• 제목/요약/키워드: Photo-fenton process

검색결과 22건 처리시간 0.02초

펜톤, 펜톤-유사 및 광-펜톤-유사 반응을 이용한 Rhodamine B의 탈색 (Decolorization of Rhodamine B by Fenton, Fonton-like and Photo-Fenton-like Oxidation)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제33권2호
    • /
    • pp.150-157
    • /
    • 2007
  • The chemical and photochemical decolorization of Rhodamine B (RhB) in water has been carried out by Fenton, Fenton-like and photo-Fenton-like process. The effect of applied $H_2O_2,\;Fe^{2+}$ dosage (Fenton process), $H_2O_2,\;Fe^{\circ}$ dosage (Fenton-like and photo-Fenton-like process), UV light power (photo-Fenton-like process) pH (all processes) have been studied. The results obtained showed that more than 98% of color removal was obtained for the RhB solutions in every process. However, Fenton-like process was not suitable for the color removal of RhB because Fenton-like process was required much more reagents than Fenton and photo-Fenton-like process. The Fenton and photo-Fenton-like process showed similar reagents need. Optimum pH for three processes in this study is about pH 3. The relative order of sensitivity for pH of each process was: Fenton-like > photo-Fenton-like > Fenton.

광펜톤반응과 펜톤반응에 의한 수중 클로로페놀 분해비교연구 (Degradation Of 4-chlorophenol By Photo-Fenton Process and Fenton Process in Aqueous Solutions)

  • 김현승;김일규
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.463-469
    • /
    • 2011
  • The degradation of 4-chlorophenol by various AOPs(Advanced Oxidation Processes) including the Fenton and the photo-Fenton process has been examined. In sole Fe, UV or $H_2O_2$ process without combination, low removal efficiencies have been achieved. But the photo-Fenton process showed higher removal efficiency for degradation of 4-chlorophenol than those of other AOPs including the Fenton process. Generally more hydrogen peroxide was required to achieve higher removal efficiencies of 4-CP at constant dosage of $FeSO_4$ in both of the Fenton and the photo-Fenton processes. Based on the results, The photo-Fenton process is proposed to be the most efficient alternative for degradation of 4-chlorophenol among the processes studied in this research.

광펜톤 반응에 의한 수중 2-클로로페놀 분해특성연구 (Degradation of 2-Chlorophenol in the Aqueous Phase by a Photo-Fenton Process)

  • 김일규
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.779-786
    • /
    • 2012
  • The degradation of 2-chlorophenol(2-CP) by various AOPs(Advanced Oxidation Processes) including the photo-Fenton process has been examined. In sole $Fe^{2+}$, UV or $H_2O_2$ process without combination, low removal efficiencies have been achieved. But the photo-Fenton process showed higher removal efficiency for degradation of 2-chlorophenol than those of other AOPs including the Fenton process and the UV processes. In the photo-Fenton process, the optimal experimental conditions of 2-chlorophenol degradation were obtained at pH 3 and the $Fe^{2+}/H_2O_2$molar ratio of 1. Also the 2-chlorophenol removal efficiency increased with decreasing of the initial 2-chlorophenol concentration. 3-chlorocatechol and chlorohydroquinone were identified as photo-Fenton reaction intermediates, and a degradation pathway of 2-chlorophenol in the aqueous phase during the photo-Fenton reaction was proposed.

과산화수소 연속주입식 광펜톤산화공정에 의한 4-염화페놀 분해연구 (Degradation of 4-Chlorophenol by a Photo-Fenton Process with Continuous Feeding of Hydrogen Peroxide)

  • 김일규
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.31-38
    • /
    • 2013
  • The degradation of 4-chlorophenol(4-CP) by various AOPs(Advanced Oxidation Processes) with continuous feeding of $H_2O_2$, including the ultraviolet/hydrogen peroxide, the Fenton and the photo-Fenton process has been investigated. The photo-Fenton process showed the highest removal efficiency for degradation of 4-chlorophenol than those of other AOPs including the Fenton process and the combined UV process with continuous feeding of $H_2O_2$. In the photo-Fenton process, the optimal experimental condition for 4-CP degradation was obtained at pH 3. Also the 4-CP removal efficiency increased with decreasing of the initial 4-CP concentration. 4-chlorocatechol and 4-chlororesorcinol were identified as photo-Fenton reaction intermediates, and the degradation pathways of 4-CP in the aqueous phase during the photo-Fenton reaction were proposed.

광-펜톤 산화반응을 이용한 Rhodamine B의 탈색 (Decolorization of Rhodamine B by Photo-Fenton Oxidation)

  • 박영식
    • 한국물환경학회지
    • /
    • 제23권2호
    • /
    • pp.274-280
    • /
    • 2007
  • The photochemical decolorization of Rhodamine B (RhB) in water has been carried out by photo-Fenton process. The effect of applied $H_2O_2$, $Fe^{2+}$ dose, solution pH and UV dose have been studied. The influence of constituent processes of photo-Fenton such as UV, $H_2O_2$ and Fenton has been investigated. Comparison of RhB removal was made between the photo-Fenton and $UV/H_2O_2$ process. The results obtained showed that the optimum dosage of $Fe^{2+}$ and $H_2O_2$ were 0.0031 mmol and 0.625 mol, respectively. pH 3 is found to be the optimum pH of for photo-Fenton process. pH and UV dose strongly influenced the decolorization of RhB in photo-Fenton process. The photo-Fenton and $UV/H_2O_2$ processes showed similar decolorization and seem to be appropriate for the decolorization of dye wastewater.

동력펌프주입식 광펜톤시스템에 의한 2,3-디염화페놀 분해특성 연구 (Degradation of 2,3-dichlorophenol by a Photo-Fenton Process with Continuous Pump-Feeding of Hydrogen Peroxide)

  • 김일규
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.84-90
    • /
    • 2014
  • The degradation of 2,3-dichlorophenol(2,3-diCP) by various advanced oxidation systems with continuous feeding of hydrogen peroxide including the ultraviolet/hydrogen peroxide, the Fenton and the photo-Fenton process has been conducted. The highest removal efficiency for 2,3-diCP in the aqueous phase was obtained by the photo-Fenton process among the advanced oxidation systems. In the photo-Fenton process, The removal efficiency of 2,3-diCP decreased with increasing pH in the range of 3 to 6, and it decreased with increasing initial concentration. As the intermediates of 2,3-diCP by photo-fenton reaction, 3,4-chlorocatechol and 2,3-dichlorohydroquinone were detected, thus the degradation pathways were proposed.

Photo-Fenton 공정과 UV/$H_2O_2$ 공정을 이용한 Lindane의 분해특성 비교 연구 (A Study on the degradation of Lindane in water by a Photo-Fenton process and a UV/$H_2O_2$ process)

  • 이주현;최혜민;김일규
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.109-117
    • /
    • 2010
  • In the present study, the degradation characteristics of Lindane by Advanced Oxidation Processes(UV/$H_2O_2$, Photo-Fenton process) were studied. The degradation efficiency of Lindane in aqueous solution was investigated at various initial pH values, Fenton's reagent concentrations and initial concentrations of Lindane. GC-ECD was used to analyze lindane. Lindane has not been degraded without application of AOPs over two hours. But, approximately 5% of lindane was degraded with UV or $H_2O_2$ alone. Lindane with UV/$H_2O_2$ process showed approximately 7% higher removal efficiency than $H_2O_2$ process. In the UV/$H_2O_2$ process, the pH values did not affect the removal efficiency. The optimal mole ratio of $H_2O_2/Fe^{2+}$ for lindane degradation is about 1.0 in Photo-Fenton process. Also, the experimental results showed that lindane removal efficiency increased with the decrease of initial concentration of lindane. Under the same conditions, the order lindane of removal efficiency is as following : Photo-Fenton process > UV/$H_2O_2$ process > $H_2O_2$ process. In addition, intermediate products were identified by GC-MS techniques. Than PCCH(Pentachlorocyclohexene) was identified as a reaction intermediate of the Photo-Fenton process.

Fenton 및 Photo-Fenton 산화공정을 이용한 염색 폐수의 처리에 관한 연구 (A Study on the Dye-Wastewater Treatment by Fenton and Photo-Fenton Oxidation Process)

  • 조일형;고영림;이소진;이홍근;조경덕
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.29-37
    • /
    • 2000
  • Fenton’s oxidation process is one of the most commonly applied processes to the wastewater which cannot be treated by conventional biological treatment processes. However, it is necessary to minimize the cost of Fenton’s oxidation treatment by modifying the treatment processes or other means of chemical treatment. So, as a method for the chemical oxidation of biorefractory or nonbiodegradable organic pollutants, the Photo-Fenton-Reaction which utilizes iron(11)salt. $H_2O$$_2$ and UV-light simultaneously has been proprosed. Therfore, the purpose of this study is to test a removal efficiency of dye-wastewater and treatment cost with Fenton’s and Photo-Fenton’s oxidation process. The Fe(11)/$H_2O$$_2$ reagent is referred to as the fenton’s reagent. which produces hydroxy radicals by the interaction of Fe(11) with $H_2O$$_2$. In this exoeriment, the main results are as followed; 1. The Fenton oxidation was most efficient in the pH range of 3-5. The optimal condition for initial reaction pH was 3.5 for the high CO $D_{Cr}$ & TOC-removal efficiency. 2. The removal efficiency of TOC and CO $D_{Cr}$ increased up to the molar ration between ferrate and hydrogen peroxide 0.2:1, but above that ratio removal efficiency hardly increased. 3. The highest removal efficiency of TOC and CO $D_{Cr}$ were showed when the mole ration of ferrate to hydrogen peroxide was 0.2:3.4. 4. Without pretreatment process, photo-fenton oxidation which was not absorbed UV light was not different to fenton oxidation. 5. And Fenton oxidtion with pretreatment process was similar to Fenton oxidation in the absence of coagulation, the proper dosage of F $e^{2+}$: $H_2O$$_2$ was 0.2:1 for the optimal removal efficiency of TOC or CO $D_{Cr}$ .6. Also, TOC & CO $D_{Cr}$ removal efficiency in the photo-fenton oxidation with pretreatment was increased when UV light intensity enhanced.7. Optimum light intensity in the range from 0 to 1200 W/$m^2$ showed that UV-intensity with 1200W/$m^2$ was the optimum condition, when F $e_{2+}$:$H_2O$$_2$ ratio for the highest decomposition was 0.2:2.5.EX>$_2$ ratio for the highest decomposition was 0.2:2.5.

  • PDF

PHOTO-FENTON 공정을 이용한 축산폐수처리시 운전인자의 최적조건 (Optimal Condition of Operation Parameter for Livestock Wastewater Treatment using Photo-Fenton Process)

  • 박재홍;장순웅;조일형
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.284-288
    • /
    • 2005
  • In this study, photochemical advanced oxidation processes (AOPs) utilizing the Photo Fenton reaction ($Fe^{2+}+H_2O_2+UV$) were investigated in lab-scale experiments for the treatment of livestock wastewater. For the experimets, the livestock wastewater was pretreated by coagulation with $3,000mg/L\;FeCl_3$. The optimal conditions for Photo-Fenton processes were determined: pH was 5, the concentration of ferrous ion (Fe II) was 0.01 M. The concentration of hydrogen peroxide was 0.1 M, and molar ratio ($Fe^{2+}/H_2O_2$) was 0.1. The optimal reaction time was 80 min. Under the optimal condition of Photo-Fenton process, chemical oxygen demand (COD), color and fecal coliform removal efficiencies were about 79, 70, and 99.4%, respectively and sludge production was 7.5 mL from 100 mL of solution.

$UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton 산화방법에 의한 Citric Acid의 분해효율 비교 (Comparative Studies Of the $UV/H_2O_2,\;UV/TiO_2/H_2O_2$ and Photo-Fenton Oxidation for Degradation of Citric Acid)

  • 서민혜;조순행;하동윤
    • 대한환경공학회지
    • /
    • 제28권4호
    • /
    • pp.429-437
    • /
    • 2006
  • 화학세정폐수에 함유되어 있는 citric acid의 효율적인 처리방안을 수립하기 위해 $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton 산화방법을 이용하여 각각 citric acid의 제거효율 및 그에 따른 전력소비량을 평가하였다. 그 결과 조사된 최적 처리조건에서 $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton 산화방법을 이용한 citric acid 농도에 근거한 TOC 제거효율은 각각 95.5%, 92.3%, 91.5%로 조사되었으며, 그에 따른 전력소비량은 $11.26kWh/m^3,\;3.85kWh/m^3,\;0.799kWh/m^3$으로 조사되었다. 이 결과에 의하면 세가지 광화학적 산화방법 모두 유기물질이 90% 이상 제거되어 citric acid의 분해에 효과적인 것으로 판단되었다. 그러나 Photo-Fenton 산화방법이 다른 방법에 비해 처리에 소요되는 반응시간이 짧은 것으로 나타났다. 또한 광화학적 산화방법의 운영비를 결정짓는데 중요한 요소인 전력소모량 측면에서도 Photo-Fenton 산화방법이 다른 방법에 비해 우수한 것으로 조사되어 본 연구에서 비교하는 세가지 방법 중 citric acid 처리에는 Photo-Fenton 방법이 효율적인면과 경제성면에서 가장 적합한 처리기술로 결론지을 수 있었다.