• Title/Summary/Keyword: Physical alignment

Search Result 307, Processing Time 0.024 seconds

Accuracy of three-dimensional printing for manufacturing replica teeth

  • Lee, Keun-Young;Cho, Jin-Woo;Chang, Na-Young;Chae, Jong-Moon;Kang, Kyung-Hwa;Kim, Sang-Cheol;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.45 no.5
    • /
    • pp.217-225
    • /
    • 2015
  • Objective: Three-dimensional (3D) printing is a recent technological development that may play a significant role in orthodontic diagnosis and treatment. It can be used to fabricate skull models or study models, as well as to make replica teeth in autotransplantation or tooth impaction cases. The aim of this study was to evaluate the accuracy of fabrication of replica teeth made by two types of 3D printing technologies. Methods: Fifty extracted molar teeth were selected as samples. They were scanned to generate high-resolution 3D surface model stereolithography files. These files were converted into physical models using two types of 3D printing technologies: Fused deposition modeling (FDM) and PolyJet technology. All replica teeth were scanned and 3D images generated. Computer software compared the replica teeth to the original teeth with linear measurements, volumetric measurements, and mean deviation measurements with best-fit alignment. Paired t-tests were used to statistically analyze the measurements. Results: Most measurements of teeth formed using FDM tended to be slightly smaller, while those of the PolyJet replicas tended to be slightly larger, than those of the extracted teeth. Mean deviation measurements with best-fit alignment of FDM and PolyJet group were 0.047 mm and 0.038 mm, respectively. Although there were statistically significant differences, they were regarded as clinically insignificant. Conclusions: This study confirms that FDM and PolyJet technologies are accurate enough to be usable in orthodontic diagnosis and treatment.

Directional Alignment and Printing of One Dimensional Nanomaterials Using the Combination of Microstructure and Hydrodynamic Force (마이크로 구조 및 동유체력을 이용한 나노와이어 미세 정렬 및 프린팅 기법)

  • Chung, Yongwon;Seo, Jungmok;Lee, Sanggeun;Kwon, Hyukho;Lee, Taeyoon
    • Korean Journal of Materials Research
    • /
    • v.23 no.10
    • /
    • pp.586-591
    • /
    • 2013
  • The printing of nanomaterials onto certain substrates is one of the key technologies behind high-speed interconnection and high-performance electronic devices. For the printing of next-generation electronic devices, a printing process which can be applied to a flexible substrate is needed. A printing process on a flexible substrate requires a lowtemperature, non-vacuum process due to the physical properties of the substrate. In this study, we obtained well-ordered Ag nanowires using modified gravure printing techniques. Ag nanowires are synthesized by a silver nitrate ($AgNO_3$) reduction process in an ethylene glycol solution. Ag nanowires were well aligned by hydrodynamic force on a micro-engraved Si substrate. With the three-dimensional structure of polydimethylsiloxane (PDMS), which has an inverse morphology relative to the micro-engraved Si substrate, the sub-micron alignment of Ag nanowires is possible. This technique can solve the performance problems associated with conventional organic materials. Also, given that this technique enables large-area printing, it has great applicability not only as a next-generation printing technology but also in a range of other fields.

Performance Comparison between Interference Minimization and Signal Maximization in Multi-Cell Random Access Networks (다중 셀 랜덤 액세스 네트워크에서 간섭 최소화 기법과 신호 최대화 기법의 성능 비교)

  • Jo, Han-Seong;Jin, Hu;Jung, Bang Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2014-2021
    • /
    • 2015
  • Opportunistic interference alignment (OIA) has been proposed for multi-cell random access networks (RAN), which minimizes the generating interference to neighboring RANs and yields better performance compared with the conventional techniques. The OIA for RANs considers both physical (PHY) and medium access control (MAC) layers. In this paper, we introduce a protocol of which each user maximizes the transmit signal regardless of the generating interference to neighboring RANs, contrary to the OIA technique. In addition, we compare the performance of the signal-maximization technique with the OIA technique.

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

Application of a Heat Pack and Soft Tissue Mobilization on Hamstring Muscle of Flexibility in Subjects with Cerebral Palsy (온습포와 연부조직 가동술이 뇌성마비의 슬괵근 유연성 증가에 미치는 영향)

  • Ro, Hyo-Lyun;Lee, Dae-Hee;Kang, Dong-Yeon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose:The hamstring muscle has an important role in standing, walking and other functions related to daily living. Most people with Cerebral Palsy(CP) have muscle tightness, especially in the hamstring, which may cause abnormal alignment in the lower extremities. To investigate an effective treatment for hamstring muscle tightness by observing the effects of heat pack or Soft tissue mobilization(STM) on hamstring muscles. Methods:Thirteen-two volunteers with CP aged between 9 and 13 years($M\pmSD$: $11\pm1.46$), were recruited and divided into four groups of four: (1) the STM for people with Spastic CP group, (2) the heat pack(HP) for people with Spastic CP group, (3) the STM for people with Mixd CP group, and (4) the heat pack for people with Mixed CP group. All received treatment three times per week for six weeks. A inclinometer was used to measure for hip flexion & knee extension joint range motion(ROM). Results:The ROM of hip flexion & knee extension were improved at the STM and HP for people with Spastic CP groups. The ROM and hip flexion were improved at the STM and HP for people with Mixed CP groups. The amount of increase ROM are differenced by the types of CP. Conculusion:STM and heat pack, both are effective for people with CP especially for Spastic CP.

  • PDF

Effect of Medial Wedge on Muscle Activity of Lower Limb in Healthy Adults During One Leg Standing (한 다리 서기 시 내측 쐐기(wedge)의 적용이 하지 근활성도에 미치는 영향)

  • Hong, Ji-A;Kim, Min-Hee;Jung, Doh-Heon;Lim, One-Bin;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.18 no.2
    • /
    • pp.60-66
    • /
    • 2011
  • Foot posture is important in the development of the musculoskeletal structure in the lower limbs because it can change the mechanical alignment. Although foot orthotics are widely used for the correction of malalignments in the lower extremities, the biomechanical effects of wedges have not yet been cleared. The aim of this study was to investigate whether medial wedges affect the electromyographic (EMG) activity of the knee and hip joints in healthy adults that are performing one leg standing. Seventeen healthy volunteers performed the one leg standing under two foot conditions: A level surface, and a $15^{\circ}$ medial wedge. The subjects' EMG data for the gluteus maximus (Gmax), gluteus medius (Gmed), tensor fasciae latae (TFL), biceps femoris (BF), vastus lateralis (VL), and vastus medialis oblique (VMO) were recorded, along with the surface EMG, and all were analyzed. The EMG activity of the Gmed and TFL had significantly decreased under the medial wedge condition during one leg standing. Further study is needed in order to investigate whether medial wedges influence the EMG activity and kinematic data of the knee and hip joints as well as the ankle joints in adults with flexible flatfoot, while they are performing one leg standing.

Effects of Shoe Heel Height on Walking Velocity and Electromyographic Activities of Lower Extremity Muscles During Short- and Long-Distance Walking in Young Females (젊은 여성에서 단거리 및 장거리 보행 시 신발 뒤굽 높이가 보행 속도와 다리 근육의 근활성도에 미치는 영향)

  • Oh, Duck-won
    • Physical Therapy Korea
    • /
    • v.26 no.2
    • /
    • pp.16-23
    • /
    • 2019
  • Background: High-heeled shoes can change spinal alignment and feet movement, which leads to muscle fatigue and discomfort in lumbopelvic region, legs, and feet while walking. Objects: This study aimed to identify the effects of different shoe heel heights on the walking velocity and electromyographic (EMG) activities of the lower leg muscles during short- and long-distance walking in young females. Methods: Fifteen young females were recruited in this study. The experiments were performed with the following two different shoe heel heights: 0 cm and 7 cm. All participants underwent an electromyographic procedure to measure the activities and fatigue levels of the tibialis anterior (TA), medial gastrocnemius (MG), rectus femoris (RF), and hamstring muscles with each heel height during both short- and long-distance walking. The walking velocities were measured using the short-distance (10-m walk) and long-distance (6-min walk) walking tests. Results: Significant interaction effects were found between heel height and walking distance conditions for the EMG activities and fatigue levels of TA and MG muscles, and walking velocity (p<.05). The walking velocity and activities of the TA, MG, and RF muscles appeared to be significantly different between the 0 cm and 7 cm heel heights during both short- and long-distance walking (p<.05). Significant difference in the fatigue level of the MG muscle were found between the 0 cm and 7 cm heel heights during long-distance walking. In addition, walking velocity and the fatigue level of the MG muscle at the 7 cm heel height revealed significant differences in the comparison of short- and long-distance walking (p<.05). Conclusion: These findings indicate that higher shoe heel height leads to a decrease in the walking velocity and an increase in the activity and fatigue level of the lower leg muscles, particularly during long-distance walking.

A Need of Management of Horizontal Alignment Design at Rural Roads (지방부 도로에서 평면선형 설계관리의 필요성)

  • Kim, Yong-Seok;Cho, Won-Bum
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.25-31
    • /
    • 2010
  • Road design guideline provides the directions on how to design a road alignment based on design speed, and this guideline has a design expectation in that design speed is supposed to be equal to the operating speed of drivers. Horizontal curve design is also based on design speed, and minimum radius is derived based on the drivers comfort while negotiating the curve. However, side friction reflecting drivers comfort is lower than a physical friction measured on wet road surface, therefore, it is reasonable to regard the criterion on minimum radius has a safety margin. Futhermore, the practical preference of choosing the larger radius than minimum leads to a noticeable gap between design speed and operating speed, so links to the violation of design expectation implicated in the guideline. In order to review this assumption, friction and operating speed at rural roads was measured and observed. As the results, a safety margin brought out by the gap between comfort-based friction and measured friction is qualitatively derived. Also, the gap between design speed and operating speed presumably caused by the safety margin and practical preference is analysed. By this, it is suggested that current design guideline should provides not only the minimum radius but also the management of road alignment design to minimize the gap between the design speed and operating speed.

A novel power trace aligning method for power analysis attacks in mobile devices (모바일 기기에서의 전력 분석 공격을 위한 새로운 전력 신호 정렬 방법)

  • Lee, Yu-Ri;Kim, Wan-Jin;Lee, Young-Jun;Kim, Hyoung-Nam
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.1
    • /
    • pp.153-166
    • /
    • 2011
  • Recent trends in mobile device market whose services are rapidly expanding to provide wireless internet access are drawing people's attention to mobile security. Especially, since threats to information leakage are reaching to the critical level due to the frequent interchange of important data such as personal and financial information through wireless internet, various encryption algorithms has been developed to protect them. The encryption algorithms confront the serious threats by the appearance of side channel attack (SCA) which uses the physical leakage information such as timing, and power consumption, though the their robustness to threats is theoretically verified. Against the threats of SCA, researches including the performance and development direction of SCA should precede. Among tile SCA methods, the power analysis (PA) attack overcome this misalignment problem. The conventional methods require large computational power and they do not effectively deal with the delay changes in a power trace. To overcome the limitation of the conventional methods, we proposed a novel alignment method using peak matching. By computer simulations, we show the advantages of the proposed method compared to the conventional alignment methods.

The Effects of Pulsed Electromagnetic Energy and Microcurrent on Wound Healing in Rabbits. (맥동전자장에너지의 미세전류가 가토의 상처치유에 미치는 영향)

  • Kwon Won-An;Park Rae-Joon;Park Youn-Ki;Hwang Tae-Yeun
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.3
    • /
    • pp.319-329
    • /
    • 2000
  • The purpose of this study w8s to evaluate the effects of pulsed electromagnetic energy(Diapulse) and microcurrent on the wound healing in rabbits. 15 domestic rabbits were randomly assigned to the PRME(n=5). MC(n=5) and CON(n=91 group. Each rabbits were anesthetized with lidocaine HCL $2\%$. Skin wounds were created laterally on the back of IS domestic rabbits(33cm). From 24 hours after being injured, the rabbits of the PEME group were irradiated with an intensity of 3 at a 300 pulses per second, which were applied for 15 minutes every day during the 12 days. The MC group were stimulated with an intensity of $50{\mu}A$ at frequency of40 pulses per second, which were applied for 15 minutes every day during the 12 days. The CON group were not stimulated. The rabbits were sacrificed and the incised wound pans were processed appropriately for the light microscopic examination on the 3rd day, 6th day and 12th day before the beginning of wound treatment. The areas of wound were measured with metric graph paper. The results were as tallows. 1 The PRME and MC group compared with control group showed that wound closure rate increased on 6th, 12th day. 2. It was found that the CON group did not show a complete maturation and had a chronic inflammatory response. Judging from the irregularity of intercellular space and the loose alignment of connective tissue. these findings showed that wound healing was delayed. 3. It showed that inflammatory cells. fibroblasts and epithelial cells activity rapidly processed in the PEME group compared with the CON group. It was found that the PEMI; group showed a advanced remodeling of epithelial layer and a positive repair of connective tissue. 4. It showed that fibroblasts, epithelial cells and inflammatory cells activity rapidly processed in the MC group compared with the CON group. It was found that the MC group showed a improved remodeling of epithelial layer and a dense connective tissue.

  • PDF