Postal Dosimetry Audits for the Domestic Medical Linear Accelerator

  • Kim, Kum Bae;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.20-28
    • /
    • 2020
  • Purpose: The objective of this study is to perform Postal dosimetry audits for medical linear accelerators in radiation therapy institutions using glass dosimeters and Gafchromic film reading systems and postal dosimetry audit procedures, and to evaluate radiation therapy doses and mechanical accuracy in medical institutions. Methods: Photon output measured and analyzed using a standard phantom for measuring photon output dose using a glass dosimeter for medical linear accelerators. Mechanical accuracy was measured and analyzed using software for film measurement. Results: Measurement and analysis of photon beam output dose using a standard phantom glass dosimeter for photon beam output dose measurement was completed. All tolerance doses were within 5%. Mechanical accuracy measurement and analysis using a standard phantom for verifying the mechanical accuracy of linear accelerator (LINAC) using a Gafchromic film were completed, and all results were shown within tolerances (2 mm or less). Conclusions: In this study, Postal dosimetry audits were performed on the output dose and mechanical accuracy of photon beams (207 beams) for 106 LINACs from 48 institutions. As a result of corrective action and re-execution, it was confirmed that all engines met the acceptable standard within 2 mm in the linear accelerator.

흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화 (Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses)

  • 김성훈;허현도;최상현;김혁주;임천일;신동오;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.120-125
    • /
    • 2010
  • 물흡수선량에 기반한 표준 측정법을 사용하여 흡수선량을 측정 시에 여러 요인들이 크건, 작건, 미미하건 간에 선량 측정의 정확성에 영향을 미칠 수 있다. 이온함의 선질 보정 인자(the beam quality correction factor) ${\kappa}_{Q,Q_0}$ 값 또한 그 중 한 요인이 될 수 있다. 본 연구에서는 특정 이온함 유형(PTW30013, PTW, Germany)을 선정하여, 국내에서 사용하고 있는 기관들로부터 9개의 이온함을 수집하였다. 동일한 전위계와 전기선으로 9개 이온함을 국내 이차표준기관으로부터 교정을 받았다. 이렇게 교정받은 이온함들을 사용하여 Siemens ONCOR 장비의 광자 빔 6 MV와 10 MV 그리고 전자 빔 12 MeV에 대해 기준 조건하에서 흡수선량을 측정하였다. 이온함 간 선량 값의 최대 차이는 광자 빔 6 MV의 경우엔 2.4%, 10MV의 경우에 0.8%, 전자 빔 12 MeV의 경우엔 0.8%이었다. 6 MV에서의 큰 차이는 측정 과정에 문제가 없었다면, 동일한 ${\kappa}_{Q,Q_0}$ 값을 모든 이온함에 적용한 게 한 요인이 될 수 있다. 이는 또한 외부 독립검사가 왜 중요한지를 보여 주는 예라 하겠다.

Energy Response in Chemiluminescence Dosimetry with Sugar and Sorbite

  • Jun, J.S.;Guggenberger, R.;Dalheimer, A.
    • Nuclear Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.626-637
    • /
    • 2001
  • A series of study on energy dependence in chemiluminescence dosimetry with sugar and sorbite produced in two different countries was carried out administering a dose of 5 Gy to the samples at six different mean photon energies of 30, 50, 80, 130, 662 and 1250 keV. The results revealed distinct energy dependence of chemiluminescence(CL) output of sugar and sorbite. Although the energy dependence, in general, could be fitted by a polynomial of (os E, with I being radiation energy, up to cubic term, we reached a conclusion that the adoption of a fitting function, $y_{R}$$^{=a}$.(1-e $^{-b.logE}$)$^{c}$ +d, deduced from theoretical energy response curve calculated as the ratio of the mass energy absorption of the samples of interest to the soft tissue is more reasonable and rational. Herecoefficients $y_{R}$ is CL intensity, and a, b, c and d are constants to be determined in the fitting process. Energy dependence of relative sensitivities of one sample to the other, discrepancy in sensitivities of the samples from the two countries, and prominent grain size effect in Sorbitol were also shown.shown.

  • PDF

Dosimetry Application of Irradiated D-fructose using the Electron Paramagnetic Resonance

  • Son, Phil Kook;Choi, Suk-Won;Kim, Sung Soo;Gwag, Jin Seog
    • Journal of Magnetics
    • /
    • 제17권4호
    • /
    • pp.271-274
    • /
    • 2012
  • We examine dosimetry application of irradiated D-fructose materials using electron paramagnetic resonance (EPR). Consequently, we consider that fructose is one of best dosimetry materials. We found that fructose is one of best candidates for dosimetry due to high linearity tilt of EPR signal intensity as a function of dose, irrelevant to photon energy, constant fading value. Also, our results show that fructose materials can be applied as a radiation detector to very weak radiation doses of 0.001 Gray by using EPR at a low temperature (T = 220 K).

다이오드를 이용한 광자선 선량측정에 관한 연구 (A Study on Photon Dosimetry System with Diode Defectors)

  • 이동훈;강전권;장영권;지영훈;홍승홍
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.148-151
    • /
    • 1992
  • There is a definite requirement to continuously monitor the operating characteristics of radiation therapy machines. It is advisable to monitor the symmetry, flatness, and energy stability of x-ray beams. The semiconductor system was developed using commercially available rectifier diode for th assessment of quality assurance In radiation therapy, which is capable of the above measurements. The beam characteristics of 6MV, 10MV and 21MV photon of Microtron electron accelerator were measured using seven-diodes as detectors and the results were compared with that of using a film results dosimetry with a X-Y plotter. The seven-diode detetor is versatile enough to be used for checking beam profile, flatness, symmetry and energy.

  • PDF

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF

A Review of Organ Dose Calculation Methods and Tools for Patients Undergoing Diagnostic Nuclear Medicine Procedures

  • Choonsik Lee
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.1-18
    • /
    • 2024
  • Exponential growth has been observed in nuclear medicine procedures worldwide in the past decades. The considerable increase is attributed to the advance of positron emission tomography and single photon emission computed tomography, as well as the introduction of new radiopharmaceuticals. Although nuclear medicine procedures provide undisputable diagnostic and therapeutic benefits to patients, the substantial increase in radiation exposure to nuclear medicine patients raises concerns about potential adverse health effects and calls for the urgent need to monitor exposure levels. In the current article, model-based internal dosimetry methods were reviewed, focusing on Medical Internal Radiation Dose (MIRD) formalism, biokinetic data, human anatomy models (stylized, voxel, and hybrid computational human phantoms), and energy spectrum data of radionuclides. Key results from many articles on nuclear medicine dosimetry and comparisons of dosimetry quantities based on different types of human anatomy models were summarized. Key characteristics of seven model-based dose calculation tools were tabulated and discussed, including dose quantities, computational human phantoms used for dose calculations, decay data for radionuclides, biokinetic data, and user interface. Lastly, future research needs in nuclear medicine dosimetry were discussed. Model-based internal dosimetry methods were reviewed focusing on MIRD formalism, biokinetic data, human anatomy models, and energy spectrum data of radionuclides. Future research should focus on updating biokinetic data, revising energy transfer quantities for alimentary and gastrointestinal tracts, accounting for body size in nuclear medicine dosimetry, and recalculating dose coefficients based on the latest biokinetic and energy transfer data.

고 에너지 광자선 계측용 2차원 광섬유 방사선 센서의 제작 및 특성분석 (Fabrication and Characterization of Two-dimensional Fiber-optic Radiation Sensor for High Energy Photon Beam Therapy Dosimetry)

  • 장경원;조동현;신상훈;김형식;이정한;이봉수;김신;조효성
    • 한국광학회지
    • /
    • 제18권4호
    • /
    • pp.241-245
    • /
    • 2007
  • 본 연구에서는 유기 섬광체와 플라스틱 광섬유를 이용하여 치료용 광자선의 계측을 위한 2차원 광섬유 방사선 센서를 제작하였다. 제작된 센서를 사용하여 광자선 조사야(Field size)와 에너지에 따른 선형가속기의 빔 분포도를 2차원적으로 측정하였으며 polymethylmethacrylate(PMMA)팬텀 내에서 깊이에 따른 섬광체의 광량을 측정하여 깊이선량 분포(Percent Depth Dose, PDD) 또한 2차원으로 측정하였다. 본 연구를 통하여 개발된 2차원 광섬유 방사선 센서는 고 분해능, 실시간 측정, 쉬운 보정 등 많은 장점을 가지고 있다.

물 흡수선량 표준에 기반한 선량교정 프로그램 개발 (Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.175-183
    • /
    • 2003
  • 최근 선량측정의 정확성을 향상시키기 위하여 기존의 공기커마 교정인수에 기반한 표준측정법에서 물 흡수선량 교정인수에 기반한 표준측정법으로 변환하고 있는 추세이다. 본 연구에서는 미국의학물리학회의 AAPM TG-51과 국제원자력기구의 IAEA TRS-398 표준측정법에 대한 선량교정 프로그램을 개발하였다. 이 프로그램은 윈도우 환경에서 사용이 용이하도록 비쥬얼 C++언어를 사용하여 각각의 표준측정법에서 권고하고 있는 방법 및 절차에 따라 사용자의 편의성을 고려하여 개발하였다. 이 프로그램은 이온함에 대한 정보와 물리적인 자료에 대한 표와 그래프 값들을 수식화하여 데이터베이스화함으로써 수작업으로 인해 발생할 수 있는 실수 및 오차를 줄일 수 있다. 개발된 프로그램의 활용을 통하여 국내 실정에 적합한 물 흡수선량 표준에 기반한 표준측정법 개발에 토대를 마련하는데 있어 기여할 것으로 사료된다.

  • PDF

웹 기반 고 에너지 방사선에 대한 흡수선량 교정 프로그램 개발 (Development of Web-based Dosimetry Calibration Program for High Energy Radiation)

  • 신동오;신동호;김성훈;박성용;서원섭;안희경;강진오;홍성언
    • 한국의학물리학회지:의학물리
    • /
    • 제16권3호
    • /
    • pp.116-124
    • /
    • 2005
  • 고 에너지 광자선과 전자선의 흡수선량 결정에 대한 표준측정법은 공기커마 교정인수를 바탕으로 한 방법이 널리 사용되고 있으나 복잡한 수식과 물리적인자의 불확실성 등으로 정확도 향상에 한계가 있다. 따라서 최근 국제원자력기구와 미국의학물리학회에서 물 흡수선량을 기반으로 표준측정법을 개발하였다. 본 연구는 국제원자력기구의 IAEA TRS-398 과 미국의학물리학회의 AAPM 7e-51 물 흡수선량 표준측정법에 대한 인터넷을 기반으로 하는 선량교정 프로그램을 개발하였다. 이 프로그램은 인터넷 온라인상에서 사용할 수 있도록 C$\#$ 언어를 사용하여 각각의 표준측정법의 절차에 따라 사용자의 편의를 고려하여 개발하였다. 사용자는 인터넷을 통해 기준점에서의 두 가지 절차서에 따른 물 흡수선량을 비교할 수 있으며, 국내 각 기관에서 수행된 선량교정의 추세를 이해하고 보다 쉽게 관리할 수 있게 하였다. 웹 기반 데이터베이스를 이용하여 차후 국내 실정에 적합한 물 흡수선량 표준에 기반을 둔 표준측정법을 개발하는데 기여할 것으로 기대된다

  • PDF