• 제목/요약/키워드: Piezo-actuator

검색결과 221건 처리시간 0.029초

압전소자 구동장치를 이용한 로봇 손목기구의 개발 (Development of a robot wrist using a piezo actuator)

  • 조영화;문창렬;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.528-532
    • /
    • 1991
  • Having very small linear displacement, piezoelectric actuators have been restricted in robotic application as positioning devices. In this paper, a mechanical amplifier was developed to enhance the displacement of piezoelectric actuator and the corresponding driving circuit was designed. This equipment was integrated as a robotic wrist having 2 D.O.F micropositioning capability. Each joint was analysed in mechanical and dynamic view points. Experimental result showed that this device has Some hysteresis but could be used as vibratory robotic wrist with relatively high frequency. For more fine positioning control, a closed loop approach must be taken into account.

  • PDF

압전소자 밸브 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Pneumatic Valve with Piezoelectric Element)

  • 윤소남;함영복;조정대;유찬수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.828-831
    • /
    • 2003
  • The benefits of the pneumatic valve with piezoelectric element are faster response times, low energy consumption, and the ability to be used in hazardous environments and field bus systems. In this paper, PZT actuator, 2 and 3 stages pneumatic valve were designed and manufactured. Also. characteristics of the pneumatic valve with piezoelectric element were tested with a testing system. It is confirmed that the PZT actuator is useful one for controlling the direction of pilot valve.

  • PDF

AMESim기반 CRDi용 인젝터의 2단분사 동적거동 특성해석 (Analysis of Dynamic Characteristics in Two-stage Injection for CRDi Injectors Based on AMESim Environment)

  • 조인수;권지원;이진욱
    • 한국분무공학회지
    • /
    • 제17권2호
    • /
    • pp.57-63
    • /
    • 2012
  • For reduction of CO, NOx and soot emission emitted by diesel diffusion combustion, the authors focused on injection actuator to improve fuel availability inside combustion chamber. In this study, it was investigated the internal dynamic characteristics of two-stage injection with diesel injectors with different driving type for the common rail direct injection by using the AMESim simulation code. The analysis parameter defined such as fuel pressure, injection hole's diameter and driven voltage. As the results, it was shown that the piezo-driven injector had a faster response and had better control capability than the solenoid-driven injector. It was found the piezo-driven injector can be utilized effectively as multiple injector than solenoid-driven injector.

경량 압전복합재료 곡면형 작동기(LIPCA)의 작동성능 평가를 위한 유한요소 해석 (Finite Element Analysis for Actuating Performance Evaluation of LIghtweight Piezo-composite Curved Acutator)

  • 구남서
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1881-1886
    • /
    • 2001
  • A numerical method for actuating performance evaluation of LIPCA proposed using a finite element method. Fully coupled formulations for piezo-electric materials were introduced and 3-dimensional eight-node incompatible element was used. After verifying the developed code with typical examples, the center deflections of LIPCA were calculated and compared with the experimental result, which were in fairly agreement.

압전세라믹 액추에이터를 이용한 익형 후류 제어 (Control of Flow around an Airfoil Using Piezo-ceramic Actuators)

  • 최진;전우평;최해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.491-496
    • /
    • 2000
  • The objective of this study is to increase lift and decrease drag of an airfoil by delaying flow separation with piezo-ceramic actuators. The airfoil used is NACA 0012 and the chord length is 30cm. An experiment is performed at the freestream velocity of 15m/s at which the Reynolds number is $3{\times}10^5$. Seven rectangular actuators are attached to the airfoil surface and move up and down based on the electric signal. At the attack angle of $16^{\circ}$, the separation point is delayed downstream due to momentum addition induced by the movement of the actuators. Drag and lift are measured using an in-house 2-dimensional load cell and the surface pressures are also measured. Lift is increased by 10%, drag is reduced by 50%, and the efficiency is increased to 170%. The flow fields with and without control are visualized using the smoke-wire and tuft techniques.

  • PDF

능동음향진동제어를 위한 센서와 액추에이터의 동위치화 연구 (Collocation of Sensor and Actuator for Active Control of Sound and Vibration)

  • 이영섭
    • 한국소음진동공학회논문집
    • /
    • 제14권3호
    • /
    • pp.253-263
    • /
    • 2004
  • The problem considered in this paper is about the collocation of sensor and actuator for the active control of sound and vibration. It is well-known that a point collocated sensor-actuator pair offers an unconditional stability with very high performance when it is used with a direct velocity feedback (DVFB) control, because the pair has strictly positive real (SPR) property. In order to utilize this SPR characteristics, a matched piezoelectric sensor and actuator pair is considered. but this pair suffers from the in-plane motion coupling problem with the out-of-plane motion due to the piezo sensor and actuator interaction. This coupling phnomenon limits the stability and performance of the matched pair with DVFBcontrol. As a new alternative, a point sensor and distributed piezoelectric actuator pair is also considered, which provides SPR property in all frequency range when the pair is implemented on a clamped-clapmed beam. The use of this sensor-actuator pair is highly expected for the applications to more practical active control of sound and vibration systems with the DVFB control strategy.

굴곡 진동모드를 이용한 초음파 선형 압전 액추에이터 개발 (Development of ultrasonic linear piezoelectric actuator with flexuralvibration mode)

  • 윤장호;최우천;강종윤;강진규;윤석진
    • 센서학회지
    • /
    • 제18권6호
    • /
    • pp.461-466
    • /
    • 2009
  • This paper represents a piezoelectric ultrasonic linear actuator with flexural vibration mode. The actuator is composed of two piezo ceramics, the elastic body, and the connecting tip. It is driven by the frictional force between the connecting tip and the linear motion guide. Unimorph actuators have flexural vibration. Its middle point is fixed so that suitable to the flexural vibration of $3/2\lambda$. These vibrations contribute to elliptical motion by mixed mode between longitudinal and transverse mode. It was generated when the ultrasonic electrical signals with 90 degree phase difference are applied to two ceramics. A linear movement can be easily obtained using the elliptical motion. The ATILA, FEM simulator has been used to design actuator and verify the kinetic and dynamic analysis. We used the ceramics of $20\times10\times1$ mm size and confirmed the flexural vibration of the $3/2\lambda$ at the 79 kHz through the scanning of 3D-vibrometer. The maximum velocity of actuator was 221 mm/sec and the thrust force of actuator was 2.7 N in 200Vp-p of additional voltage.

Techniques For Control Acoustic Response of Corner-Pinned Rectangular Plate Using Piezo-electric Actuator

  • Jung, Do-Hee;Kim, Woo-Young;Lee, Sang-Kee;Park, Seen-Ok
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제4권2호
    • /
    • pp.79-87
    • /
    • 2003
  • Acoustic response control of a comer-pinned plate using piezoelectric wafers was studied, both theoretically and experimentally. Three different sizes of aluminum alloy plates were used and available ball joints were employed to hold the plate at the four comers. The plate with the largest aspect ratio showed the largest and most clear responses to the acoustic excitation in the range of frequencies (0~200Hz), and sound pressure levels (80~100dB) as predicted. The reduction of the acoustic response of the plate by piezoelectric actuator was very significant, more than expected, but abatement of the sound transmission through the plate was only slightly altered by the piezoelectric actuator. This work is an original work extending earlier work with doors excited by acoustic fields. The important difference is the used of ball joints to simulate the joints.

구동방식이 다른 서보유압형 인젝터의 분사응답성 연구 (Study on Injection Response of Servo-Hydraulic Injector with Different Actuation Method)

  • 권지원;정명철;이진욱
    • 한국분무공학회지
    • /
    • 제18권2호
    • /
    • pp.87-93
    • /
    • 2013
  • In this paper, high-pressure injection characteristic of servo hydraulic injector as the key component of diesel CRDi system, which is driven by solenoid and piezo-actuator were examined by experimental analysis. High-pressure injection characteristic of standard diesel fuel injected at high pressure up to 160 MPa was investigated at high-pressure chamber by using a high-speed camera for spray visualization and quantitative analysis. By this study, we found that the piezo-driven injector has better performances in controlling the fuel injection with the high pressure, including fuel quantity, spray penetration length and spray velocity, than that of a solenoid-driven injector. In particular, the needle response time for start of injection in piezo-driven injector was faster of about $125{\mu}s$ than that of solenoid-driven injector. Consequently, it is known that the piezo-driven injector has more degrees of freedom in controlling the fuel injection with the high pressure than solenoid-driven injector.

마이크로 적층형 압전밸브의 제작과 그 특성 (Fabrication of a Micro Multilayer Piezo Actuator Valve and Its Characteristics)

  • 정귀상;김재민;조상복
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.913-916
    • /
    • 2005
  • This paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramic actuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuator die and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement, respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimized conditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was also bonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 sccm at a supplied voltage of 100 V with a 50 % duty cycle, maximum non-linearity was 2.24 % FS and leak rate was $3.03{\times}10^{-8}pa$. $m^3/cm^2$.

  • PDF