• 제목/요약/키워드: Physical conditioning

검색결과 181건 처리시간 0.024초

공동주택 세대별 난방 성능 개선 연구 (A Study on Improved Heating Performance of an Apartment Housing Unit)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

W CMP 공정에서의 연마패드표면 안정화 상태와 그 개선 (Stability and Improvement of Polishing Pad in W CMP)

  • 박재홍;키노시타 마사하루;요시다 코이치;신이치 마츠무라;정해도
    • 한국전기전자재료학회논문지
    • /
    • 제20권12호
    • /
    • pp.1027-1033
    • /
    • 2007
  • In this research, the polishing pad for W CMP has been analyzed to understand stabilization of polishing performance. For stabilization of process, the polishing pad condition is one of important factors. The polishing pad plays a key role in polishing process, because it contact with reacted surface of wafer[1]. The physical property of pad surface is ruled by conditioning tool which makes roughness and profile of pad surface. Pad surface affects on polishing performance such as RR(Removal Rate) and uniformity in CMP. The stabilized pad surface has stable roughness. And its surface has high level of wettability which can increase the probability of abrasive adhesion on pad. The result of this research is that the reduction of break-in and dummy polishing process were achieved by artificial machining to make stable pad surface. In this research, urethane polishing pad which is named IC pad(Nitta-Haas Inc.) and has micro pore structure, is studied. Because, this type of pad is the most conventional type.

난류 대류를 도입한 고온 축열 시스템 모델의 열복사 전달에 관한 연구 (Combined Thermal Radiation with Turbulent Convection Conjugate PCM Model)

  • 김광선
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.556-565
    • /
    • 1995
  • The physical model of interest is based upon the concentric cylinder, where the outside cylinder is filled with optically thick and high temperature phase change material(PCM). The fluid is flowing through the inside cylinder to transfer the appropriate energy. The fluid is flowing through the inside cylinder to transfer the appropriate energy. The governing equations for the phase change material including internal thermal radiation and for the turbulent transfer fluid have been employed and numerically solved. The optically thick phase change justifies the P-l spherical harmonics approximation, which is believed to be appropriate choice particularly for the much coupled problem like in this study. The solid/liquid interface, temperature distribution within the PCM and the heat flux from the PCM to the transfer fluid have been obtained and compared with those of laminar transfer fluid. The numerical results show that the turbulent transfer fluid accelerates the solid/liquid interface and results in the increase of heat transfer rate from the PCM. The internal thermal radiation within the PCM, however, does not always playa role to increase the heat transfer rate throughout the inside cylinder. It is believed that the combined heat flux has been picked up more in the inflowing area than in the pure conductive phase change material.

  • PDF

휜형 원형관의 형상 최적화를 위한 다목적 전역 최적화 기법의 응용 (An Application of Multi-Objective Global Optimization Technique for Internally Finned Tube)

  • 이상환;이주희;박경우
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.938-946
    • /
    • 2005
  • Shape optimization of internally finned circular tube has been peformed for periodically fully developed turbulent flow and heat transfer. The physical domain considered in this study is very complicated due to periodic boundary conditions both streamwise and circumferential directions. Therefore, Pareto frontier sets of a heat exchanger can be acquired by coupling the CFD and the multi-objective genetic algorithm, which is a global optimization technique. The optimal values of fin widths $(d_1,\;d_2)$ and fin height (H) are numerically obtained by minimizing the pressure loss and maximizing the heat transfer rate within ranges of $d_1=0.2\sim1.5\;mm,\;d_2=0.2\sun1.5\;mm,\;and\;H=0.2\sim1.5\;mm$. The optimal values of the design variables are acquired after the fifth generation and also compared to those of a local optimization algorithm for the same geometry and conditions.

입.출구의 압력조건에 따른 보텍스 튜브의 에너지분리 특성에 관한 실험적 고찰 (Experimental Investigation for the Characteristics of Energy Separation of a Vortex Tube at Various Inlet and outlet Pressure Conditions)

  • 유갑종;김정수;최인수
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1149-1155
    • /
    • 2001
  • The experimental investigation on energy separation in a vortex tube has been carried out to sow the effect of inlet and outlet pressures with various working fluids(air,$O_2,\;and\; CO_2$). Those outlet pressure means cold outlet and hot outlet pressure which were set equally. The results showed that the total enthalpy variation became a maximum when the mass flow rate at the cold outlet was a half of the total mass flow rate in the vortex tube (y=0.5). The total enthalpy variation was quite affected by the pressure difference between the inlet and outlet of vortex tube when the ratio of the inlet pressure to the cold outlet pressure remained constant. Although specific enthalpy differences between the inlet and the outlet (both cold and hot outlet) did not noticeably vary with the pressure difference, the specific enthalpy difference between the inlet and cold outlet was dominantly affected by physical properties of working gases.

  • PDF

석탄(石炭)의 유동층(流動層) 연소(燃燒)에 관(關)한 S. ENDRENYI와 B. PALANCZ의 수학적(數學的) 수정(修正)모델(비표면적(比表面積) 변화(變化)의 영향(影響)) (Modified Mathermatical Model of S. ENDRENYI and B. PALANCZ for Fluidized Bed Coal Combustion - Effect on the Variation of Specific Surface -)

  • 김명준;이관석;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제17권1호
    • /
    • pp.74-82
    • /
    • 1988
  • A numerical analysis of the mathematical model for fluidized bed coal combustion has been performed. Based on the physical nature of the specific surface variation due to the decreasing of coal particle diameter according to the combustion process, the modified model which has been added the specific surface variation to the S.ENDRENYI and B.PALANCZ's mathematical model was established in this study. From the numerical analysis of these two models, it was found that the perfect combustion time is increasing largely at least 5 seconds in the modified model in comparison with that of the S.ENDRENYI and B.PALANCZ's model, and the bed temperature and the coal particle surface temperature during the main combustion period represent constant with time in the S.ENDRENYI and B.PALANCZ's model, on the other hand, these properties are decreasing linearly with time in the modified model.

  • PDF

메탄 하이드레이트 생성을 위한 THF와 산화 탄소나노튜브의 영향에 대한 비교 연구 (A Comparative Study on the Effect of THF and Oxidized Carbon Nanotubes for Methane Hydrate Formation)

  • 박성식;안응진;김남진
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.769-775
    • /
    • 2011
  • Methane hydrate is formed by physical binding between water molecules and methane gas, which is captured in the cavities of water molecules under the specific temperature and pressure. $1m^3$ hydrate of pure methane can be decomposed to the methane gas of $172m^3$ and water of $0.8m^3$ at standard condition. Therefore, there are a lot of practical applications such as separation processes, natural gas storage transportation and carbon dioxide sequestration. For the industrial utilization of hydrate, it is very important to rapidly manufacture hydrate. So in this study, hydrate formation was experimented by adding THF and oxidized carbon nanotubes in distilled water, respectively. The results show that when the oxidized carbon nanofluids of 0.03 wt% was, the amount of gas consumed during the formation of methane hydrate was higher than that in the THF aqueous solution. Also, the oxidized carbon nanofluids decreased the hydrate formation time to a greater extent than the THF aqueous solution at the same subcooling temperature.

팬을 부착한 이중외피의 이론적 검토 및 적용성에 대한 실험 연구 (Theoretical Review and Experiment on Applicability of Double Skin Facade Ventilated by Fans)

  • 임지혜;손장열
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.605-613
    • /
    • 2010
  • Double skin facade(DSF) ventilated by fans consists of a normal external and an internal envelope. In this glass layer, the installed fan replaces an air inlet for the control of air flow through the cavity. The purpose of this paper is to investigate physical theory and to analyze the applicability of fans installed in a DSF. The experiment was conducted in 2 rooms. One room has a DSF with installed fans and the other one has a typical window. The room ventilated through a DSF which fans are installed was always kept warmer than the other room, ventilated directly from the outdoors. The average increase of the supplied air temperature through the DSF ventilated by fans was $6.54^{\circ}C$ at 78CMH, $6.2^{\circ}C$ at 95CMH, and $3.7^{\circ}C$ at 120CMH. As a result, the DSF with installed fans was appropriate for installation in rooms. It supplies outdoor fresh air heated through a cavity and ventilates a constant air volume.

Experimental Observations of Boiling and Flow Evolution in a Coiled Tube

  • Ye, P.;Peng, X.F.;Wu, H.L.;Meng, M.;Gong, Y. Eric
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권1호
    • /
    • pp.22-29
    • /
    • 2008
  • A sequence of visually experimental observations was conducted to investigate the flow boiling and two-phase flow in a coiled tube. Different boiling modes and bubble dynamical evolutions were identified for better recognizing the phenomena and understanding the two-phase flow evolution and heat transfer mechanisms. The dissolved gases and remained vapor would serve as foreign nucleation sites, and together with the effect of buoyancy, centrifugal force and liquid flow, these also induce very different flow boiling nucleation, boiling modes, bubble dynamical behavior, and further the boiling heat transfer performance. Bubbly flow, plug flow, slug flow, stratified/wavy flow and annular flow were observed during the boiling process in the coiled tube. Particularly the effects of flow reconstructing and thermal non-equilibrium release in the bends were noted and discussed with the physical understanding. Coupled with the effects of the buoyancy, centrifugal force and inertia or momentum ratio of the two fluids, the flow reconstructing and thermal non-equilibrium release effects have critical importance for flow pattern in the bends and flow evolution in next straight sections.

수직 공간 내에서 고도변화에 따른 기압차로 인한 기류현상 예측에 관한 연구 (Effect of Atmospheric Pressure Difference with Altitude on the Induced Airflow Velocity in a Vertical Closed Conduit)

  • 정광섭;김철호
    • 설비공학논문집
    • /
    • 제21권7호
    • /
    • pp.409-416
    • /
    • 2009
  • On 21st century, global warming is the most serious environmental problem threatening the existence of lives on the earth. One of the serious reasons of this nature phenomena was due to the greenhouse effect by carbon dioxide mainly produced with the combustion process of hydro-carbon fuel. and it is mostly produced. In the high oil prices age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating large percentage whole building loads, and are regarding as the primary target of energy efficiency. The purpose of this research is on the obtaining of the renewable energy source in the skyscrape buildings in the metropolitan area. The air movement is happens due to the atmospheric pressure differences in the air. Due to this simple physical theory, it is easily expected to obtain the useful renewable nature energy through the high -raised vertical air stack installed in a tall building. However, there is one problem that should be resolved which is called air-hole effect in the sky -scrape buildings.