• Title/Summary/Keyword: Pilot drill

Search Result 17, Processing Time 0.028 seconds

Development of New Drill and Blast Method with Two Different Drilling Directions for Pilot Tunnel Enlargement (터널확공시 이방향 병용천공 발파공법의 개발)

  • 배규진;문홍득
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.199-208
    • /
    • 1994
  • This paper presents an evaluation of new drill and blast method with two different drilling directions for pilot tunnel enlargement using numerical experiment and field test. To evaluate the effieiency of new tunnel enlargement method, field tests were performed and compared with conventional drill and blast method. Also, three dimensional transient dynamic analysis was made to investigate the effect of the ground vibration when blasting was performed at same position using the equivalent single hole charge.

  • PDF

A Study On the Machinability of Steels by Drilling (드릴가공에서 강재의 피삭성에 관한 연구)

  • 김남훈
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.4
    • /
    • pp.98-107
    • /
    • 1996
  • In order to predict analytically torque, thrust force, tool life and chip formation in drilling, cutting models for chisel edge with various tool-chip contact length were developed in this type. Also, the experimental tests are run with various pilot holes. The following conclusions were obtained from the analysis. \circled1 It's also found experimentally that thrust force(Fz) decreases as pilot hole diameter increases. \circled2 Surface roughness for material(G) is larger that for material(J). The difference over two materials in roughness value about 0.5$mu extrm{m}$. \circled3 Flank wear of the drill in cutting material of G less than any other kinds of materials(F, G, H, I, J). \circled4 In drilling a deep hole on a workpiece over SM45C either twist drill. The chip was conical helix type at the fist suspensely change the two segment type and than two a long pitch helix style.

  • PDF

PRIMARY STABILITY OF IMPLANTS IN ILIUM OF CADAVER BY THE METHODS OF RECIPIENT SITE PREPARATION (사체의 장골에서 수용부 형성방법에 따른 임플란트 일차 안정성)

  • Sim, Jung-Woo;Cho, Jin-Yong;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.180-186
    • /
    • 2008
  • Purpose: This study was performed to evaluate the effect of the implant recipient site preparation methods on primary stability of implants with the instruments of $Osstell^{TM}$ and $Periotest^{(R)}$ in the iliac bone of cadaver. Methods and materials: The 8 iliac bones in 4 cadavers and implants treated with resorbable blasting media (RBM) were used. $Periotest^{(R)}$ (Simens AG, Germany) and $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used to measure primary stability of implants. Implants were inserted into the iliac crest of the cadaver. In control group, the recipient site was prepared according to the manufacturer's recommendation: 1.8 mm guide drill, 2.0 mm initial drill, 2.7 mm pilot drill, 2.7 mm twist drill, 3.0 mm twist drill, 3.3 mm pilot drill, 3.3 mm twist drill, and 3.3 mm countersink drill as well as tapping drill were used in order. In the group 1, implant recipient sites were prepared by sequentially drilling from 1.8 mm guide drill to 3.0 mm twist drill and then inserted implants without countersinking and tapping. In the group 2, implant recipient sites were prepared to 3.0 mm twist drill and countersink drill and then inserted implants without tapping. In the group 3, the sites were prepared to 3.0 mm twist drill and countersink drill as well as tapping drill. In the group 4, the sites were prepared to 3.3 mm twist drill. In the group 5, the sites were prepared to 3.3 mm twist drill and countersink drill. A total of 60 implants were placed (n=10). The stability was measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally and buccolingually. To compare the mean stability of each group statistically, One-way ANOVA was used and correlation of instrument were analyzed using SPSS 12.0. The results obtained were as follows; 1. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ buccolingually showed the highest, and there are significant difference statistically between control group and experimental group 1,2,4 in each instruments respectively (p<0.05). 2. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally showed the highest. There are significant difference statistically between control group and all experimental groups in $Osstell^{TM}$, and between control group and experimental group 1,2,3,4 (p<0.05). 3. There are high correlation between the measurements of $Osstell^{TM}$ and $Periotest^{(R)}$ (p<0.05). Conclusion: These results indicate that the primary stability of implant can be obtained by the recipient sites preparation with smaller diameter drill than that of implant or minimal drilling.

A Pilot Study of Stiffness Mesurements for Tunnel-Face Materials Using In-hole Seismic Method (인홀 시험을 이용한 터널 막장의 암반강성 측정에 대한 적용성 연구)

  • Mok, Young-Jin;Kim, Young-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.445-456
    • /
    • 2005
  • The research concentrates on improving the in-hole seismic probe, which has been developed in past five years, to be used in stiffness measurements of tunnel-face materials. The probe was down-sized to be fit in 45-mm diameter holes(or BX) drilled by a jumbo-drill, which is used to drill holes to install explosives for tunneling. Also trigger system was improved by using a down-speeding motor for operating convenience and air packing system was replaced with a set of plate-springs to eliminate supply of compressed air. These modifications are to adjust the probe for the unfavourable environment inside of tunnels and to test without any further drilling cost. The probe and testing procedure were successfully adopted with horizontal holes drilled by a jumbo-drill at a tunnel-face to evaluate the stiffness of rock mass. The measured shear wave velocities can be used to estimate deformation properties of rock mass for tunnel analyses.

  • PDF

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

A Pilot Study of Stiffness Mesurements for Tunnel-Face Materials Using In-hole Seismic Method (인홀 시험을 이용한 터널 막장의 암반강성 측정에 대한 적용성 연구)

  • Mok Young-Jin;Kim Young-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.133-142
    • /
    • 2005
  • The research concentrates on improving the in-hole seismic probe, which has been developed in past five years, to be used in stiffness measurements of tunnel-face materials. The size of probe was reduced to be fit in 45-mm diameter holes (or BX) drilled by a jumbo-drill, which is used to drill holes to install explosives for tunneling. Also trigger system was improved by using a down-speeding motor for operating convenience and air packing system was replaced with a set of plate-springs to eliminate supply of compressed air. These modifications are to adjust the probe for the unfavourable environment inside of tunnels and to test without any further drilling cost. The probe and testing procedure were successfully adopted with horizontal holes drilled by a jumbo-drill at a tunnel-face to evaluate the stiffness of rock mass. The measured shear wave velocities can be used to estimate deformation properties of rock mass for tunnel analyses.

The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study (인조골에서 식립 방법이 교정용 미니 임플란트의 기계적 안정성에 미치는 영향에 대한 예비연구)

  • Cho, Il-Sik;Choo, Hye-Ran;Kim, Seong-Kyun;Shin, Yun-Seob;Kim, Duck-Su;Kim, Seong-Hun;Chung, Kyu-Rhim;Huang, John C.
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.354-360
    • /
    • 2011
  • Objective: To investigate the effects of different pilot-drilling methods on the biomechanical stability of self-tapping mini-implant systems at the time of placement in and removal from artificial bone blocks. Methods: Two types of artificial bone blocks (2-mm and 4-mm, 102-pounds per cubic foot [102-PCF] polyurethane foam layered over 100-mm, 40-PCF polyurethane foam) were custom-fabricated. Eight mini-implants were placed using the conventional motor-driven pilot-drilling method and another 8 mini-implants were placed using a novel manual pilot-drilling method (using a manual drill) within each of the 2-mm and 4-mm layered blocks. The maximum torque values at insertion and removal of the mini-implants were measured, and the total energy was calculated. The data were statistically analyzed using linear regression analysis. Results: The maximum insertion torque was similar regardless of block thickness or pilot-drilling method. Regardless of the pilot-drilling method, the maximum removal torque for the 4-mm block was statistically higher than that for the 2-mm block. For a given block, the total energy at both insertion and removal of the mini-implant for the manual pilot-drilling method were statistically higher than those for the motor-driven pilot-drilling method. Further, the total energies at removal for the 2-mm block was higher than that for the 4-mm block, but the energies at insertion were not influenced by the type of bone blocks. Conclusions: During the insertion and removal of mini-implants in artificial bone blocks, the effect of the manual pilot-drilling method on energy usage was similar to that of the conventional, motor-driven pilot-drilling method.

Decreasing Effects of Vibration by Drill and VBast Method with Bi-directions using TBM Pilot Tunnels (파이롯트 터널을 이용한 이방향 천공 발파공법의 진동 저감효과)

  • 이찬우;유진오;이경원;배규진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.22-27
    • /
    • 1995
  • 본 연구로부터 얻어진 결론은 다음과 같다. 1. 본 연구에서는 TBM에 의한 파이롯트 터널의 효율성을 극대화한 이방향 천공 발파공법을 개발, 현장실험을 통하여 그 효용성을 입증하였다. 2. NATM 공법에 의한 발파보다 TBM을 이용하여 파이롯트 터널을 굴착하여 확대발파할 경우 상당한 지반진동 경감효과를 얻을 수 있을 것으로 판단된다. 3. 이방향 천공 발파공법의 현장시험 결과, 측정된 지반 진동치는 20% 이상의 진동 경감효과가 있는 것으로 분석되었다. 4. 기존공법과 신공법의 상대비교를 위한 수치해석 결과, 신공법의 방사상 방향 발파는 기존공법의 종방향 발파에 비하여 관심의 대상이 되는 발파공 직상부에서 진동치가 크게 경감되었다.

  • PDF

Evaluation of Penetration Rate and Cutter Life of TBM in Jook-Ryung Tunnel (죽령터널에서의 TBM 굴착속도 및 커터수명 평가연구)

  • Park Chul-Whan;Synn Joong-Ho;Park Yeon-Jun;Jeon Seok-Won;An Hyung-Jun
    • Tunnel and Underground Space
    • /
    • v.15 no.5 s.58
    • /
    • pp.378-386
    • /
    • 2005
  • Jook-Ryung roadway tunnel was constructed by drill-blast after pilot tunnelling by 2 TBMS. nis report analyzes the data for TBM performance in the total length of 7.3 km for the two pilot tunnels. Net penetration rates were recorded as high as 2.3 m/h and 2.0 m/h for the two different directions while degrees of operation were $31.4\%$ and $33.3\%$, respectively. The cutter lives for No.2 tunnel were evaluated $200\~280\;m^3/c$ and around 400 m/set as high as for Meraker 10 km tunnel in Norway. The relationship between net penetration rate and characteristics of rock mass which were obtained by RMR and TSP measurement, coincides with the prior studies. This kind of evaluation is expected to be used to design TBM tunnelling and to help to perform the TBM operation effectively