• Title/Summary/Keyword: Pier foundation

Search Result 95, Processing Time 0.028 seconds

Field Test on Rigidities of Piers in High-speed Railway (고속전철 교각의 강성도 산정을 위한 현장실험)

  • 진원종;곽종원;김병석;박성용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.745-750
    • /
    • 2000
  • The rigidity of pier is important in the analysis of rail on high speed railway bridges. This study is being performed because of followings. 1) Actual longitudinal stiffness of the structure including substructure should be considered in the calculation of longitudinal stresses in rails. 2) There are many uncertainties in piers and foundations for design. 3) Actual guideline for the design of piers is necessary. 4) Measurement on the rigidity of pier according to the types of pier, foundation and soil-condition is needed. Curve for rigidity will be obtained through this study and applied for actual design as the guideline. Stresses in rails can be estimates accurately. A pair of piers, which consists of pot-bearing for fixed support and pad-bearing for movable support, is loaded by steel frame through steel wire ropes. The responses which are intended to measure in the field test are displacements, forces and tilts on the top of piers.

  • PDF

Nonlinear Finite Element Analysis of Precast Pier Coping (프리캐스트 교각 코핑부의 비선형 유한요소해석)

  • Cheon, Ju-Hyoun;Kim, Tae-Hoon;Kim, Young-Jin;Shin, Hyun-Mock
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.153-154
    • /
    • 2010
  • For completing an fully optimized and prefabricated substructure system of bridge, developing pier of precast segment PSC which equip the connection structure of shear resistance and precast foundation are conducted previously. Specimens of coping of bridge were developed and customized, and experiments were performed. The result of the experiment through the result from a reliable non-linear analysis program (RCAHEST) were compared and analyzed and evaluated the stability and ultimate behavior of coping of precast pier.

  • PDF

Seismic Fragility of Bridge Considering Foundation and Soil Structure Interaction (교량기초 종류 및 지반-구조물 상호작용을 고려한 지진취약도 분석)

  • Kim, Sun-Jae;An, Hyo-Joon;Song, Ki-il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.129-137
    • /
    • 2020
  • In performing the structural analysis, the foundation is considered to be a fixed end as a plastic hinge model. In this study, the displacements of the foundation, pier, and shoe were compared when the foundation modeled as a fixed end, a shallow foundation constructed on bedrock of 2m depth, and a pile foundation constructed in the 10m to 20m depth of bedrock. The shear force was also compared, and the probability of damage was calculated and compared for the critical condition. When calculated as a fixed end, the displacement of the foundation converged to 0mm, but the shallow foundation built on the bedrock with a depth of 2m caused relatively displacement, and the pile foundation constructed to contact the bedrock with a depth of 18m caused a larger displacement. In addition, it was analyzed that the displacement of the foundation, which is the lower structure, affects the displacement of the super structure, but the difference in shear force applied to the foundation was insignificant in the three cases. There was no difference between the shallow foundation and the pile foundation in the influence on the displacement of the top of the pier, but there was a big difference from the analysis assuming as a fixed end.

Application of Geophysical Results to Designing Bridge over Large Fault (대규모 단층대를 통과하는 교량설계를 위한 물리탐사의 활용)

  • 정호준;김정호;박근필;최호식;김기석;김종수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.245-248
    • /
    • 2001
  • During the core drilling for the design of a railway bridge crossing over the inferred fault system along the river, fracture zone, extends vertically more than the bottom of borehole, filled with fault gouge was found. The safety of bridge could be threatened by the excessive subsidence or the reduced bearing capacity of bedrock, if a fault would be developed under or around the pier foundation. Thus, a close examination of the fault was required to rearrange pier locations away from the fault or to select a reinforcement method if necessary. Geophysical methods, seismic reflection method and electrical resistivity survey over the water covered area, were applied to delineate the weak zone associated with the fault system. The results of geophysical survey clearly showed a number of faults extending vertically more than 50m. Reinforcement was not desirable because of the high cost and the water contamination, etc. The pier locations were thus rearranged based on the results of geophysical surveys to avoid the undesirable situations, and additional core drillings on the rearranged pier locations were carried out. The bedrock conditions at the additional drilling sites turned out to be acceptable for the construction of piers.

  • PDF

Effects of Restrainer upon Bridge Motions with Poundings and frictions under Seismic Excitations (지진시 층돌 및 마찰을 고려한 교량거동에 미치는 Restrainer의 보강효과)

  • 김상효;마호성;이상우;원정훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.291-300
    • /
    • 1999
  • An idealized analytical model is proposed to estimate the effects of restrainer upon global response behaviors of a bridge system under seismic excitations. Pounding actions between adjacent vibration units and friction at movable supports are introduced in addition to other phenomena such as nonlinear behaviors of pier, motions of the foundation and abutment to achieve the better prediction of the bridge motion. The applied restrainer is assumed to be a dead-band system, which has the force clearance and the linear-elastic force. Using the proposed model, the dynamic characteristics of a bridge system retrofitted by restrainers is examined, and the effects of stiffness and clearance length of restrainer is also investigated. The main effect of the application of restrainers is found to reduce the relative displacements and the trend becomes greater with the shorter clearance length except between pier units. It is found that the relative displacements between abutment and adjacent pier units are decreased as the stiffness of restrainer increases, but almost independent upon the stiffness increments of restrainer. However, the relative displacements between pier units tend to be increased due to the applications of the restrainers.

  • PDF

A Case Analysis on the Displacement of Soft Fundation -Kwangyang Industrial Highway- (연약지반의 변위에 대한 사례연구-광양산업도로)

  • 박병기;정진섭
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.03a
    • /
    • pp.43-58
    • /
    • 1994
  • In this reaserch, the comparison between numerical results and field measurments including settlement, heaving and lateral displacement, in the interchange construction works on soft ground. Sand drain was performed for the improvement of the site and steel pipe piles driven for the pier foundation of interchange. The steel pipe piles were replaced to the equivalent steel sheet pile wall. Biot's equation was coupled with elasto-viscoplastic model for the multi-purpose program of soft foundation. Finally countemeasures for future possible lateral displacement and settlement were exmanined.

  • PDF

Analysis on the Influence and Reinforcement Effect of Adjacent Pier Structures according to the Underpass Construction (지하차도 시공에 따른 인접 교각구조물 영향 및 보강효과 분석)

  • Lee, Donghyuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.4
    • /
    • pp.29-39
    • /
    • 2022
  • In order to solve the serious traffic congestion in seoul metropolitan city, large-scale underground space development such as underpasses, deep underground roads, and GTX (Great Train eXpress) is being carried out. In order to minimize the impact of the adjacent seoul metro line A pier foundation and stability due to the construction of the underground road in Seoul, earth retaining structures were reinforced and the foundation was reinforced as well. In this study, three-dimensional finite element mehtod analysis was performed to evaluate the effect on adjacent construction and to review the stability of the underpass excavation work. The reinforcement effect was quantitatively analyzed through numerical analysis. As a result of the analysis, compared to the result of performing the existing reinforcement when overlapping CIP and ground reinforcement grouting were performed, the displacement of the earth retaining structures was reduced by more than 50%, and stress of the foundation piles were also reduced by more than 45%. Based on the analysis of the numerical analysis results, it was confirmed that the displacement of the walls of earth retaining structures during adjacent construction should be strictly controlled.

Nonlinear Analysis with contact element between old and new concrete (Contact 요소를 이용한 신.구 콘크리트의 비선형 해석)

  • Cho, Sun-Kyu;Lee, John-Sun;Jeong, Woo-Cheol;Lee, John-Shin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1050-1055
    • /
    • 2007
  • In the case of a rail road bridge extension work, especially single track to double track, the foundation of new substructure which supports the extended part of superstructure could be interfered by the exist foundation of an old bridge. When these two foundations are jointed to prevent such fatal effects of the structure as unequal subsidence of soil foundations, it is important to prove the structural behaviour of the joining surfaces between new foundation and old foundation. 3-Dimensional Finite Element Analysis Method have been studied for the solutions of the structural behaviour of the foundations. In this analysis, 'Contact Element' which allows the sliding of each adjoining member is used for the joint of the boundary surface of the old and new pier foundations. Furthermore, Material Nonlinear Behaviour Analysis also supports the accuracy of the result in this study because the foundations consist of concrete main bodies and reinforced steel bars. These detailed analyses secure the verification of the structural safety of the foundations in the extension work more firmly.

  • PDF

Finite Element Analysis Reinforced Concrete Slab Bridge Considering Elastic deformations of Reinforced Concrete T-type Piers (T형 교각의 탄성변형을 고려한 슬래브교의 유한요소 해석)

  • 이성철;윤동열
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.100-110
    • /
    • 2000
  • In practical design of girder bridges or reinforced concrete slab bridges with T-type piers, it is usually assumed that vertical movements of superstructures are completely restrained at the locations of bearings(shoes) on a cap beam of the pier, The resulting vertical reactions are applied to the bearing for the calculation of bending moments and shear forces in the cap beam. However, in reality, the overhang parts of the cap beam will deform under the dead load of superstructures and the live load so that it may act as an elastic foundation. Due to the settlement of the elastic foundation, the actual distribution of the reactions at the bearings along the cap beam may be different from that obtained under the assumption that the vertical movements are fixed at the bearings. In the present study, investigated is the effects of elastic deformations of the T-type pier on the distribution of reactions at the bearings along the cap beam through 3-dimensional finite element analysis. Herein, for this purpose the whole structural system including the superstructure and piers as well is analyzed. It appears that the conventional practice which neglects the elastic deformations of the cap beam exhibits considerably different distributions of the reactions as compared with those obtained from the present finite element analysis. It is, therefore, recommended that in order to assess the reactions at bearings correctly the whole structural system be analyzed using 3-dimensional finite element analysis.

  • PDF

Study on safety early-warning model of bridge underwater pile foundations

  • Xue-feng Zhang;Chun-xia Song
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.2
    • /
    • pp.107-116
    • /
    • 2023
  • The health condition of of deep water high pile foundation is vital to the safe operation of bridges. However, pier foundations are vulnerable to damage in deep water due to exposure to sea torrents and corrosive environments over an extended period. In this paper, combined with aninvestigation and analysis of the typical damage characteristics of main pier group pile foundations, we study the safety monitoring and real-time early warning technology of the deep water high pile foundations, we propose an early warning index item and early warning threshold of deep water high pile foundation by utilizing a numerical simulation analysis and referring to domestic and foreign standards and literature. First, we combine the characteristics of structures and draw on more mature evaluation theories and experience in civil engineering-related fields such as dam and bridge engineering. Then, we establish a scheme consisting of a Early Warning Index Systemand evaluation model based on the analytic hierarchy process and constant weight evaluation method and apply the research results to a project based on the Jiashao bridge in Zhejiang province, China. Finally, we verify the rationality and reliability of the Early Warning Index Systemof the Deep Water High Pile Foundations.