• 제목/요약/키워드: Photovoltaic-wind power system

검색결과 176건 처리시간 0.024초

동력저장장치를 이용한 풍력$\cdot$태양광 복합발전시스템의 특성분석 (Analysis on the Operation Characteristic of the Combined Electric Power Generation System by Photovoltaic and Wind Energy with Power Storage Apparatu)

  • 임중열;이정일;정학수;차인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.58-62
    • /
    • 2001
  • Photovoltaic and wind power generation have an advantage of unlimited and unpolluted amount of energy resource. In conventional wind generation systems, since the blade rotates at low speed when the velocity of wind decreases their operations are possible only under limited conditions. Therefore they are in trouble of self-generation without the help of auxiliary generation devices outside. The system driven by the wind force in this paper consists of a generator, an invertor, batteries and sets for power storage with a spring. In this paper, the operation characteristics of system were analyzed through experiments for a trial product.

  • PDF

해양플랜트 설비의 비상전원공급을 위한 태양광 발전시스템 연구 (Study of a Photovoltaic System as an Emergency Power Supply for Offshore Plant Facilities)

  • 최군환;이병호;정노택;신규보
    • 한국해양공학회지
    • /
    • 제32권4호
    • /
    • pp.279-286
    • /
    • 2018
  • The use of eco-friendly energy in the offshore plant system is expanding because conventional generators are operated by fossil fuel or natural gas. Eco-friendly energy, which replaces existing power generation methods, should be capable of generating the power for lighting protection equipment, airborne fault indication, parameter measurement, and others. Most of the eco-friendly energy used in offshore plant facilities is solar and wind power. In the case of using photovoltaic power, because the structure must be constructed based as flat solar panels, it can be damaged easily by the wind. Therefore, there is a need for a new generation system composed of a spherical structure that does not require a separate structure and is less influenced by the wind. Considering these characteristics, in this study we designed, fabricated, and tested a unit that could provide the most efficient spherical photovoltaic power generation considering wind direction and wind pressure. Our test results indicated that the proposed system reduced costs because it did not require any separate structure, used eco-friendly energy, reduced carbon dioxide emissions, and expanded the proportion of eco-friendly energy use by offshore plant facilities.

HOMER를 이용한 가정용 태양광-연료전지 하이브리드시스템의 운전 최적화 (Optimization of Residential Photovoltaic-Fuel Cell Hybrid System Using HOMER(R))

  • 박세준;이영;최용성;이경섭
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.129-133
    • /
    • 2010
  • A hybrid system which is combined several complementary new and renewable power sources, such as photovoltaic, fuel-cell, and wind generator, etc., has been presented in various approaches. For instance, a photovoltaic cannot always generate stable output power with ever-changing weather condition, so it might be co-generated with a wind generator, diesel generator, and some other sources. In this paper, a residential PV-FC hybrid system is suggested as a distribution power source, and its operation is optimized by HOMER$^{(R)}$. As a result, it is the most economic that 5[kW] PV, 1[kW] FC, 4 batteries, 2[kW] electrolyzer, 0.5[kg] $H_2$ tank, 3[kW] converter are applied to the hybrid system.

계통연계 풍력 및 태양광발전시스템 고조파 영향 검토 (Harmonic Impact Studies of Grid-Connected Wind Power and PV Generation Systems)

  • 이상민;정형모;유권종;이강완
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2185-2191
    • /
    • 2009
  • Wind power and photovoltaic(PV) generation systems are the fastest growing sources of renewable energy. The nonlinear devices, such as power electronic converter or inverter, of wind power and PV generation systems are the source of harmonics in power systems. The harmonic-related problems can have significant detrimental effects in the power system, such as capacitor heating, data communication interference, rotating equipment heating, transformer heating, relay misoperation and switchgear failure. There is a greater need for harmonic analysis that can properly maintain the power quality. By measuring harmonics of existing wind power and PV generation systems as harmonics modeling, the studies were made to see the harmonic impact of grid-connected wind power and PV generation systems.

가정용 태양광/풍력 Hybrid 발전시스템의 모니터링에 관한 연구 (A Study on Monitoring for based-Photovoltaic/Wind power Hybrid Generation System)

  • 정병영;차인수;임중열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.365-368
    • /
    • 2006
  • The objective of this research is to investigate usage of 3KW photovoltaic-wind power hybrid generation system composed of 500W solar power generator and 400W wind power generator in a parallel circuit. In addition, solar radiation meter and wind monitor have been installed into each generation system to obtain the practical operating data that monitored in monthly, daily and hourly. These data that are independent to weather change and location would provide adequate generation output on average and cope with emergency situation in generation system In conclusion, based on this study, it could be considered for 3KW combined generation system to be gradually propagated to houses and small-size public facilities.

  • PDF

수상태양광 발전 시스템의 환경에 따른 모듈의 전기적 특성 (The Electrical Characteristics of The Modules According to The Environment of The Floating Photovoltaic System)

  • 황수현;이동영;권오극;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.283-289
    • /
    • 2018
  • In our study, we collected data from a 100 kW floating photovoltaic (PV) system installed in Gyeongnam Hapcheon Dam and observed correlations between the power generation of the floating PV system and the irradiance, water temperature, humidity, ambient temperature, wind speed, and module temperature. Firstly, there was little correlation between the water temperature and power generation. Secondly, the ambient temperature, wind speed, and humidity all showed greater correlations with power generation. Finally, the power generation was very highly correlated with the irradiance and module temperature. In conclusion, the power generation of the floating PV system is related individually to environmental factors.

바람 증폭 장치를 가진 태양전지 오염방지시스템의 TRIZ(6SC) 응용 설계 (A Study on TRIZ Applied Design for Contamination Preventation System of Solar Battery with Wind Amplifier)

  • 허용정;홍성도;김재민
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.7-11
    • /
    • 2013
  • This paper presents a study on the design for contamination preventation system of solar battery. The system of contamination preventation has an wind amplifier. Wind amplifier is conceptually designed by using TRIZ. The surface of solar battery is covered with dust during accumulate the energy. The dust cause reduce power of photovoltaic module and efficiency drop of photovoltaic system. Reflect and absorb of incident ray are caused by the dust on surface of solar battery. The solution of this problem has been derived using 6SC(6 steps creativity)TRIZ. The wind amplifier which has structure such as funnel shape. The incident wind in the wide hole is amplified by the gate become narrow. The system of contamination preventation with wind amplifier which mounted on the side of the solar battery surface reduces the reflect and absorb and improve the efficiency of photovoltaic system.

탄성에너지를 이용한 전력보상장치의 운전특성에 관한 연구 (A Study on Driving Characteristics of Power Conpensation Device using elasticit)

  • 박세준;강병복;임중열;윤정필;조경재;차인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.235-239
    • /
    • 2002
  • Combined generation system of photovoltaic and wind power is required backup system that such as a storage battery to supply energy, when not enough photovoltaic and wind power source for power supply equally and continually, because the energy source is changeable and stable through change of weather as irradiation, temperature, wind speed, wind speed, wind direction, seasons, etc..

  • PDF

제주지역 풍력발전 및 태양광발전의 전력계통 부하기여 분석 (Analysis of the Load Contribution of Wind Power and Photovoltaic Power to Power System in Jeju)

  • 명호산;김형철;강남호;김영환;김세호
    • 한국태양에너지학회 논문집
    • /
    • 제38권1호
    • /
    • pp.13-24
    • /
    • 2018
  • As part of the "Carbon free Island 2030" policy, the local government of Jeju Island is currently working to reduce carbon through renewable energy supply. However, renewable energy is difficult to predict due to intermittent characteristics. If the share of renewable energy increase, it is difficult to plan of supply of electricity to grid due to that characteristic of renewable. In this paper analyze the fluctuation rate and the capacity credit of wind power and PV to find out how much wind power and PV contribute to supply of electricity of power system in Jeju. As a result mean value of variation rate of wind power and PV is about 3%, 5% and capacity credit is about 10% and 2% respectively.

LabVIEW를 이용한 철도 선로전환기 융설용 태양광-풍력 발전 모니터링 시스템의 적용 방법 (The Application of Monitoring System Methods of Photovoltaic-Wind Power Generation for Railway Switching Point Heating Using LabVIEW)

  • 김대년;김덕현;최정원
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.9-14
    • /
    • 2013
  • The monitoring system is an absolutely required system for improving a performance to consider the situation for the hybrid generation of the photovoltaic (PV) and wind power (WP) energy experimental research complex. This system is to monitor with the railroad switching point heating system using LabVIEW to the hybrid generation of the PV and WP. The monitoring system of this paper is a program monitoring the hour, day and total of the voltage and current that made from the hybrid generation of PV and WP. In experiment, we acquired the power data according to time at the day of PV and WP. We have confirmed the possibility of the real time monitoring system using LabVIEW with the railroad switching point heating system as the hybrid generation of the PV and WP.