• Title/Summary/Keyword: Photoelastic

Search Result 197, Processing Time 0.031 seconds

Photoelastic Study on Stress Distribution of the Fixed Partial Dentures with Various Designed Endosseous Implants (수종 골내 임플란트의 보철 수복물에 가해진 응력 분산에 관한 광탄성학적 연구)

  • Lee, Nung-Soo
    • The Journal of the Korean dental association
    • /
    • v.25 no.12 s.223
    • /
    • pp.1145-1156
    • /
    • 1987
  • The purpose of this experimental study was to analyze the stress distribution from fixed partial dentures to the surrounding structures. This study was carried out on the experimental bridges with K-L blade, F.D.B.I.-11 type, F.D.B.I.-21 type, shape-memory metal blade and two-Apacerams as posterior abutment. The stress patterns and fringes were observed through the circular transmission polariscope. The results of this study were obtained as follows: 1. The stress was more concentrated to the roots apex than the implants. 2. In all blade implants, the stress was more concentrated to the distal side than the mesial side. 3. F.D.B.I.-11 type was more stress concentrated than the 21 type. 4. Shape-memory metal blade was the most effective for stress distribution. 5. Apacerams were more stress concentrated than the blde types and in the model of Apaceram with rubber-ring, anterior root was tipped distally.

  • PDF

A Study on the Strain Analysis by Image Processing Technique (part 1: Development of Image Processing Technique with Microcomputer) (화상처리기법을 이용한 변형율해석에 관한 연구 (제1보 마이크로 컴퓨터를 이용한 화상처리기법의 개발))

  • 백인환;신문교
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.43-56
    • /
    • 1988
  • The image processing system consisted of the microcomputer IBM PC-XT and the graphic board (16 gray level and $640{\times}400$ pixels resolution) has been proposed, and the image processing softwares programmed in the BASIC and in the assembler language have been developed. The programs are consisted of the main menu and the sub menu, that have contained the subroutine for the capture for image data, the determination of region, the histogram, the change of value, the montage, the skeleton, the mask, the moving, the zoom, the disk access and the print. For the application, the photoelastic fringe data have been captured and analyzed. It was seen that the programs are available for the image processing.

  • PDF

Contact Singular Stress with Relief Notch by Using Dynamic Photoelasticity (동적광탄성 실험에 의한 응력이완 노치부근에서의 접촉특이응력해석)

  • 이억섭;황시원;나경찬
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.1
    • /
    • pp.55-62
    • /
    • 1996
  • The dynamic photoelastic technique has been utilized to investigate the possibility of relieving the large local singular stresses which are induce in the corner of a right angled indenter. The indenter compresses a semi-infinite body dynamically with an impact load applied on the top of the indenter. The effect of geometric changes to the indenter in terms of the diameter (d) and the location (ℓ) of the notch on the relieving of the dynamic contact stresses are investigated. A multi-spark-high speed camera with twelve sparks was used to take dynamic photographs. The contact singular stresses were found to be released by introducing the relief notch along the indenter. The optimal location and geometry of the relief notch need further experimental investigation.

  • PDF

A Study on the Characteristics of Two Dimensional Stress Wave Propagation Using the Distinct Element Method (개별요소법에 의한 이차원 응력파의 전달특성에 관한 연구)

  • 오금호;김문겸;원용호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.406-413
    • /
    • 1998
  • The distinct element method is improved to consider the charateristics of stress wave propagation in media involving the discontinuous faces. The distinct element method has many advantages to analyse the characteristics of the reflection, refraction and deflection of the waves in nonhomogeneous media. The double-suing connection system is adopted instead of the single-spring connection system because the distinct element cannot be used for analysing the contact behavior between the different materials by only one contact spring. For the verification of the improved code, the results of the numerical analysis are compared with that of the photoelastic experiments which are one or two dimensional wave propagation problem of the nonhomogeneous media including the different accoustic impendence material or voids. It is shown that the characteristics of the stress wave propagation in nonhomogeneous media can be simulated appropriately using the improved distinct element method.

  • PDF

A Study for Steadily Growing Interface Cracks in Anisotropic Dissimilar Materials (등속 진전하는 이방성 이종재 접합계면 균열에 대한 연구)

  • Cho, Sang-Bong;Kim, Jin-Kwang;Yoo, Byung-Kuk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1477-1485
    • /
    • 2003
  • The displacement vector field can be represented in terms of a scalar potential ${\phi}$ and a vector potential ${\phi}$. The scalar potential ${\phi}$ is related to dilatational waves and the vector potential ${\phi}$ is related to rotational waves. Using these two complex displacement potentials, the stress and displacement fields for steadily growing interface cracks in dissimilar materials are obtained. The energy release rate for steadily growing interface cracks in dissimilar materials are also obtained. And with photoelastic isochromatic patterns simulated by computer graphics, the stress intensity factors are discussed.

Analysis for Cracks of Functionally Gradient Materials by Photoelastic Experiment (광탄성실험에 의한 함수구배 재료 균열 해석)

  • Lee, Kwang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.48-53
    • /
    • 2004
  • This paper suggested the method determing the stress intensity factor (SIF) for functionally gradient materials (FGMs) by photo elastic experimental method. The SIF for the center crack in a finite rectangulat plate with a linear variation of shear modulus with constant density and Poisson's ratio along the direction of the crack under mode I static loading is obtained. The exponential and linear variation of stress fields are used for obtaining the SIF. The greater crack length, the increaser the difference of the SIF between right and left side crack tip.

  • PDF

Prediction of Birefringence Distribution in Cylindrical Glass Compression Test (유리 압축 실험에서의 복굴절 분포 예측)

  • Lee J.;Na J. W,;Rhim S.H.;Oh S.I.
    • Transactions of Materials Processing
    • /
    • v.13 no.6 s.70
    • /
    • pp.509-514
    • /
    • 2004
  • An analysis using FEM simulation was conducted to predict residual stresses and birefringence in simple compressed cylindrical glass as a preliminary part of the optimum design determination of optical lenses. The FEM simulation with the Maxwell viscoelastic constitutive model was used to predict thermal induced residual stresses and birefringence during the compression test considering stress relaxation. Also the linear photoelastic theory was introduced to calculate birefringence from the residual stress state. The error of simulation results between experimental results in the birefringence value at the center of glass specimen is $4.2\%$, and the error in the maximum radius of deformed glass specimen is $1.2\%$. The simulation results were in good agreement with deformation and birefringence distribution in the existing experimental result.

A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION OF 3 TYPES TMA MULTI-VERTICAL LOOP ARCH WIRE (TMA wire로 제작된 3종류의 MVLAW(Multi-Vertical Loop Arch Wire)의 초기응력분포에 관한 광탄성학적 연구)

  • Lee, Hyeong-Chul;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.73-85
    • /
    • 1995
  • Multi-Vertical Loop Arch Wire(MVLAW) is a kind of appliance for uprighting the mesially inclined posterior teeth axes simultaneously. In this study MVLAW was classified as 3 types by modifing the vertical loop design and named type A, B and C. Each MVLAW was fabricated from .017'x.025' TMA wire and preactivated at the distal end of the open vertical loop with 10 degree tip-back bend(type B has an electric welding stop at the distal end of each loop and type C has no electric welding stop). Type A MVLAW was preactivated at the apex of each open vertical loop with 10 degree tip-back bend(the electric welding stop of type A is positionod at the mesial side of each loop). The aim of the present study was to identify when and which MVLAW is more effective to correct the buccal segment axes simultaneously. The Photoelastic overview of the upper and lower right quadrant showed that stress concentrations were observed in its photoelastic model. The obtained results were as follows : 1. Higher level compression can be seen clearly at the distal curvature of the lower 1st and 2nd molar when A type MVLAW was applied without short class m elastic, but mild compression cannot be seen at the distal curvature of lower anterior teeth using the class m elastic. 2. Higher concentration was presented at the mesial curvature from the lower 1st premolar to the 2nd molar than the anterior teeth when B type MVLAW without short class III elastic was applied, but using the short class III elastic, higher concentration of compression was presented in the anterior teeth area. 3. Areas of higher compression and tension were not observed at the mesial and distal curvature of the entire 1ower teeth except lower central and lateral incisors in C type MVLAW without short class III elastic, but using the short class III elastic, higher concentration was seen at the mesial curvature of the lower 1st premolar and 1ower anterior teeth.

  • PDF

A photoelastic study on the initial stress distribution of the upper anterior teeth retraction using combination loop archwire and sliding mechanics (Combination loon archwire와 활주역학을 이용한 상악전치의 후방 견인시 나타나는 초기 응력 분포에 관한 광탄성학적 연구)

  • Yim, Kang-Soon;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.303-312
    • /
    • 2004
  • An unfavorable tipping movement can occur during the retraction of anterior teeth because orthodontic force is loaded by brackets positioned far from the center of resistance. To avoid this unfavorable movement, a compensating curved wire or lingual root torque wire is used. The purpose of this study is to investigate, using photoelastic material, the distribution of initial stress associated with the retraction of the incisors according to the degree of the compensating curve, to model changes associated with tooth ud alveolar bone structure. The following results were obtained by analysis of the polarizing plate of the effects of initial stress resulting from retraction of the anterior teeth: 1. When the incisors were retracted using combination archwire or sliding mechanics, the maximal polarizing pattern of the apical area decreased as the degree of the compensating owe increased from 0 to 15 to 30. 2. When the incisors were retracted by the combination archwire or sliding mechanics, the maximal polarizing pattern of the canine and premolar area increased as the degree of the compensating curve increased from 0to 15to 30. 3. A lower degree of polarizing patterns were associated with the combination archwire technique than the sliding mechanics technique at a given force. The above results indicate that there is no significant difference between the combination loop archwire technique and sliding mechanics, for the retraction of maxillary anterior teeth with decreased lingual tipping tendency by a compensating curve on the arch wire. However, the use of sliding mechanics is more effective for the prevention of lingual inclination of the anterior teeth, because the hook used in sliding mechanics is closer to the center of resistance of the maxillary anterior teeth.

A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type (골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析))

  • Lee, Moo-Geon;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.120-147
    • /
    • 1994
  • This study was performed for the purpose of evaluating the stress distribution around threaded type implants, cylindrical type implants and teeth connected with rigid or non-rigid connector. The stress distribution around the surrounding bone was analyzed by three-dimensional photoelastic method. Twelve mandibular photoelastic epoxy resin models and a circular polariscope were used to record the isochromatic fringes. After the stress distribution around the implant and tooth was observed, the results were as follows ; 1. In threaded type implants, stress concentrated patterns were observed at the neck either vertical or 25 degree lateral force. 2. The stress concentrated patterns were observed at the tooth apical portion and neck portions of the implant and tooth when a threaded implant was connected with the tooth by either a rigid or non-rigid connector. More force was generated at the tooth neck portion by a rigid connector and more force at the implant neck portion by a non-rigid connector. 3. The stress concentrated patterns were observed at the apical portion of the implant and tooth when a cylindrical type ,implant was connected with the tooth either by a rigid or non-rigid connector. More force was generated at the tooth apical portion by a rigid connector and more force at the neck portion of the tooth and implant by a non-rigid connector. 4. The stress around the tooth was more equally distributed in a threaded type implant than in a cylindrical implant when the tooth was connected with either a rigid or non-rigid connector. 5. The stress around a threaded type implant was progressively more equally distributed in the following order : 1) when used a single implant, 2) a non-rigid connection with the implant and tooth, 3) a rigid connection with the implant and tooth, 4) a rigid connection with two implant fixtures.

  • PDF