tunnel-face materials. The probe was down-sized to be fit in 45-mm diameter holes(or BX) drilled by a jumbo-drill, which is used to drill holes to install explosives for tunneling. Also trigger system was improved by using a down-speeding motor for operating convenience and air packing system was replaced with a set of plate-springs to eliminate supply of compressed air. These modifications are to adjust the probe for the unfavourable environment inside of tunnels and to test without any further drilling cost. The probe and testing procedure were successfully adopted with horizontal holes drilled by a jumbo-drill at a tunnel-face to evaluate the stiffness of rock mass. The measured shear wave velocities can be used to estimate deformation properties of rock mass for tunnel analyses.

  • PDF

고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구 (Effects of drilling process in stability of micro-implants used for the orthodontic anchorage)

  • 장영일;김종완
    • 대한치과교정학회지
    • /
    • 제32권2호통권91호
    • /
    • pp.107-115
    • /
    • 2002
  • 본 연구는 교정적 고정원을 얻기 위하여 micro-implant(Osas$^{(R)}$, Epoch medical)를 drill method와 drill-free method로 매식시, 조기 교정력에 대한 각각의 경우 micro-implant의 역학적 안정성 및 조직학적 생체 적합도의 차이를 알아보고자 시행하였다. 두 마리의 실험견(beagle dog)을 대상으로 상, 하악 협측과 구개부위에 좌우측을 구분하여 drill method 군과drill-free method 군으로 나누어 매식하였다. 매식 한 재료는 직경 1.6 mm의 micro-implant를 사용하였으며, drill method 군 16개, drill-free method 군 16개, 총32개의 micro-implant를 식립하였다. 교정력은 매식 후 1주 뒤에 Ni-Ti coil spring(Ni-Ti springs-extension$^{(R)}$, Ormco)으로 200 gm - 300 gm의 힘을 적용하였다. 동요도 검사는 희생 전에 Periotest$^{(R)}$(Siemens)로 측정하였다. 매식 12주 후에 관류고정 하였으며 시편은 레진 포매하여 Exakt system$^{(R)}$(Exakt)을 이용하여 비탈회 표본을 제작하였다. 표본은 H-E 염색한 뒤, 광학 현미경 상에서 검경하여 조직학적 소견을 분석하였고 조직계측학적 측정은 골접촉률과 골밀도로 분석하였다. 위와 같은 실험을 통하여 매식한 micro-implant의 탈락률과 동요도, 골접촉률 및 골밀도로 drill method 군과 drill-free method 군의 역학적 안정성 및 조직학적 생체 적합도를 비교, 분석한 결과 다음과 같은 결론을 얻었다. 1. micro-implant와 골의 계면은 기계적 접촉 뿐만 아니라 골유착도 있었다. 2. micro-implant의 탈락은 drill method 군이 더 높았다. 3. 동요도는 drill method 군이 전반적으로 더 컸다. 4. micro-implant와 골접촉 정도는 전반적으로 drill-free method 군에서 양호했다. 5. micro-implant 나사산 사이 내에 존재하는 골밀도는 전반적으로 drill-free method 군에서 더 높았다. 결론적으로, micro-implant는 매식시 drill-free method가 drill method보다 탈락률과 동요도 및 골접촉률과, 골밀도에서 더 우수한 결과를 보여 drilling 과정이 안정성과 골조직 치유 및 골유착에 영향을 미친다고 판단된다.

임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구 (A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION)

  • 김평일;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

인홀 시험을 이용한 터널 막장의 암반강성 측정에 대한 적용성 연구 (A Pilot Study of Stiffness Mesurements for Tunnel-Face Materials Using In-hole Seismic Method)

  • 목영진;김영수
    • 한국지반공학회논문집
    • /
    • 제21권5호
    • /
    • pp.133-142
    • /
    • 2005
  • 본 연구는 지난 5년간 개발해온 인홀 발진자를 터널 막장의 강성도 계측에 사용가능하도록 개선하는데 주력하였다. 프로브는 터널의 폭파를 위해 점보드릴로써 천공된 직경 45m의 홀에 맞추기 위하여 소형화되었다. 또한 트리거 시스템은 감속모터를 사용함으로서 편리하게 되었고, 에어 팩킹 시스템은 압축공기 없이 사용하기위한 플레이트 스프링으로 교체하였다. 이러한 개선은 프로브를 터널내부의 환경에 적합하게 만들고 추가되는 비용 없이 실험하기 위함이다. 프로브와 테스트 과정은 암반의 강성을 측정하기 위해 터널의 막장의 수평 홀에 성공적으로 적용되었다. 측정된 전단파 속도는 터널 해석을 위한 암반의 변형 특성을 측정하는 것에 사용될 수 있다.

인조골에서 식립 방법이 교정용 미니 임플란트의 기계적 안정성에 미치는 영향에 대한 예비연구 (The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study)

  • 조일식;추혜란;김성균;신윤섭;김덕수;김성훈;정규림;존황
    • 대한치과교정학회지
    • /
    • 제41권5호
    • /
    • pp.354-360
    • /
    • 2011
  • Objective: To investigate the effects of different pilot-drilling methods on the biomechanical stability of self-tapping mini-implant systems at the time of placement in and removal from artificial bone blocks. Methods: Two types of artificial bone blocks (2-mm and 4-mm, 102-pounds per cubic foot [102-PCF] polyurethane foam layered over 100-mm, 40-PCF polyurethane foam) were custom-fabricated. Eight mini-implants were placed using the conventional motor-driven pilot-drilling method and another 8 mini-implants were placed using a novel manual pilot-drilling method (using a manual drill) within each of the 2-mm and 4-mm layered blocks. The maximum torque values at insertion and removal of the mini-implants were measured, and the total energy was calculated. The data were statistically analyzed using linear regression analysis. Results: The maximum insertion torque was similar regardless of block thickness or pilot-drilling method. Regardless of the pilot-drilling method, the maximum removal torque for the 4-mm block was statistically higher than that for the 2-mm block. For a given block, the total energy at both insertion and removal of the mini-implant for the manual pilot-drilling method were statistically higher than those for the motor-driven pilot-drilling method. Further, the total energies at removal for the 2-mm block was higher than that for the 4-mm block, but the energies at insertion were not influenced by the type of bone blocks. Conclusions: During the insertion and removal of mini-implants in artificial bone blocks, the effect of the manual pilot-drilling method on energy usage was similar to that of the conventional, motor-driven pilot-drilling method.

파이롯트 터널을 이용한 이방향 천공 발파공법의 진동 저감효과 (Decreasing Effects of Vibration by Drill and VBast Method with Bi-directions using TBM Pilot Tunnels)

  • 이찬우;유진오;이경원;배규진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 춘계학술대회논문집; 전남대학교, 19 May 1995
    • /
    • pp.22-27
    • /
    • 1995
  • 본 연구로부터 얻어진 결론은 다음과 같다. 1. 본 연구에서는 TBM에 의한 파이롯트 터널의 효율성을 극대화한 이방향 천공 발파공법을 개발, 현장실험을 통하여 그 효용성을 입증하였다. 2. NATM 공법에 의한 발파보다 TBM을 이용하여 파이롯트 터널을 굴착하여 확대발파할 경우 상당한 지반진동 경감효과를 얻을 수 있을 것으로 판단된다. 3. 이방향 천공 발파공법의 현장시험 결과, 측정된 지반 진동치는 20% 이상의 진동 경감효과가 있는 것으로 분석되었다. 4. 기존공법과 신공법의 상대비교를 위한 수치해석 결과, 신공법의 방사상 방향 발파는 기존공법의 종방향 발파에 비하여 관심의 대상이 되는 발파공 직상부에서 진동치가 크게 경감되었다.

  • PDF

죽령터널에서의 TBM 굴착속도 및 커터수명 평가연구 (Evaluation of Penetration Rate and Cutter Life of TBM in Jook-Ryung Tunnel)

  • 박철환;신중호;박연준;전석원;안형준
    • 터널과지하공간
    • /
    • 제15권5호
    • /
    • pp.378-386
    • /
    • 2005
  • 중앙고속도로의 죽령터널에서 상하행선 두개의 터널은 발파에 의한 굴착에 앞서 전단면터널 굴착장비로 선행 굴착되었다. 두 대의 TBM시공은 약 1년간 수행되었으며 총 연장은 7.3 km이다. 상하행선에서 순굴착속도는 각각 2.3 m/h 및 2.0 m/h 으로 분석되었으며, 가동률은 각각 $31.4\%$$33.3\%$로 분석되었다. 하행선에서 커터의 부피수명은 $200\~280\;m^3/c$이고, 길이수명은 약 400 m/set로 평가되었는데 이는 노르웨이의 메로케르 수로터널현장에서 얻어진 크기와 유사하다. 지보설계 및 TSP 측정을 통하여 얻어진 현지 암반특성에서 경암일수록 순굴착속도가 작아지는데 이는 과거의 여러 연구에서 분석된 경향과 같다. 이러한 평가연구는 TBM 굴착의 계획과 시공단계에서 원활한 굴착작업을 수행하는데 활용될 수 있을 것으로 판단된다.