• Title/Summary/Keyword: Pile bearing capacity

Search Result 535, Processing Time 0.023 seconds

The Characteristics of the Set-up Effect of Driven Piles (타입 말뚝의 지지력 증가효과 특성)

  • 조천환
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.235-246
    • /
    • 2003
  • Since the study of Lee et al.(1994) there have been some case studies on the set-up effect of driven piles in Korea country. However, comprehensive examination on the analyses of the set-up effect with various testing data has not been carried out. In particular, the analysis of the influence of soil type and pile shape on the set-up effect has not been reported. It is necessary to analyse the test results of production piles in order to apply the set-up effect of driven piles for the field engineering. In this study some test piling and analyses were performed to give basic information to the piling design as well as the research on the set-up effect in sandy soils. The analyses on the set-up effect were performed with the monitoring data obtained from the high-strain dynamic loading tests. It was shown that the set-up effect of driven piles was not only affected by soil type but also by soil formation history It turned out that the set-up effect in sandy soils was considerable one that should not be ignored in the field, and that the bearing capacity increase of pile is mainly caused by the increase of shaft resistance. It was shown that the set-up effect of closed pile was larger than that of opened pile in clayey soils, while the set-up effect of opened pile was larger than that of closed pile in sandy soils.

Numerical Study on Lateral Pile Behaviors of Piled Gravity Base Foundations for Offshore Wind Turbine (수치해석을 통한 해상풍력 말뚝지지중력식기초의 수평거동 분석)

  • Seo, Ji-Hoon;Choo, Yun Wook;Goo, Jeong-Min;Kim, Youngho;Park, Jae Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.11
    • /
    • pp.5-19
    • /
    • 2016
  • This paper presents the results from three-dimensional finite element (FE) analysis undertaken to provide insight into the lateral behaviors of piled gravity base foundation (GBF) for offshore wind turbine. The piled GBF was originally developed to support the gravity based foundation in very soft clay soil. A GBF is supported by five piles in a cross arrangement to achieve additional vertical bearing capacity. This study considered four different cases including a) single pile, b) three-by-three group pile (with nine piles), c) cross-arrangement group pile (with five piles), and d) piled GBF. All the cases were installed in homogenous soft clay soil with undrained shear strength of 20 kPa. From the numerical results, p-y curves and thus P-multiplier was back-calculated. For the group pile cases, the group effect decreased with increasing the number of piles. Interestingly, for the piled GBF, the P-multipliers showed a unique trend, compared to the group pile cases. This study concluded that the global lateral behaviour of the piled GBF was influenced strongly by the interaction between GBF and contacted soil surface.

Behaviour Characteristics of Sand Compaction Pile with varying Area Replacement Ratio (모래다집말뚝(SCP)의 치환율 변화에 따른 거동 특성 연구)

  • 박용원;김병일;윤길림;이상익;문대중;권오순
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.117-128
    • /
    • 2000
  • Sand compaction pile(SCP) is one of the ground improvement techniques which is being used for not only accelerating consolidation but also increasing bearing capacity of loose sands or soft clay grounds. In this study, laboratory model test and large-scale direct shear test were performed to investigate the effects of area replacement ratio of composite ground in order to find out the optimum value of area replacement ratio for the ground improvement purpose. Area replacement ratios of 20%, 30%, 40%, 50%, 60% were chosen respectively in the model tests to study the effects of area replacement ratio on variations of stress concentration ratio, settlement and shear strength characteristics of composite ground. In large-scale direct she4ar tests, area replacement ratios of 20%, 30%, 46% were applied to study their effects on shear strength characteristics of composite ground.

  • PDF

A Study on Prediction of Moment Developed in Bottom of Foundations between Pile and Heterogeneous Soils (말뚝기초와 이질지반 경계부 기초저판에서의 발생모멘트 예측에 관한 연구)

  • Lim, Hae-Sik;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.277-285
    • /
    • 2011
  • To reinforce bearing capacity-changed section or different foundation in the same building, empirical or simple tools have been used. To solve this problem, an analytical solution which can evaluate and reinforce the stability of foundation is introduced. To suggest a clue for the problems, current foundation reinforcing method is studied through recent literature studies and the structural analyses of foundation slab are performed on the pile foundation of 49$m^2$, 59$m^2$ and 84$m^2$ I type apartments in 15 story building. The analyses are conducted with SAP 2000, a computer program for ordinary structural analysis. To predict the moments of slab by ground non-uniformity, the structural analysis results for the foundation slab of 3 types 15 story apartment buildings in 49$m^2$, 59$m^2$ and 84$m^2$ I type on non-uniformity ground are shown in the diagrams.

Variation of Stress Concentration Ratio with Area Replacement Ratio for SCP-Reinforced Soils under Quay Wall (치환율에 따른 안벽구조물 하부 SCP 복합지반의 응력분담비)

  • 김윤태
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2004
  • In order to accelerate the rate of consolidation settlement, to reduce settlement, and to increase bearing capacity for soft ground under quay, sand compaction pile method (SCP) has usually been applied. SCP-reinforced ground is composite soil which consists of the sand pile and the surrounding soft soil. One of main important considerations in design and analysis for SCP-reinforced soils is stress concentration ratio according to area replacement ratio. In this paper, the numerical analysis was conducted to investigate characteristics of stress concentration ratio in composite ground. It was found that stress concentration ratio of composite ground is not constant as well as depends on several factors such as area replacement ratio, depth of soft soil, and consolidation process. The values of stress concentration ratio increase during loading stage due to stress transfer of composite soil, and reach up to 2.5∼12 according to area replacement ratio at the end of construction. After the end of consolidation, however, these values are converged to 2.5 to 6.0 irrespective of area replacement ratio due to increase in effective stress of soft soil during consolidation process.

A Study on the Transmission Tower Foundation Design and Construction Method - A Focus of Cylindrical Foundation - (가공 송전 철탑기초 설계 및 시공 방법 연구 - 심형기초를 중심으로 -)

  • Jang, Suk-Han;Kim, Hee-Kwang;Lee, Kang-Hyeon;Han, Kyung-Soo;Ham, Bang-Wook;Chung, Ki-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1031-1034
    • /
    • 2007
  • Electric transmission lines pass through a variety of area. Foundation supporting the conductors and tower are selected properly in accordance with external load, for example dead load, wind load, snow load, construction load etc, and topography and geology condition. Typical types of foundation are as follows: pad foundation for small load and hard soil or rock in mountainous area, pile foundation for medium or large load and soft soil in plain field area. This paper introduced cylindrical foundation design & construction for large load and mountainous area. This foundation failure mode against pulling-out show splitting failure by tensile force toward circumferential direction.

Verification of LRFD Resistance Factors of Driven Steel Pipe Piles Using a Real Bridge Foundation Design (실제 설계 사례를 통한 항타강관말뚝의 LRFD 저항계수 검증)

  • Park, Jae-Hyun;Lee, Ju-Hyung;Chung, Moon-Kyung;Choi, Young-Seok;Kwak, Ki-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.512-517
    • /
    • 2009
  • Resistance factors for static bearing capacity of driven steel pipe piles were calibrated in the framework of reliability theory. A comprehensive foundation design case study on an actual bridge was performed using resistance factors developed in this study. Comparing with Allowable Stress Design (ASD), LRFD design method provides quantitative evaluation of safety level of designed foundation and exhibits considerable potential economy in design.

  • PDF

A Study on the Behavior of Steel Pipe Subjected to Vertical Load inSand (사질토 지반에서의 강관 말뚝의 수직거동 연구)

  • 김영수;허노영;김병탁;김대만
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.5-13
    • /
    • 2000
  • 모래지반의 상대밀도, 말뚝의 시공방법, 일정근입깊이에 따른 소요향타 에너지 그리고 지하수 조건에 따라 말뚝의 지지력과 하중전이를 연구하기 위하여 강관말뚝을 이용한 모형실험을 수행하였다. 매입말뚝은 말뚝을 미리 설치한후에 지반성형을 실시하였고, 타입말뚝은 매입말뚝과 같은 깊이까지 항타높이를 5, 10, 15cm로 달리하여 말뚝을 관입하였다. 그 뒤 정적하중을 단계적으로 가하여 하중-침하 곡선에 의한 모형 말뚝의 지지력과ㅏ 말뚝내의 등간격으로 설치된 변형 게이지를 이용하여 타입말뚝 의 하중전이에 대해 살펴보았다. 타입말뚝의 하중전이시험에서는 항타 전과 항타 후 말뚝내 하중전의 소효항타 에너지에 따른 변화를 관찰하였다. 매입말뚝의 시험결과는 현재 가장 많이 사용하고 있는 대표적인 정적 지지력 공식들에 의하여 계산되어진 값들과 비교 분석하였다. 그 결과 상대밀도가 작은 느슨한모래지반에서는 Vesic 공식이 그리고 상대밀도가 큰 조밀한 모래지반에서는 Hanbu 공식이 가장 근접한 평가를 나타내었다. 하중전이시험에 의한 항타시 잔류응력은 모든 경우에서 지표면과 선단부위에서 아주 큰 잔류응력이 나타났고. 말뚝의 선단 지지력비는 상대밀도에 비례하게 증가하였다.

  • PDF

Finite Element Analysis of the Load-Displacement Curves of Concrete Piles (콘크리트 말뚝의 하중-변위 곡선에 대한 유한요소해석(지반공학))

  • 정진섭;이대재;이광범
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.438-443
    • /
    • 2000
  • A wide range of problems geotechnical engineering have been analyzed by using the finite element method. In order to establish confidence in a numerical procedure, it is desirable that numerical solution be verified against field or laboratory observations, or both, and in order to aid the user in applying the method to practical problems, it is necessary to examine effects of various parameters that influence the behavior of engineering structures. Often it can be profitable to translate numerical solutions in formats that can be used readily for design analysis. The allowable bearing capacity of concrete piles is mainly governed by settlement rather than by strength of soil. Therefore, the load-displacement behavior of piles should be well understood at the design stage. This paper deals with some of these goals by considering the problem of load-displacement behavior of axially-loaded pile foundations.

  • PDF

Ductility of open piled wharves under reversed cyclic loads

  • Yokota, Hiroshi;El-Bakry, Hazem M.F.
    • Structural Engineering and Mechanics
    • /
    • v.12 no.6
    • /
    • pp.615-632
    • /
    • 2001
  • Ductility of open piled wharves under reversed cyclic loads has been investigated. Experimental testing of five wharf models having a scale of about 1:4 was conducted under the application of horizontal reversed cyclic loading. The experiments were designed to focus on the horizontal ultimate load, ductility and failure mode of the considered wharf models. Nonlinear numerical analyses using the finite element method were also performed on numerical models representing the experimentally tested wharves. The results of the experimental tests showed that open piled wharves possessed favourable ductile behaviour and that their load bearing capacity did not depreciate until a ductility factor of 3 to 4 was reached. The numerical analysis showed that the relative rotation that took place at the joints between the steel piles and the R.C. beam was responsible for a considerable portion of the total horizontal deformation of the wharves. Therefore, it was concluded that introducing the joint stiffness in calculating the deformations of open piled wharves was important to achieve reasonable accuracy.