DOI QR코드

DOI QR Code

Accuracy of three-dimensional printing for manufacturing replica teeth

  • Lee, Keun-Young (Department of Orthodontics, Wonkwang University Daejeon Dental Hospital) ;
  • Cho, Jin-Woo (Department of Orthodontics, Wonkwang University Daejeon Dental Hospital) ;
  • Chang, Na-Young (Department of Orthodontics, Wonkwang University Daejeon Dental Hospital) ;
  • Chae, Jong-Moon (Department of Orthodontics, Wonkwang University Daejeon Dental Hospital) ;
  • Kang, Kyung-Hwa (Department of Orthodontics, Wonkwang University Dental Hospital) ;
  • Kim, Sang-Cheol (Department of Orthodontics, Wonkwang University Dental Hospital) ;
  • Cho, Jin-Hyoung (Department of Orthodontics, Wonkwang University Sanbon Dental Hospital)
  • Received : 2014.11.11
  • Accepted : 2015.03.26
  • Published : 2015.09.25

Abstract

Objective: Three-dimensional (3D) printing is a recent technological development that may play a significant role in orthodontic diagnosis and treatment. It can be used to fabricate skull models or study models, as well as to make replica teeth in autotransplantation or tooth impaction cases. The aim of this study was to evaluate the accuracy of fabrication of replica teeth made by two types of 3D printing technologies. Methods: Fifty extracted molar teeth were selected as samples. They were scanned to generate high-resolution 3D surface model stereolithography files. These files were converted into physical models using two types of 3D printing technologies: Fused deposition modeling (FDM) and PolyJet technology. All replica teeth were scanned and 3D images generated. Computer software compared the replica teeth to the original teeth with linear measurements, volumetric measurements, and mean deviation measurements with best-fit alignment. Paired t-tests were used to statistically analyze the measurements. Results: Most measurements of teeth formed using FDM tended to be slightly smaller, while those of the PolyJet replicas tended to be slightly larger, than those of the extracted teeth. Mean deviation measurements with best-fit alignment of FDM and PolyJet group were 0.047 mm and 0.038 mm, respectively. Although there were statistically significant differences, they were regarded as clinically insignificant. Conclusions: This study confirms that FDM and PolyJet technologies are accurate enough to be usable in orthodontic diagnosis and treatment.

Keywords

References

  1. Park YS, Jung MH, Shon WJ. Autotransplantion of a displaced mandibular second premolar to its normal position. Am J Orthod Dentofacial Orthop 2013;143:274-80. https://doi.org/10.1016/j.ajodo.2011.11.025
  2. Shahbazian M, Wyatt J, Willems G, Jacobs R. Clinical application of a stereolithographic tooth replica and surgical guide in tooth autotransplantation. Virtual Phys Prototyp 2012;7:211-8. https://doi.org/10.1080/17452759.2012.711681
  3. Honda M, Uehara H, Uehara T, Honda K, Kawashima S, Honda K, et al. Use of a replica graft tooth for evaluation before autotransplantation of a tooth. A CAD/CAM model produced using dental-cone-beam computed tomography. Int J Oral Maxillofac Surg 2010;39:1016-9. https://doi.org/10.1016/j.ijom.2010.06.002
  4. Lee SJ, Jung IY, Lee CY, Choi SY, Kum KY. Clinical application of computer-aided rapid prototyping for tooth transplantation. Dent Traumatol 2001;17:114-9. https://doi.org/10.1034/j.1600-9657.2001.017003114.x
  5. Faber J, Berto PM, Quaresma M. Rapid prototyping as a tool for diagnosis and treatment planning for maxillary canine impaction. Am J Orthod Dentofacial Orthop 2006;129:583-9. https://doi.org/10.1016/j.ajodo.2005.12.015
  6. Stampfl J, Liska R. New materials for rapid prototyping applications. Macromol Chem Phys 2005;206: 1253-6. https://doi.org/10.1002/macp.200500199
  7. Liu Q, Leu MC, Schmitt SM. Rapid prototyping in dentistry: technology and application. Int J Adv Manuf Technol 2006;29:317-35. https://doi.org/10.1007/s00170-005-2523-2
  8. Azari A, Nikzad S. The evolution of rapid prototyping in dentistry: a review. Rapid Prototyp J 2009; 15:216-25. https://doi.org/10.1108/13552540910961946
  9. Kim JH, Kim KB, Kim WC, Kim JH, Kim HY. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique. Korean J Orthod 2014;44:69-76. https://doi.org/10.4041/kjod.2014.44.2.69
  10. Keating AP, Knox J, Bibb R, Zhurov AI. A comparison of plaster, digital and reconstructed study model accuracy. J Orthod 2008;35:191-201. https://doi.org/10.1179/146531207225022626
  11. Cuperus AM, Harms MC, Rangel FA, Bronkhorst EM, Schols JG, Breuning KH. Dental models made with an intraoral scanner: a validation study. Am J Orthod Dentofacial Orthop 2012;142:308-13. https://doi.org/10.1016/j.ajodo.2012.03.031
  12. Kasparova M, Grafova L, Dvorak P, Dostalova T, Prochazka A, Eliasova H, et al. Possibility of reconstruction of dental plaster cast from 3D digital study models. Biomed Eng Online 2013;12:49. https://doi.org/10.1186/1475-925X-12-49
  13. Hazeveld A, Huddleston Slater JJ, Ren Y. Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am J Orthod Dentofacial Orthop 2014; 145:108-15. https://doi.org/10.1016/j.ajodo.2013.05.011
  14. Stanek M, Manas D, Manas M, Navratil J, Kyas K, Senkerik V, et al. Comparison of different rapid prototyping methods. Intern J Math Comput Simul 2012;6:550-7
  15. Park HM. Comparing group means: T-tests and Oneway ANOVA, Using Stata, SAS, R, and SPSS, Working Paper. Bloomington, IN: The University Information Technology Services Center for Statistical and Mathematical Computing, Indiana University; 2009.
  16. Lilliefors HW. On the Kolmogorov-Smirnov test for normality with mean and variance unknown. J Am Stat Assoc 1967;62:399-402. https://doi.org/10.1080/01621459.1967.10482916
  17. Muller R, Buttner P. A critical discussion of intraclass correlation coefficients. Stat Med 1994;13:2465-76. https://doi.org/10.1002/sim.4780132310
  18. Bell A, Ayoub AF, Siebert P. Assessment of the accuracy of a three-dimensional imaging system for archiving dental study models. J Orthod 2003; 30:219-23. https://doi.org/10.1093/ortho/30.3.219
  19. Barker TM, Earwaker WJ, Lisle DA. Accuracy of stereolithographic models of human anatomy. Australas Radiol 1994;38:106-11. https://doi.org/10.1111/j.1440-1673.1994.tb00146.x
  20. Murugesan K, Anandapandian PA, Sharma SK, Vasantha Kumar M. Comparative evaluation of dimension and surface detail accuracy of models produced by three different rapid prototype techniques. J Indian Prosthodont Soc 2012;12:16-20. https://doi.org/10.1007/s13191-011-0103-8
  21. Cheah CM, Chua CK, Tan KH, Teo CK. Integration of laser surface digitizing with CAD/CAM techniques for developing facial prostheses. Part 1: Design and fabrication of prosthesis replicas. Int J Prosthodont 2003;16:435-41.
  22. Bibb R, Freeman P, Brown R, Sugar A, Evans P, Bocca A. An investigation of three-dimensional scanning of human body surfaces and its use in the design and manufacture of prostheses. Proc Inst Mech Eng H 2000;214:589-94.
  23. Halazonetis DJ. Acquisition of 3-dimensional shapes from images. Am J Orthod Dentofacial Orthop 2001; 119:556-60. https://doi.org/10.1067/mod.2001.115459

Cited by

  1. Design and Fabrication of a Disposable Dental Handpiece for Clinical Use of a New Laser-Based Therapy-Monitoring System vol.10, pp.1, 2015, https://doi.org/10.1115/1.4031800
  2. 3D-Printed Visceral Aneurysm Models Based on CT Data for Simulations of Endovascular Embolization: Evaluation of Size and Shape Accuracy vol.209, pp.2, 2015, https://doi.org/10.2214/ajr.16.17694
  3. Clear Aligner Treatment with “In-Office” Virtual Model Set-Up and 3D Printing. vol.3, pp.2, 2015, https://doi.org/10.15436/2379-1705.17.1418
  4. Letter to the editor vol.79, pp.2, 2015, https://doi.org/10.1007/s00056-018-0126-4
  5. Accuracy of three-dimensional dental resin models created by fused deposition modeling, stereolithography, and Polyjet prototype technologies: A comparative study vol.88, pp.3, 2015, https://doi.org/10.2319/071117-460.1
  6. Computer-aided autotransplantation of teeth with 3D printed surgical guides and arch bar: a preliminary experience vol.6, pp.None, 2015, https://doi.org/10.7717/peerj.5939
  7. Methodology for Stress Measurement by Transparent Dental Aligners using Strain Gauge vol.9, pp.1, 2015, https://doi.org/10.5005/jp-journals-10015-1499
  8. Application of 3D visualization and 3D printing technology on ERCP for patients with hilar cholangiocarcinoma vol.15, pp.4, 2015, https://doi.org/10.3892/etm.2018.5831
  9. Computed Tomography versus Optical Scanning: A Comparison of Different Methods of 3D Data Acquisition for Tooth Replication vol.2019, pp.None, 2015, https://doi.org/10.1155/2019/4985121
  10. Comparison of Selected Thermoplastic Materials in the Fused Deposition Modeling Process and their Influence on the Dimensional Accuracy of an Orthodontic Upper Teeth Model vol.952, pp.None, 2019, https://doi.org/10.4028/www.scientific.net/msf.952.143
  11. Digital microscopic evaluation of vertical marginal discrepancies of CAD/CAM fabricated zirconia cores vol.64, pp.2, 2015, https://doi.org/10.1515/bmt-2017-0234
  12. Reliability and intra-examiner agreement of orthodontic model analysis with a digital caliper on plaster and printed dental models vol.23, pp.8, 2019, https://doi.org/10.1007/s00784-018-2772-8
  13. Autotransplantation of mature impacted tooth to a fresh molar socket using a 3D replica and guided bone regeneration: two years retrospective case series vol.19, pp.1, 2019, https://doi.org/10.1186/s12903-019-0945-8
  14. 치과용 3D 프린터로 제작된 임시 수복용 레진의 정확도 평가 vol.19, pp.6, 2019, https://doi.org/10.13065/jksdh.20190094
  15. 3D Visualization Reconstruction Assists Diagnosis and Treatment of Patients with Complex Intestinal Obstruction: A Case Report vol.10, pp.6, 2015, https://doi.org/10.12677/acm.2020.106138
  16. Effects of Steam Sterilization on 3D Printed Biocompatible Resin Materials for Surgical Guides—An Accuracy Assessment Study vol.9, pp.5, 2015, https://doi.org/10.3390/jcm9051506
  17. Three-Dimensional Slurry Printing Technology in Ceramic and Metal Application vol.311, pp.None, 2015, https://doi.org/10.4028/www.scientific.net/ssp.311.21
  18. The Effects of Combined Infill Patterns on Mechanical Properties in FDM Process vol.12, pp.12, 2020, https://doi.org/10.3390/polym12122792
  19. An Analysis of the Casting Polymer Mold Wear Manufactured Using PolyJet Method Based on the Measurement of the Surface Topography vol.12, pp.12, 2015, https://doi.org/10.3390/polym12123029
  20. Estimating the Accuracy of Mandible Anatomical Models Manufactured Using Material Extrusion Methods vol.13, pp.14, 2015, https://doi.org/10.3390/polym13142271
  21. Manufacturing a First Upper Molar Dental Forceps Using Continuous Fiber Reinforcement (CFR) Additive Manufacturing Technology with Carbon-Reinforced Polyamide vol.13, pp.16, 2015, https://doi.org/10.3390/polym13162647
  22. The State of the Art of Material Jetting-A Critical Review vol.13, pp.16, 2015, https://doi.org/10.3390/polym13162829
  23. Does Augmented Visual Feedback from Novel, Multicolored, Three‐Dimensional‐Printed Teeth Affect Dental Students' Acquisition of Manual Skills? vol.14, pp.5, 2015, https://doi.org/10.1002/ase.2014
  24. Dimensional accuracy and surface characteristics of 3D-printed dental casts vol.126, pp.3, 2015, https://doi.org/10.1016/j.prosdent.2020.07.008
  25. Assessment of the accuracy of 3D printed teeth by various 3D printers in forensic odontology vol.328, pp.None, 2021, https://doi.org/10.1016/j.forsciint.2021.111044
  26. Precision of computed tomography and cartilage-reproducing image reconstruction method in generating digital model for potential use in 3D printing of patient-specific radial head prosthesis: a human vol.7, pp.1, 2015, https://doi.org/10.1186/s41205-021-00093-w
  27. Procedure Increasing the Accuracy of Modelling and the Manufacturing of Surgical Templates with the Use of 3D Printing Techniques, Applied in Planning the Procedures of Reconstruction of the Mandible vol.10, pp.23, 2015, https://doi.org/10.3390/jcm10235525
  28. Evaluation of the accuracy of cone beam computed tomography (CBCT) generated tooth replicas with application in autotransplantation vol.117, pp.None, 2015, https://doi.org/10.1016/j.jdent.2021.103908