• Title/Summary/Keyword: Photoelastic

Search Result 197, Processing Time 0.027 seconds

The Stress Distribution in a Flat Plate with a Reinforced Circular Hole under Biaxial Loading (보강(補强)된 원형(圓形)구멍을 가진 평판(平板)의 이축하중하(二軸荷重下)에서의 응력분포(應力分布))

  • S.J.,Yim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.8 no.1
    • /
    • pp.53-66
    • /
    • 1971
  • The effect of reinforced circular hole in a flat plate under general biaxial loading conditions is considered. The reinforcement is achieved by attaching a circular ring of uniform rectangular cross section along the boundary of the hole. This investigation includes a theoretical solution and an experimental conformation. In the theoretical analysis, Gurney's method is used to obtain a solution for the stress distribution and the solution is expressed in a general form, so that it can be applicable to the case of general biaxial loading and general values of Poisson's ratios. In the experimental work a systematic series of photoelastic models, as shown in Fig.5 and Table 1, were analyzed on polariscope. The experimental results were in good agreement with the theoretical ones, as shown in Fig.8 and 9. The conclusions derived are as follows: 1) The theoretical results, given in Eq. $(1){\sim}(5)$, are sufficient in accuracy for the engineering design purpose. 2) The stress concentration factor decreases as the ratio n increases, but not significant beyond n=3. 3) The stress concentration factor increase as the ratio m increases, but not significant below m=0.7.

  • PDF

Study on Deformation and Strength of Fillet Welds (Fillet Welding Joint의 파괴기구(破壞機構)와 강도(强度)에 관한 연구(硏究))

  • Dong-Suk,Um
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.7 no.2
    • /
    • pp.27-40
    • /
    • 1970
  • The distribution of stress and strain in elastic stages is investigated by the experiments of two dimensional photoelastic coating and Moire fringe method. Center block type and cover plate type of fillet welds are used as specimens in the test. The results are as follows. 1) Center block type gets less uniform stress distribution than cover plate type. And its stress concentration factor, especially at root, is larger than that at toe. 2) When main plate and cover plate closely contact and it cause friction, stress concentration decreases more than that in case of slit. That is because stress can be transmitted on the contact surface. 3) When slit is made, the outside of fillet gets more stress than the inside of it. 4) While the plastic strain distribution of center block type reaches the maximum at root and differs very slightly from that under lower loading, the plastic strain distribution of cover plate type is inclined to get the maximum at the outside of fillet rather than at root. 5) When the plastic strain value of cover plate type is compared with that of center block type at toe and root, the relations between the former and the latter shows root<toe and root>toe. 6) Because stress distribution becomes changed according to loading, fracture angle cannot be estimated by the peaks of elastic stress distribution. 7) The strain distribution just before fracture can be found by Moire fringe method.

  • PDF

ANALYSIS OF STRESS DEVELOPED WITHIN THE SUPPORTING TISSUE OF ABUTMENT TOOTH WITH INDIRECT RETAINER ACCORDING TO VARIOUS DESIGNS OF DIRECT RETAINER AND DECREE OF BONE RESORPTION (편측성 후방연장 국소의치에서 직접유지장치의 설계와 지대치 골흡수에 따른 간접유지장치 지대치 주위조직에 발생하는 응력분석)

  • Lee, Suk-Hyun;Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.150-165
    • /
    • 1998
  • For the purpose of evaluating the effect of both direct retainer design and bony absorption degree around abutment of indirect retainer on the supporting tissue of abutment of indirect retainer, dislodging force was transmitted to unilateral distal extension RPD bases. Analysis of stress distributed within the supporting tissue around abutment of indirect retainer was carried out. Using three-dimensional photoelastic stress analysis method and the conclusion is a follows. 1. According to the extent of force which the direct retainer of the most distal abutment tooth, the amount of force transmitted to the abutment tooth of indirect retainer was small. 2. Of all the cases, Mandibular first premolar which was used abutment tooth of indirect retainer, buccal, mesial and distal sides represented compression stress and lingual side represented tensile stress. 3. The more bone resorption of abutment tooth of indirect retainer, the more distortion of buccal and distal side of abutment tooth was existed and the extent of compression stress which was existed and distal side to abutment tooth was large. 4. When the alveolar bone around the abutment with indircet retainer is normal. The amount of force transmitted on abutment with indirect retainer was small in the order of Akers clasp, RPA clasp, RPI clasp. 5. When the alveolar bone around the abutment with indirect retainer has been absorbed 20% and 30%, the amount of force transmitted on abutment with indirect retainer was small in the order of RPA calsp, RPI clasp, Akers clasp. 6. When denture is displaced, shape of the direct retainer reciprocating abutment affect much the function of indirect retainer.

  • PDF

A literature review on clinical/ laboratory misfit evaluation on implant-prosthesis (임플란트와 상부보철물의 임상적/실험적 부적합 평가에 관한 문헌고찰)

  • Kim, Jong-Hoi;Cho, Woong-Rae;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.56 no.9
    • /
    • pp.462-478
    • /
    • 2018
  • The presence of implant-prosthesis misfits can cause various complications. It is very important to detect misfits to prevent such complications. There are various evaluation methods for misfit assessment including clinical methods and laboratory in vitro methods. The clinical misfit evaluation includes radiographic analysis, visual observation, probing, Sheffield test, evaluation with disclosing materials, and screw resistance test. The laboratory in vitro evaluation method includes indirect modelling evaluation and direct metrological visualization. Of the indirect modelling methods, photoelastic stress analysis, finite element analysis, strain gauge analysis, and microbial colonization analysis were reviewed. Of the direct metrological visualization, microscopic analysis, 3-D photogrammetric analysis, coordinate measuring analysis, and radiographic analysis were reviewed. In this review, the characteristics, advantages and disadvantages of each method were evaluated.

  • PDF

Analysis of Stress Distribution around a Central Crack Tip in a Tensile Plate Using Phase-Shifting Photoelasticity and a Power Series Stress Function (위상이동 광탄성법과 멱급수형 응력함수를 이용한 인장시편 중앙 균열선단 주위 응력장 해석)

  • Baek, Tae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • This paper presents stress distribution around a central crack tip in a tensile plate using phase-shifting photoelasticity and a power series stress function. Isochromatic data along the straight lines far from the crack tip were obtained by phase shifting photoelasticity and were used as input data of the hybrid experimental analysis. By using the complex-type power series stress equations, the photoelastic stress distribution fields in the vicinity of the crack and the mode I stress intensity factor were obtained. With the help of image processing software, accuracy and reliability was enhanced by twice multiplying and sharpening the measured isochromatics. Actual and reconstructed fringes were compared qualitatively. For quantitative comparison, percentage errors and standard deviations of the percentage errors were calculated for all measured input data by varying the number of terms in the stress function. The experimental results agreed with those predicted by finite element analysis and empirical equation within 2 percent error.

Hybrid Stress Analysis around a Circular Hole in a Tensile Plate by Use of Phase Shifting Photoelasticity (광탄성 위상이동법에 의한 인장시편 원형 구멍주위 하이브리드 응력해석)

  • Baek, Tae-Hyun;Lee, Choon-Tae;Yang, Min-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.15-22
    • /
    • 2007
  • A hybrid experimental-numerical method is presented for determining the stresses around a circular hole in a finite-width, tensile loaded plate. Measured fringe orders along straight lines provided the input information on the external boundary of the hybrid element. In order to see the effects of varying stress field, different numbers of terms in a power-series representation of the complex type conformal mapping stress function were tested. For qualitative comparison, actual isochromatic fringes were compared with reconstructed theoretical fringes using stress-optic law. For quantitative comparison, relative errors and standard deviations with respective to relative errors were analyzed for all measured points by changing the number of terms of stress function. The hybrid results are highly comparable with those predicted by FEA. The results show that this approach is effective and promising because isochromatic data along the straight lines in photoelasticity can be conveniently measured by use of phase shifting photoelasticity.

Precise Adsorption Measurement Technique by a Phase Modulated Ellipsometry (편광변조 타원해석법에 의한 정밀 흡착측정기술)

  • Choi, B.I.;Nham, H.S.;Park, N.S.;Youn, H.S.;Lim, Tong-Kun
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.531-538
    • /
    • 2004
  • Studies of adsorption isotherms with sharp step-wise layer condensation help us to better understanding of two dimensional layers. For this, an adsorption isotherm apparatus, using a phase modulated ellipsometric technique, has been constructed and an adsorption experiment has been performed. With subatomic scale resolution(∼0.3 $\AA$), the adsorption processes could be observed by ellipsometric signals. On measurement of multilayer adsorption of argon on highly oriented pyrolytic graphite(HOPG), thousands of adsorbed layers were observed at 34.04 K, which suggests that the adsorption is completely wet. On the contrary nine sharp layers of steps for adsorptions and desorptions were observed at 67.05 K. These isotherms obtained can provide a lot of information about thermodynamic states, bonding energies between adsobate and substrate, and structure transitions in the adsorbed film.

A PHOTOELASTIC STUDY OF THE STRESS DISTRIBUTION BY MULTILOOP EDGEWISE ARCH WIRE (Multiloop Edgewise Arch Wire가 야기하는 응력분포에 관한 광탄성학적 연구)

  • Yeom, Jeong Bae;Rhee, Byung Tae
    • The korean journal of orthodontics
    • /
    • v.20 no.2
    • /
    • pp.267-280
    • /
    • 1990
  • The purpose of this study was to investigate the force mechanism of Multiloop Edgewise Arch Wire and the intensity and distribution of stresses with vertical and intermaxillary elastics. The obtained results were as follows. 1. When plain wires were inserted and vertical and intermaxillary elastics were used in the upper and lower arch, the stresses of the anterior and posterior ends of wires were observed greatly but the stresses of the premolar were very small. 2. When MEAW were inserted in upper and lower arch, the upper 1st and 2nd premolar and the lower 1st premolar were extruded greatly. 3. In the area of the upper 1st molar and the lower 2nd premolar and the lower 1st molar, any stresses were not observed. 4. The vertical elastic counteracted the intrusion force of the MEAW in the anterior teeth but could not affect on posterior teeth. Using with the Class II elastics, the distal tipping force and extrusion force were exerted in the upper anterior teeth and the intrusion forces of the lower anterior teeth were relieved. Using with the Class III elastics, the extrusion force were exerted in the upper and lower anterior teeth, the distal tipping force were increased in the lower posterior teeth. 5. The Class II elastic counteracted the anterior intrusion force of the MEAW and extruded and tipped mesially the lower 2nd molar. The intrusion force of the MEAW also could not overcome the extrusion force of the class II elastics. 6. When the Class III elastics were engaged, the upper 2nd molar was extruded in spite of the intrusion forces of the MEAW and the extrusion forces of the lower anterior teeth and distal tipping forces in the posterior teeth were observed.

  • PDF

Investigations on the Magneto-optical Properties of Bilayered Co/Ni Micro-patterned Anti-dot Arrays

  • Deshpande, N.G.;Zheng, H.Y.;Hwang, J.S.;Lee, S.J.;Lee, Y.P.;Rhee, J.Y.;Kim, K.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.251-251
    • /
    • 2012
  • A lot of studies are undergoing on the magneto-optical (MO) properties of patterned magnetic systems for the reason that they have potential application to information technology such as ultrahigh-speed computing. Moreover, they can be considered as the future candidates for high-density MO storage devices. Not only the technical aspects, but there have been also tremendous interests in studying their properties related to the fundamental physics. The MO Kerr-rotation effects (both in reflected and the diffracted modes) and the magnetic force microscopy (MFM) are very useful techniques to investigate the micromagnetic properties of such periodic structures. Hence, in this study, we report on the MO properties of bilayered Cobalt (Co)/ nickel (Ni) micro-patterned anti-dot arrays. Such a ferromagnetic structure was made by sequentially depositing co (40 nm)/Ni (5 nm) bilayer on a Si substrate. The anti-dot patterning with hole diameter of $1{\mu}m$ was done only on the upper Co layer using photolithography technique, while the Ni underlayer was kept uniform. The longitudinal Kerr rotation (LKR) of the zeroth- and the first-order diffracted beams were measured at an incidence of $30^{\circ}$ by using a photoelastic modulator method. The external magnetic field was applied perpendicularly to the reflected and the diffracted beams using an electromagnet capable of a maximum field of ${\pm}5$ kOe. Significantly, it was observed that the LKR of the first-order diffracted beam is nearly 4 times larger than that of the zeroth-order beam. The simulated results for the hysteresis loops matched qualitatively well with the experimentally obtained ones. In conjunction with the LKR, we also investigated the magnetic-domain structure by using a MFM system, which were analyzed to elucidate the origin of the enhanced MO rotation.

  • PDF

PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT (인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석)

  • Park, Sang-Kyu;Lee, Baek-Soo;Engelke, W;Kim, Boo-Dong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.