• Title/Summary/Keyword: Physical shape

Search Result 1,342, Processing Time 0.027 seconds

Treatment of Patients With Elephantiasis Lymphedema - Case Report - (상피성 임파부종 환자의 치료 -증례보고-)

  • Kim, Seng-Jung
    • Physical Therapy Korea
    • /
    • v.6 no.3
    • /
    • pp.110-120
    • /
    • 1999
  • Lymphedema, regardless of etiology, is essentially incurable but different treatment approaches which serve to contain swelling exist. The objectives of treatment are to reduce swelling, restore shape, educate about the self-maintenance methods, and prevent inflammatory episodes, eg, recurrent cellulitis. The purpose of this report is to provide therapists and other medical staff with a general guideline through the example treatment procedure of two patients with lymphedema admitted to Samsung Medical Center. This study demonstrates the effects of the various treatments used and how they helped to achieve improvement in mobility and reduction in swelling of the lower limbs. The basic conservative treatments were sequential intermittent pneumatic pumps, elevation, and CDP (complex decongestive physiotherapy). The surgical procedures (Homan's operation) were carried out after maximal volume reduction through conservative programs. In these cases, we can see greater than 50% reduction in the lymphedema in those treated by conservative and surgical procedures. This presents a simple, reliable, variable method yielding satisfactory cosmetic and functional results for patients suffering from chronic both-leg lymphedema. Futhermore, I suggest that the outcomes are best when treatment is administered by a multidisciplinary team including a physiotherapist, surgeon, nurse, et al.

  • PDF

The effects of aqua-exercise on the muscle atrophy of hind limb in rats

  • Cho sun-yeo
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.3
    • /
    • pp.373-406
    • /
    • 2002
  • This study was peformed to investigate the effects on skeletal muscle recovery with aqua-exercise; swimming to take the muscle endurance for 20 days on two group of white rats which were the low extremity atrophy group(control groups) by fixed for two weeks and aqua-exercise group(experimental groups) after it. The effects was observed with light and electron microcope to measure the morphological changes of muscle fibers. The results obtained were as follow. 1. Light microscope: In the case of control groups, quadriceps fibers had been irregular alignment, decreased muscle width and the irregular alignment nuclear appeared, as it is degenerative muscle fibers. In the case of experimental groups, the fibers had been regular alignment cells and fibers. The nucleus of muscle had been normal characterized by oval shape and fiber sarcomere clearly classified. 2. Electron microscope: In the case of control groups, there were the quadriceps which was Z-line streaming phenomenon induced at the sarcomere and cells nuclear separated from basal membrane. It was not only observed the sarcomere alignment irregularly and mitochondria damaged, but also vacuoles found. In the case of experimental groups, A band, I band, H band had been clearly appeared, classified at the myofibrils of quadriceps, and electronic dense M-line found in sarcomere. There were observed satellite cells and basal laminas that usually to be appeared at the time of mitochondrial development, skeletal muscle fiber regeneration or development. This results suggest that the aqua-exercise assisted to inhibit the degenerative morphological changes of skeletal muscle cells and help to recover from abnormal states. Especially, it is considered to effect on a normal structural formation.

  • PDF

A Morphological Study on the Changes in Rat's Gastrocnemius (쥐의 비복근 섬유의 변화에 대한 형태학적 연구)

  • Huh Yang-Hoon;Choi Jae-Cheong
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.2
    • /
    • pp.71-76
    • /
    • 1998
  • Twelve Spraque-Dawley healthy male rats(average weight ; 250g)were used to study the morphological changes of mitochondria, myofibril, muscle cell nucleus, triad. They were devided into 3 groups : normal daily activity (Group 1), 2weeks immobilization (Group 2), 4 weeks immobilization(Group 3). Left ankle of Group 2 and 3 were immobilized with plaster cast in $65^{\circ}$ plantarflexed position. The gastrocnemius were removed from 12 rats. Muscle fibers were observed electronmicroscopically by double staining with uranyl acetate and lead citrate, All the variables of Group 2 and 3 that selected in this study were significantly decreased when decreased with control value (p<.05) but also muscle fibers showed extensive damage, characterized by irregularity of mitochondrias and wide separation of myofibrils. irregularity and thinness of myofilaments and abnormal shape of muscle cell nucleus and unclear triad. Especially, sarcomere length of Group 3 were singnificantly decreased when compared with Group 2(p<.01).

  • PDF

The Physical Properties and Dyeability of KOH Treated Cotton Fabrics (KOH 처리 면직물의 물성 및 염색성)

  • Song, Hyun-Joo;Kim, Su-Mi;Song, Wha-Soon
    • The Korean Fashion and Textile Research Journal
    • /
    • v.7 no.1
    • /
    • pp.91-95
    • /
    • 2005
  • The purpose of this study is to investigate the improvement of fiber surface, physical properties and research the physical properties and dyeability of cotton fabrics treated with KOH solution at low and high temperature. The treatment conditions for mercerization with KOH were changed various temperatures(25, $90^{\circ}C$), concentrations(15, 20, 25, 30%. w/v) and times(30, 60, 180, 300sec). The effects of mercerization after KOH treatment estimated with tensile strength, tearing strength, shrinkage, drape stiffness, moisture regain, fiber surface, and dyeability. The optimal conditions were concentration of KOH 20%, time 180sec in low temperature and concentration of KOH 20%, time 60sec in high temperature. The results are as follows; Tensile strength, tearing strength and moisture regain were much improved than those of untreated cotton fabric. Shrinkage and drape stiffness of KOH treated cotton were more increased at $25^{\circ}C$ than $90^{\circ}C$. Fiber surface showed more rounded shape at $25^{\circ}C$ than $90^{\circ}C$. Dyeability of cotton fabrics improved by KOH treatment.

The Physical Property of PET Coolness Knitted Fabric for High Emotional Garment (고감성 의류용 PET 냉감 니트 소재의 물성)

  • Kim, Hyun Ah;Woo, Ji Yoon;Kim, Seung Jin
    • Textile Coloration and Finishing
    • /
    • v.26 no.2
    • /
    • pp.114-123
    • /
    • 2014
  • This research investigated the physical properties of PET coolness filaments and their knitted fabrics including dyeing characteristics of these knitted fabrics according to the different dyeing time and temperature. The coolness filament(S) with non-circular cross-section and hydrophilic property was spun and another commercialized coolness(A) and regular(R) PET filaments were prepared for comparing coolness and another physical properties. Qmax of coolness knitted fabric made with S filament was higher than that of R-PET filament, and the maximum value of Qmax of S knitted fabric was shown at the dyeing conditions of temperature, $110^{\circ}C$ with 30 min. or 40min. It was shown that hand of S knitted fabric was a little harsh comparing to A and regular knit specimens, but shape retention and wearing performance of garment made with S knit specimen were estimated as good owing to high bending and shear rigidity. K/S of S knitted fabric was higher than those of regular PET and A knit specimens. Dyeing fastness of coolness knitted fabric showed between 4th and 5th grade.

Equivalence Principles Based Skin Deformation of Character Animation

  • You, L.H.;Chaudhry, E.;You, X.Y.;Zhang, Jian J.
    • International Journal of CAD/CAM
    • /
    • v.9 no.1
    • /
    • pp.61-69
    • /
    • 2010
  • Based on the equivalence principles of physical properties, geometric properties and externally applied forces between a surface and the corresponding curves, we present a fast physics and example based skin deformation method for character animation in this paper. The main idea is to represent the skin surface and its deformations with a group of curves whose computation incurs much less computing overheads than the direct surface-based approach. The geometric and physical properties together with externally applied forces of the curves are determined from those of the surface defined by these curves according to the equivalence principles between the surface and the curves. This ensures the curve-based approach is equivalent to the original problem. A fourth order ordinary differential equation is introduced to describe the deformations of the curves between two example skin shapes which relates geometric and physical properties and externally applied forces to shape changes of the curves. The skin deformation is determined from these deformed curves. Several examples are given in this paper to demonstrate the application of the method.

Influense of the high-voltage conductivity on peculiarity of polarization ferroelectric polymer on based vinylidenefluoride

  • Kochervinskii, V.V.;Chubunova, E.V.;Lebedinskii, Y.Y.;Pavlov, A.S.;Pakuro, N.I.
    • Advances in materials Research
    • /
    • v.4 no.2
    • /
    • pp.113-132
    • /
    • 2015
  • The phenomena of high-voltage polarization and conductivity in oriented vinylidenefluoride and tetrafluoroethylene copolymer films have been investigated. It was shown that under certain electric fields, injection of carriers from the material of electrodes appears The barrier for holes injection in the copolymer was found to be lower than that for electrons. It results in more effective screening of the external field near the anode than near cathode. Electrones, ejected from cathode, creating negative charge by trapping on the surface. It is shown that the electrons injected from cathodes create a negative homocharge on the copolymer surface and then become captured on the surface shallow traps. Their nature has been studied by the x-ray photoelectron spectroscopy. It was shown that these traps may consist of chemical defects in the form of new functional groups formed by reactions of surface macromolecules with sputtered atoms of aluminum. The asymmetric shape of hysteresis curves was explained by the difference in mobility of injected holes and electrons. These factors caused appearance of "non-closed" hysteresis curves for fluorine-containing polymer ferroelectrics. Hysteresis phenomena observed at low electric fields (below coercive ones) are to associate with the behavior of the domains localized in the ordered regions formed during secondary crystallization of copolymers.

The Physical Properties and Dyeability of the Degummed and Sericin Fixed Silk Fabrics (정련 및 세리신 정착처리 견직물의 물리적 성질과 염색성)

  • 이은미;이혜자;유혜자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.5
    • /
    • pp.517-523
    • /
    • 2003
  • We studied the physical properties of silk fabrics after degumming, the dyeability and the color fastness of silk fabrics after degumming and sericin fixing. As the sericin was removed from silk fabrics, the rate of weight loss increased and both the abrasion resistance and the drape coefficient decreased. This means that the amount of the sericin remained in silk fabrics significantly affects the physical properties of silk fabrics. On the surface and the cross-section of silk fabrics, the silk fibers enclosed by the sericin seemed to be in a lump shape. Each fibroin strand, however, got scattered, as the process of degumming went through. The dyeability of silk fabrics degummed decreased at between 20$^{\circ}C$∼80$^{\circ}C$ the dyeing temperature, on the other hand, it significantly increased over 80$^{\circ}C$. The dyeability of the sericin-fixed silk fabrics was lower than that of the non-serin-fixed silk fabrics, to a little extent. The colorfastness of crocking in the dyed-silk fabrics was a little low and that of the sweat was much lower in a basic sweat. Especially, the colorfastness of the partially degummed silk fabrics was low, because the sericin was not stable in the condition of sweat. Therefore, the process of sericin fixing is essentially required, for the partially degummed silk fabrics and the process of degumming itself.

Spiral Taping Improves Performance on Star Excursion Balance Test in Individuals with Unilateral Chronic Ankle Instability

  • Bae, Young-Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.6
    • /
    • pp.376-380
    • /
    • 2016
  • Purpose: This study was to investigate the short-term effects of spiral taping (ST) on performance on the star excursion balance test (SEBT) in individuals with unilateral chronic ankle instability (CAI). Methods: This study was single-group pre - post measures experimental design. The subjects with CAI were 39 (range, 20-31 years; male 16, females 23) were enrolled in the study. The discomfort had in unilateral ankle and Cumberland ankle instability score was 19.56 (${\pm}3.29$). Spiral tape (a width of 3 mm) was applied $3{\times}4$ cross shape on medial malleolus, lateral malleolus and dorsal of talocural joint of unstable ankle. SEBT was measured baseline and 30 min later in stable ankle and unstable ankle. Results: SEBT showed significantly improved after applying the ST (p<0.05, ES=0.74) on unstable ankle. In comparison the difference of stable and unstable ankle, between the pretest and posttest were significant differences (p<0.01, ES=1.88). Conclusion: These results indicated that ST improves performance on the SEBT. Therefore, it suggests that ST may be a suitable intervention to dynamic balance in patients with CAI.

Development and validation of a numerical model for steel roof cladding subject to static uplift loads

  • Lovisa, Amy C.;Wang, Vincent Z.;Henderson, David J.;Ginger, John D.
    • Wind and Structures
    • /
    • v.17 no.5
    • /
    • pp.495-513
    • /
    • 2013
  • Thin, high-strength steel roof cladding is widely used in residential and industrial low-rise buildings and is susceptible to failure during severe wind storms such as cyclones. Current cladding design is heavily reliant on experimental testing for the determination of roof cladding performance. Further study is necessary to evolve current design standards, and numerical modelling of roof cladding can provide an efficient and cost effective means of studying the response of cladding in great detail. This paper details the development of a numerical model that can simulate the static response of corrugated roof cladding. Finite element analysis (FEA) was utilised to determine the response of corrugated cladding subject to a static wind pressure, which included the anisotropic material properties and strain-hardening characteristics of the thin steel roof cladding. The model was then validated by comparing the numerical data with corresponding experimental test results. Based on this comparison, the model was found to successfully predict the fastener reaction, deflection and the characteristics in deformed shape of the cladding. The validated numerical model was then used to predict the response of the cladding subject to a design cyclone pressure trace, excluding fatigue effects, to demonstrate the potential of the model to investigate more complicated loading circumstances.