• Title/Summary/Keyword: Physical Measurement

Search Result 2,914, Processing Time 0.025 seconds

Effects of Plank Exercises with Resistance of One-Sided Hip Adduction on the Abdominal Muscle Thickness

  • Park, JaeCheol;Jeong, JinGyu
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.2
    • /
    • pp.82-87
    • /
    • 2019
  • Purpose: The purpose of this study was to examine the effects of plank exercises with resistance of one-sided hip adduction on abdominal muscle thickness. Methods: Thirty subjects were divided into a group that underwent plank exercises with one-sided hip adduction resistance (n=15) and a group that underwent plank exercises only (n=15). Their changes in abdominal muscle thickness before the experiment (n=15) and three and six weeks after the experiment were analyzed using a two-way repeated analysis of variance at a statistical significance level of ${\alpha}=0.05$. When there was any interaction between the time of measurement and each group, post hoc t-tests were conducted at a statistical significance level of ${\alpha}=0.01$. Results: The results of the experiment showed statistically significant differences in the thickness of the rectus abdominis, internal oblique muscle, and transversus abdominis, depending on the time of measurement and the interaction between the time of measurement and each group (p<0.05). Statistically significant differences were observed in the thickness of the external oblique, depending on the time of measurement, the interaction between the time of measurement and each group, and variances between the groups (p<0.05). Conclusion: The results of this study indicated that plank exercises with resistance of one-sided adduction are effective for increasing abdominal muscle thickness. The study's overall findings will likely be used as basic data for lumbar stabilization exercises and rehabilitation treatment.

Comparison of Distance of Subacromial Space Using Ultrasonographic Measurement on Arm Positions of Shoulder Injured Patients (견부손상환자의 팔의 자세에 따른 초음파 영상을 이용한 견봉하공간 거리의 비교)

  • Jee, Eun-Mi;Kim, Suhn-Yeop;Park, Ji-Whan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.397-406
    • /
    • 2011
  • Purpose : Recently ultrasound images has been used to measure the subacromial space with a linear measurement of the acromiohumeral distance. The purpose of this study was to comparison of distance of subacromial space using ultrasonographic measurement on arm positions of shoulder injured patients. Methods : The subjects were 30 shoulder injured patients (19 males and 11 females). Ultrasonography was performed to measure subacromial space during each shoulder resting position, $45^{\circ}$ abduction, internal rotation with $45^{\circ}$ abduction and external rotation with $45^{\circ}$ abduction. Results : Subacromial space was a significantly difference between injured arm and normal arm at shoulder resting position. At $45^{\circ}$ abduction, subacromial space was narrowing significantly between injured arm and normal arm. At external rotation with $45^{\circ}$ abduction, subacromial space were wider in normal arm than in injured arm but it was not significantly. Intra-observer reliability for ultrasonography measurement of subacromial distance was excellent (.96~.99). Conclusion : These results identified that positions of injured shoulder was related to subacromion space.

Technical Trends of Domestic and Overseas on Electro-physical Properties Measurement (전기물성 측정의 국내외 기술 동향)

  • Park, Sam-Gyu;Cho, Seong-Jun;Lee, Tae-Jong;Lee, Seong-Kon;Lee, Sang-Kyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.285-290
    • /
    • 2007
  • Electrical and electromagnetic methods were widely applied to survey of civil engineering, environment site assessments and maintenance of underground structures in Korea. Electro-physical properties measurements of soil and rock are necessary in order to quantitatively estimate the ground from these survey results. A few geotechnical researcher groups have been simplified measurement system of the electro-physical properties, which was intermittently operating by the necessity. Recent strong concern about $CO_2$ underground storage and development of gas hydrate projects have urged many advanced countries. The electro-physical properties estimation of the deep object stratum is very importance for basic information of these research. So, advanced countries have a high-end measurement system with high temperature(200 degrees) and pressure(300 MPa), also they have been a lot of experience and know-how on the electro-physical properties measurement.

  • PDF

Intra and Inter-Rater Measurement Reliability of Tibialis Anterior Muscle (TA) Thickness using the Ultrasonography Spring Gauge Technique

  • Hwang, Byeong-Hun;Jang, Tae-Jin;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.4
    • /
    • pp.187-192
    • /
    • 2021
  • Purpose: The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness measurement of the TA using ultrasonography (US) conducted at different inward pressures of approximately 0.5 kg, 1.0 kg, and no pressure control. Methods: Twenty healthy subjects were recruited for this study. Two different examiners measured the thicknesses of the dominant TA of each subject randomly to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval, standard error of measurement, minimal detectable change, and coefficient of variance. Results: All intra-rater reliability ICC values showed high reliability above 0.9. Inter-rater reliability ICC values showed high reliability above 0.9 with 0.5 and 1.0 kg of inward pressure. In contrast, Inter-rater reliability ICC values showed poor reliability (0.23) with no pressure control of inward pressure. Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results when the muscle thickness of the TA is measured by different examiners in a clinical setting.

A Study on Development of Integration Performance Measurement Model for Each Stage of Information Systems Integration and Measurement Indicators of Physical Integration Stage (정보시스템 통합단계별 성과측정 모형 및 물리적 통합단계의 측정지표 개발에 관한 연구)

  • Jung, Hae-Yong;Ra, Jong-Hei
    • Journal of Information Technology Services
    • /
    • v.7 no.4
    • /
    • pp.247-268
    • /
    • 2008
  • This study aims to develop an integration performance measurement model for each stage of information systems integration. In order to achieve the purpose of the research, first of all, the concepts of IS integration or consolidation are analyzed through theoretical and practical reviews. Also, a number of important studies of domestic and overseas cases about the stage models of IS integration or consolidation are critically reviewed. Second, we proposed three step stage model of is integration, Physical Integration stage, Application Integration stage, Service Integration stage, and Also proposed the performance measurement model for each stage of information systems integration. Third, especially in case of performance indicators and performance measurement methodology for physical integration stage are illustratively proposed, based upon the case of NCIA (National Computing Integration Agency) in Korea. This study provides the theoretical basis for reasonably deriving the stage model and performance measurement model for each stage of Information Systems Integration, and they are validating through investigating domestic and foreign practices. The results of this study are very likely to contribute to presenting the practical guideline for desirably implementing is integration or IS consolidation.

The effects of GCM ankle joint therapy on Shoulder and Neck (전신조정술 발목관절치료가 어깨와 목에 미치는 영향)

  • Hyoung In-Hyouk;Ahn Mock;Bae Sung-Soo;Mun Sang-Eun;Chae Jung-Byung
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.479-487
    • /
    • 2003
  • Tje purpose of this study is to understand body as a whole concept through examining effects of distant shoulder and neck with GCM ankle joint therapy. The twenty three subject with ankle joint therapy and comparison groups without ankle joint therapy were authorized the score of before and after therapy by correspondence T-test using pump lines and tapes as instruments. The results are as follows. 1. The test group had change of shoulder in measurement 1, 2, 3 and were regarded statistically 1st measurement on left, 2nd on right.(p<.05) 2. The test group had change of neck in measurement 1, 2, 3 and were regarded statistically 2nd on left on right.(p<.05) 3. In the comparison group the comparison of shoulder height was not regarded statistically all at 1, 2 comparison on left and regarded statistically all at 1, 2 comparison on right.(p<.05) 4. In the comparison group the comparison of neck height was not regarded statistically both left and right at 1, 2 comparison.(p<.05)

  • PDF

W-Band Permittivity Measurements Using a Free-Space Material Measurement Technique (자유공간 물질상수 측정법을 이용한 W-Band 유전율 측정)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Cho, Chihyun;Kim, Dae-Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.253-258
    • /
    • 2013
  • In this paper, a free-space material measurement technique is discussed in W-band(75~110 GHz). For the accurate measurement of S-parameters of an MUT(Material Under Test) in free space, a W-band quasi-optical free-space material measurement system, less affected by the measurement environments, is discussed, and GRL(Gated Reflect Line) method for calibrating the measurement system is described. Proposed technique is verified for 'Air' and measurement results for arystal plates of thickness 1.1 mm, 2 mm, 2.75 mm and 5 mm are also shown.

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

Computer Adaptive Testing Method for Measuring Disability in Patients With Back Pain

  • Choi, Bongsam
    • Physical Therapy Korea
    • /
    • v.19 no.3
    • /
    • pp.124-131
    • /
    • 2012
  • Most conventional instruments measuring disability rely on total score by simply adding individual item responses, which is dependent on the items chosen to represent the underlying construct (test-dependent) and a test statistic, such as coefficient alpha for the estimate of reliability, varying from sample to sample (sample-dependent). By contrast, item response theory (IRT) method focuses on the psychometric properties of the test items instead of the instrument as a whole. By estimating probability that a respondent will select a particular rating for an item, item difficulty and person ability (or disability) can be placed on same linear continuum. These estimates are invariant regardless of the item used (test-free measurement) and the ability of sample applied (sample-free measurement). These advantages of IRT allow the creation of invariantly calibrated large item banks that precisely discriminate the disability levels of individuals. Computer adaptive testing (CAT) method often requiring a testing algorithm promise a means for administering items in a way that is both efficient and precise. This method permits selectively administering items that are closely matched to the ability level of individuals (measurement precision) and measuring the ability without the loss of precision provided by the full item bank (measurement efficiency). These measurement properties can reasonably be achieved using IRT and CAT method. This article aims to investigate comprehensive overview of the existing disability instrument for back pain and to inform physical therapists of an alternative innovative way overcoming the shortcomings of conventional disability instruments. An understanding of IRT and CAT method will equip physical therapist with skills in interpreting the measurement properties of disability instruments developed using the methods.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.