  • Pile driving formula, wave equation analysis of pile driving(WEAP) and dynamic pile loading test have been known to useful tools to appraise the behaviour of pile driving. This paper reviews basic theories of three methods and gives some suggestions to apply them to practice. And also some cases on application of the methods to the sites are discussed in this paper. It appears that it is inevitable for engineers to be experienced well so that the methods can be regarded as useful tools.

  • PDF

파동방정식 및 잔류응력에 의한 항타지대력 추정 (Prediction of Pile-Driving Resistance by the Wave Equation and Residual Stress)

  • 황정규
    • 한국지반공학회지:지반
    • /
    • 제2권3호
    • /
    • pp.15-26
    • /
    • 1986
  • 말뚝박기에서 항타지지력을 추정하기 위하여 수많은 항타공식이 널리 사용되고 있으나 말뚝의 지지력은 해머-말뚝-지반토의 복잡한 상호작용에 의하여 변화하기 때문에 어느 공식이 현장조건에 가장 적합한 공식이라 판단하기는 매우 어렵다. 본 연구에서는 파동이론과 말뚝의 잔류응력에 의하여 항타지지력을 해석하므로서 현장에서 간편하게 추정할 수 있는 신뢰도가 높은 산출식을 유도하여 이를 고찰하였다.

  • PDF

수중 대구경강관말뚝의 항타관입성 모니터링을 위한 PDA 적용 사례 (Drivability Monitoring of Large Diameter Underwater Steel Pipe Pile Using Pile Driving Analyzer.)

  • 김대학;박민철;강형선;이원제
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.11-19
    • /
    • 2004
  • When pile foundation constructed by driving method, it is desirable to perform monitoring and estimation of pile drivability and bearing capacity using some suitable tools. Dynamic Pile Monitoring yields information regarding the hammer, driving system, and pile and soil behaviour that can be used to confirm the assumptions of wave equation analysis. Dynamic Pile Monitoring is performed with the Pile Driving Analyser. The Pile Driving Analyser (PDA) uses wave propagation theory to compute numerous variables that fully describe the condition of the hammer-pile-soil system in real time, following each hammer impact. This approach allows immediate field verification of hammer performance, driving efficiency, and an estimate of pile capacity. The PDA has been used widely as a most effective control method of pile installations. A set of PDA test was performed at the site of Donghea-1 Gas Platform Jacket which is located east of Ulsan. The drilling core sediments of location of jacket subsoil are composed of mud and sand, silt. In this case study, the results of PDA test which was applied to measurement and estimation of large diameter open ended steel pipe pile driven by underwater hydraulic hammer, MHU-800S, at the marine sediments were summarized.

  • PDF

항타공식의 신뢰도 (Reliability of Pile Driving Formula)

  • 박영호;김경석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 1999
  • Prefabricated piles used for construction of highway bridges are most of steel pipe piles and few of prestressed concrete piles. Its installation and inspection are less controllable and have much uncertainty due to changes in subsoil and groundwater conditions. However, most of these piles have been controlled using outdated pile driving formula such as Hiley's formula which models just the energy conservation due to its simple applicability in the field. This formula results in overstriking or sometimes understocking due to buckling of pile head. Engineers cannot ensure by the formula whether pile is installed properly. To compensate the drawbacks of excising pile formula, parameters in Hiley's formula and 55 formula are reviewed. Final sets used in pile formula and PDA test results(E.O.I.D) are measured during pile driving along the depth. These measured results along the depth were compared with each other and with N values, so that relations between the each result could be inferred. Also the factor of safety which can be used for pile driving formula are suggested.

  • PDF

An application of wave equation analysis program to pile dynamic formulae

  • Tokhi, H.;Ren, G.;Li, J.
    • Geomechanics and Engineering
    • /
    • 제9권3호
    • /
    • pp.345-360
    • /
    • 2015
  • Wave equation analysis programs (WEAP) such as GRLWEAP and TNOWave were primarily developed for pre-driving analysis. They can also be used for post-driving measurement applications with some refinements. In the case of pre-driving analysis, the programs are used for the purpose of selecting the right equipment for a given ground condition and controlling stresses during pile driving processes. Recently, the program is increasingly used for the post-driving measurement application, where an assessment based on a variety of input parameters such as hammer, driving system and dynamic behaviour of soil is carried out. The process of this type of analysis is quite simple and it is performed by matching accurately known parameters, such as from CAPWAP analysis, to the parameters used in GRLWEAP analysis. The parameters that are refined in the typical analysis are pile stresses, hammer energy, capacity, damping and quakes. Matching of these known quantities by adjusting hammer, cushion and soil parameters in the wave equation program results in blow counts or sets and stresses for other hammer energies and capacities and cushion configuration. The result of this analysis is output on a Bearing Graph that establishes a relationship between ultimate capacity and net set per blow. A further application of this refinement method can be applied to the assessment of dynamic formulae, which are extensively used in pile capacity calculation during pile driving process. In this paper, WEAP analysis is carried out to establish the relationship between the ultimate capacities and sets using the various parameters and using this relationship to recalibrate the dynamic formula. The results of this analysis presented show that some of the shortcoming of the dynamic formula can be overcome and the results can be improved by the introduction of a correction factor.

저진동 파일시공법에 따른 지반진동 응답 예측을 위한 실험적 연구 (Experimental Study for Prediction of Ground Vibration Responses by the Low-Vibration Pile Driving Methods)

  • 강성후;박선준;정석규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.201-207
    • /
    • 2010
  • In this study, the SIP (Soil-cement Injected precast Pile) method among the Low-vibration & Low-noise pile driving methods was decided into study compensation. Ground vibrations by the SIP methods step by step divide and were analyzed. Quantitative response values and ground vibration equations with reliability were presented from findings of this study. Also, vibration responses that are occurred by the SIP method of construction were compared as quantitative with vibration responses by general method of construction that are presented in existent study. Ground vibration values by the SIP method correspond to level of 17 ~ 57% of values that are assumed by the Attewell & Famer's equation, respectively, and these result compares in reliability 50% and separated distance 10 ~ 50 m. Also, those values were analyzed that correspond to level of 14 ~ 96% of ground vibration values by the Prof. Park's equation, respectively. Construction limit extents, separation distances from vibration occurs position, were presented that can satisfy domestic criteria for vibration control for the SIP methods. Those presented in this paper were divided newly according to reliability.

  • PDF

PRD Pile Driving공법의 진동저감 평가를 위한 실험적 연구 (Experimental Study on Vibration Reduction Estimation of PRD Pile Driving Method)

  • 강성후;박선준;정석규
    • 한국소음진동공학회논문집
    • /
    • 제18권7호
    • /
    • pp.775-782
    • /
    • 2008
  • In this study, ground vibrations and aero space noises that is produced by the PRD(percussion rotary drill) were analyzed by work processes. Ground vibration equations were suggested by $2.798(SD)^{-0.793}$, $3.485(SD)^{-0.793}$, $3.705(SD)^{-0.793}$, according to experiment result, and these equations have reliability of 50%, 90%, 95%, respectively. Ground vibration values by the PRD method correspond to level of $5{\sim}34%$ of values that are assumed by the Attewell & Farmer's equation, and these result compares in reliability 50%. Also, those values were analyzed that correspond to level of $12{\sim}26%$ of ground vibration values by the Prof. Park etc.'s equations. But, the aero space noise was evaluated that is assumed by 88.9 dB(A) at separated distance 50m and is not satisfied even 85dB(A) that is the most negative noise value that present in domestic noise standard. The PRD method was analyzed that noise decrease effect exists hardly comparing with general pile driving method of construction. When is based in these results, the PRD method is judged that it is desirable that classify by the Low-vibration method more than the Non-violation noise method.

이어도 해양과학기지 말뚝기초의 항타 관입성 연구 (Drivability of Offshore Pile Foundation at Ieodo Ocean Research Station)

  • 심재설;윤길림;이승준
    • Ocean and Polar Research
    • /
    • 제25권spc3호
    • /
    • pp.373-384
    • /
    • 2003
  • When pile foundation is constructed by dynamic method, it is desirable to perform monitoring of drivability with pile penetration. Dynamic pile monitoring yields information regarding driving hammer, cushion, pile and soil behaviour that can be used to confirm the assumptions of wave equation analysis. In this study, dynamic monitoring of the steel pipe pile was performed with Pile Driving Analyser (PDA). The PDA utilizes the wave propagation theory to compute numerous variables which describe the conditions of the hammer-pile-soil system in real-time and following each hammer impact. This approach allows immediate field verification of hammer performance, driving efficiency, and estimation of pile bearing capacity. A series of PDA test were performed at the Ieodo Ocean Research Station (IORS) located in southeast of Marado, a southernmost small island south of Jeju Island. The drilling core sediments of Ieodo subsoil are composed of mud and sand, showing lamination and wavy or lenticular bedding, which were often bioturbated. This paper summarizes the results of PDA tests which were applied in measurement and estimation of large diameter open ended steel pipe pile driven by steam hammer, Vulcan-560 and MRBS-4600, at the marine sediments.

Set-up 효과를 반영한 타입말뚝의 파동이론해석 (Consideration of Set-up Effect in Wave Equation Analysis of Pile Driving.)

  • 천병식;조천환
    • 한국지반공학회논문집
    • /
    • 제15권2호
    • /
    • pp.95-104
    • /
    • 1999
  • Set-up현상이 나타나는 지반에 항타된 말뚝의 지지력은 시간경과에 따라 지지력이 증가하게 된다. 파동이론해석법(WEAP해석법)은 말뚝의 항타관입성을 평가하는데 매우 유용한 것으로 평가되고 있다. 그러나 기존의 WEAP해석법은 항타후 변화하는 지반의 강도특성을 고려할 수 없다는 측면에서 재항타시의 신뢰도 있는 지지력을 예측하는데 한계가 있다고 평가된다. WEAP에 의한 항타말뚝의 지지력 평가가 신뢰성 있기 위해서는 set-up효과가 반영되어야만 한다. 그러나 아직까지 이를 고려할 수 있는 만족할 만한 방법이 없다. 본 논문에서는 항타시와 재항타시의 동재하시험 결과들을 통계분석하여 WEAP해석시 set-up효과를 반영할 수 있는 방안을 제시하였다. 또한 현장 시험결과와의 비교를 통해서, 제안된 변수(quake, damping)를 적용한 파동이론해석 결과는 기존의 방법보다 신뢰성이 있음을 알 수 있었다.

  • PDF

WEAP 프로그램을 이용한 U형 널말뚝의 항타관입성 해석 (Driveability Analysis of U-type Sheet Pile using WEAP Program)

  • 김병일;김재규;이승현;이종구
    • 한국산학기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.671-678
    • /
    • 2006
  • 진동해머를 이용한 널말뚝 시공은 소음에 민감한 도심지 굴착 공사에 유용하다. 그러나 널말뚝의 진동-항타 시공시 항타관입성에 대한 연구는 거의 수행된 적이 없다. 이 연구에서는 국내에서 많이 사용되고 있는 U형 널말뚝을 진동해머를 이용하여 시공할 때 여러 가지 조건에 따른 항타관입성을 WEAP 프로그램을 이용하여 분석하였다. 해석결과 널말뚝의 관입속도는 N값이 클수록 느려지며, 20m 이내로 시공되는 경우 단면적이 클수록 느려지는 것으로 나타났다.