• Title/Summary/Keyword: Photodiode array(PDA)

Search Result 59, Processing Time 0.028 seconds

Development of a Multi - channel Detector for Capillary Electrophoresis System (모세관 전기영동 장치용 Photodiode Array 다채널 검출기의 개발에 관한 연구)

  • Hong, Seung Guk;Kim, Hai-Dong
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.96-104
    • /
    • 1998
  • A photodiode array multichannel detector system for capillary electrophoresis was developed. The photodiode array detector for capillary electrophoresis (CE-PDA) has 1024 photodetectors and can analyze sample by measuring UV/VIS absorption spectrum in 275~675 nm wavelength range. The CE-PDA instrument can get a spectrum in 30 ms during sample separation and can be programmed by a PC to control various experimental conditions required for sample analysis. The performance of the multichannel CE-PDA instrument was tested using L-ascorbic acid and alizarin yellow GG mixture. The reproducibility test of the CE-PDA system showed 5.6% RSD.

  • PDF

Simultaneous Determination of Cinnamaldehyde and Coumarin in Oryeong-san using HPLC with Photodiode Array Detector

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.18 no.2
    • /
    • pp.251-257
    • /
    • 2010
  • Objectives : To develop and validate High-performance liquid chromatography-photodiode array methods for simultaneous determination of two constituents in Oryeong-san(ORS). Methods : Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array(PDA) detection at 280 nm, were used for quantification of the two marker components of ORS. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was $H_2O$ and solvent B was acetonitrile. Results : Calibration curves were acquired with correlation coefficient ($r^2$)>0.9999, and the relative standard deviation(RSD) values(%) for intra- and inter-day precision were not exceed 1.0%. The recovery rate of each compound was in the range of 93.01-104.16%, with an RSD less than 2.0%. The contents of two compounds in ORS were 1.10-3.72 mg/g. Conclusions : The established HPLC method will be helpful to improve quality control of ORS.

Analyses of Additives Applied in a Polycarbonate (폴리카보네이트에 사용된 첨가제의 분석)

  • Kim, Seog-Jun
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.282-290
    • /
    • 2000
  • In this study, polymer additives were extracted and separated by Soxhlet extraction method and the dissolution-precipitation method from a polycarbonate (optical grade) which completely absorbed UV light below 390 nm. Analytical techniques such as UV-Vis spectroscopy, FT-IR, and HPLC were applied to analyze additives in polycarbonate. Separated materials from the polycarbonate may be a complex mixture containing additives such as UV stabilizer, antioxidants (primary and secondary), monomers, and oligomers. Several compounds such as bisphenol A, Irganox 1010, and Cyasorb UV-5411 were identified by chromatograms and UV spectra obtained from RP HPLC analysis using Bondapak $C_{18}$ column, methanol mobile phase, and a photodiode array (PDA) detector. Also, the content of UV-5411 in the polycarbonate was about 0.12 wt% by a quantitative analysis through UV spectroscopy.

  • PDF

Determination of Synthetic Food Colours by HPLC with Photodiode Array Detector (HPLC를 이용한 타르색소의 분리정량)

  • Yang, Ho-Chul;Heo, Nam-Chil
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.30-35
    • /
    • 1999
  • A simple, rapid, efficient method is for extraction of 13 synthetic water-soluble food colours (Tartrazine, Amarnth, Indigo carmine, New coccine, Sunset yellow FCF, Allura red AC, Eosine, Fast Green FCF, Brilliant Blue FCF, Erythrosine, Acid red, phloxine, Rose Bengal) by polyamide resin and for their quantitative by high performance liquid chromatography (HPLC). Colours (coal-tar dyes) were extracted with polyamide resin and then determinated by HPLC. The HPLC conditions using a reverse phase partition type column $(Nova-pak\;C_{18})$, photodiode array (PDA) detector and 1% Ammonium acetate / 60% acetonitrile in water as eluent, were acceptable for various kinds of colorants. By the use of the proposed method, a survey of coal-tar dyes was carried out on 20 samples and that were detected $4.76{\sim}133.47\;ppm$.

  • PDF

A fragmentation database of soyasaponins by liquid chromatography with a photodiode array detector and tandem mass spectrometry

  • Son, Haereon;Mukaiyama, Kyosuke;Omizu, Yohei;Tsukamoto, Chigen
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.172-179
    • /
    • 2021
  • Oleanane-type triterpenoids exist as secondary metabolites in various plants. In particular, soyasaponin, an oleanane-type triterpenoid, is abundant in the hypocotyl of soybean, one of the most widely cultivated crops in the world. Depending on their chemical structure, soyasaponins are categorized as group A saponins or group DDMP (2,3-dihydro-2,5-dihydroxy-6-methyl-4H-pyran-4-one) saponins. The different soyasaponin chemical structures present different health functionalities and taste characteristics. However, conventional phenotype screening of soybean requires a substantial amount of time for functionality of soyasaponins. Therefore, we attempted to use liquid chromatography with a photodiode array detector and tandem mass spectrometry (LC-PDA/MS/MS) for accurately predicting the phenotype and chemical structure of soyasaponins in the hypocotyl of five common soybean natural mutants. In this method, the aglycones (soyasapogenol A [SS-A] and soyasapogenol B [SS-B]) were detected after acid hydrolysis. These results indicated that the base peak and fragmentation differ depending on the chemical structure of soyasaponin with aglycone. Thus, a fragmentation database can help predict the chemical structure of soyasaponins in soyfoods and plants.

Development of an analytical method for the quantification of oleanonic acid from mastic gum using HPLC/PDA

  • Hak-Dong Lee;Chang-Dae Lee;So Yeon Choi;Sanghyun Lee
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.67-72
    • /
    • 2023
  • A simple and accurate method was developed for the quantitative analysis of oleanonic acid (OA) from mastic gum. The analysis was carried out using reverse-phase high-performance liquid chromatography combined with a photodiode array detector (HPLC/PDA). Our optimized method was validated by measuring various parameters, using an INNO C18 column fitted with a gradient elution system. The results revealed limits of detection and quantification of 0.34 and 1.042 ㎍/mL, respectively. The OA calibration curve exhibited excellent linearity over the concentration range of 0.0625 to 2.0 mg/mL, with r2 =0.9996. Accuracy tests revealed a high recovery rate of 99.44-103.66%, with precision values below 0.15%. These results suggest that the present analytical method can identify and quantify OA in mastic gum with high precision. The HPLC approach developed in this study might be applied to routine analyses and large-scale extraction procedures for OA content quantification.

Quality Characteristics of Dolsan Leaf Mustard according to Various Blanching Conditions and Liquid Chromatography with Photodiode Array and Tandem Mass Spectrometry Analysis (다양한 데침조건에서 돌산갓의 이화학적 특성 및 LC-PDA/MS/MS 분석)

  • Son, Hae-Reon;Oh, Sun-Kyung;Tsukamoto, Chigen;Choi, Myeong-Rak
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.20-26
    • /
    • 2016
  • This study aims to examine the optimum blanching conditions as a pretreatment condition to improve the storage stability of Dolsan leaf mustard pickle. The effects of the blan- ching temperature and time were investigated at a temperature range of $80-100^{\circ}C$. Sampling was done for 1 month after a 5 days interval. The L value of the Dolsan leaf mustard was found to be the highest at $80^{\circ}C$. The cutting force increased as the blanching temperature increased. The tensile strength decreased at $95^{\circ}C$ and $100^{\circ}C$. In addition, the sensory evaluation scores were the best at $80^{\circ}C$. The storage stability was assessed at various blanching temperatures to increase the sinigrin content during storage. Liquid chromatography with photodiode array and tandem mass spectrometry (LC-PDA/MS/MS) analysis was conducted to identify and quantify the sinigrin content in the Dolsan leaf mustard. Sinigrin as an internal standard was co-injected into each sample solution. The sample was monitored by recording the ultraviolet absorbance at 228 nm and by electrospray ionization (ESI) positive ion mode in the m/z 50-1,500 range. Blanching the sample at $80^{\circ}C$ showed the highest sinigrin concentration during storage among various temperatures and the maximum concentration was 350 ppm at 15 days storage. Study on utilization of vegetable from food processing of leaf mustard and preservation conservation results suggest that blanching at $80^{\circ}C$ is expected to improve the palatability of the pickle.

Simultaneous Determination of the Seven Phenylpropanoids in Xanthii Fructus Using a HPLC-PDA and LC-MS

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.24 no.3
    • /
    • pp.206-212
    • /
    • 2018
  • Xanthii Fructus has been traditionally used for the treatment of rhinitis, rheumatoid arthritis, and eczema. In this study, a high-performance liquid chromatography-photodiode array (HPLC-PDA) method was developed and then used for the simultaneous analysis of eight phenylpropanoids in Xanthii Fructus. The analytical column used for this separation was a $SunFire^{TM}$ $C_{18}$ column, maintained at $40^{\circ}C$. The mobile phase used was 1.0% acetic acid in distilled water and 1.0% acetic acid in acetonitrile with gradient elution. For identify of each component, the mass spectrometer (MS) was used a Waters triple quadrupole mass spectrometer requipped with electrospray ionization (ESI) source. The HPLC-PDA method showed good linearity: correlation coefficients were ${\geq}0.9996$. The limits of detection and quantification of the eight compounds were 0.02 - 0.04 and $0.06-0.14{\mu}g/mL$, respectively. The extraction recoveries ranged from 97.51 to 108.67%. The relative standard deviation values of intra- and inter-day precision were 0.06 - 1.55 and 0.09 - 1.68%, respectively. The validated HPLC-PDA method was applied to simultaneously analyse the amounts of eight phenlypropanoids in Xanthii Fructus.

Determination of fucoxanthin in cosmeceutical products by HPLC-PDA (HPLC-PDA를 이용한 기능성 화장품 중 푸코잔틴의 정량)

  • Choi, Jongkeun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.755-761
    • /
    • 2017
  • This study was conducted to establish an analytical method using an HPLC system equipped with a photodiode array (PDA) detector for the quality control of raw materials and cosmeceuticals containing fucoxanthin as an active ingredient. The column was octadecyl-functionalized silica gel and the measurement wavelength of the PDA was set to 499 nm. To validate the analytical method, the linearity of the calibration curve, detection limit, reproducibility and recovery rate were investigated and good results were obtained. The correlation coefficient of the calibration curve was 1.000 and the linearity was good in the concentration range of 0.5 ~ 100 ppm. Moreover, the limit of detection (LOD) was 0.1 ppm and the limit of quantification (LOQ) was 0.5 ppm. The results of the peak reproducibility test used for evaluating the system suitability showed that the RSD (n = 5) of the peak area was 2.0% and that of the retention time was 0.09%. In the spiking test, the recovery rate was $101.6{\pm}0.77%$. The fucoxanthin contents of the two kinds of fucoxanthin-containing raw materials were $49.6{\pm}3.3%$ and $1.03{\pm}0.016%$, respectively. In addition, the fucoxanthin content in the test product, which was intended to be 150 ppm, was $156.7{\pm}4.7ppm$. From the above results, it was concluded that this method could be applied to the quantitative analysis of fucoxanthin in cosmeceuticals.