• Title/Summary/Keyword: Pilot Reactor

Search Result 212, Processing Time 0.022 seconds

Measurement of Biological Activity in Pilot Scale Dyeing Wastewater Process by Using Respirometer (호흡률 측정기를 이용한 파일럿 스케일 염색폐수처리 장치에서의 생물학적 활성 측정)

  • Jeon Hyun Hee;Choi Kwang Keun;Yoon In Jun;Lee Jin Won
    • KSBB Journal
    • /
    • v.19 no.5
    • /
    • pp.390-393
    • /
    • 2004
  • Oxygen uptake rate (OUR) was used as an indicator of microbial activity. In this study OUR at dyeing wastewater in the pilot plant was monitored to examine biological activity. Correlation between inlet COD concentration and maximum OUR showed that maximum OUR was proportional to inlet COD concentration. Changes in the OUR values reflected the changing waste load in the reactor. Consequently, OUR can be used to estimate biological activity of inlet COD concentration. This study showed that biodegradable COD at dyeing wastewater could be calculated from OUR and yield coefficient. Non-biodegradable COD was able to be calculated from a difference between initial COD concentration and biodegradable COD.

Operational Characteristics of Pilot Scale Plasma DeSOx-DeNOx System for Treatment of Coal-Fired Flue Gas (석탄연소 배가스 처리용 플라즈마 탈황탈질 시스템의 운전 특성)

  • Jang, Gil-Hong;Paek, Min-Su;Kim, Tae-Hee;Jeong, Jong-Han
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1806-1808
    • /
    • 1998
  • Tests of pilot-scale plasma DeSOx-DeNOx system using pulsed streamer corona were carried out. The system consists of the reactor with wire-plate electrodes the $30kW_{max}$. MPC type pulse generator, and $1MW_{th}$ pulverized coal combustor as a flue gas source. $NH_3$ and $C_2H_4$ were used to enhance the removal rate. The experimental result on the removal efficiency of SOx/NOx and on the effect of the additives was presented in this paper.

  • PDF

Study for improvement of zero-cross detector of control element drive mechanism control system in PWR (경수로 제어봉구동장치제어계통의 영점위상탐지기 성능개선에 관한 연구)

  • 김병문;이병주;한상준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.609-611
    • /
    • 1996
  • Zero-Cross Detector makes pilot signal to control the power to CEDM(Control Element Drive Mechanism). Existing Zero-Cross Detectors has had a problem which can cause unexpected reactor trip resulted from fluctuating frequency of input signal coming from M/G Set. The existing Zero-Cross Detector can't work properly when power frequency is varying because it was designed to work under stable M/G Set operation, and produces wrong pilot signal and output voltage. In this report the Zero-Cross Detector is improved to resolve voltage fluctuating problem by using new devices such as digital noise filtering circuit, variable cycle compensator and alarm circuit. And through the performance verification it shows that new circuit is better than old one. If suggested detector is applied to plant, it is possible to use it under House Load Operation because stable voltage can be generated by new Zero-Cross Detector.

  • PDF

Evaluation of Continuously and Intermittently Aerated Hog Manure Compost Stability in a Pilot-scale Bin Composting System (파일럿 규모 빈 퇴비화 시스템에서 연속 및 간헐 통기 돈분 퇴비의 안정도 평가)

  • Hong, Ji-Hyung
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 1998
  • Compost stability represents the state of microbiological activity and measurements of respiration either through $CO_2$ evolution or $O_2$ uptake should provide the best indication of this state. Hog manure amended with sawdust was composted in a pilot-scale reactor vessels using continuous and intermittent aeration for 3 weeks. In this study we evaluated the $CO_2$ respiration rate effect of aeration method on the reduction of $CO_2$ evolution, and investigated the stability of fresh and finished compost for plant growth. The intermittently aerated composting is a practical proposition for a very stable compost making. The $CO_2$ respiration rate in the fresh and finished compost during intermittently aerated composting was maintained from 0.3 to 1.4 and was good for use in horticulture, while the continuously aerated composting was 7 to 23 and needed more time for compost curing.

  • PDF

Pilot Scale Experiments on the Oxidation of $TiCl_4$ ($TiCl_4$의 산화반응에 대한 파이롯트 규모 실험)

  • 박균영;이익형;양현수
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.6
    • /
    • pp.817-823
    • /
    • 1990
  • Pilot-scale experiments on the oxidation of TiCl4 to produce TiO2 were carried out in a verical reactor of 20cm in inside diameter and 140cm in length ; LPG burning was used as a heating means to maintain the reaciton temperature. The effects of reaction temperature and excess oxygen content on the conversion of TiCl4 and on the particle size of produced TiO2 were investigated. The ranges of operating conditions varied were 900 to TiO2 was 0.45-0.57${\mu}{\textrm}{m}$, TiCl4 conversion was 82-96%, the rutile content was 33-57% and the contents of impurities were 0.03% of Fe, 0.03% of SiO2 and 62ppm of Cl. These experimental results were compared with those of other investigators.

  • PDF

The study for Biological nutrient removal of High-strength nitrogen loading rate using B3 pilot plant (B3 Pliot plant를 이용한 고농도 질소부하에서의 고도처리에 관한 연구)

  • Eorn Tae-Kyu;Han Dong-Yueb;Kim Boo-Gil
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.771-775
    • /
    • 2005
  • The purpose of this research was to investigate applicative possibility of field. Pilot-scale experiments were conducted, at outdoor temperature, HRT l0hour, IR(Internal Recycle) $150\%$ and used $2.8m^3$ Reactor. External carbon source was varied 80 to 120 mg/L. When External carbon source and Alkalinity were injected to the B3 pilot plant, the removal efficiencies of COD and BOD were not decreased. Nitrification rate were 5.95, 5.40, 4.08 $mgNH_4^+-N/gSS/d$ during operation periods and denitrification rate was $3.l2mgNO_3^--N/gSS/d.$ When we surveyed the relationship between loading rate of nitrogen and nitrogen removal quantity, this data was 0.949, B3 process will be possible application process of field.

Highly Pure Culture of Photosynthetic Bacteria for Pilot-scale Production (광합성세균의 파이롯트 단위 생산을 위한 고순도 배양)

  • Cho, Kyoung Sook;Yim, Tae Bin;Jeong, Hae Yoon;Cho, Jeong Sub;Kim, Joong Kyun
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.1 no.4
    • /
    • pp.292-297
    • /
    • 2006
  • Lab-scale and pilot-scale productions of photosynthetic bacteria, that were able to efficiently treat wastewater from aquacultural farm, were experimented for their highly-pure culture. The results of experiments in a gas pack reactor, an anaerobic flask and a flask using $N_2$ gas as N-source showed that only photosynthetic bacteria formed red colonies on agar plate and their purity was over 90% in a colony, observed under a microscope. It was found that the basal medium could most promote the growth of photosynthetic bacteria, confirmed by experiments of serial cultures on various media. Under the culture conditions, the specific growth rate was found to be $0.18h^{-1}$ from the culture in 5L bioreactor and the same value could be obtained in pilot-scale production.

  • PDF

Evaluation of the Nutrient Removal Performance of the Pilot-scale KNR (Kwon's Nutrient Removal) System with Dual Sludge for Small Sewage Treatment (소규모 하수처리를 위한 파일럿 규모 이중슬러지 KNR® (Kwon's nutrient removal) 시스템의 영얌염류 제거성능 평가)

  • An, Jin-Young;Kwon, Joong-Chun;Kim, Yun-Hak;Jeng, Yoo-Hoon;Kim, Doo-Eon;Ryu, Sun-Ho;Kim, Byung-Woo
    • Clean Technology
    • /
    • v.12 no.2
    • /
    • pp.67-77
    • /
    • 2006
  • A simple dual sludge process, called as $KNR^{(R)}$ (Kwon's Nutrient Removal) system, was developed for small sewage treatment. It is a hybrid system that consists of an UMBR (Upflow multi-layer bioreactor) as anaerobic and anoxic reactor with suspended denitrifier and a post aerobic biofilm reactor, filled with pellet-like media, with attached nitrifier. To evaluate the stability and performance of this system for small sewage treatment, the pilot-scale $KNR^{(R)}$ plant with a treatment capacity of $50m^3/d$ was practically applied to the actual sewage treatment plant, which was under retrofit construction during pilot plant operation, with a capacity of $50m^3/d$ in a small rural community. The HRTs of a UMBR and a post aerobic biofilm reactor were about 4.7 h and 7.2 h, respectively. The temperature in the reactor varied from $18.1^{\circ}C$ to $28.1^{\circ}C$. The pilot plant showed stable performance even though the pilot plant had been the severe fluctuation of influent flow rate and BOD/N ratio. During a whole period of this study, average concentrations of $COD_{cr}$, $COD_{Mn}$, $BOD_5$, TN, and TP in the final effluent obtained from this system were 11.0 mg/L, 8.8 mg/L, 4.2 mg/L, 3.5 mg/L, 9.8 mg/L, and 0.87/0.17 mg/L (with/without poly aluminium chloride(PAC)), which corresponded to a removal efficiency of 95.3%, 87.6%, 96.3%, 96.5%, 68.2%, and 55.4/90.3%, respectively. Excess sludge production rates were $0.026kg-DS/m^3$-sewage and 0.220 kg-DS/kg-BOD lower 1.9 to 3.8 times than those in activated sludge based system such as $A_2O$ and Bardenpho.

  • PDF

Combustion Characteristics of Imported Bituminous & Subbituminous Coal in a Pilot Scale Test Facility (발전용 역청탄 및 아역청탄의 파일롯 연소특성 평가)

  • Kim, Hyunhee;Park, Hoyoung;Lim, Hyunsoo;Baek, Sehyun;Kim, Taehyung;Kim, Youngju;Gong, Jiseon;Lee, Jeongeun
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.207-214
    • /
    • 2014
  • With the depletion of high grade coal, it is indispensable to be used co-combustion of low rank coal with bituminous coal in pulverized coal-fired power plants. This study describes the detailed measurements of combustion characteristics of bituminous and subbituminous coal in a 0.7MWth pilot-scale test facility. This experimental works include the measurement of gas temperature, gas concentrations along with the reactor axial and radial distance at the condition of excess air ratio of 1.2. The solid sampling was carried out and analyzed with the combustion of bituminous coal. The main reaction zone of coal flame in a reactor was formed about 1 m from the swirl burner, and at downstream, the fully developed temperature and species distribution was observed. The sampled particles of bituminous coal in a reactor revealed the complete carbon burn-out was achieved just after an main combustion zone.

A Study on the NOx Removal Rate by Arrangement of Discharge Electrode in Pulsed Corona Discharge Reactor (펄스 코로나 반응기에서 방전극의 배열에 따른 탈질율 연구)

  • Choi, Min;Park, So-Jin;Wi, Young-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.3
    • /
    • pp.315-323
    • /
    • 2003
  • The goal of this study if the optimization of discharge electrode for pulsed corona discharge reactor located in thermal power plant. For this purpose, we have performed experiments of NO$_{x}$ removal rate by exchange of discharge electrode diameter and arrangement of discharge electrode in the non -thermal plasma reaction facility using a ethylene as additive. If the diameter and numbers of discharge electrode were larger, the NO$_{x}$ removal rate was higher. From these results, if we optimized the shape and installed numbers of discharge electrode at the pilot plant, we could increase the NO$_{x}$ removal rate with less amount of additive than current amount.mount.