• 제목/요약/키워드: Photochemical ozone

검색결과 162건 처리시간 0.023초

수도권 배출량 저감에 따른 오존 발생 과정 분석에 관한 수치연구 (Numerical Study on the Process Analysis of Ozone Production due to Emissions Reduction over the Seoul Metropolitan Area)

  • 정여민;이순환;이화운;전원배
    • 한국환경과학회지
    • /
    • 제21권3호
    • /
    • pp.339-349
    • /
    • 2012
  • In order to clarify the impact of emissions reductions on the air quality over Metropolitan area of Korean Peninsula, several numerical experiment and analysis of integrated process rate(IPR) of ozone were carried out. Numerical models used in this study are WRF for the estimate the meteorological elements and CMAQ for assessment of ozone concentration. As result in the sensitive test of VOC/NOx reduction experiments, although VOC reduction tends to induce the different impact on the advection and photochemical reaction rate of ozone in urban area and rural area, the mechanism of ozone appeared to be more sensitive to the reduction of VOC than that of NOx over the metropolitan and its surround area. So the control of VOC emission inventories is an effective means to decrease the ozone concentrations around this area.

인구특성을 고려한 노출평가: 부산지역 고농도 오존일 사례연구 (Ozone Exposure Assessment by Population Characteristics: A Case Study for High Ozone Days in Busan)

  • 황미경;방진희;오인보;김유근
    • 한국환경보건학회지
    • /
    • 제41권2호
    • /
    • pp.71-81
    • /
    • 2015
  • Objectives: Photochemical ozone pollution is associated with increased mortality risk. This study aims to assess the population exposure to ozone according to population characteristics for high ozone days in the Busan metropolitan region (BMR). Methods: The ozone exposure assessment in this study was performed using the WRF-CMAQ simulated ozone concentrations and the population data in the BMR. The settled and daytime population and their activity were considered to conduct the static and dynamic ozone exposure assessment. Results: Applying a static exposure assessment, in case that high ozone occurred throughout Busan area, the highest exposure levels were evaluated in urban neighborhoods. In case of ozone pollution in outer Busan, because sensitive groups have been relatively higher exposure, this case was also evaluated as part of that should not be overlooked. The dynamic exposure was higher than static exposure because the number of population exposed to ozone of high concentration is increased. This approach is important in a regard consider that daytime population distribution when high ozone occur. Conclusion: This study shows the different population exposure according to various ozone distributions for each episode day. Considering demographic characteristic such as population density and activity should be important to understanding the population exposure assessment when ozone pollution occurs.

인접지역간 오존 농도 차이에 대한 기상요소의 영향분석(부산광역시 기장군을 대상으로) (Analysis on the Effect of Meteorological Factors related to Difference of Ozone Concentration at the Neighboring Areas in Gijang Busan)

  • 김민경;이화운;정우식;도우곤
    • 한국환경과학회지
    • /
    • 제21권9호
    • /
    • pp.1097-1113
    • /
    • 2012
  • Ozone is the secondary photochemical pollutant formed from ozone precursor such as nitrogen dioxide and non-methane volatile organic compounds(VOCs). The ambient concentration of ozone depends on several factors: sunshine intensity, atmospheric convection, the height of the thermal inversion layer, concentrations of nitrogen oxides and VOCs. Busan is located in the southeast coastal area of Korea so the ozone concentration of Busan is mainly affected from the meteorological variables related to the sea such as sea breeze. In this study the ozone concentrations of Busan in 2008~2010 were used to analyse the cause of the regional ozone difference in eastern area of Busan. The average ozone concentration of Youngsuri was highest in Busan however the average ozone concentration of Gijang was equal to the average ozone concentration of Busan in 2008~2010. The two sites are located in eastern area of Busan but the distance of two sites is only 9km. To find the reason for the difference of ozone concentration between Youngsuri and Gijang, the meteorological variables in two sites were analyzed. For the analysis of meteorological variables the atmospheric numerical model WRF(Weather Research and Forecasting) was used at the day of the maximum and minimum difference in the ozone concentration at the two sites. As a result of analysis, when the boundary layer height was lower and the sea breeze was weaker in Youngsuri, the ozone concentration of Youngsuri was high. Furthermore when the sea breeze blew from the south in the eastern area of Busan, the sea breeze at Youngsuri turned into the southeast and the intensity of sea breeze was weaker because of the mountain in the southern region of Youngsuri. In that case, the difference of ozone concentration between Youngsuri and Gijang was considerable.

오존최대농도지표를 이용한 오존단기예측모형 개발 (Development of a Short-term Model for Ozone Using OPI)

  • 전의찬;김정욱
    • 한국대기환경학회지
    • /
    • 제15권5호
    • /
    • pp.545-554
    • /
    • 1999
  • We would like to develop a short-term model to predict the time-related concentration of ozone whose reaction mechanism is complex. The paper targets Seoul where an ozone alert system has recently been employed. In order to develop a short-term prediction model for ozone, we suggested the Ozone Peak Indicator(OPI), an equivalent of the potential daily maximum ozone concentration, with precursors being the only limiting factor, and we calculated the Ozone Peak Indicarot as OPI={$ rac{(O_3)_{max}cdot(H_{eH})_{max}(Rad)_{max}$ to preclude the influence of mixing height and solar radiation on the daily maximum ozone concentration. The OPI on the day of the prediction is to be calcultated by using the relation between OPI and the initial value of precursors. The basic prediction formula for time-related ozone concentration was established as $O_3(1)={(OPI)cdot Rad(t-2)H_{eH}}$, using the OPI, solar radiation two hours before prediction and mixing height. We developed, along with the basic formula for predicting photochemical oxidants, "SEOM"(Seoul Empirical Oxidants Model), a Fortran program that helps predict solar radiation and mixing height needed in the prediction of ozone pollution. When this model was applied to Seoul and an analysis of the correlation between the observed and the predicted ozone concentrations was made through SEOM, there appeared a very high correlation, with a coefficient of 0.815. SEOM can be described as a short-term prediction model for ozone concentration in large cities that takes into account the initial values of precursors, and changes in solar radiation and mixing height. SEOM can reflect the local characteristics of a particular and region can yield relatively good prediction results by a simple data input process.t process.

  • PDF

LCA 기법을 이용한 소맥분 생산 공정의 환경 영향 평가 (Environmental Impacts Assessment of the Wheat Flour Production Process Using the Life Cycle Assessment Method)

  • 추덕성;권혁구;김종규;이장훈
    • 한국환경보건학회지
    • /
    • 제34권1호
    • /
    • pp.62-69
    • /
    • 2008
  • The life cycle assessment method for environmental impact assessment was used, in this study, to assess the production process of wheat flour which is the most important material in the food industry. Environmental impact assessments were compared between that of the Ministry of Environment, Republic of Korea (method I) with that of the Ministry of Commerce, Industry and Energy (method II). Life cycle inventories (LCI) was performed using internal and external databases and the production statistics database of company S. The procedure of life cycle impact assessment (LCIA) was followed in terms of classification, characterization, normalization and weighting to identify the key issues. The impact categories of method I were divided into 8 categories with consideration of : abiotic resources depletion, global warming, ozone depletion, photochemical oxidant creation, acidification and eutrophication. The impact categories of method II were divided into 10 categories with consideration of: abiotic resources depletion, global warming, ozone depletion, photochemical oxidant creation, acidification, eutrophication, human toxicity, freshwater aquatic ecotoxicity, marine aquatic ecotoxicity and terrestrial ecotoxicity.

LCA를 이용한 유리병 재활용의 환경영향 평가 (Environmental Impact Evaluation for Glass Bottle Recycle using Life Cycle Assessment)

  • 백승혁;김형진;권영식
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1067-1074
    • /
    • 2014
  • Life Cycle Assessment(LCA) has been carried out to evaluate the environmental impacts of glass bottle recycle. The LCA consists of four stages such as Goal and Scope Definition, Life Cycle Inventory(LCI) Analysis, Life Cycle Impact Assessment(LCIA), and Interpretation. The LCI analysis showed that the major input materials were water, materials, sand, and crude oil, whereas the major output ones were wastewater, $CO_2$, and non-hazardous wastes. The LCIA was conducted for the six impact categories including 'Abiotic Resource Depletion', 'Acidification', 'Eutrophication', 'Global Warming', 'Ozone Depletion', and 'Photochemical Oxidant Creation'. As for Abiotic Resource Depletion, Acidification, and Photochemical Oxidant Creation, Bunker fuel oil C and LNG were major effects. As for Eutrophication, electricity and Bunker fuel oil C were major effects. As for Global Warming, electricity and LNG were major effects. As for Ozone Depletion, plate glasses were major effects. Among the six categories, the biggest impact potential was found to be Global Warming as 97% of total, but the rest could be negligible.

제주지역 지표 오존 농도의 시.공간적 분포 특성 (The Characteristics of Temporal and Spatial Distribution of Surface Ozone Concentration in Jeju Island)

  • 이기호;김대준;허철구
    • 한국환경과학회지
    • /
    • 제13권4호
    • /
    • pp.377-387
    • /
    • 2004
  • This study has been performed to clarify the characteristics of temporal and spatial distribution of surface ozone concentration over Jeju Island, one of the cleanest areas in Korea with low emissions of air pollutants. Ozone data are monitored at four sites in Jeju Island. These monitoring sites are located at two urban area(referred to Ido and Donghong), coastal area(Gosan site) and forest site(Chuna site). Ozone data has been routinely collected at these sites for the late four years. The patterns of seasonal cycle of ozone concentrations at all stations show the bimodal with the peaks on spring and autumn and a significant summer minimum. However, the patterns of diurnal variations at rural station, i.e., Gosan and Chuna sites are considerably different to those at urban stations such as Ido and Donghong sites. The patterns of $\DeltaO_3$ variations are very similar with those of monthly mean ozone concentrations and $\DeltaO_3$ values are exceeded 30 ppb, at urban stations. This may be that urban stations are more influenced by local photochemical reactions rather than rural stations. In order to assess the potential roles of meteorological parameters on ozone formation, the meteorological parameters, such as radiation, temperature, and wind are monitored together with ozone concentrations at all stations. The relationships of meteorological parameters to the corresponding ozone concentration are found to be insignificant in Jeju Island. However, at Gosan and Donghong stations, when the sea breeze blew toward the station, the ozone concentration is considerably increased.

Characteristics of near-surface ozone distribution

  • Kim, Yoo-Keun;Lee, Hwa-Woon;Kim, Jae-Hwan;Moon, Yun-Seob;Song, Sang-Keun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권3호
    • /
    • pp.127-137
    • /
    • 2000
  • This study presents an analysis of the characteristics of vertical ozone distribution near the surface using ozonesonde data(l995 to 1998), plus surface ozone and meteorological data from the Pohang region. These features were examined in detail using three case studies. The first related to episodes of high surface ozone concentrations during the Spring season when the frontogenesis between the high and low pressure associated with the upper-level jet stream was found to be located near the surface. The second was a 5-day winter period(l3 -17 December, 1997) in the Pohang province when the hourly concentrations exceeded 90 ppb on several occasions owing to low-level jets(LLJs) induced by a nocturnal stable layer. Accordingly, this explains why the high surface ozone concentrations occurred at night as the ozone was transported across the zone by a strong wind speed( over 12.5 ms .1). The third case study was ozone enhancement due to photochemical reactions. In this case, the maximum concentration of ozone exceeded 60 ppb in the summer(23 -28 August, 1997). When an ozone peak appeared within the boundary layer, the occurrence frequency of a low-level jet due to the nocturnal stable layer was about 77%, similarly the occurrence frequency of a near-surface ozone peak relative to the appearance of an LLJ was about 76%. Accordingly, there is clearly a close correlation between the occurrence of LLJs and near-surface ozone peaks.

  • PDF

국지순환풍 모델을 이용한 광양만권 대기오염물질의 수치모델링 (Numerical Modeling of Pollutants using Local Wind Model in Gwangyang Bay, Korea)

  • 이상득
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.13-23
    • /
    • 2003
  • A local wind model and a three dimensional local environmental model including advection, diffusion, deposition. and photochemical reactions were performed at Gwangyang Bay, Korea, to predict air flow and air pollutants concentrations. A large grid was used, and nesting method was employed for small grid calculation. From the meterological module simulation, we were able to reproduce local wind characteristics such as sea/land winds and mountain/valley winds simulation at Gwangyang Bay. In addition, the concentration module showed high concentration regions at Yosu industrial complex, Gwangyang steel company. and Container anchor. It was also seen that air pollutants were dispersed by sea/land winds. A comparison between the measurement and the prediction of sulfur dioxide and nitric oxide, which are relatively low-reacted pollutants, was performed. However, the measured nitrogen dioxide and ozone concentrations were higher than the simulated ones. Particularly, ozone concentration between 8 a..m. and 8 p.m. agreed well, but the measured ozone during the rest of time were generally higher.