• Title/Summary/Keyword: Picture archiving and communication system (PACS)

Search Result 83, Processing Time 0.026 seconds

Assessment of Lumbar Spine Kinematics by Posterior-to-Anterior Mobilization

  • Oh, Kang O;Lee, Sang-Yeol
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.4
    • /
    • pp.450-456
    • /
    • 2021
  • Objective: Studies confirming the lumber spine kinematics of direct or indirect segmental mobility under the application of joint mobilization, which induces passive force on the spine, are insufficient.Therefore, this study aims to obtain the underlying clinical data by identifying direct or indirect segmental mobility produced by Maitland's PA mobilization technique. Design: Randomized controlled trial design. Methods: Thirty subjects with no back pain participated in this study. X-ray testing equipment (SIG-40-525, Ecoray Inc., Korea) was used to verify the segmented movement of their lumbar. Joint mobilization was performed by physiotherapists with more than 10 years of experience in prescription therapy, and radiography was performed once without PA joint mobilization and once without the mobilization for comparing the lumbar vertebrae before and after the mobilization. The radiographs taken were analyzed using the picture archiving and communication system (PACS) program to measure the spinal displacement, intervertebral height, intervertebral angle, and lumbar lordosis angle. Results: Significant differences were observed in the lumbar displacement, intervertebral angle, and lumbar lordosis angle in all lumbar vertebrae before and after the mobilization. The intervertebral height indicated significant differences in all ventral vertebrae and only in L3-L4 and L4-L5 in dorsal vertebrae. Conclusions: This study suggests that the segmental mobility produced through indirect approaches plays an important role in inducing therapeutic effects in patients with back pain.

Kinetic Analysis on the Lumbar at the Trunk Flexion according to the Degree of Hamstring Flexibility of Healthy Adult (정상 성인의 슬괵근 유연성 정도에 따른 체간 굴곡시 요추의 운동학적 분석)

  • Kim, Gi-Chul;Hwang, Bo-Gak
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.4
    • /
    • pp.501-507
    • /
    • 2012
  • PURPOSE: This study aims to examine the effects of trunk flexion on the kinetic characteristics of the lumbar according to the degree of hamstring flexibility. METHODS: This study has as its subjects 29 young adults and divides them into the group (NSRTG, n=15) with the normal length of hamstrings according to SRT and the group (SSRTG, n=14) tending to have shortened hamstrings. Sit and Reach Test was conducted to evaluate the degree of hamstring flexibility. And to examine the kinetic difference of the lumbar at the trunk flexion, it was compared and analyzed by using the picture archiving and communication system (PACS). RESULTS: SSRTG showed more significant difference than NSRTG in the analysis on the trunk flexion of NSRTG and SSRTG. CONCLUSION: According to the analysis, the shortening of hamstrings is the factor that affects the dynamic stability of the lower lumbar through the reduction of the pelvic anterior tilt at the trunk flexion.

Correlation between lumbar spinal stenosis and bone mineral density : a clinical survey of 9 cases (요추관 협착증과 골밀도와의 상관성에 관한 임상례 보고)

  • Song, Joo-Hyun;Kang, In;Im, Myung-Jang;Kim, Ha-Neul;Lee, Je-Kyun;Jang, Hyoung-Seok
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.1 no.1
    • /
    • pp.105-111
    • /
    • 2006
  • Objective : The aim of this study was to evaluate association between lumbar spinal stenosis, one of degenerative diseases, and bone mineral density. Methods : We monitored 9 lumbar spinal stenosis patients in women above 50 years, visiting outpatient clinic of the Jaseng Oriental Medicine Hospital between January 5 2006 and March 31, 2006. They were diagnosed by radiologist ist after taking Magnetic Resonance Imaging(MRI). The cases were Investigated the bone mineral density using Dual Energy X-ray Absorptiomerty(DEXA). and then Picture Archiving Communication System(PACS) were used to assess correlation between lumbar spinal stenosis and bone mineral density. Results : 1. In comparison of the spinal canal area and lumbar spine 2 level bone mineral density, the data showed a significant result 2. The data, between spinal canal area and lumbar spine 1-2 level bone mineral density, indicated a significant result. 3. Also, the result of comparison between spinal canal area and the lowest value of bone mineral density showed significance. Conclusions : It showed that there is a statistically significant correlation between lumbar spinal stenosis and bone mineral density.

  • PDF

Comparison of Interpretations between Digital Image and Analogue Image in Liver Scintigraphy (간신티그라피에서 Digital Image와 Analogue Image 판독의 비교)

  • Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Park, Seok-Gun;Lee, Myung-Hae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.195-200
    • /
    • 1989
  • The authors studied to evaluate the difference of the diagnostic performance between reading from digital image on the video CRT of PACS (Picture Archiving and Communication System) and from analogue image of conventional film mode. We compared interpretative accuracy of above two reading modes by having two observers read a series of liver scintigrams. Images were read once from film and a second time from video CRT of elementary PACS. The concordance rate of interpretation of the two modes was in the range from 61.0% to 93.2%. The diagnostic accuracies of digital image reading and analogue image reading were 72.9% and 74.6% respectively in one observer, and 72.9% and 76.3% in another one. No significant difference in interpretative accuracy could be found between two modes of reading.

  • PDF

Digital Watermarking of Medical Image Based on Public Key Encryption Algorithm Considering ROI (ROI를 고려한 공개키 암호화 알고리즘 기반 의료영상 디지털 워터마킹)

  • Lee Hyung-Kyo;Kim Hee-Jung;Seong Tack-Young;Kwon Ki-Ryong;Lee Jong-Keuk
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.11
    • /
    • pp.1462-1471
    • /
    • 2005
  • Recently, the medical image has been digitized by the development of computer science and digitization of the medical devices. There are needs for database service of the medical image and long term storage because of the construction of PACS(picture archiving and communication system) following DICOM(digital imaging communications in medicine) standards, telemedicine, and et al. However, it also caused some kinds of problems, such as illegal reproduction of medical image, proprietary rights and data authentication. In this paper, we propose the new digital watermarking technique for medical image based on public key encryption algorithm for integrity verification. It prevents illegal forgery that can be caused after transmitting medical image data remotely. The watermark is the value of bit-plane in wavelet transform of the original image for certification method of integrity verification. We proposed the embedding regions are randomly chosen considering ROI, and a digital signature is made using hash function of MD5 which input is a secret key. The experimental results show that the watermark embedded by the proposed algorithm can survive successfully in image processing operations and that the watermark's invisibility is good.

  • PDF

A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom (ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.241-247
    • /
    • 2006
  • Recently, interests and utilization on Computed Radiography(CR) and Digital Radiography(DR) tends to increase owing to an introduction of Picture Archiving and Communication System(PACS) and an accuracy control of special medical equipment for a breast imaging examination. This study was intended to compare and analyze a detector's imaging quality by each system to be used for the breast imaging examination by using ACR Phantom used at the accuracy control. As an evaluation method, a significance and reliability of image's value using the ACR Phantom was analyzed by using SPSS program. The results are followed. 1. For the fiber, there was 3.9 score in Screen-Film, 4.2 score in CR($50{\mu}m$), 3.2 score in CR($100{\mu}m$), and 4.2 score in DR. There was the high score in the order of CR($50{\mu}m$), DR, Screen-Film, and CR($100{\mu}m$)(P<0.05). 2. For the calcification, there was 2.7 score in Screen-Film, 2.5 score in CR($50{\mu}m$), 2.0 score in CR($100{\mu}m$), and 2.9 score in DR. There was the high score in the order of DR, Screen-Film, CR($50{\mu}m$), and CR($100{\mu}m$).(0.025(P<0.05). 3. For Mass, there was 3.8 score in Screen-Film, 3.8 score in CR($50{\mu}m$), 3.6 score in CR($100{\mu}m$), and 4.5 score in DR. There was the high score in the order of DR, CR($50{\mu}m$), Screen-Film, and CR($100{\mu}m$) (P<0.1). 4. As the total score, there was 10.4 score in Screen-Film, 10.6 score in CR($50{\mu}m$), 8.7 score in CR($100{\mu}m$), and 11.3 score in DR. There was the high score in the order of DR, $CR(50{\mu}m$), Screen-Film, and $CR(100{\mu}m$). As shown in the above results, it can be known that DR and Screen-Film System has higher image quality than CR. But, DR has unstability caused by element, and Screen-Film has the low image quality caused by artifact as disadvantages. When Dual-Side CR($50{\mu}m$) was used among CR systems which had the problem of low image quality, it was indicated that there was no difference with Screen-Film System. Because the radiation imaging examination tends to become digitalized, each system for the breast imaging examination will need to be developed and supplemented.

  • PDF

A study on the optimization of referring method about medical images using MIH(Medical Image History) (MIH(Medical Image History)을 이용한 의료영상조회의 최적화 연구)

  • Kim, Sun-Chil;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.57-64
    • /
    • 2002
  • The recent development of embodiment technology of the medical images makes most medical institutions introduce PACS(Picture Archiving and Communication System) in haste. However lots of PACS solutions, currently developed and distributed, haven't been able to serve the convenience of users and to satisfy user's demand because of economic limitations and administrator-oriented considerations in the process of development. So we have developed MIH(Medical Image History), by which we can search and refer to the patient's medical images and information with few restrictions of time and space for diagnosis and treatment. This program will contribute to the improvement in the medical environment and meet the clients' need. We'll make more effort to develop the application which insures the better quality of medical images. MIH manages the patient's image files and medical records like film chart in connection with time. This trial will contribute to the reduction of the economical loss caused by unnecessary references and improve the quality in the medical services. The demand on the development or the program which refers to the medical +ata quickly and keeps them stable will be continued by the medical institute. This will satisfy the client's demand and improve the service to the patients in that tile program will be modified from the standpoint of the users. MIH is trying to keep user-oriented policy and to apply the benefit of the analog system to the digital environment. It is necessary to lead the public to the better understanding that the systematic management and referring of the medical images is as important as the quality of the images.

  • PDF

Development of JPEG2000 Viewer for Mobile Image System (이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발)

  • 김새롬;정해조;강원석;이재훈;이상호;신성범;유선국;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.124-130
    • /
    • 2003
  • Currently, as a consequence of PACS (Picture Archiving Communication System) implementation many hospitals are replacing conventional film-type interpretations of diagnostic medical images with new digital-format interpretations that can also be saved, and retrieve However, the big limitation in PACS is considered to be the lack of mobility. The purpose of this study is to determine the optimal communication packet size. This was done by considering the terms occurred in the wireless communication. After encoding medical image using JPGE2000 image compression method, This method embodied auto-error correction technique preventing the loss of packets occurred during wireless communication. A PC class server, with capabilities to load, collect data, save images, and connect with other network, was installed. Image data were compressed using JPEG2000 algorithm which supports the capability of high energy density and compression ratio, to communicate through a wireless network. Image data were also transmitted in block units coeded by JPEG2000 to prevent the loss of the packets in a wireless network. When JPGE2000 image data were decoded in a PUA (Personal Digital Assistant), it was instantaneous for a MR (Magnetic Resonance) head image of 256${\times}$256 pixels, while it took approximately 5 seconds to decode a CR (Computed Radiography) chest image of 800${\times}$790 pixels. In the transmission of the image data using a CDMA 1X module (Code-Division Multiple Access 1st Generation), 256 byte/sec was considered a stable transmission rate, but packets were lost in the intervals at the transmission rate of 1Kbyte/sec. However, even with a transmission rate above 1 Kbyte/sec, packets were not lost in wireless LAN. Current PACS are not compatible with wireless networks. because it does not have an interface between wired and wireless. Thus, the mobile JPEG2000 image viewing system was developed in order to complement mobility-a limitation in PACS. Moreover, the weak-connections of the wireless network was enhanced by re-transmitting image data within a limitations The results of this study are expected to play an interface role between the current wired-networks PACS and the mobile devices.

  • PDF

An Efficient Medical Image Compression Considering Brain CT Images with Bilateral Symmetry (뇌 CT 영상의 대칭성을 고려한 관심영역 중심의 효율적인 의료영상 압축)

  • Jung, Jae-Sung;Lee, Chang-Hun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.39-54
    • /
    • 2012
  • Picture Archiving and Communication System (PACS) has been planted as one of the key infrastructures with an overall improvement in standards of medical informationization and the stream of digital hospitalization in recent days. The kind and data of digital medical imagery are also increasing rapidly in volume. This trend emphasizes the medical image compression for storing large-scale medical image data. Digital Imaging and Communications in Medicine (DICOM), de facto standard in digital medical imagery, specifies Run Length Encode (RLE), which is the typical lossless data compressing technique, for the medical image compression. However, the RLE is not appropriate approach for medical image data with bilateral symmetry of the human organism. we suggest two preprocessing algorithms that detect interested area, the minimum bounding rectangle, in a medical image to enhance data compression efficiency and that re-code image pixel values to reduce data size according to the symmetry characteristics in the interested area, and also presents an improved image compression technique for brain CT imagery with high bilateral symmetry. As the result of experiment, the suggested approach shows higher data compression ratio than the RLE compression in the DICOM standard without detecting interested area in images.

Physical principles of digital radiographic imaging system (디지털 방사선영상 시스템의 기본적 원리)

  • Choi, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.